Personalized blood glucose prediction: A hybrid approach using grammatical evolution and physiological models
Open accessThe DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
The large patient variability in human physiology and the effects of variables such as exercise or meals challenge current prediction modeling techniques. Physiological models are very precise but they are typically complex and specific physiological knowledge is required. In contrast, data-based models allow the incorporation of additional inputs and accurately capture the relationship between these inputs and the outcome, but at the cost of losing the physiological meaning of the model. In this work, we designed a hybrid approach comprising physiological models for insulin and grammatical evolution, taking into account the clinical harm caused by deviations from the target blood glucose by using a penalizing fitness function based on the Clarke error grid. The prediction models were built using data obtained over 14 days for 100 virtual patients generated by the UVA/Padova T1D simulator. Midterm blood glucose was predicted for the 100 virtual patients using personalized models and different scenarios. The results obtained were promising; an average of 98.31% of the predictions fell in zones A and B of the Clarke error grid. Midterm predictions using personalized models are feasible when the configuration of grammatical evolution explored in this study is used. The study of new alternative models is important to move forward in the development of alarm-and-control applications for the management of type 1 diabetes and the customization of the patient's treatments. The hybrid approach can be adapted to predict short-term blood glucose values to detect continuous glucose-monitoring sensor errors and to estimate blood glucose values when the continuous glucose-monitoring system fails to provide them.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear model predictive control of glucose concentration in subjects with type 1 diabetes
Hovorka, R., Canonico, V., Chassin, L. J., Haueter, U., Massi-Benedetti, M., Federici, M. O., Pieber, T. R., Schaller, H. C., Schaupp, L., Vering, T., et al. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/010 · Cited by 1,274
O'Neill, M., & Ryan, C. (2001) · IEEE Transactions on Evolutionary Computation · doi:10.1109/4235.942529 · Cited by 951
The UVA/PADOVA Type 1 Diabetes Simulator: New Features
Man, C. D., Micheletto, F., Lv, D., Breton, M., Kovatchev, B., & Cobelli, C. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813514502 · Cited by 791
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
A review of personalized blood glucose prediction strategies for T1DM patients
Oviedo, S., Vehí, J., Calm, R., & Armengol, J. (2017) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2833 · Cited by 279
Self-citationPrevention of Nocturnal Hypoglycemia Using Predictive Alarm Algorithms and Insulin Pump Suspension
Buckingham, B., Chase, H. P., Dassau, E., Cobry, E., Clinton, P., Gage, V., Caswell, K., Wilkinson, J., Cameron, F., Lee, H., et al. (2010) · Diabetes Care · doi:10.2337/dc09-2303 · Cited by 169
Clinical accuracy of a continuous glucose monitoring system with an advanced algorithm
Bailey, T. S., Chang, A., & Christiansen, M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814559746 · Cited by 168
Diurnal Pattern of Insulin Action in Type 1 Diabetes
Hinshaw, L., Dalla Man, C., Nandy, D. K., Saad, A., Bharucha, A. E., Levine, J. A., Rizza, R. A., Basu, R., Carter, R. E., Cobelli, C., et al. (2013) · Diabetes · doi:10.2337/db12-1759 · Cited by 125
Circadian Variability of Insulin Sensitivity: Physiological Input for In Silico Artificial Pancreas
Visentin, R., Dalla Man, C., Kudva, Y. C., Basu, A., & Cobelli, C. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0192 · Cited by 113
Self-citationVisentin, R., Dalla Man, C., Kovatchev, B., & Cobelli, C. (2014) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0377 · Cited by 103
Self-citation
Cited by
Artificial intelligence for diabetes management and decision support: Literature review
Contreras, I., & Vehi, J. (2018) · Journal of Medical Internet Research · doi:10.2196/10775 · Cited by 560
Self-citationWoldaregay, A. Z., Årsand, E., Walderhaug, S., Albers, D., Mamykina, L., Botsis, T., & Hartvigsen, G. (2019) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2019.07.007 · Cited by 358
Advanced Diabetes Management Using Artificial Intelligence and Continuous Glucose Monitoring Sensors
Vettoretti, M., Cappon, G., Facchinetti, A., & Sparacino, G. (2020) · Sensors · doi:10.3390/s20143870 · Cited by 176
“A grammatical evolution algorithm for 60-min ahead, personalized, glucose concentration level prediction, that uses, as input features, the CGM data, the IOB and the carbohydrates rate-of-appearance over the past 2 h [62].”
MethodSelf-citationDeng, Y., Lu, L., Aponte, L., Angelidi, A. M., Novak, V., Karniadakis, G. E., & Mantzoros, C. S. (2021) · npj Digital Medicine · doi:10.1038/s41746-021-00480-x · Cited by 152
Prediction and prevention of hypoglycaemic events in type-1 diabetic patients using machine learning
Vehí, J., Contreras, I., Oviedo, S., Biagi, L., & Bertachi, A. (2020) · Health Informatics Journal · doi:10.1177/1460458219850682 · Cited by 76
“Previous studies have validated a module issuing continuous BG predictions using Databases 1, 2, and 3 28,47,48 that reported accurate real-time predictions.”
BackgroundMethodInfluentialSelf-citationContinuous glucose monitoring for hypoglycaemia in children: perspectives in 2020
Worth, C., Dunne, M., Ghosh, A., Harper, S., & Banerjee, I. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13029 · Cited by 37
“Significant improvements have been made with Contreras et al achieving an MARD of 12% and employing a glucose specific cost function which takes in to account the clinical harmfulness of deviations from euglycaemia.(82) Most recently Li et al used deep neural networks to achieve an MARD of 5% and 10% when their algori…”
MethodCamerlingo, N., Vettoretti, M., Del Favero, S., Cappon, G., Sparacino, G., & Facchinetti, A. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0139 · Cited by 22
Self-citation
Metadata
- Authors
- Contreras, I., Oviedo, S., Vettoretti, M., Visentin, R., & Vehí, J.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-11-07
- Volume
- 12
- Issue
- 11
- Pages
- e0187754
- ISSN
- 1932-6203 (ISSN-L)
- OpenAlex
- W2767819117
- Cited by
- 80
- References
- 14
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.