Cited by 2,605IoT Networks and ProtocolsIoT and Edge/Fog ComputingService-Oriented Architecture and Web Services

The Constrained Application Protocol (CoAP)

Shelby, Z., Hartke, K., Bormann, C.·2014

Abstract

The Constrained Application Protocol (CoAP) is a specialized web transfer protocol for use with constrained nodes and constrained (e.g., low-power, lossy) networks. The nodes often have 8-bit microcontrollers with small amounts of ROM and RAM, while constrained networks such as IPv6 over Low-Power Wireless Personal Area Networks (6LoWPANs) often have high packet error rates and a typical throughput of 10s of kbit/s. The protocol is designed for machine- to-machine (M2M) applications such as smart energy and building automation. CoAP provides a request/response interaction model between application endpoints, supports built-in discovery of services and resources, and includes key concepts of the Web such as URIs and Internet media types. CoAP is designed to easily interface with HTTP for integration with the Web while meeting specialized requirements such as multicast support, very low overhead, and simplicity for constrained environments.

Integrity signals

Registry

Crossref · 10.17487/rfc7252

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • SCADA systems are geographically distributed, and hence their physical security is a significant issue.

    “SCADA systems are geographically distributed.Hence their physical security is a big issue [32,33].”

    From Architecture and security of SCADA systems: A review (2021) · cites this paper as [32]

  • SCADA systems are expected to run without interruption, so any patch or upgrade cannot be applied without compromising productivity.

    “These systems are expected to run without any interruption, so any patch or upgrade cannot be applied without compromising its productivity [32,33].”

    From Architecture and security of SCADA systems: A review (2021) · cites this paper as [32]

Cited by

Sorted by citations

Authors
Shelby, Z., Hartke, K., & Bormann, C.
Publisher
RFC Editor
Published
2014-06
OpenAlex
W2234639732
Cited by
2,605
References
0
Citations by year
2026: 68 · 2025: 100 · 2024: 105 · 2023: 115 · 2022: 145 · 2021: 177 · 2020: 230 · 2019: 264 · 2018: 331 · 2017: 270 · 2016: 240 · 2015: 202 · 2014: 124 · 2013: 117 · 2012: 81
Type
report
Language
en
Open access
closed
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › IoT Networks and Protocols
  • Physical Sciences › Computer Science › Computer Networks and Communications › IoT and Edge/Fog Computing
  • Physical Sciences › Computer Science › Information Systems › Service-Oriented Architecture and Web Services
Keywords
CoAP, constrained networks, low-power wireless networks, 6LoWPAN, machine-to-machine communication, resource discovery, multicast, Uri, smart energy, building automation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review