Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 176

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Investigating Nonalcoholic Fatty Liver Disease in a Liver-on-a-Chip Microfluidic Device

Open access
Gori, Manuele, Simonelli, Maria Chiara, Giannitelli, Sara Maria, Businaro, Luca, Trombetta, Marcella, Rainer, Alberto · 2016 · PLOS ONE

Abstract

BACKGROUND AND AIM: Nonalcoholic fatty liver disease (NAFLD) is a chronic liver disease worldwide, ranging from simple steatosis to nonalcoholic steatohepatitis, which may progress to cirrhosis, eventually leading to hepatocellular carcinoma (HCC). HCC ranks as the third highest cause of cancer-related death globally, requiring an early diagnosis of NAFLD as a potential risk factor. However, the molecular mechanisms underlying NAFLD are still under investigation. So far, many in vitro studies on NAFLD have been hampered by the limitations of 2D culture systems, in which cells rapidly lose tissue-specific functions. The present liver-on-a-chip approach aims at filling the gap between conventional in vitro models, often scarcely predictive of in vivo conditions, and animal models, potentially biased by their xenogeneic nature. METHODS: HepG2 cells were cultured into a microfluidically perfused device under free fatty acid (FFA) supplementation, namely palmitic and oleic acid, for 24h and 48h. The device mimicked the endothelial-parenchymal interface of a liver sinusoid, allowing the diffusion of nutrients and removal of waste products similar to the hepatic microvasculature. Assessment of intracellular lipid accumulation, cell viability/cytotoxicity and oxidative stress due to the FFA overload, was performed by high-content analysis methodologies using fluorescence-based functional probes. RESULTS: The chip enables gradual and lower intracellular lipid accumulation, higher hepatic cell viability and minimal oxidative stress in microfluidic dynamic vs. 2D static cultures, thus mimicking the chronic condition of steatosis observed in vivo more closely. CONCLUSIONS: Overall, the liver-on-a-chip system provides a suitable culture microenvironment, representing a more reliable model compared to 2D cultures for investigating NAFLD pathogenesis. Hence, our system is amongst the first in vitro models of human NAFLD developed within a microfluidic device in a sinusoid-like fashion, endowing a more permissive tissue-like microenvironment for long-term culture of hepatic cells than conventional 2D static cultures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0159729

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 176

Metadata

Authors
Gori, M., Simonelli, M. C., Giannitelli, S. M., Businaro, L., Trombetta, M., & Rainer, A.
Venue
PLOS ONE
Published
2016-07-20
Volume
11
Issue
7
Pages
e0159729
ISSN
1932-6203 (ISSN-L)
OpenAlex
W2501678433
Cited by
176
References
8
FWCI
11.18
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Investigating Nonalcoholic Fatty Liver Disease in a Liver-on-a-Chip Microfluidic Device. https://app.cochat.ai/papers/10.1371/journal.pone.0159729
The paper
Gori, M., Simonelli, M. C., Giannitelli, S. M., Businaro, L., Trombetta, M., & Rainer, A. (2016). Investigating Nonalcoholic Fatty Liver Disease in a Liver-on-a-Chip Microfluidic Device. PLOS ONE. https://doi.org/10.1371/journal.pone.0159729

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.