Terahertz Pulsed Spectroscopy of Human Basal Cell Carcinoma
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Good contrast is seen between normal tissue and regions of tumor in terahertz pulsed imaging of basal cell carcinoma (BCC). To date, the source of contrast at terahertz frequencies is not well understood. In this paper we present results of a spectroscopy study comparing the terahertz properties (absorption coefficient and refractive index) of excised normal human skin and BCC. Both the absorption coefficient and refractive index were higher for skin that contained BCC. The difference was statistically significant over the range 0.2 to 2.0 THz (6.6 cm−1 to 66.6 cm−1) for absorption coefficient and 0.25 to 0.90 THz (8.3 cm−1 to 30 cm−1) for refractive index. The maximum difference for absorption was at 0.5 THz (16.7 cm−1). These changes are consistent with higher water content. These results account for the contrast seen in terahertz images of BCC and explain why parameters relating to the reflected terahertz pulse provide information about the lateral spread of the tumor. Knowing the properties of the tissue over the terahertz frequency range will enable the use of mathematical models to improve understanding of the terahertz response of normal and diseased tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Far-infrared time-domain spectroscopy with terahertz beams of dielectrics and semiconductors
Grischkowsky, D., Keiding, S., van Exter, M., & Fattinger, C. (1990) · Journal of the Optical Society of America B · doi:10.1364/josab.7.002006 · Cited by 2,239
Hu, B. B., & Nuss, M. C. (1995) · Optics Letters · doi:10.1364/ol.20.001716 · Cited by 1,648
Picosecond photoconducting Hertzian dipoles
Auston, D. H., Cheung, K. P., & Smith, P. R. (1984) · Applied Physics Letters · doi:10.1063/1.95174 · Cited by 1,037
Material parameter estimation with terahertz time-domain spectroscopy
Dorney, T. D., Baraniuk, R. G., & Mittleman, D. M. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001562 · Cited by 807
Mittleman, D. M., Jacobsen, R. H., & Nuss, M. C. (1996) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.571768 · Cited by 806
Kindt, J. T., & Schmuttenmaer, C. A. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp960141g · Cited by 687
Far-infrared vibrational modes of DNA components studied by terahertz time-domain spectroscopy
Fischer, B. M., Walther, M., & Jepsen, P. U. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/21/319 · Cited by 588
Terahertz Pulse Imaging of ex vivo Basal Cell Carcinoma
Woodward, R. M., Wallace, V. P., Pye, R. J., Cole, B. E., Arnone, D. D., Linfield, E. H., & Pepper, M. (2003) · Journal of Investigative Dermatology · doi:10.1046/j.1523-1747.2003.12013.x · Cited by 434
Self-citationTerahertz Pulsed Imaging of Human Breast Tumors
Fitzgerald, A. J., Wallace, V. P., Jimenez-Linan, M., Bobrow, L., Pye, R. J., Purushotham, A. D., & Arnone, D. D. (2006) · Radiology · doi:10.1148/radiol.2392041315 · Cited by 396
Self-citationIn vivo study of human skin using pulsed terahertz radiation
Pickwell, E., Cole, B. E., Fitzgerald, A. J., Pepper, M., & Wallace, V. P. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/9/001 · Cited by 381
Self-citation
Cited by
Imaging with terahertz radiation
Chan, W. L., Deibel, J., & Mittleman, D. M. (2007) · Reports on Progress in Physics · doi:10.1088/0034-4885/70/8/r02 · Cited by 965
Terahertz pulsed spectroscopy of freshly excised human breast cancer
Ashworth, P. C., Pickwell-MacPherson, E., Provenzano, E., Pinder, S. E., Purushotham, A. D., Pepper, M., & Wallace, V. P. (2009) · Optics Express · doi:10.1364/oe.17.012444 · Cited by 479
Self-citationTerahertz Sensing Based on Metasurfaces
Beruete, M., & Jáuregui‐López, I. (2020) · Advanced Optical Materials · doi:10.1002/adom.201900721 · Cited by 387
THz Medical Imaging: in vivo Hydration Sensing
Taylor, Z. D., Singh, R. S., Bennett, D. B., Tewari, P., Kealey, C. P., Bajwa, N., Culjat, M. O., Stojadinovic, A., Lee, H., Hubschman, J.-P., et al. (2011) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2011.2159551 · Cited by 362
Zhang, J., Mu, N., Liu, L., Xie, J., Feng, H., Yao, J., Chen, T., & Zhu, W. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113241 · Cited by 325
From Terahertz Imaging to Terahertz Wireless Communications
Huang, Y., Shen, Y., & Wang, J. (2023) · Engineering · doi:10.1016/j.eng.2022.06.023 · Cited by 312
Smolyanskaya, O. A., Chernomyrdin, N. V., Konovko, A. A., Zaytsev, K. I., Ozheredov, I. A., Cherkasova, O. P., Nazarov, M. M., Guillet, J.-P., Kozlov, S. A., Kistenev, Y. V., et al. (2018) · Progress in Quantum Electronics · doi:10.1016/j.pquantelec.2018.10.001 · Cited by 292
Self-citationThe potential of terahertz imaging for cancer diagnosis: A review of investigations to date.
Yu, C., Fan, S., Sun, Y., & Pickwell‐MacPherson, E. (2012) · PubMed · doi:10.3978/j.issn.2223-4292.2012.01.04 · Cited by 289
The progress and perspectives of terahertz technology for diagnosis of neoplasms: a review
Zaytsev, K. I., Dolganova, I. N., Chernomyrdin, N. V., Katyba, G. M., Gavdush, A. A., Cherkasova, O. P., Komandin, G. A., Shchedrina, M. A., Khodan, A. N., Ponomarev, D. S., et al. (2020) · Journal of Optics · doi:10.1088/2040-8986/ab4dc3 · Cited by 205
Wilmink, G. J., Ibey, B. L., Rivest, B. D., Grundt, J. E., Roach, W. P., Tongue, T. D., Schulkin, B. J., Laman, N., Peralta, X. G., Roth, C. C., et al. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3570648 · Cited by 109
Improved sample characterization in terahertz reflection imaging and spectroscopy
Huang, S., Ashworth, P. C., Kan, K. W., Chen, Y., Wallace, V. P., Zhang, Y.-T., & Pickwell-MacPherson, E. (2009) · Optics Express · doi:10.1364/oe.17.003848 · Cited by 96
Self-citationDiffuse terahertz spectroscopy in turbid media using a wavelet-based bimodality spectral analysis
Khani, M. E., Osman, O. B., & Arbab, M. H. (2021) · Scientific Reports · doi:10.1038/s41598-021-02068-7 · Cited by 28
Metadata
- Authors
- Wallace, V. P., Fitzgerald, A. J., Pickwell, E., Pye, R. J., Taday, P. F., Flanagan, N., & Ha, T.
- Venue
- Applied Spectroscopy
- Publisher
- SAGE Publications
- Published
- 2006-10
- Volume
- 60
- Issue
- 10
- Pages
- 1127-1133
- ISSN
- 0003-7028 (ISSN-L)
- 1943-3530
- OpenAlex
- W2154012811
- Cited by
- 225
- References
- 33
- FWCI
- 6.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.