Validity of heart rate measurements in wrist-based monitors across skin tones during exercise
Open accessAbstract
Purpose: To evaluate the accuracy of a wrist-based heart rate (HR) monitor at different exercise intensities across different skin tones. Methods: Using a cross-sectional design, we compared HR measures from the wrist-based photoplethysmography Fitbit Charge 5 to the Polar H10 chest strap at rest and during the YMCA Protocol using a recumbent cycle ergometer. Participant were grouped into three skin tone categories: light (Fitzpatrick Scale Skin Types 1+2), medium (Types 3+4), and darker skin tone (Types 5+6). HR measures using the Polar chest strap during the exercise test were categorized as <40%, 40–60%, or >60% HR reserve (HRR). Absolute error in beats per minute (bpm) between the two devices was calculated for each measure. A linear mixed effects model was used to assess interaction effects between skin tone and exercise intensity, with participants as the random effect. Bland-Altman plots were used for visual analyses. Results: Twenty-five participants [mean (SD): 25.8 (1.9) years old; 64% female] were included with 495 observations of simultaneous Fitbit and Polar HR recordings collected during exercise. During exercise, we observed a statistically significant interaction effect between skin tone and exercise intensity. Compared with light skin tone at <40% HRR, mean error was greater for medium skin tone at >60% HRR [mean error (95%CI): 11.8 (5.6–17.9) bpm, p<0.001] and darker skin tone at 40–60% HRR [7.6 (1.7–13.5) bpm, p = 0.011] and >60% HRR [11.7 (5.3–18.0) bpm, p<0.001]. Conclusion: HR measurement error using a wrist-based device was greater with increasing exercise intensity for people with darker skin tones.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Studies using recumbent cycling have demonstrated that errors in HR measurement persist and increase with rising intensity, even with reduced limb movement.
“Studies using recumbent cycling have demonstrated that errors in HR measurement not only persist but actually increase with rising intensity, even with reduced limb movement [28].”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [28]
The Study procedures and Discussion sections say the researchers used a recumbent bike to reduce arm movement and still observed HR measurement errors as exercise intensity increased. However, the Discussion specifies that the increase occurred predominantly in participants with darker skin tones, not lighter skin tones; the citing sentence omits that qualification. Page numbers are not provided in our copy. (LLM, conf=0.88)
Experimental — accuracy not yet measuredThis pattern is consistent with optical absorption by melanin in the green band and reduced pulsatile content reaching the photodiode.
“consistent with optical absorption by melanin in the green band and reduced pulsatile content reaching the photodiode [10,11,28].”
From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [28]
The Introduction (page unavailable) says melanin absorbs green light and reduces reflection, potentially affecting PPG signal accuracy. The Discussion (page unavailable) suggests this may impair detection of pulsatile signal changes, but does not establish that reduced pulsatile content reaches the photodiode; it says the mechanism requires further research. (LLM, conf=0.84)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Fitting Linear Mixed-Effects Models Using <b>lme4</b>
Bates, D., Mächler, M., Bolker, B., & Walker, S. (2015) · Journal of Statistical Software · doi:10.18637/jss.v067.i01 · Cited by 86,835 · see citing works
(2014) · Medical Entomology and Zoology · Cited by 9,400 · see citing works
Health benefits of physical activity: the evidence
Warburton, D. E. R. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.051351 · Cited by 8,007 · see citing works
The validity and practicality of sun-reactive skin types I through VI
Fitzpatrick, T. B. (1988) · Archives of Dermatology · doi:10.1001/archderm.1988.01670060015008 · Cited by 4,339 · see citing works
Fletcher, G. F., Ades, P. A., Kligfield, P., Arena, R., Balady, G. J., Bittner, V. A., Coke, L. A., Fleg, J. L., Forman, D. E., Gerber, T. C., et al. (2013) · Circulation · doi:10.1161/cir.0b013e31829b5b44 · Cited by 2,235 · cited 3× · see citing works
“The American Heart Association recommends monitoring HR response during exercise, and staying approximately 10 bpm below the onset of ischemic symptoms (example, angina) for cardiac patients with an ischemic response [31].”
InfluentialA brief introduction to mixed effects modelling and multi-model inference in ecology
Harrison, X. A., Donaldson, L., Correa-Cano, M. E., Evans, J., Fisher, D. N., Goodwin, C. E. D., Robinson, B. S., Hodgson, D. J., & Inger, R. (2018) · PeerJ · doi:10.7717/peerj.4794 · Cited by 2,094 · see citing works
Billinger, S. A., Arena, R., Bernhardt, J., Eng, J. J., Franklin, B. A., Johnson, C. M., MacKay-Lyons, M., Macko, R. F., Mead, G. E., Roth, E. J., et al. (2014) · Stroke · doi:10.1161/str.0000000000000022 · Cited by 1,529 · see citing works
Self-citationRobustness of linear mixed-effects models to violations of distributional assumptions
Schielzeth, H., Dingemanse, N. J., Nakagawa, S., Westneat, D. F., Allegue, H., Teplitsky, C., Réale, D., Dochtermann, N. A., Garamszegi, L. Z., & Araya‐Ajoy, Y. G. (2020) · Methods in Ecology and Evolution · doi:10.1111/2041-210x.13434 · Cited by 1,393 · see citing works
Evidence for prescribing exercise as therapy in chronic disease
Pedersen, B. K., & Saltin, B. (2006) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1111/j.1600-0838.2006.00520.x · Cited by 1,384 · see citing works
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945 · see citing works
Wearable photoplethysmographic sensors—past and present
Tamura, T., Maeda, Y., Sekine, M., & Yoshida, M. (2014) · Electronics · doi:10.3390/electronics3020282 · Cited by 912 · see citing works
Vascular Adaptation to Exercise in Humans: Role of Hemodynamic Stimuli
Green, D. J., Hopman, M. T. E., Padilla, J., Laughlin, M. H., & Thijssen, D. H. J. (2017) · Physiological Reviews · doi:10.1152/physrev.00014.2016 · Cited by 821 · see citing works
Zhang, Z., Pi, Z., & Liu, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2359372 · Cited by 759 · see citing works
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715 · see citing works
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673 · see citing works
Longitudinal Modeling of the Relationship between Age and Maximal Heart Rate
GELLISH, R. L., GOSLIN, B. R., OLSON, R. E., McDONALD, A., RUSSI, G. D., & MOUDGIL, V. K. (2007) · Medicine & Science in Sports & Exercise · doi:10.1097/mss.0b013e31803349c6 · Cited by 660 · cited 1× · see citing works
“Maximum HR was estimated [HRmax = 206.9 - (0.67 x age)] [41], and used with resting HR to calculate HR reserve (HRR, Maximum HR minus resting HR [42].”
InfluentialShcherbina, A., Mattsson, C., Waggott, D., Salisbury, H., Christle, J., Hastie, T., Wheeler, M., & Ashley, E. (2017) · Journal of Personalized Medicine · doi:10.3390/jpm7020003 · Cited by 625 · see citing works
Mezzani, A., Hamm, L. F., Jones, A. M., McBride, P. E., Moholdt, T., Stone, J. A., Urhausen, A., & Williams, M. A. (2013) · European Journal of Preventive Cardiology · doi:10.1177/2047487312460484 · Cited by 550 · see citing works
Javed, Z., Maqsood, M. H., Yahya, T., Amin, Z., Acquah, I., Valero-Elizondo, J., Andrieni, J. D., Dubey, P., Jackson, R., Daffin, M. A., et al. (2022) · Circulation. Cardiovascular Quality and Outcomes · doi:10.1161/circoutcomes.121.007917 · Cited by 460 · see citing works
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424 · see citing works
<b>GLIMMPSE</b> : Online Power Computation for Linear Models with and without a Baseline Covariate
Kreidler, S. M., Muller, K. E., Grunwald, G. K., Ringham, B. M., Coker-Dukowitz, Z., Sakhadeo, U. R., Baron, A. E., & Glueck, D. H. (2013) · Journal of Statistical Software · doi:10.18637/jss.v054.i10 · Cited by 399 · see citing works
Schaffarczyk, M., Rogers, B., Reer, R., & Gronwald, T. (2022) · Sensors · doi:10.3390/s22176536 · Cited by 349 · see citing works
Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Variable Accuracy of Wearable Heart Rate Monitors during Aerobic Exercise
GILLINOV, S., ETIWY, M., WANG, R., BLACKBURN, G., PHELAN, D., GILLINOV, A. M., HOUGHTALING, P., JAVADIKASGARI, H., & DESAI, M. Y. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001284 · Cited by 345 · see citing works
Accuracy of Heart Rate Watches: Implications for Weight Management
Wallen, M. P., Gomersall, S. R., Keating, S. E., Wisløff, U., & Coombes, J. S. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154420 · Cited by 336 · see citing works
The Surgeon General’s call to action to prevent skin cancer
Watson, M., Garnett, E., Guy, G. P., & Holman, D. M. (2014) · Cited by 318 · see citing works
Accurate Heart Rate Monitoring During Physical Exercises Using PPG
Temko, A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2676243 · Cited by 295 · see citing works
Heart Rate Estimation From Wrist-Worn Photoplethysmography: A Review
Biswas, D., Simões‐Capela, N., Hoof, C. A. V., & Helleputte, N. V. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2914166 · Cited by 263 · see citing works
Robustness of the linear mixed model to misspecified error distribution
Jacqmin‐Gadda, H., Sibillot, S., Proust‐Lima, C., Molina, J., & Thiébaut, R. (2006) · Computational Statistics & Data Analysis · doi:10.1016/j.csda.2006.05.021 · Cited by 230 · see citing works
Heart rate monitors: State of the art
Laukkanen, R. M. T., & Virtanen, P. K. (1998) · Journal of Sports Sciences · doi:10.1080/026404198366920 · Cited by 219 · see citing works
Evidence on the effects of exercise therapy in the treatment of chronic disease
Kujala, U. M. (2009) · British Journal of Sports Medicine · doi:10.1136/bjsm.2009.059808 · Cited by 172 · see citing works
Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking.
(2016) · PubMed Central · Cited by 150 · see citing works
Accuracy of wearable heart rate monitors in cardiac rehabilitation
Etiwy, M., Akhrass, Z., Gillinov, L., Alashi, A., Wang, R., Blackburn, G., Gillinov, S. M., Phelan, D., Gillinov, A. M., Houghtaling, P. L., et al. (2019) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2019.04.08 · Cited by 143 · see citing works
Validation of photoplethysmography as a method to detect heart rate during rest and exercise
Spierer, D. K., Rosen, Z., Litman, L. L., & Fujii, K. (2015) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2015.1047536 · Cited by 139 · see citing works
The relationship between the photoplethysmographic waveform and systemic vascular resistance
Alian, A. A., Haddadin, A. S., Tantawy, H., Badr, T., Stout, R. G., Silverman, D. G., & Shelley, K. H. (2007) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-007-9097-5 · Cited by 136 · see citing works
Accuracy of commercially available heart rate monitors in athletes: a prospective study
Pasadyn, S. R., Soudan, M., Gillinov, M., Houghtaling, P., Phelan, D., Gillinov, N., Bittel, B., & Desai, M. Y. (2019) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2019.06.05 · Cited by 135 · see citing works
Reference values for time- and frequency-domain heart rate variability measures
Sammito, S., & Böckelmann, I. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2016.02.006 · Cited by 131 · see citing works
Cross-Validation of the YMCA Submaximal Cycle Ergometer Test to Predict VO2max
Beekley, M. D., Brechue, W. F., deHoyos, D., Garzarella, L., Werber-Zion, G., & Pollock, M. L. (2004) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2004.10609165 · Cited by 118 · see citing works
Mühlen, J. M., Stang, J. S., Skovgaard, E. L., Júdice, P. B., Molina‐García, P., Johnston, W., Sardinha, L. B., Ortega, F. B., Caulfield, B., Bloch, W., et al. (2021) · British Journal of Sports Medicine · doi:10.1136/bjsports-2020-103148 · Cited by 118 · see citing works
Tedesco, S., Sica, M., Ancillao, A., Timmons, S., Barton, J., & O’Flynn, B. (2019) · PLOS ONE · doi:10.1371/journal.pone.0216891 · Cited by 116 · see citing works
Jensen, M. T., Treskes, R. W., Caiani, E. G., Casado-Arroyo, R., Cowie, M. R., Dilaveris, P., Duncker, D., Di Rienzo, M., Frederix, I., De Groot, N., et al. (2021) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztab011 · Cited by 93 · see citing works
Koerber, D., Khan, S., Shamsheri, T., Kirubarajan, A., & Mehta, S. (2023) · Journal of Racial and Ethnic Health Disparities · doi:10.1007/s40615-022-01446-9 · Cited by 91 · see citing works
Comparison of Polar M600 Optical Heart Rate and ECG Heart Rate during Exercise
HORTON, J. F., STERGIOU, P., FUNG, T. S., & KATZ, L. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001388 · Cited by 79 · see citing works
Scardulla, F., D’Acquisto, L., Colombarini, R., Hu, S., Pasta, S., & Bellavia, D. (2020) · Sensors · doi:10.3390/s20185052 · Cited by 72 · see citing works
Sañudo, B., De Hoyo, M., Muñoz-López, A., Perry, J., & Abt, G. (2019) · Journal of Medical Systems · doi:10.1007/s10916-019-1325-2 · Cited by 48 · see citing works
Parák, J., Salonen, M., Myllymäki, T., & Korhonen, I. (2021) · Sensors · doi:10.3390/s21248411 · Cited by 32 · see citing works
Systematic Review of Fitbit Charge 2 Validation Studies for Exercise Tracking
Irwin, C., & GARY, R. A. (2022) · Translational Journal of the American College of Sports Medicine · doi:10.1249/tjx.0000000000000215 · Cited by 32 · see citing works
Continuous heart rhythm monitoring using mobile photoplethysmography in ambulatory patients
Hochstadt, A., Havakuk, O., Chorin, E., Schwartz, A. L., Merdler, I., Laufer, M., Lubman, N., Ghantous, E., Viskin, S., & Rosso, R. (2020) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2020.04.017 · Cited by 18 · see citing works
Accuracy of a Smartwatch to Assess Heart Rate Monitoring and Atrial Fibrillation in Stroke Patients
Meza, C., Juega, J., Pascual, J. F., Santos‐Ortega, A., Duran, L., Rodriguez, M., Álvarez‐Sabín, J., Seró, L., Ustrell, X., Bashir, S., et al. (2023) · Sensors · doi:10.3390/s23104632 · Cited by 17 · see citing works
Vermunicht, P., Makayed, K., Meysman, P., Laukens, K., Knaepen, L., Vervoort, Y., de Bliek, E., Hens, W., Craenenbroeck, E. M. V., Desteghe, L., et al. (2023) · EP Europace · doi:10.1093/europace/euad122.550 · Cited by 14 · see citing works
Călin, M. A., Manea, D., Savastru, R., & Parasca, S. V. (2022) · Photochemistry and Photobiology · doi:10.1111/php.13725 · Cited by 10 · see citing works
Ruiz‐Malagón, E. J., Ruiz‐Alias, S. A., García‐Pinillos, F., Delgado‐García, G., & Soto-Hermoso, V. M. (2020) · Proceedings of the Institution of Mechanical Engineers Part P Journal of Sports Engineering and Technology · doi:10.1177/1754337120976659 · Cited by 9 · see citing works
"Movement, sweating, and contact pressure as sources of heart rate inaccuracy in wearable devices"
Orini, M., Guvensen, G., Jamieson, A., Chaturvedi, N., & Hughes, A. D. (2022) · Computing in cardiology · doi:10.22489/cinc.2022.237 · Cited by 4 · see citing works
Net Heart Rate for Estimating Oxygen Consumption in Active Adults
Bragada, J. A. A., Magalhães, P. M., São-Pedro, E., Bartolomeu, R. F., & Morais, J. E. (2024) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk9020066 · Cited by 2 · see citing works
Flagged first, then by citations
Research works printed but not linked: 1
- [34]Fitbit Charge 5 User Manual. San Francisco, California: Fitbit LLC; pp. 1– 76.
Cited by
Sorted by citations
Mulholland, A. M., MacDonald, H. V., Aguiar, E. J., & Wingo, J. E. (2025) · European Journal of Applied Physiology · doi:10.1007/s00421-025-05977-x · Cited by 10 · see citing works
Photoplethysmography in Diverse Skin Tones: Evaluating Bias in Smartwatch Health Monitoring
Asif, S., AlSaafeen, A., Nadar, S., Nambiar, S., Dannawi, J., Korrapati, H., & Wilkhoo, H. S. (2025) · Cureus · doi:10.7759/cureus.94074 · Cited by 9 · see citing works
Gielen, J., Oost, N. C. V., Debard, G., Sels, R., Witte, N. A. J. D., Colman, T., Bonroy, B., & Aerts, J. (2026) · JMIR Formative Research · doi:10.2196/85186 · Cited by 8 · see citing works
Why We Should Care About Inclusivity in SportsHCI
Harrison, D. (2025) · Annual Conference on Human-Computer Interaction and Sports (SportsHCI) · doi:10.1145/3749385.3749388 · Cited by 3 · see citing works
The Effect of Tattoos on Heart Rate Validity in the Polar Verity Sense Commercial Wearable Device
Navalta, J. W., Perez, O. R., Mejia, R., & Bunn, J. A. (2025) · Sensors · doi:10.3390/s25226896 · Cited by 3 · see citing works
Li, W., Feng, J., Feng, G., & Feng, S. (2026) · Microchimica Acta · doi:10.1007/s00604-025-07792-9 · Cited by 4 · see citing works
Bartolomeu, R. F., Silva, V., Pereira, A., Morais, G., Sokołowski, K., Strzała, M., Morais, J. E., & Teixeira, J. E. (2025) · Applied Sciences · doi:10.3390/app15115848 · Cited by 3 · see citing works
Kostrna, J., Oparina, E., Palacios, C., Rodriguez, A. J., Pei, J., Ajmal, A., & Ramella-Roman, J. C. (2026) · Sensors · doi:10.3390/s26102922 · Cited by 2 · see citing works
Mai, A., Luan, Y., Loy, S. L., Qin, C., Ji, H., Obeng, A., Oladuti, M., Ejima, K., Mok, K. T., Kaur, S., et al. (2026) · Frontiers in Digital Health · doi:10.3389/fdgth.2026.1805704 · Cited by 3 · see citing works
Zhao, Q., Jiang, W., Zhang, C., Ouyang, M., Wu, N., & Guo, Y. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2026.1863050 · Cited by 2 · see citing works
O’Keeffe, B. T., Britton, Ú., & Ng, K. (2025) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-025-01467-x · Cited by 1 · see citing works
Stress Mindset Matters: Rethinking Mental Stress Detection with Multimodal Wearable Sensors
Meegahapola, L., Constantinides, M., Radivojević, Z., Li, H., Eggleston, M. S., & Quercia, D. (2026) · CHI Conference on Human Factors in Computing Systems · doi:10.1145/3772318.3791340 · Cited by 2 · see citing works
Kusuma, D. A., Nurhasan, N., Putra, N. S. R. P., Németh, Z., Rusdiawan, A., & Arifianto, D. (2026) · Pedagogy of Physical Culture and Sports · doi:10.15561/26649837.2026.0301 · Cited by 1 · see citing works
Lepley, A. S., Davis, F., Melvin, A. C., & Zhao, Z.-Y. (2026) · Sensors · doi:10.3390/s26144486 · Cited by 1 · see citing works
Schipper, R. M., Djibrillah, F. O., Roosink, M., Winkens, L. H. H., John, A., Hazebroek, E. J., Witteveen, A., & Berendsen, A. A. M. (2025) · doi:10.2196/preprints.87324 · Cited by 1 · see citing works
Schipper, R. M., Djibrillah, F. O., Roosink, M., Winkens, L. H. H., John, A., Hazebroek, E. J., Witteveen, A., & Berendsen, A. A. M. (2026) · JMIR mhealth and uhealth · doi:10.2196/87324 · Cited by 1 · see citing works
Klier, K., Masur, L., & Düking, P. (2026) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2026.1872518
Hogue, T., Khoury, A., Njeim, P., Aswad, N., Youssef, L., Birtulescu, S., Faust, A., & Hajj‐Boutros, G. (2026) · Frontiers in Digital Health · doi:10.3389/fdgth.2026.1820224
Miller, D. J., Lastella, M., & Miles, A.-R. (2026) · Sports Medicine - Open · doi:10.1186/s40798-026-01100-2
Adıgüzel, B., Ghorbanpour, M., Sarac, B., Yücer, S., & Çiftçi, F. (2026) · Frontiers in Sensors · doi:10.3389/fsens.2026.1884845
Xu, X., Zheng, W., Song, Y., Sun, Z., Ye, Q., Tao, Y., Dai, C., Dong, K., & Liu, Q. (2026) · Sensor Review · doi:10.1108/sr-03-2026-0314
- Authors
- Hung, S. H., Serwa, K., Rosenthal, G., & Eng, J. J.
- Affiliations
- University of British Columbia (CA)
- Corresponding author
- Eng, Janice J.
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2025-02-10
- Volume
- 20
- Issue
- 2
- Pages
- e0318724
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC11809914
- OpenAlex
- W4407317618
- Cited by
- 21
- References
- 52
- Citations by year
- 2026: 14 · 2025: 7
- FWCI
- 5.07
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Canada Research Chairs
- Michael Smith Health Research BC
- Canadian Institutes of Health Research Foundation Grant (143340)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Keywords
- heart rate monitoring, wrist-worn devices, photoplethysmography, skin tone, Fitzpatrick skin type, exercise intensity, measurement error, chest strap, Fitbit, Polar H10
- MeSH terms
- Adult, Cross-Sectional Studies, Exercise Test, Female, Heart Rate, Humans, Male, Skin Pigmentation, Wrist, Exercise, Photoplethysmography, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review