Accuracy of Electronic Health Record Data for Identifying Stroke Cases in Large-Scale Epidemiological Studies: A Systematic Review from the UK Biobank Stroke Outcomes Group
Open accessAbstract
OBJECTIVE: Long-term follow-up of population-based prospective studies is often achieved through linkages to coded regional or national health care data. Our knowledge of the accuracy of such data is incomplete. To inform methods for identifying stroke cases in UK Biobank (a prospective study of 503,000 UK adults recruited in middle-age), we systematically evaluated the accuracy of these data for stroke and its main pathological types (ischaemic stroke, intracerebral haemorrhage, subarachnoid haemorrhage), determining the optimum codes for case identification. METHODS: We sought studies published from 1990-November 2013, which compared coded data from death certificates, hospital admissions or primary care with a reference standard for stroke or its pathological types. We extracted information on a range of study characteristics and assessed study quality with the Quality Assessment of Diagnostic Studies tool (QUADAS-2). To assess accuracy, we extracted data on positive predictive values (PPV) and-where available-on sensitivity, specificity, and negative predictive values (NPV). RESULTS: 37 of 39 eligible studies assessed accuracy of International Classification of Diseases (ICD)-coded hospital or death certificate data. They varied widely in their settings, methods, reporting, quality, and in the choice and accuracy of codes. Although PPVs for stroke and its pathological types ranged from 6-97%, appropriately selected, stroke-specific codes (rather than broad cerebrovascular codes) consistently produced PPVs >70%, and in several studies >90%. The few studies with data on sensitivity, specificity and NPV showed higher sensitivity of hospital versus death certificate data for stroke, with specificity and NPV consistently >96%. Few studies assessed either primary care data or combinations of data sources. CONCLUSIONS: Particular stroke-specific codes can yield high PPVs (>90%) for stroke/stroke types. Inclusion of primary care data and combining data sources should improve accuracy in large epidemiological studies, but there is limited published information about these strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“This large biobank has collected multiple layers of data from participants, including sociodemographic and lifestyle information, physical measurements, biological samples, 12-lead electrocardiograms and EHR data 82 .”
From Multimodal biomedical AI (2022) · cites this paper as [82]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Lozano, R., Naghavi, M., Foreman, K., Lim, S., Shibuya, K., Aboyans, V., Abraham, J., Adair, T., Aggarwal, R., Ahn, S. Y., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61728-0 · Cited by 14,070
Sudlow, C., Gallacher, J., Allen, N., Beral, V., Burton, P., Danesh, J., Downey, P., Elliott, P., Green, J., Landray, M., et al. (2015) · PLOS Medicine · doi:10.1371/journal.pmed.1001779 · Cited by 12,728 · cited 1×
“By 2017, around 5,000 incident strokes are expected to have occurred among UK Biobank participants [12].”
BackgroundSelf-citationInterval Estimation for a Binomial Proportion
Brown, L. D., Cai, T. T., & DasGupta, A. (2001) · Statistical Science · doi:10.1214/ss/1009213286 · Cited by 3,538 · cited 1×
“We calculated 95% confidence intervals for PPV, sensitivity, specificity and NPV values in Stata (version 12) using the Wilson method for binomial proportions [26].”
MethodO'Donnell, M. J., Xavier, D., Liu, L., Zhang, H., Chin, S. L., Rao-Melacini, P., Rangarajan, S., Islam, S., Pais, P., McQueen, M. J., et al. (2010) · The Lancet · doi:10.1016/s0140-6736(10)60834-3 · Cited by 3,448
Experience from a multicentre stroke register: a preliminary report.
Hatano, S. (1976) · Europe PMC (PubMed Central) · Cited by 1,526
Validation and validity of diagnoses in the General Practice Research Database: a systematic review
Herrett, E., Thomas, S. L., Schoonen, W. M., Smeeth, L., & Hall, A. J. (2010) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2009.03537.x · Cited by 1,109
Rothwell, P., Coull, A., Giles, M., Howard, S., Silver, L., Bull, L., Gutnikov, S., Edwards, P., Mant, D., Sackley, C., et al. (2004) · The Lancet · doi:10.1016/s0140-6736(04)16405-2 · Cited by 1,094
Transient Ischemic Attack — Proposal for a New Definition
Albers, G. W., Caplan, L. R., Easton, J. D., Fayad, P. B., Mohr, J. P., Saver, J. L., & Sherman, D. G. (2002) · New England Journal of Medicine · doi:10.1056/nejmsb020987 · Cited by 840 · cited 1×
“[16] The more recent, alternative ‘tissue-based’ definition relies on the presence of brain infarction to diagnose stroke, irrespective of symptom duration (<24hours).[20] Accurate diagnosis of brain infarction depends on the availability, choice, and timing of brain imaging, which may vary between different centres.”
BackgroundRosamond, W. D., Folsom, A. R., Chambless, L. E., Wang, C.-H., McGovern, P. G., Howard, G., Copper, L. S., & Shahar, E. (1999) · Stroke · doi:10.1161/01.str.30.4.736 · Cited by 811
Systematic review of discharge coding accuracy
Burns, E. M., Rigby, E., Mamidanna, R., Bottle, A., Aylin, P., Ziprin, P., & Faiz, O. D. (2012) · Journal of Public Health · doi:10.1093/pubmed/fdr054 · Cited by 690
Surveillance and ascertainment of cardiovascular events
Ives, D. G., Fitzpatrick, A. L., Bild, D. E., Psaty, B. M., Kuller, L. H., Crowley, P. M., Cruise, R. G., & Theroux, S. (1995) · Annals of Epidemiology · doi:10.1016/1047-2797(94)00093-9 · Cited by 688
Validity of diagnostic coding within the General Practice Research Database: a systematic review
Khan, N. F., Harrison, S. E., & Rose, P. W. (2010) · British Journal of General Practice · doi:10.3399/bjgp10x483562 · Cited by 685
Validating Administrative Data in Stroke Research
Tirschwell, D. L., & Longstreth, W. T. (2002) · Stroke · doi:10.1161/01.str.0000032240.28636.bd · Cited by 658 · cited 19×
“Very few studies assessed accuracy of ICD codes for more detailed ischaemic stroke subtypes, and none assessed accuracy for subtypes of SAH or ICH. doi:10.1371/journal.pone.0140533.g003 PLOS ONE | DOI:10.1371/journal.pone.0140533 October 23, 2015 10 / 20 One study found that out of 106 coded events for ischaemic strok…”
BackgroundMethodInfluentialFiebach, J. B., Schellinger, P. D., Jansen, O., Meyer, M., Wilde, P., Bender, J., Schramm, P., Jüttler, E., Oehler, J., Hartmann, M., et al. (2002) · Stroke · doi:10.1161/01.str.0000026864.20339.cb · Cited by 507
The Read clinical classification.
Chisholm, J. (1990) · BMJ · doi:10.1136/bmj.300.6732.1092 · Cited by 504 · cited 1×
“Primary care data in the UK are coded by general practitioners using the Read coding system, which encodes diagnoses, symptoms, signs, procedures, prescriptions and other administrative data [17, 18].”
MethodGoldstein, L. B. (1998) · Stroke · doi:10.1161/01.str.29.8.1602 · Cited by 408
Validity of Stroke Diagnoses in a National Register of Patients
Krarup, L.-H., Boysen, G., Janjua, H., Prescott, E., & Truelsen, T. (2007) · Neuroepidemiology · doi:10.1159/000102143 · Cited by 366 · cited 3×
“Johnsen [44] I63 Ischaemic stroke 113 88 (80–93) 2002 I64 Unspecified stroke 200 70 (63–76) I63, I64 Ischaemic and unspecified stroke 313 76 (71–80) Wright [57] I63 Ischaemic stroke 190 86 (81–91) 2012 I64 Unspecified stroke 119 66 (57–73) I63, I64 Ischaemic and unspecified stroke 309 78 (73–83) Ellekjaer [48] 434 Isc…”
BackgroundSystematic review of scope and quality of electronic patient record data in primary care
Thiru, K., Hassey, A., & Sullivan, F. (2003) · BMJ · doi:10.1136/bmj.326.7398.1070 · Cited by 342
Benesch, C., Witter, D. M., Wilder, A. L., Duncan, P. W., Samsa, G. P., & Matchar, D. B. (1997) · Neurology · doi:10.1212/wnl.49.3.660 · Cited by 331 · cited 5×
“For identifying ischaemic stroke, codes I63 (ICD-10) or 434 (ICD-9) achieved reasonably high PPVs (range 66 to 88%) [33, 42–44, 49, 53, 57], while code 433 (ICD-9) performed consistently poorly in studies which assessed it (PPV range 6% to 14%) [33, 43, 49].”
BackgroundInfluentialSchulz, U. G. R., & Rothwell, P. M. (2003) · Stroke · doi:10.1161/01.str.0000079818.08343.8c · Cited by 312 · cited 1×
“[77, 78] Fifth, the paucity of specific published data about the accuracy of Read-coded primary care data for stroke is an important further limitation, since up to half of stroke patients are not admitted to hospital in the UK [79, 80], and hospitalised and non-hospitalised strokes may differ in the distribution of p…”
BackgroundWardlaw, J. M., & Mielke, O. (2005) · Radiology · doi:10.1148/radiol.2352040262 · Cited by 308 · cited 1×
“Even experts are inconsistent in their ability to diagnose stroke,[76], and choice and timing of imaging (which may vary between centres and therefore between studies) influences the diagnostic accuracy of stroke types.[77, 78] Fifth, the paucity of specific published data about the accuracy of Read-coded primary care…”
BackgroundA systematic review of discharge coding accuracy
Campbell, S. E., Campbell, M. K., Grimshaw, J. M., & Walker, A. E. (2001) · Journal of Public Health · doi:10.1093/pubmed/23.3.205 · Cited by 299
Andrade, S. E., Harrold, L. R., Tjia, J., Cutrona, S. L., Saczynski, J. S., Dodd, K. S., Goldberg, R. J., & Gurwitz, J. H. (2012) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.2312 · Cited by 268
Validity of myocardial infarction diagnoses in administrative databases: a systematic review.
McCormick, N., Lacaille, D., Bhole, V., & Avina-Zubieta, J. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0092286 · Cited by 262
Burton, P. R., Hansell, A. L., Fortier, I., Manolio, T. A., Khoury, M. J., Little, J., & Elliott, P. (2009) · International Journal of Epidemiology · doi:10.1093/ije/dyn147 · Cited by 258 · cited 1×
“Very large prospective studies, yielding large numbers of stroke cases, are needed to examine these associations reliably [4].”
BackgroundAccuracy of hospital discharge abstracts for identifying stroke.
Leibson, C. L., Naessens, J. M., Brown, R. D., & Whisnant, J. P. (1994) · Stroke · doi:10.1161/01.str.25.12.2348 · Cited by 208 · cited 3×
“Furthermore, the relevant studies were of ICD-9 codes only, which are now rarely used outside the USA.[31, 32, 34, 37, 40, 43, 49, 52] Thus, use of appropriately selected codes in both the primary and secondary positions would seem appropriate for most purposes.”
BackgroundQuality of morbidity coding in general practice computerized medical records: a systematic review
Jordan, K. (2004) · Family Practice · doi:10.1093/fampra/cmh409 · Cited by 199
Roumie, C. L., Mitchel, E., Gideon, P. S., Varas‐Lorenzo, C., Castellsague, J., & Griffin, M. R. (2008) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.1518 · Cited by 192 · cited 6×
“To identify stroke cases, the largest number of studies used the whole range of cerebrovascular disease codes (either with or without codes for transient ischaemic attack [TIA]) [31–33, 37–39, 44, 46, 48–51, 55, 56, 61, 62, 65], but others used stroke-specific codes [34, 44, 46, 48, 49].”
BackgroundMethodInfluentialTolonen, H., Salomaa, V., Torppa, J., Sivenius, J., Immonen-Räihä, P., Lehtonen, A., & Finstroke, R. (2007) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/01.hjr.0000239466.26132.f2 · Cited by 176
Johnsen, S. P., Overvad, K., Sørensen, H. T., Tjønneland, A., & Husted, S. E. (2002) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(02)00391-8 · Cited by 174 · cited 3×
“Johnsen [44] I63 Ischaemic stroke 113 88 (80–93) 2002 I64 Unspecified stroke 200 70 (63–76) I63, I64 Ischaemic and unspecified stroke 313 76 (71–80) Wright [57] I63 Ischaemic stroke 190 86 (81–91) 2012 I64 Unspecified stroke 119 66 (57–73) I63, I64 Ischaemic and unspecified stroke 309 78 (73–83) Ellekjaer [48] 434 Isc…”
BackgroundWahl, P. M., Rodgers, K., Schneeweiss, S., Gage, B. F., Butler, J., Wilmer, C., Nash, M., Esper, G., Gitlin, N., Osborn, N., et al. (2010) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.1924 · Cited by 174 · cited 1×
“[33, 36, 38, 39, 41, 45, 56, 58, 59, 64] With respect to generalisability to the UK population, only eight studies were conducted in the UK.”
BackgroundStegmayr, B., & Asplund, K. (1993) · Neuroepidemiology · doi:10.1159/000110933 · Cited by 162 · cited 5×
“[45, 48, 50, 64] Several within-study comparisons showed that the groups of codes with the highest PPVs (68–90%) for all types of stroke combined were 430, 431, 434, 436 (ICD-9) or I60, I61, I63, I64 (ICD-10) (Table 1).”
BackgroundMethodInfluentialImportance of accurately identifying disease in studies using electronic health records
Manuel, D. G., Rosella, L. C., & Stukel, T. A. (2010) · BMJ · doi:10.1136/bmj.c4226 · Cited by 159
Dixon, J., Sanderson, C., Elliott, P., Walls, P., Jones, J., & Petticrew, M. (1998) · Journal of Public Health · doi:10.1093/oxfordjournals.pubmed.a024721 · Cited by 159
Diagnosis of Transient Ischemic Attack by the Nonneurologist: A Validation Study
Ferro, J. M., Falcão, I., Rodrigues, G., Canhão, P., Melo, T. P., Oliveira, V., Pinto, A. N., Crespo, M., & Salgado, A. V. (1996) · Stroke · doi:10.1161/01.str.27.12.2225 · Cited by 158
van Staa, T. P., & Abenhaim, L. (1994) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.2630030106 · Cited by 138
Jackson, C. A., Hutchison, A., Dennis, M. S., Wardlaw, J. M., Lindgren, A., Norrving, B., Anderson, C. S., Hankey, G. J., Jamrozik, K., Appelros, P., et al. (2010) · Stroke · doi:10.1161/strokeaha.109.558809 · Cited by 131
Self-citationTu, K., Wang, M., Young, J., Green, D., Ivers, N. M., Butt, D. A., Jaakkimainen, L., & Kapral, M. K. (2013) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2013.07.676 · Cited by 122 · cited 9×
“A few excluded studies compared primary care and hospital codes to search for stroke plus TIA [66, 67].”
BackgroundInfluentialIdentification of Incident Stroke in Norway
Ellekjær, H., Holmen, J., Krüger, Ø., & Terént, A. (1999) · Stroke · doi:10.1161/01.str.30.1.56 · Cited by 119
Reker, D. M., Hamilton, B. B., Duncan, P. W., Yeh, S. C., & Rosen, A. K. (2001) · PubMed · Cited by 118
Refinement of Swedish Administrative Registers to Monitor Stroke Events on the National Level
Köster, M., Asplund, K., Johansson, Å., & Stegmayr, B. (2013) · Neuroepidemiology · doi:10.1159/000345953 · Cited by 117 · cited 9×
“[45, 48, 50, 64] Several within-study comparisons showed that the groups of codes with the highest PPVs (68–90%) for all types of stroke combined were 430, 431, 434, 436 (ICD-9) or I60, I61, I63, I64 (ICD-10) (Table 1).”
BackgroundMethodInfluentialWhy are patients with acute stroke admitted to hospital?
Bamford, J., Sandercock, P. A., Warlow, C., & Gray, M. (1986) · BMJ · doi:10.1136/bmj.292.6532.1369 · Cited by 103 · cited 1×
“[77, 78] Fifth, the paucity of specific published data about the accuracy of Read-coded primary care data for stroke is an important further limitation, since up to half of stroke patients are not admitted to hospital in the UK [79, 80], and hospitalised and non-hospitalised strokes may differ in the distribution of p…”
BackgroundA language of health in action: Read Codes, classifications and groupings.
Stuart-Buttle, C. D. G., Read, J. D., Sanderson, H. F., & Sutton, Y. M. (1996) · Europe PMC (PubMed Central) · Cited by 96
Validation of ischemic cerebrovascular diagnoses in the health improvement network (THIN)
Ruigómez, A., Martín‐Merino, E., & Rodríguez, L. A. G. (2010) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.1919 · Cited by 89 · cited 14×
“(Table 1).”
BackgroundInfluentialLiu, L., Reeder, B. A., Shuaib, A. M., & Mazagri, R. S. (1999) · Cerebrovascular Diseases · doi:10.1159/000015960 · Cited by 89 · cited 4×
“Furthermore, the relevant studies were of ICD-9 codes only, which are now rarely used outside the USA.[31, 32, 34, 37, 40, 43, 49, 52] Thus, use of appropriately selected codes in both the primary and secondary positions would seem appropriate for most purposes.”
BackgroundInfluentialAboa-Éboulé, C., Mengue, D., Benzenine, É., Hommel, M., Giroud, M., Béjot, Y., & Quantin, C. (2012) · Journal of Neurology · doi:10.1007/s00415-012-6686-0 · Cited by 76 · cited 4×
“Several others used various miscellaneous groups of cerebrovascular codes to identify stroke cases [29, 30, 35, 36, 58, 59], while a further four did not include SAH in their definition of stroke and so excluded SAH codes [45, 54, 60, 64].”
BackgroundMethodInfluentialRisk of Hemorrhagic Stroke in Asian American Ethnic Groups
Klatsky, A. L., FRIEDMAN, G. D., Sidney, S., Kipp, H., Kubo, A., & Armstrong, M. A. (2005) · Neuroepidemiology · doi:10.1159/000085310 · Cited by 73 · cited 1×
“[33, 36, 38, 39, 41, 45, 56, 58, 59, 64] With respect to generalisability to the UK population, only eight studies were conducted in the UK.”
BackgroundMeasuring Accuracy of Discharge Diagnoses for a Region-Wide Surveillance of Hospitalized Strokes
Spolaore, P., Brocco, S., Fedeli, U., Visentin, C., Schievano, E., Avossa, F., Milan, G., Toso, V., Vanuzzo, D., Pilotto, L., et al. (2005) · Stroke · doi:10.1161/01.str.0000160755.94884.4a · Cited by 69
Validation of the Swedish inpatient and cause-of-death registers in the context of stroke
Appelros, P., & Terént, A. (2011) · Acta Neurologica Scandinavica · doi:10.1111/j.1600-0404.2010.01402.x · Cited by 66 · cited 12×
“[45, 48, 50, 64] Several within-study comparisons showed that the groups of codes with the highest PPVs (68–90%) for all types of stroke combined were 430, 431, 434, 436 (ICD-9) or I60, I61, I63, I64 (ICD-10) (Table 1).”
BackgroundMethodInfluentialCollaborators, F. T. M. W. S., Wright, F., Green, J., Canoy, D., Cairns, B. J., Balkwill, A., & Beral, V. (2012) · BMC Medical Research Methodology · doi:10.1186/1471-2288-12-161 · Cited by 62 · cited 22×
“Very few studies assessed accuracy of ICD codes for more detailed ischaemic stroke subtypes, and none assessed accuracy for subtypes of SAH or ICH. doi:10.1371/journal.pone.0140533.g003 PLOS ONE | DOI:10.1371/journal.pone.0140533 October 23, 2015 10 / 20 One study found that out of 106 coded events for ischaemic strok…”
BackgroundInfluentialAccuracy of national mortality codes in identifying adjudicated cardiovascular deaths
Harriss, L. R., Ajani, A. E., Hunt, D. U., Shaw, J. A., Chambers, B. R., Dewey, H. M., Frayne, J. H., Beauchamp, A., Duvé, K., Giles, G. G., et al. (2011) · Australian and New Zealand Journal of Public Health · doi:10.1111/j.1753-6405.2011.00739.x · Cited by 61 · cited 4×
“They assessed ICD code versions 9 [29–43, 48–52, 55–62], 10 [44–46, 53, 54, 56, 57, 63], or both [47, 65].”
BackgroundMethodInfluentialCase ascertainment in stroke studies: the risk of selection bias
Appelros, P., Högerås, N., & Terént, A. (2003) · Acta Neurologica Scandinavica · doi:10.1034/j.1600-0404.2003.02120.x · Cited by 60
Gaist, D., Wallander, M.-A. A., González‐Pérez, A., & García‐Rodríguez, L. A. (2012) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.3391 · Cited by 51 · cited 15×
“(Table 1).”
BackgroundInfluentialGiroud, M., Lemesle, M., Quantin, C., Vourch, M., Becker, F., Milan, C., Brunet‐Lecomte, P., & Dumas, R. (1996) · Neuroepidemiology · doi:10.1159/000109666 · Cited by 46
The Accuracy of Hospital Discharge Coding for Hemorrhagic Stroke
Kirkman, M. A., Mahattanakul, W., GREGSON, B. A., & Mendelow, A. D. (2009) · PubMed · doi:10.25405/ncl.34100280 · Cited by 45
Accuracy of death certification and hospital record linkage for identification of incident stroke
Sinha, S., Myint, P. K., Luben, R., & Khaw, K. (2008) · BMC Medical Research Methodology · doi:10.1186/1471-2288-8-74 · Cited by 42
Derby, C. A., Lapane, K. L., Feldman, H. A., & Carleton, R. A. (2000) · Stroke · doi:10.1161/01.str.31.4.875 · Cited by 37
Rinaldi, R., Vignatelli, L., Galeotti, M., Azzimondi, G., & de Carolis, P. (2003) · Neurological Sciences · doi:10.1007/s100720300074 · Cited by 36 · cited 5×
“Johnsen [44] I63 Ischaemic stroke 113 88 (80–93) 2002 I64 Unspecified stroke 200 70 (63–76) I63, I64 Ischaemic and unspecified stroke 313 76 (71–80) Wright [57] I63 Ischaemic stroke 190 86 (81–91) 2012 I64 Unspecified stroke 119 66 (57–73) I63, I64 Ischaemic and unspecified stroke 309 78 (73–83) Ellekjaer [48] 434 Isc…”
BackgroundMethodInfluentialCan Hospital Discharge Databases Be Used to Follow Ischemic Stroke Incidence?
Haesebaert, J., Termoz, A., Polazzi, S., Mouchoux, C., Mechtouff, L., Derex, L., Nighoghossian, N., & Schott, A. (2013) · Stroke · doi:10.1161/strokeaha.113.001300 · Cited by 35
Béjot, Y., Mehta, Z., Giroud, M., & Rothwell, P. M. (2013) · Stroke · doi:10.1161/strokeaha.113.000949 · Cited by 34
Accuracy of the ICD-9 codes for identifying TIA and stroke in an Italian automated database
Leone, M. A., Capponi, A., Varrasi, C., Tarletti, R., & Monaco, F. (2004) · Neurological Sciences · doi:10.1007/s10072-004-0355-8 · Cited by 29 · cited 6×
“For identifying ischaemic stroke, codes I63 (ICD-10) or 434 (ICD-9) achieved reasonably high PPVs (range 66 to 88%) [33, 42–44, 49, 53, 57], while code 433 (ICD-9) performed consistently poorly in studies which assessed it (PPV range 6% to 14%) [33, 43, 49].”
BackgroundInfluentialStroke Rates: 1980-2000: The Minnesota Stroke Survey
Lakshminarayan, K., Anderson, D. C., Jacobs, D. R., Barber, C. A., & Luepker, R. V. (2009) · American Journal of Epidemiology · doi:10.1093/aje/kwp029 · Cited by 29
Flynn, R., MacDonald, T. M., Schembri, N., Murray, G. D., & Doney, A. S. F. (2010) · Pharmacoepidemiology and Drug Safety · doi:10.1002/pds.1981 · Cited by 27
Palmieri, L., Barchielli, A., Cesana, G., Campora, E. D., Goldoni, C. A., Spolaore, P., Uguccioni, M., Vancheri, F., Vanuzzo, D., Ciccarelli, P., et al. (2007) · Cerebrovascular Diseases · doi:10.1159/000110423 · Cited by 24 · cited 2×
“Most studies used hospital data only, but one was of death certificates only [65], and six used both [40, 45, 47, 50, 55, 56].”
MethodThe Quality of Diagnostic Coding in Cerebrovascular Disease
Hasan, M., Meara, R. J., & Bhowmick, B. K. (1995) · International Journal for Quality in Health Care · doi:10.1093/intqhc/7.4.407 · Cited by 24 · cited 1×
“Of the UKbased studies, two had suboptimal generalisability because all coded discharges were taken from a single hospital department, [61, 62] while for the other six generalisability was unclear due to incomplete reporting.”
BackgroundThe accuracy of Scottish Morbidity Record (SMR1) data for identifying hospitalised stroke patients.
Davenport, R., Dennis, M. S., & Warlow, C. P. (1996) · PubMed · Cited by 21
Identification of stroke in the community: a comparison of three methods.
Mant, J., McManus, R. J., Hare, R., & Mayer, P. P. (2003) · Europe PMC (PubMed Central) · Cited by 19
Transient Ischemic Attack — Proposed New Definition
Brown, M. M., Rudd, A., & McGovern, R. (2003) · New England Journal of Medicine · doi:10.1056/nejm200304173481621 · Cited by 16 · cited 1×
“[20] Accurate diagnosis of brain infarction depends on the availability, choice, and timing of brain imaging, which may vary between different centres.[21] We chose to use the ‘symptom-based’ definition to maximise comparability between different studies.”
MethodInterrater Reliability in the Assessment of Neurovascular Diseases
Kessler, C., Freyberger, H. J., Dittmann, V., & Ringelstein, E. B. (1990) · Cerebrovascular Diseases · doi:10.1159/000108815 · Cited by 16 · cited 1×
“Furthermore, the few available studies of ICD-coded data sources for identification of ischaemic stroke subtypes found that the majority of ischaemic subtype codes were ‘unspecified’[42], and reliability of ischaemic subtype classification was limited [74, 75].”
BackgroundPossible Effect of DRGs on the Classification of Stroke
Derby, C. A., Lapane, K. L., Feldman, H. A., & Carleton, R. A. (2001) · Stroke · doi:10.1161/01.str.32.7.1487 · Cited by 14 · cited 2×
“[33, 36, 38, 39, 41, 45, 56, 58, 59, 64] With respect to generalisability to the UK population, only eight studies were conducted in the UK.”
BackgroundBarer, D. H., Ellul, J., & Watkins, C. L. (1996) · BMJ · doi:10.1136/bmj.313.7063.1005c · Cited by 3
The Accuracy of Diagnostic Classification of Cerebrovascular Disease (Cvd)
Panayiotou, B., Fotherby, M. D., Harper, G., Potter, J., & Castleden, C. M. (1993) · Clinical Science · doi:10.1042/cs085013pb · Cited by 1
Research works printed but not linked: 4
- N Mayo, 1993, Accuracy of Hospital discharge coding for stroke, Can J Cardiol, 9, 121D
- J Mant, 1997, How good is routine information? Validation of coding for acute stroke in Oxford hospitals, Health Trends, 29, 96
- B Panayiotou, 1993, The accuracy of diagnostic coding of cerebrovascular disease, Medical Audit News, 3, 153
- JM Ferro, 1996, Diagnosis of Transient Ischaemic Attack by the non-neurologist. A validation study, Stroke, 27, 2225, 10.1161/01.STR.27.12.2225 · DOI · Paper page
Cited by
Acosta, J. N., Falcone, G. J., Rajpurkar, P., & Topol, E. J. (2022) · Nature Medicine · doi:10.1038/s41591-022-01981-2 · Cited by 1,365
Said, M. A., Verweij, N., & van der Harst, P. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.1717 · Cited by 641
Biobank, O. B. O. D. P. U. A. U., Wilkinson, T., Schnier, C., Bush, K., Rannikmäe, K., Henshall, D. E., Lerpiniere, C., Allen, N. E., Flaig, R., Russ, T. C., et al. (2019) · European Journal of Epidemiology · doi:10.1007/s10654-019-00499-1 · Cited by 452
Self-citationBanks, E., Joshy, G., Korda, R. J., Stavreski, B., Soga, K., Egger, S., Day, C., Clarke, N. E., Lewington, S., & Lopez, A. D. (2019) · BMC Medicine · doi:10.1186/s12916-019-1351-4 · Cited by 319
Descatha, A., Sembajwe, G. N., Pega, F., Ujita, Y., Baer, M., Boccuni, F., Tecco, C. D., Duret, C., Evanoff, B., Gagliardi, D., et al. (2020) · Environment International · doi:10.1016/j.envint.2020.105746 · Cited by 167
“Supporting our assessment of low risk, Kivimaki et al. (2015a) found no difference in their sensitivity analyses between self-reported and administrative records, which was similar to Wong et al. (2019), and the fair accuracy reported by other studies (Woodfield et al., 2015a, 2015b).”
BackgroundResult
Metadata
- Authors
- Woodfield, R., Grant, I., UK Biobank Stroke Outcomes Group, UK Biobank Follow-Up and Outcomes Working Group, & Sudlow, C. L. M.
- Affiliations
- University of Edinburgh (GB)
- National Health Service Scotland (GB)
- UK Biobank (GB)
- Corresponding author
- Sudlow, Cathie L. M.
- ORCID
- Sudlow, Cathie L. M.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2015-10-23
- Volume
- 10
- Issue
- 10
- Pages
- e0140533
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC4619732
- OpenAlex
- W2114176457
- Semantic Scholar
- 8ea6f3c77795ef6e5a1bf43993cf0ff629cad481
- Cited by
- 145
- References
- 74
- Citations by year
- 2026: 13 · 2025: 13 · 2024: 23 · 2023: 16 · 2022: 11 · 2021: 18 · 2020: 8 · 2019: 16 · 2018: 13 · 2017: 8 · 2016: 6
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- Edinburgh Research Explorer (University of Edinburgh) (submittedVersion, cc-by)
- Funders
- University of Dundee
- Wellcome Trust (093707)
- Cancer Research UK
- University of Cambridge
- University College London
- University of Oxford
- University of Nottingham
- Cardiff University
- Swansea University
- Moorfields Eye Hospital NHS Foundation Trust
- Medical Research Council (MR/K007017/1)
- Menzies Centre for Australian Studies, King's College London, University of London
- Topics
- Health Sciences › Health Professions › Health Information Management › Medical Coding and Health Information
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Health Sciences › Medicine › Clinical Neurology › Acute Ischemic Stroke Management
- Keywords
- stroke, electronic health records, case finding, data linkage, ICD codes, ischemic stroke, intracerebral hemorrhage, subarachnoid hemorrhage, positive predictive value, hospitalization, death certificates, primary care data, UK Biobank, long-term follow-up
- MeSH terms
- Adult, Death Certificates, United Kingdom, Hospitalization, Humans, Middle Aged, Reproducibility of Results, Stroke, International Classification of Diseases, Electronic Health Records
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.