The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Automated layer segmentation of macular OCT images using dual-scale gradient information
Open accessAbstract
A novel automated boundary segmentation algorithm is proposed for fast and reliable quantification of nine intra-retinal boundaries in optical coherence tomography (OCT) images. The algorithm employs a two-step segmentation schema based on gradient information in dual scales, utilizing local and complementary global gradient information simultaneously. A shortest path search is applied to optimize the edge selection. The segmentation algorithm was validated with independent manual segmentation and a reproducibility study. It demonstrates high accuracy and reproducibility in segmenting normal 3D OCT volumes. The execution time is about 16 seconds per volume (480x512x128 voxels). The algorithm shows potential for quantifying images from diseased retinas as well.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Detection of Macular Ganglion Cell Loss in Glaucoma by Fourier-Domain Optical Coherence Tomography
Tan, O., Chopra, V., Lu, A. T.-H., Schuman, J. S., Ishikawa, H., Wollstein, G., Varma, R., & Huang, D. (2009) · Ophthalmology · doi:10.1016/j.ophtha.2009.05.025 · Cited by 665
Garvin, M. K., Abramoff, M. D., Wu, X., Russell, S. R., Burns, T. L., & Sonka, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2016958 · Cited by 626
Macular Segmentation with Optical Coherence Tomography
Ishikawa, H., Stein, D. M., Wollstein, G., Beaton, S., Fujimoto, J. G., & Schuman, J. S. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-0335 · Cited by 498
Ultrahigh-resolution high-speed retinal imaging using spectral-domain optical coherence tomography
Cense, B., Nassif, N. A., Chen, T. C., Pierce, M. C., Yun, S.-H., Park, B. H., Bouma, B. E., Tearney, G. J., & de Boer, J. F. (2004) · Optics Express · doi:10.1364/opex.12.002435 · Cited by 468
van Dijk, H. W., Kok, P. H. B., Garvin, M., Sonka, M., DeVries, J. H., Michels, R. P. J., van Velthoven, M. E. J., Schlingemann, R. O., Verbraak, F. D., & Abra`moff, M. D. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-3143 · Cited by 367
Mapping of Macular Substructures with Optical Coherence Tomography for Glaucoma Diagnosis
Tan, O., Li, G., Lu, A. T.-H., Varma, R., & Huang, D. (2008) · Ophthalmology · doi:10.1016/j.ophtha.2007.08.011 · Cited by 361
Garvin, M. K., Abramoff, M. D., Kardon, R., Russell, S. R., Wu, X., & Sonka, M. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.923966 · Cited by 336
Retinal pigment epithelium segmentation by polarization sensitive optical coherence tomography
Götzinger, E., Pircher, M., Geitzenauer, W., Ahlers, C., Baumann, B., Michels, S., Schmidt-Erfurth, U., & Hitzenberger, C. K. (2008) · Optics Express · doi:10.1364/oe.16.016410 · Cited by 294
Automated detection of retinal layer structures on optical coherence tomography images
DeBuc, D. C., Salinas, H. M., & Puliafito, C. A. (2005) · Optics Express · doi:10.1364/opex.13.010200 · Cited by 288
Retinal thickness measurements from optical coherence tomography using a Markov boundary model
Koozekanani, D., Boyer, K., & Roberts, C. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.952728 · Cited by 231
Intra-retinal layer segmentation in optical coherence tomography images
Mishra, A., Wong, A., Bizheva, K., & Clausi, D. A. (2009) · Optics Express · doi:10.1364/oe.17.023719 · Cited by 214
Quellec, G., Lee, K., Dolejsi, M., Garvin, M. K., Abramoff, M. D., & Sonka, M. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2047023 · Cited by 214
Hood, D. C., Lin, C. E., Lazow, M. A., Locke, K. G., Zhang, X., & Birch, D. G. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-2936 · Cited by 209
Self-citationHood, D. C., Fortune, B., Arthur, S. N., Xing, D., Salant, J. A., Ritch, R., & Liebmann, J. M. (2008) · Journal of Glaucoma · doi:10.1097/ijg.0b013e3181629a02 · Cited by 207
Self-citationGonzalez-Garcia, A., Vizzeri, G., Bowd, C., Medeiros, F. A., Zangwill, L. M., & Weinreb, R. N. (2009) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2008.12.032 · Cited by 200
Polito, A. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.10.1330 · Cited by 175
Retinal nerve fiber layer thickness map determined from optical coherence tomography images
Mujat, M., Chan, R. C., Cense, B., Hyle Park, B., Joo, C., Akkin, T., Chen, T. C., & de Boer, J. F. (2005) · Optics Express · doi:10.1364/opex.13.009480 · Cited by 162
Quantitative Thickness Measurement of Retinal Layers Imaged by Optical Coherence Tomography
Shahidi, M., Wang, Z., & Zelkha, R. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.01.012 · Cited by 130
Self-citationKajic, V., Považay, B., Hermann, B. M., Höfer, B., Marshall, D., Rosin, P. L., & Drexler, W. (2010) · Optics Express · doi:10.1364/oe.18.014730 · Cited by 129
Automated Layer Segmentation of Optical Coherence Tomography Images
Lu, S., Cheung, C. Y.-L., Liu, J., et al. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055057 · Cited by 96
Towards quantitative analysis of retinal features in optical coherence tomography
Baroni, M., Fortunato, P., & Torre, A. L. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.06.003 · Cited by 84
Cited by
Glaucomatous damage of the macula
Hood, D. C., Raza, A. S., de Moraes, C. G. V., Liebmann, J. M., & Ritch, R. (2013) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.08.003 · Cited by 867
Self-citationRetinal layer segmentation of macular OCT images using boundary classification
Lang, A., Carass, A., Hauser, M., Sotirchos, E. S., Calabresi, P. A., Ying, H. S., & Prince, J. L. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.001133 · Cited by 310
Macular OCT Classification Using a Multi-Scale Convolutional Neural Network Ensemble
Rasti, R., Rabbani, H., Mehridehnavi, A., & Hajizadeh, F. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2780115 · Cited by 298
Metadata
- Authors
- Yang, Q., Reisman, C. A., Wang, Z., Fukuma, Y., Hangai, M., Yoshimura, N., Tomidokoro, A., Araie, M., Raza, A. S., Hood, D. C., & Chan, K.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2010-09-22
- Volume
- 18
- Issue
- 20
- Pages
- 21293
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2013107002
- Cited by
- 284
- References
- 25
- FWCI
- 10.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.