Assessment of automated analysis of portable oximetry as a screening test for moderate-to-severe sleep apnea in patients with chronic obstructive pulmonary disease
Open accessThe DOI matches its Crossref record; 59 of the 60 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The coexistence of obstructive sleep apnea syndrome (OSAS) and chronic obstructive pulmonary disease (COPD) leads to increased morbidity and mortality. The development of home-based screening tests is essential to expedite diagnosis. Nevertheless, there is still very limited evidence on the effectiveness of portable monitoring to diagnose OSAS in patients with pulmonary comorbidities. OBJECTIVE: To assess the influence of suffering from COPD in the performance of an oximetry-based screening test for moderate-to-severe OSAS, both in the hospital and at home. METHODS: A total of 407 patients showing moderate-to-high clinical suspicion of OSAS were involved in the study. All subjects underwent (i) supervised portable oximetry simultaneously to in-hospital polysomnography (PSG) and (ii) unsupervised portable oximetry at home. A regression-based multilayer perceptron (MLP) artificial neural network (ANN) was trained to estimate the apnea-hypopnea index (AHI) from portable oximetry recordings. Two independent validation datasets were analyzed: COPD versus non-COPD. RESULTS: The portable oximetry-based MLP ANN reached similar intra-class correlation coefficient (ICC) values between the estimated AHI and the actual AHI for the non-COPD and the COPD groups either in the hospital (non-COPD: 0.937, 0.909-0.956 CI95%; COPD: 0.936, 0.899-0.960 CI95%) and at home (non-COPD: 0.731, 0.631-0.808 CI95%; COPD: 0.788, 0.678-0.864 CI95%). Regarding the area under the receiver operating characteristics curve (AUC), no statistically significant differences (p >0.01) between COPD and non-COPD groups were found in both settings, particularly for severe OSAS (AHI ≥30 events/h): 0.97 (0.92-0.99 CI95%) non-COPD vs. 0.98 (0.92-1.0 CI95%) COPD in the hospital, and 0.87 (0.79-0.92 CI95%) non-COPD vs. 0.86 (0.75-0.93 CI95%) COPD at home. CONCLUSION: The agreement and the diagnostic performance of the estimated AHI from automated analysis of portable oximetry were similar regardless of the presence of COPD both in-lab and at-home. Particularly, portable oximetry could be used as an abbreviated screening test for moderate-to-severe OSAS in patients with COPD.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The study by Andrés-Blanco et al., a level 1b study, was a prospective single center in 193 COPD patients, where supervised portable oximetry was compared simultaneously to in-hospital PSG as well as to unsupervised portable oximetry at home.625 A control group of 100 non-COPD patients was also included. An ODI4% cutoff was used for the oximeter. There were no significant differences between COPD”
From International Consensus Statement on Obstructive Sleep Apnea (2023) · cites this paper as [625]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277
Pattern Recognition and Machine Learning
(2007) · Kybernetes · doi:10.1108/03684920710743466 · Cited by 8,265
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
(2007) · Cited by 6,530
Adult Obstructive Sleep Apnea Task Force of the American Academy of Sleep Medicine, Epstein, L. J., Kristo, D., Strollo, P. J., Friedman, N., Malhotra, A., Patil, S. P., Ramar, K., Rogers, R., Schwab, R. J., et al. (2009) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27497 · Cited by 3,360
Kapur, V. K., Auckley, D. H., Chowdhuri, S., Kuhlmann, D. C., Mehra, R., Ramar, K., & Harrod, C. G. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6506 · Cited by 3,253
Efficient Feature Selection via Analysis of Relevance and Redundancy
Yu, L., & Liu, H. (2004) · doi:10.5555/1005332.1044700 · Cited by 1,983
Applied Multivariate Data Analysis
Jobson, J. D. (1992) · Springer Texts in Statistics · doi:10.1007/978-1-4612-0921-8 · Cited by 1,825
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · Radiology · doi:10.1148/radiol.2015151516 · Cited by 1,337
Risk Factors for Obstructive Sleep Apnea in Adults
Young, T. (2004) · JAMA · doi:10.1001/jama.291.16.2013 · Cited by 1,216
Netlab: Algorithms for Pattern Recognition
Nabney, I. T. (2002) · Cited by 1,161
Collop, N. A., Anderson, W. M., Boehlecke, B. A., Claman, D. M., Goldberg, R., Gottlieb, D. J., Hudgel, D. W., Sateia, M. J., & Schwab, R. (2007) · PubMed Central · Cited by 1,082
STARD 2015: An Updated List of Essential Items for Reporting Diagnostic Accuracy Studies
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.246280 · Cited by 984
Vogelmeier, C. F., Criner, G. J., Martinez, F. J., Anzueto, A., Barnes, P. J., Bourbeau, J., Celli, B. R., Chen, R., Decramer, M., Fabbri, L. M., et al. (2017) · Respirology · doi:10.1111/resp.13012 · Cited by 681
Methods for Obtaining and Analyzing Unattended Polysomnography Data for a Multicenter Study
Sleep Heart Health Research Group, Redline, S., Sanders, M. H., Lind, B. K., Quan, S. F., Iber, C., Gottlieb, D. J., Bonekat, W. H., Rapoport, D. M., Smith, P. L., et al. (1998) · Sleep · doi:10.1093/sleep/21.7.759 · Cited by 531
Qaseem, A., Dallas, P., Owens, D. K., Starkey, M., Holty, J.-E. C., Shekelle, P., & for the Clinical Guidelines Committee of the American College of Physicians* (2014) · Annals of Internal Medicine · doi:10.7326/m12-3187 · Cited by 516
EEG complexity as a measure of depth of anesthesia for patients
Zhang, X.-S., Roy, R. J., & Jensen, E. W. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.966601 · Cited by 495
Overnight Pulse Oximetry for Sleep-Disordered Breathing in Adults
Netzer, N., Eliasson, A. H., Netzer, C., & Kristo, D. A. (2001) · Chest · doi:10.1378/chest.120.2.625 · Cited by 311
Epstein, L. J., Kristo, D. A., Strollo, P. J., Friedman, N. R., Malhotra, A., Patil, S. P., Ramar, K., Rogers, R. R., Schwab, R. J., Weaver, E. M., et al. (2009) · Cited by 298
Chung, F., Liao, P., Elsaid, H., Islam, S., Shapiro, C. M., & Sun, Y. (2012) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318248f4f5 · Cited by 243
McNicholas, W. T. (2017) · Chest · doi:10.1016/j.chest.2017.04.160 · Cited by 206
Prediction of the Apnea-Hypopnea Index From Overnight Pulse Oximetry *
Magalang, U. J., Dmochowski, J., Veeramachaneni, S., Draw, A., Mador, M. J., El-Solh, A., & Grant, B. J. B. (2003) · Chest · doi:10.1378/chest.124.5.1694 · Cited by 189
Applying continuous chaotic modeling to cardiac signal analysis
Cohen, M. E., Hudson, D. L., & Deedwania, P. C. (1996) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.537065 · Cited by 181
Clinical Phenotypes and Comorbidity in European Sleep Apnoea Patients
Saaresranta, T., Hedner, J., Bonsignore, M. R., Riha, R. L., McNicholas, W. T., Penzel, T., Anttalainen, U., Kvamme, J. A., Pretl, M., Sliwinski, P., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0163439 · Cited by 154
Multivariate Analysis of Blood Oxygen Saturation Recordings in Obstructive Sleep Apnea Diagnosis
Álvarez, D., Hornero, R., Marcos, J. V., & del Campo, F. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2056924 · Cited by 153
Self-citationExtraction of spectral based measures from MEG background oscillations in Alzheimer's disease
Poza, J., Hornero, R., Abásolo, D., Fernández, A., & García, M. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.006 · Cited by 142
Self-citationDevelopment of a Screening Tool for Sleep Disordered Breathing in Children Using the Phone Oximeter™
Garde, A., Dehkordi, P., Karlen, W., Wensley, D., Ansermino, J. M., & Dumont, G. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112959 · Cited by 134
Zamarrón, C., Gudé, F., González‐Barcala, F. J., Rodriguez, J. R., & Romero, P. V. (2003) · CHEST Journal · doi:10.1378/chest.123.5.1567 · Cited by 107
Automated detection of sleep apnea from electrocardiogram signals using nonlinear parameters
Acharya, U. R., Chua, E. C.-P., Faust, O., Lim, T., & Lim, L. F. B. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/3/002 · Cited by 99
Utility of AdaBoost to Detect Sleep Apnea-Hypopnea Syndrome From Single-Channel Airflow
Gutiérrez‐Tobal, G. C., Álvarez, D., del Campo, F., & Hornero, R. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2467188 · Cited by 77
Self-citationÁlvarez, D., Hornero, R., Marcos, J. V., Wessel, N., Penzel, T., Glos, M., & del Campo, F. (2013) · International Journal of Neural Systems · doi:10.1142/s0129065713500202 · Cited by 75
Self-citationApplied Multivariate Data Analysis, Volume I: Regression and Experimental Design
Kianifard, F. (1992) · Technometrics · doi:10.1080/00401706.1992.10484965 · Cited by 73
Marcos, J. V., Hornero, R., Álvarez, D., del Campo, F., Zamarrón, C., & Lopez, M. (2008) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2008.05.006 · Cited by 71
Self-citationPortable Monitoring for the Diagnosis of OSA
Cooksey, J. A., & Balachandran, J. S. (2015) · CHEST Journal · doi:10.1378/chest.15-1076 · Cited by 66
Does Oximetry Contribute to the Detection of Apneic Events?
Pépin, J., Levy, P. A., Lepaulle, B., Brambilla, C., & Guilleminault, C. (1991) · CHEST Journal · doi:10.1378/chest.99.5.1151 · Cited by 62
Marcos, J. V., Hornero, R., Álvarez, D., del Campo, F., & Aboy, M. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0646-6 · Cited by 62
Self-citationAutomated Prediction of the Apnea-Hypopnea Index from Nocturnal Oximetry Recordings
Marcos, J. V., Hornero, R., Álvarez, D., Aboy, M., & Del Campo, F. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2167971 · Cited by 61
Self-citationReal-Time Automatic Apneic Event Detection Using Nocturnal Pulse Oximetry
Jung, D. W., Hwang, S. H., Cho, J. G., Choi, B. H., Baek, H. J., Lee, Y. J., Jeong, D.-U., & Park, K. S. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2715405 · Cited by 61
Oxygen saturation regularity analysis in the diagnosis of obstructive sleep apnea
del Campo, F., Hornero, R., Zamarrón, C., Abasolo, D. E., & Álvarez, D. (2006) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2005.10.005 · Cited by 56
Self-citationProbabilistic neural network approach for the detection of SAHS from overnight pulse oximetry
Morillo, D., & Gross, N. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0995-4 · Cited by 55
Álvarez, D., Hornero, R., Marcos, J. V., & del Campo, F. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.009 · Cited by 54
Self-citationValidity of Neural Network in Sleep Apnea
El-Solh, A. A., Mador, M. J., Ten-Brock, E., Shucard, D. W., Abul-Khoudoud, M., & Grant, B. J. B. (1999) · Sleep · doi:10.1093/sleep/22.1.105 · Cited by 50
Effectiveness of Home Single-Channel Nasal Pressure for Sleep Apnea Diagnosis
Masa, J. F., Duran-Cantolla, J., Capote, F., Cabello, M., Abad, J., Garcia-Rio, F., Ferrer, A., Mayos, M., Gonzalez-Mangado, N., de la Peña, M., et al. (2014) · Sleep · doi:10.5665/sleep.4248 · Cited by 50
Dawson, A., Loving, R. T., Gordon, R. M., Abel, S. L., Loewy, D., Kripke, D. F., & Kline, L. E. (2015) · BMJ Open · doi:10.1136/bmjopen-2015-007956 · Cited by 49
Nigro, C. A., Dibur, E., Aimaretti, S., González, S., & Rhodius, E. E. (2010) · Sleep And Breathing · doi:10.1007/s11325-010-0421-9 · Cited by 46
Update on obstructive sleep apnea and its relation to COPD
Ezzie, M. E., & Mieczkowski, B. P. (2014) · International Journal of COPD · doi:10.2147/copd.s42394 · Cited by 46
Pattern recognition in airflow recordings to assist in the sleep apnoea–hypopnoea syndrome diagnosis
Gutiérrez‐Tobal, G. C., Álvarez, D., Marcos, J. V., del Campo, F., & Hornero, R. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-013-1109-7 · Cited by 45
Self-citationOliveira, M. G., Nery, L. E., Santos-Silva, R., Sartori, D. E., Alonso, F. F., Togeiro, S. M., Tufik, S., & Bittencourt, L. (2012) · Sleep Medicine · doi:10.1016/j.sleep.2012.06.011 · Cited by 45
Effectiveness of sequential automatic-manual home respiratory polygraphy scoring
Masa, J. F., Corral, J., Pereira, R., Duran-Cantolla, J., Cabello, M., Hernández-Blasco, L., Monasterio, C., Alonso-Fernandez, A., Chiner, E., Vázquez-Polo, F.-J., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00186811 · Cited by 44
A prediction model based on artificial neural networks for the diagnosis of obstructive sleep apnea
Karamanlı, H., Yalçinöz, T., Yalcinoz, M. A., & Yalcinoz, T. (2015) · Sleep And Breathing · doi:10.1007/s11325-015-1218-7 · Cited by 36
Regression and experimental design
Jobson, J. D. (1991) · Springer eBooks · Cited by 35
Scott, A. S., Baltzan, M. A., & Wolkove, N. (2014) · Canadian Respiratory Journal · doi:10.1155/2014/948717 · Cited by 33
Trends in sleep studies performed for Medicare beneficiaries
Chiao, W., & Durr, M. L. (2017) · The Laryngoscope · doi:10.1002/lary.26736 · Cited by 26
Predictive factors warrant screening for obstructive sleep apnea in COPD: a Taiwan National Survey
Yu, C., Hang, L., Hsu, J., Chang, C., Wang, H., Cheng, S.-L., Lin, C., Chan, M.-C., Wang, C.-C., & Perng, D. (2016) · International Journal of COPD · doi:10.2147/copd.s96504 · Cited by 24
To sleep, or not to sleep – that is the question, for polysomnography
Corlăteanu, A., Covanţev, S., Botnaru, V., Sircu, V., & Nenna, R. (2017) · Breathe · doi:10.1183/20734735.007717 · Cited by 15
Central Sleep Apnoea Is Related to the Severity and Short-Term Prognosis of Acute Coronary Syndrome
Florés, M., de Batlle, J., Sánchez-de-la-Torre, A., Sánchez‐de‐la‐Torre, M., Aldomá, A., Worner, F., Galera, E., Seminario, A., Torres, G., Dalmases, M., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0167031 · Cited by 14
Treptow, E. C., de Oliveira, M. G., Moreira, G. A., Togeiro, S. M., Nery, L. E., Tufik, S. B., & Bittencourt, L. (2015) · World Journal of Respirology · doi:10.5320/wjr.v5.i1.17 · Cited by 5
Cited by
International Consensus Statement on Obstructive Sleep Apnea
Chang, J. L., Goldberg, A. N., Alt, J. A., Mohammed, A., Ashbrook, L., Auckley, D., Ayappa, I., Bakhtiar, H., Barrera, J. E., Bartley, B. L., et al. (2023) · International Forum of Allergy & Rhinology · doi:10.1002/alr.23079 · Cited by 350
Deep learning for obstructive sleep apnea diagnosis based on single channel oximetry
Levy, J., Álvarez, D., Campo, F. D., & Behar, J. A. (2023) · Nature Communications · doi:10.1038/s41467-023-40604-3 · Cited by 126
Self-citationApplication of artificial intelligence in the diagnosis of sleep apnea
Bazoukis, G., Bollepalli, S. C., Chung, C. T., Li, X., Tse, G., Bartley, B. L., Batool‐Anwar, S., Quan, S. F., & Armoundas, A. A. (2023) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.10532 · Cited by 116
Temirbekoy, D., Güneş, S., Yazıcı, Z. M., & Sayın, İ. (2018) · Türk otorinolarengoloji arşivi · doi:10.5152/tao.2018.3025 · Cited by 79
A machine learning-based test for adult sleep apnoea screening at home using oximetry and airflow
Álvarez, D., Cerezo-Hernández, A., Crespo, A., Gutiérrez‐Tobal, G. C., Vaquerizo-Villar, F., Barroso-García, V., Moreno, F., Domingo, C. A. A., Albi, T. R., Hornero, R., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-62223-4 · Cited by 91
Self-citation
Metadata
- Authors
- Andrés-Blanco, A. M., Álvarez, D., Crespo, A., Arroyo, C. A., Cerezo-Hernández, A., Gutiérrez-Tobal, G. C., Hornero, R., & del Campo, F.
- Affiliations
- Hospital Universitario Río Hortega (ES)
- Universidad de Valladolid (ES)
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2017-11-27
- Volume
- 12
- Issue
- 11
- Pages
- e0188094
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC5703515
- OpenAlex
- W2769038041
- Cited by
- 28
- References
- 60
- Citations by year
- 2026: 2 · 2025: 2 · 2023: 4 · 2022: 6 · 2021: 3 · 2020: 5 · 2019: 3 · 2018: 3
- FWCI
- 2.22
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Hispana (publishedVersion, cc-by-nc-nd)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Figshare (submittedVersion, cc-by)
- UVaDOC UVaDOC University of Valladolid Documentary Repository (University of Valladolid) (submittedVersion, cc-by-nc-nd)
- Funders
- Sociedad Española de Neumología y Cirugía Torácica (ES) (265/2012)
- Ministerio de Economía y Competitividad (RTC-2015-3446-1, TEC2014-53196-R)
- European Regional Development Fund (0378_AD_EEGWA_2_P)
- Consejería de Educación, Junta de Castilla y León (VA037U16)
- Consejería de Sanidad, Junta de Castilla y León (GRS 752/A/13)
- Ministerio de Economía y Competitividad (ES) (IJCI-2014-22664)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Obstructive Sleep Apnea Research
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Chronic Obstructive Pulmonary Disease (COPD) Research
- Social Sciences › Psychology › Experimental and Cognitive Psychology › Sleep and related disorders
- Keywords
- obstructive sleep apnea, chronic obstructive pulmonary disease, apnea-hypopnea index estimation, artificial neural networks, multilayer perceptron, polysomnography, home monitoring, COPD comorbidities, automated sleep monitoring, diagnostic accuracy, telemedicine, sleep-disordered breathing, COPD exacerbations
- MeSH terms
- Automation, Demography, Female, Humans, Male, Mass Screening, Middle Aged, Oximetry, ROC Curve, Sleep Apnea Syndromes, Neural Networks, Computer, Polysomnography, Databases as Topic, Pulmonary Disease, Chronic Obstructive
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.