The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Comparison of six electromyography acquisition setups on hand movement classification tasks
Open accessAbstract
Hand prostheses controlled by surface electromyography are promising due to the non-invasive approach and the control capabilities offered by machine learning. Nevertheless, dexterous prostheses are still scarcely spread due to control difficulties, low robustness and often prohibitive costs. Several sEMG acquisition setups are now available, ranging in terms of costs between a few hundred and several thousand dollars. The objective of this paper is the relative comparison of six acquisition setups on an identical hand movement classification task, in order to help the researchers to choose the proper acquisition setup for their requirements. The acquisition setups are based on four different sEMG electrodes (including Otto Bock, Delsys Trigno, Cometa Wave + Dormo ECG and two Thalmic Myo armbands) and they were used to record more than 50 hand movements from intact subjects with a standardized acquisition protocol. The relative performance of the six sEMG acquisition setups is compared on 41 identical hand movements with a standardized feature extraction and data analysis pipeline aimed at performing hand movement classification. Comparable classification results are obtained with three acquisition setups including the Delsys Trigno, the Cometa Wave and the affordable setup composed of two Myo armbands. The results suggest that practical sEMG tests can be performed even when costs are relevant (e.g. in small laboratories, developing countries or use by children). All the presented datasets can be used for offline tests and their quality can easily be compared as the data sets are publicly available.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breiman, L. (2001) · Machine Learning · doi:10.1023/a:1010933404324 · Cited by 133,538
The pascal visual object classes (VOC) challenge
Everingham, M., Van Gool, L., Williams, C. K. I., Winn, J., & Zisserman, A. (2010) · International Journal of Computer Vision · doi:10.1007/s11263-009-0275-4 · Cited by 19,599
An Introduction to Support Vector Machines and Other Kernel-based Learning Methods
Cristianini, N., & Shawe-Taylor, J. (2000) · doi:10.1017/cbo9780511801389 · Cited by 13,855
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“[37] (TD), Histogram (HIST) and marginal Discrete Wavelet Transform (mDWT) and the concatenation of all of them.”
BackgroundA robust, real-time control scheme for multifunction myoelectric control
Englehart, K., & Hudgins, B. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.813539 · Cited by 1,743
On grasp choice, grasp models, and the design of hands for manufacturing tasks
Cutkosky, M. R. (1989) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.34763 · Cited by 1,513
Farina, D., Jiang, N., Rehbaum, H., Holobar, A., Graimann, B., Dietl, H., & Aszmann, O. C. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2305111 · Cited by 992
Electromyography data for non-invasive naturally-controlled robotic hand prostheses
Atzori, M., Gijsberts, A., Castellini, C., Caputo, B., Hager, A.-G. M., Elsig, S., Giatsidis, G., Bassetto, F., & Müller, H. (2014) · Scientific Data · doi:10.1038/sdata.2014.53 · Cited by 969
Self-citationScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Atzori, M., Cognolato, M., & Müller, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00009 · Cited by 684 · cited 1×
“Offline data analysis on public benchmark datasets on the other hand can be performed by any researcher worldwide (including a wide community of scientists that are highly specialized in machine learning) and it allows the immediate comparison of different methods (including very recent ones [8]) and setups.”
BackgroundControl of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
What Does Classifying More Than 10,000 Image Categories Tell Us?
Deng, J., Berg, A. C., Li, K., & Fei-Fei, L. (2010) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-15555-0_6 · Cited by 486
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477 · cited 3×
“Five signal features are https://doi.org/10.1371/journal.pone.0186132.g004 PLOS ONE | https://doi.org/10.1371/journal.pone.0186132 October 12, 2017 11 / 17 computed for each window: Root-Mean-Square (RMS), time domain statistics described by Hudgins et al. [37] (TD), Histogram (HIST) and marginal Discrete Wavelet Tran…”
MethodInfluentialMyoelectric forearm prostheses: State of the art from a user-centered perspective
Peerdeman, B., Boere, D., Witteveen, H., Huis in `tVeld, R., Hermens, H., Stramigioli, S., Rietman, H., Veltink, P., & Misra, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.08.0161 · Cited by 469
EMG frequency spectrum, muscle structure, and fatigue during dynamic contractions in man
Komi, P. V., & Tesch, P. (1979) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421103 · Cited by 461
Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2007967 · Cited by 450
Quantifying Pattern Recognition—Based Myoelectric Control of Multifunctional Transradial Prostheses
Li, G., Schultz, A. E., & Kuiken, T. A. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2039619 · Cited by 443
Surface EMG in advanced hand prosthetics
Castellini, C., & van der Smagt, P. (2009) · Biological Cybernetics · doi:10.1007/s00422-008-0278-1 · Cited by 429
Control of Hand Prostheses Using Peripheral Information
Micera, S., Carpaneto, J., & Raspopovic, S. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2085429 · Cited by 403
Influence of anatomical, physical, and detection-system parameters on surface EMG
Farina, D., Cescon, C., & Merletti, R. (2002) · Biological Cybernetics · doi:10.1007/s00422-002-0309-2 · Cited by 373
Decoding of Individuated Finger Movements Using Surface Electromyography
Tenore, F. V. G., Ramos, A., Fahmy, A., Acharya, S., Etienne-Cummings, R., & Thakor, N. V. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005485 · Cited by 342
Characterization of a Benchmark Database for Myoelectric Movement Classification
Atzori, M., Gijsberts, A., Kuzborskij, I., Elsig, S., Mittaz Hager, A.-G., Deriaz, O., Castellini, C., Muller, H., & Caputo, B. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2328495 · Cited by 293
Self-citationJiang, N., Rehbaum, H., Vujaklija, I., Graimann, B., & Farina, D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2278411 · Cited by 269
Lucas, M.-F., Gaufriau, A., Pascual, S., Doncarli, C., & Farina, D. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.002 · Cited by 253
Patterns of Static Prehension in Normal Hands
Kamakura, N., Matsuo, M., Ishii, H., Mitsuboshi, F., & Miura, Y. (1980) · The American Journal of Occupational Therapy · doi:10.5014/ajot.34.7.437 · Cited by 249
Onset Detection in Surface Electromyographic Signals: A Systematic Comparison of Methods
Staude, G., Flachenecker, C., Daumer, M., & Wolf, W. (2001) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/s1110865701000191 · Cited by 211
Gijsberts, A., Atzori, M., Castellini, C., Muller, H., & Caputo, B. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2303394 · Cited by 199
Self-citationThe effect of subcutaneous fat on myoelectric signal amplitude and cross-talk
Kuiken, T. A., Lowery, M. M., & Stoykov, N. S. (2003) · Prosthetics & Orthotics International · doi:10.3109/03093640309167976 · Cited by 196
Atzori, M., & Müller, H. (2015) · Frontiers in Systems Neuroscience · doi:10.3389/fnsys.2015.00162 · Cited by 183
Self-citationAdvances in Surface EMG: Recent Progress in Detection and Processing Techniques
Merletti, R., Aventaggiato, M., Botter, A., Holobar, A., Marateb, H., & Vieira, T. M. M. (2010) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.v38.i4.10 · Cited by 176
Hargrove, L. J., Losier, Y. G., Lock, B. A., Englehart, K. B., & Hudgins, B. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353424 · Cited by 170
Overview of the CLEF 2009 Medical Image Retrieval Track
Müller, H., Kalpathy–Cramer, J., Eggel, I., Bedrick, S. D., Radhouani, S., Bakke, B., Kahn, C. E., & Hersh, W. (2010) · Lecture notes in computer science · doi:10.1007/978-3-642-15751-6_8 · Cited by 139
Self-citationOn the challenge of classifying 52 hand movements from surface electromyography
Kuzborskij, I., Gijsberts, A., & Caputo, B. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347099 · Cited by 126
Li, G., Li, Y., Yu, L., & Geng, Y. (2011) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0265-x · Cited by 109
The effect of perspiration on the sEMG amplitude and power spectrum
Abdoli-Eramaki, M., Damecour, C., Christenson, J., & Stevenson, J. M. (2012) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2012.04.009 · Cited by 100
Effect of clinical parameters on the control of myoelectric robotic prosthetic hands
Atzori, M., Gijsberts, A., Castellini, C., Barbara Caputo, B., Hager, A.-G. M., Elsig, S., Giatsidis, G., Bassetto, F., & Müller, H. (2016) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.09.0218 · Cited by 75
Self-citationMyocoder studies of multiple myopotential response.
Finley, F. R., & Wirta, R. W. (1967) · PubMed · Cited by 67
Developmental and Functional Hand Grasps
Edwards, S. J., Buckland, D. J., & McCoy-Powlen, J. D. (2002) · Medical Entomology and Zoology · Cited by 66
Jensen, W., Andersen, O. K., & Akay, M. (2014) · Biosystems & biorobotics · doi:10.1007/978-3-319-08072-7 · Cited by 57
Lidierth, M. (1986) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(86)90163-x · Cited by 47 · cited 1×
“the generalized likelihood ratio algorithm [30] and the Lidierth threshold based algorithm [31, 32]) were used to correct imperfect labeling.”
MethodClassification of hand movements in amputated subjects by sEMG and accelerometers
Atzori, M., Gijsberts, A., Müller, H., & Barbara Caputo, B. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944388 · Cited by 45
Self-citationAtzori, M., & Müller, H. (2014) · International Journal of Signal Processing Systems · doi:10.12720/ijsps.3.2.118-122 · Cited by 7
Self-citationDesign of a Subject-Specific EMG Model for Rehabilitation Movement
Vivian, M., Tagliapietra, L., Reggiani, M., Farina, D., & Sartori, M. (2014) · Biosystems & biorobotics · doi:10.1007/978-3-319-08072-7_112 · Cited by 4
Self-citation
Cited by
Deep Learning for Electromyographic Hand Gesture Signal Classification Using Transfer Learning
Cote-Allard, U., Fall, C. L., Drouin, A., Campeau-Lecours, A., Gosselin, C., Glette, K., Laviolette, F., & Gosselin, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2896269 · Cited by 738
A wearable biosensing system with in-sensor adaptive machine learning for hand gesture recognition
Moin, A., Zhou, A., Rahimi, A., Menon, A., Benatti, S., Alexandrov, G., Tamakloe, S., Ting, J., Yamamoto, N., Khan, Y., et al. (2020) · Nature Electronics · doi:10.1038/s41928-020-00510-8 · Cited by 680
Feature Extraction and Selection for Myoelectric Control Based on Wearable EMG Sensors
Phinyomark, A., N. Khushaba, R., & Scheme, E. (2018) · Sensors · doi:10.3390/s18051615 · Cited by 352
EMG Pattern Recognition in the Era of Big Data and Deep Learning
Phinyomark, A., & Scheme, E. (2018) · Big Data and Cognitive Computing · doi:10.3390/bdcc2030021 · Cited by 272
Maceira-Elvira, P., Popa, T., Schmid, A.-C., & Hummel, F. C. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0612-y · Cited by 265
Metadata
- Authors
- Pizzolato, S., Tagliapietra, L., Cognolato, M., Reggiani, M., Müller, H., & Atzori, M.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-10-12
- Volume
- 12
- Issue
- 10
- Pages
- e0186132
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2762706434
- Cited by
- 421
- References
- 44
- FWCI
- 11.29
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.