Control of Multifunctional Prosthetic Hands by Processing the Electromyographic Signal
Open accessThe DOI matches its Crossref record; 63 of the 63 references it cites were found in a registry or an index.
Abstract
The human hand is a complex system, with a large number of degrees of freedom (DoFs), sensors embedded in its structure, actuators and tendons, and a complex hierarchical control. Despite this complexity, the efforts required to the user to carry out the different movements is quite small (albeit after an appropriate and lengthy training). On the contrary, prosthetic hands are just a pale replication of the natural hand, with significantly reduced grasping capabilities and no sensory information delivered back to the user. Several attempts have been carried out to develop multifunctional prosthetic devices controlled by electromyographic (EMG) signals (myoelectric hands), harness (kinematic hands), dimensional changes in residual muscles, and so forth, but none of these methods permits the "natural" control of more than two DoFs. This article presents a review of the traditional methods used to control artificial hands by means of EMG signal, in both the clinical and research contexts, and introduces what could be the future developments in the control strategy of these devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1982) · Trends in Neurosciences · doi:10.1016/0166-2236(82)90076-5 · Cited by 9,089
Vetterli, M., & Kovačević, J. (1995) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 3,205
Entropy-based algorithms for best basis selection
Coifman, R. R., & Wickerhauser, M. V. (1992) · IEEE Transactions on Information Theory · doi:10.1109/18.119732 · Cited by 3,188
Nonlinear principal component analysis using autoassociative neural networks
Kramer, M. A. (1991) · AIChE Journal · doi:10.1002/aic.690370209 · Cited by 3,037
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149
Johansson, R. S., & Vallbo, A. B. (1979) · The Journal of Physiology · doi:10.1113/jphysiol.1979.sp012619 · Cited by 1,291
Netter, F. H. (1974) · Virtual Defense Library (Ministerio de Defensa) · doi:10.5281/zenodo.5507198 · Cited by 1,215
An introduction to neural computing
Kohonen, T. (1988) · Neural Networks · doi:10.1016/0893-6080(88)90020-2 · Cited by 1,202
Kosko, B. (1996) · Cited by 1,042
Robot Hands and the Mechanics of Manipulation
Mason, M. T., Salisbury, J. K., & Parker, J. K. (1989) · Journal of Dynamic Systems, Measurement, and Control · doi:10.1115/1.3153010 · Cited by 911
(1984) · PubMed · Cited by 908
Kapandji, I. A. (1974) · Churchill Livingstone eBooks · Cited by 881
DLR-Hand II: next generation of a dextrous robot hand
Butterfass, J., Grebenstein, M., Liu, H., & Hirzinger, G. (2002) · Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164) · doi:10.1109/robot.2001.932538 · Cited by 808
Neuro-fuzzy rule generation: survey in soft computing framework
Mitra, S., & Hayashi, Y. (2000) · IEEE Transactions on Neural Networks · doi:10.1109/72.846746 · Cited by 726
A wavelet-based continuous classification scheme for multifunction myoelectric control
Englehart, K., Hudgin, B., & Parker, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914793 · Cited by 697
Classification of the myoelectric signal using time-frequency based representations
Englehart, K., Hudgins, B., Parker, P. A., & Stevenson, M. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00066-1 · Cited by 645
The Robonaut hand: a dexterous robot hand for space
Lovchik, C. S., & Diftler, M. A. (2003) · Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C) · doi:10.1109/robot.1999.772420 · Cited by 534
The development of soft gripper for the versatile robot hand
Hirose, S., & Umetani, Y. (1978) · Mechanism and Machine Theory · doi:10.1016/0094-114x(78)90059-9 · Cited by 480
EMG feature evaluation for movement control of upper extremity prostheses
Zardoshti-Kermani, M., Wheeler, B. C., Badie, K., & Hashemi, R. M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.481972 · Cited by 477
Fuzzy EMG classification for prosthesis control
Chan, F. H. Y., Yang, Y.-S., Lam, F. K., Zhang, Y.-T., & Parker, P. A. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867872 · Cited by 376
Time-frequency analysis of myoelectric signals during dynamic contractions: a comparative study
Karlsson, S., Yu, J., & Akay, M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.821766 · Cited by 358
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
Design and development of an underactuated prosthetic hand
Massa, B., Roccella, S., Carrozza, M. C., & Dario, P. (2003) · Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292) · doi:10.1109/robot.2002.1014232 · Cited by 333
Self-citationRobotic Grasping and Fine Manipulation
Cutkosky, M. R. (1985) · The Kluwer International Series in Engineering and Computer Science · doi:10.1007/978-1-4684-6891-5 · Cited by 325
Abe, S., & Lan, M.-S. (1995) · IEEE Transactions on Fuzzy Systems · doi:10.1109/91.366565 · Cited by 313
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
EMG Pattern Analysis and Classification for a Prosthetic Arm
Saridis, G. N., & Gootee, T. P. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324954 · Cited by 236
The application of neural networks to myoelectric signal analysis: a preliminary study
Kelly, M. F., Parker, P. A., & Scott, R. N. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.52324 · Cited by 221
Objective motor response onset detection in surface myoelectric signals
Staude, G., & Wolf, W. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00067-3 · Cited by 217
Onset Detection in Surface Electromyographic Signals: A Systematic Comparison of Methods
Staude, G., Flachenecker, C., Daumer, M., & Wolf, W. (2001) · EURASIP Journal on Advances in Signal Processing · doi:10.1155/s1110865701000191 · Cited by 211
Graupe, D., Salahi, J., & Kohn, K. H. (1982) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(82)90021-8 · Cited by 205
Wavelet applications in medicine
Akay, M. (1997) · IEEE Spectrum · doi:10.1109/6.590747 · Cited by 196
A new ultralight anthropomorphic hand
Schulz, S., Pylatiuk, C., & Bretthauer, G. (2002) · Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164) · doi:10.1109/robot.2001.932988 · Cited by 189
Unsupervised pattern recognition for the classification of EMG signals
Christodoulou, C. I., & Pattichis, C. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.740879 · Cited by 186
Myoelectric Prostheses: state of the art
Scott, R. N., & Parker, P. A. (1988) · Journal of Medical Engineering & Technology · doi:10.3109/03091908809030173 · Cited by 171
MARCUS: a two degree of freedom hand prosthesis with hierarchical grip control
Kyberd, P. J., Holland, O. E., Chappell, P. H., Smith, S., Tregidgo, R., Bagwell, P. J., & Snaith, M. (1995) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.372895 · Cited by 121
A three-state myo-electric control
Dorcas, D. S., & Scott, R. N. (1966) · Medical & Biological Engineering & Computing · doi:10.1007/bf02476154 · Cited by 119
EMG-based human-robot interface for rehabilitation aid
Fukuda, O., Tsuji, T., Ohtsuka, A., & Kaneko, M. (1998) · Proceedings. 1998 IEEE International Conference on Robotics and Automation (Cat. No.98CH36146) · doi:10.1109/robot.1998.680978 · Cited by 106
Time-scale analysis of motor unit action potentials
Pattichis, C. S., & Pattichis, M. S. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.797992 · Cited by 105
Adaptive whitening of the electromyogram to improve amplitude estimation
Clancy, E., & Farry, K. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.844217 · Cited by 99
Riso, R. R. (1999) · Technology and Health Care · doi:10.3233/thc-1999-7604 · Cited by 98
Improving detection of muscle activation intervals
Micera, S., Vannozzi, G., Sabatini, A. M., & Dario, P. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.982274 · Cited by 97
Self-citationSparto, P., Parnianpour, M., Barría, E., & Jagadeesh, J. (2000) · IEEE transactions on rehabilitation engineering · doi:10.1109/86.867887 · Cited by 95
An algorithm for detecting the onset of muscle contraction by EMG signal processing
Micera, S., Sabatini, A. M., & Dario, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00017-4 · Cited by 94
Self-citationMicera, S., Sabatini, A. M., Dario, P., & Rossi, B. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00055-7 · Cited by 90
Self-citationAn Intelligent Anthropomorphic Hand, with Automatic Grasp
Kyberd, P. J., Evans, M., & te Winkel, S. (1998) · Robotica · doi:10.1017/s0263574798000691 · Cited by 84
Cineplasty as a control input for externally powered prosthetic components.
Weir, R. F. F., Heckathorne, C. W., & Childress, D. S. (2001) · PubMed · Cited by 77
Comprehensive Management of the Upper-Limb Amputee
Atkins, D., & Meier, R. (1989) · Springer: New York · doi:10.1007/978-1-4612-3530-9 · Cited by 77
EMG prosthetic hand controller discriminating ten motions using real-time learning method
Nishikawa, D., Yu, W.-W., Yokoi, H., & Kakazu, Y. (1999) · Proceedings 1999 IEEE/RSJ International Conference on Intelligent Robots and Systems. Human and Environment Friendly Robots with High Intelligence and Emotional Quotients (Cat. No.99CH36289) · doi:10.1109/iros.1999.811706 · Cited by 64
Adaptive filtering of the electromyographic signal for prosthetic control and force estimation
Park, E., & Meek, S. (1995) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.464381 · Cited by 63
Weingarden, H., Zeilig, G., Heruti, R., Shemesh, Y., Ohry, A., Dar, A., Katz, D., Nathan, R., & Smith, A. (1998) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-199807000-00002 · Cited by 62
Electrically powered prostheses for the adult with an upper limb amputation
Heger, H., Millstein, S., & Hunter, G. (1985) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.67b2.3980541 · Cited by 60
Dimensional change in muscle as a control signal for powered upper limb prostheses: a pilot study.
Kenney, L., Лисица, Ю. М., Bowker, P., Heath, G. H., & Howard, D. (1999) · Medical Engineering and Physics · doi:10.1016/s1350-4533(99)00089-2 · Cited by 59
Neural interfaces for regenerated nerve stimulation and recording
Dario, P., Garzella, P., Toro, M., Micera, S., Alavi, M., Meyer, U., Valderrama, E., Sebatiani, L., Ghelarducci, B., Mazzoni, C., et al. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.736149 · Cited by 58
Self-citationEstimation of forearm movement from EMG signal and application to prosthetic hand control
Morita, S., Kondo, T., & Ito, K. (2001) · Proceedings 2001 ICRA. IEEE International Conference on Robotics and Automation (Cat. No.01CH37164) · doi:10.1109/robot.2001.933192 · Cited by 55
Agnew, P. J. (1981) · Prosthetics and orthotics international · doi:10.3109/03093648109145332 · Cited by 48
On automatic identification of upper-limb movements using small-sized training sets of EMG signals
Micera, S., Sabatini, A. M., & Dario, P. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00069-2 · Cited by 40
Self-citationDSP-based controller for a multi-degree prosthetic hand
Huang, H.-P., & Chiang, C.-Y. (2000) · Proceedings 2000 ICRA. Millennium Conference. IEEE International Conference on Robotics and Automation. Symposia Proceedings (Cat. No.00CH37065) · doi:10.1109/robot.2000.844790 · Cited by 34
Clinical evaluation of a new, above-elbow, body-powered prosthetic arm: a final report.
Cupo, M. E., & Sheredos, S. J. (1998) · PubMed · Cited by 30
Myoelectric signal analysis using neural networks
Kelly, M. F., Parker, P., & Scott, R. N. (1990) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.62909 · Cited by 25
The development of a novel biomechatronic hand-ongoing research and preliminary results
Carrozza, M. C., Micera, S., Massa, B., Zecca, M., Lazzarini, R., Canelli, N., & Dario, P. (2002) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2001.936462 · Cited by 25
Self-citationA two DoF finger for a biomechatronic artificial hand
Carrozza, M. C., Massa, B., Dario, P., Zecca, M., Micera, S., & Pastacaldi, P. (2002) · Technology and Health Care · doi:10.3233/thc-2002-10201 · Cited by 23
Self-citationCritical Factors in Electrically Powered Upper-Extremity Prosthetics
Miguelez, J. M. (2002) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/00008526-200203000-00010 · Cited by 23
Cited by
Brain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
Feature reduction and selection for EMG signal classification
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.01.102 · Cited by 1,542
Myoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Self-citationScheme, E., & Englehart, K. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0177 · Cited by 969
Metadata
- Authors
- Zecca, M., Micera, S., Carrozza, M. C., & Dario, P.
- Venue
- Critical Reviews in Biomedical Engineering
- Publisher
- Begell House
- Published
- 2017
- Volume
- 45
- Issue
- 1-6
- Pages
- 383-410
- ISSN
- 0278-940X (ISSN-L)
- OpenAlex
- W2020394368
- Cited by
- 570
- References
- 63
- FWCI
- 15.25
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.