Repeated Training with Augmentative Vibrotactile Feedback Increases Object Manipulation Performance
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
Most users of prosthetic hands must rely on visual feedback alone, which requires visual attention and cognitive resources. Providing haptic feedback of variables relevant to manipulation, such as contact force, may thus improve the usability of prosthetic hands for tasks of daily living. Vibrotactile stimulation was explored as a feedback modality in ten unimpaired participants across eight sessions in a two-week period. Participants used their right index finger to perform a virtual object manipulation task with both visual and augmentative vibrotactile feedback related to force. Through repeated training, participants were able to learn to use the vibrotactile feedback to significantly improve object manipulation. Removal of vibrotactile feedback in session 8 significantly reduced task performance. These results suggest that vibrotactile feedback paired with training may enhance the manipulation ability of prosthetic hand users without the need for more invasive strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Age differences in short-term retention of rapidly changing information.
Kirchner, W. K. (1958) · Journal of Experimental Psychology · doi:10.1037/h0043688 · Cited by 1,798 · cited 1×
“In order to determine the motor task performance during a simultaneous cognitive load, an auditory 2-back task was used [31].”
MethodElectrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Consumer design priorities for upper limb prosthetics
Biddiss, E., Beaton, D., & Chau, T. (2007) · Disability and Rehabilitation: Assistive Technology · doi:10.1080/17483100701714733 · Cited by 519 · cited 2×
“Prosthetic hand users have specifically requested haptic feedback as well as relief from visual attention to perform functions [2,3].”
BackgroundResults of an internet survey of myoelectric prosthetic hand users
Pylatiuk, C., Schulz, S., & Döderlein, L. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640601061265 · Cited by 257 · cited 2×
“Prosthetic hand users have specifically requested haptic feedback as well as relief from visual attention to perform functions [2,3].”
BackgroundSchultz, A. E., & Kuiken, T. A. (2011) · PM&R · doi:10.1016/j.pmrj.2010.06.016 · Cited by 186 · cited 1×
“) and the DEKA Arm (‘‘Luke Arm’’, DEKA Research and Development Corporation), along with advanced strategies for control, as reviewed in [1].”
BackgroundDesign and Evaluation of a Low-Cost Force Feedback System for Myoelectric Prosthetic Hands
Pylatiuk, C., Kargov, A., & Schulz, S. (2006) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200604000-00007 · Cited by 156 · cited 4×
“Unfortunately, past research utilizing vibrotactile feedback has been at best inconclusive about its effect on motor performance [5,21,23,24].”
BackgroundMethodInfluentialPatterson, P. E., & Katz, J. A. (1992) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.1992.01.0001 · Cited by 147 · cited 3×
“Unfortunately, past research utilizing vibrotactile feedback has been at best inconclusive about its effect on motor performance [5,21,23,24].”
BackgroundResultMicera, S., Navarro, X., Carpaneto, J., Citi, L., Tonet, O., Rossini, P. M., Carrozza, M. C., Hoffmann, K. P., Vivo, M., Yoshida, K., et al. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2008.2006207 · Cited by 120
Riso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98
Stepp, C. E., & Matsuoka, Y. (2011) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2011.2168981 · Cited by 28 · cited 4×
“neck, and foot), presented in a random order [25].”
BackgroundMethodResultSelf-citation
Cited by
Control strategies for active lower extremity prosthetics and orthotics: a review
Tucker, M. R., Olivier, J., Pagel, A., Bleuler, H., Bouri, M., Lambercy, O., Millán, J. D. R., Riener, R., Vallery, H., & Gassert, R. (2015) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-12-1 · Cited by 1,047
“Electrotactile [95,96,100,101] and vibrotactile [88,102 ,103] stimulation have been used to convey information about characteristics of gait and postural co ntrol and possible deviations.”
MethodA Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“However, vibrational feedback requires users to undergo training in order to develop the full benefit [88].”
BackgroundClemente, F., D'Alonzo, M., Controzzi, M., Edin, B. B., & Cipriani, C. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2500586 · Cited by 209
(2018) · Springer Series on Touch and Haptic Systems · doi:10.1007/978-3-319-58316-7 · Cited by 60
Metadata
- Authors
- Stepp, C. E., An, Q., & Matsuoka, Y.
- Venue
- PLoS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2012-02-27
- Volume
- 7
- Issue
- 2
- Pages
- e32743
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2071309387
- Cited by
- 61
- References
- 10
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.