Cited by 21Non-Invasive Vital Sign MonitoringCardiovascular and exercise physiologyPhysical Activity and Health

Validity of heart rate measurements in wrist-based monitors across skin tones during exercise

Open access
Hung, Stanley Hughwa, Serwa, Kelsey, Rosenthal, Gillian, Eng, Janice J.·2025·PLOS ONE

Abstract

Purpose: To evaluate the accuracy of a wrist-based heart rate (HR) monitor at different exercise intensities across different skin tones. Methods: Using a cross-sectional design, we compared HR measures from the wrist-based photoplethysmography Fitbit Charge 5 to the Polar H10 chest strap at rest and during the YMCA Protocol using a recumbent cycle ergometer. Participant were grouped into three skin tone categories: light (Fitzpatrick Scale Skin Types 1+2), medium (Types 3+4), and darker skin tone (Types 5+6). HR measures using the Polar chest strap during the exercise test were categorized as <40%, 40–60%, or >60% HR reserve (HRR). Absolute error in beats per minute (bpm) between the two devices was calculated for each measure. A linear mixed effects model was used to assess interaction effects between skin tone and exercise intensity, with participants as the random effect. Bland-Altman plots were used for visual analyses. Results: Twenty-five participants [mean (SD): 25.8 (1.9) years old; 64% female] were included with 495 observations of simultaneous Fitbit and Polar HR recordings collected during exercise. During exercise, we observed a statistically significant interaction effect between skin tone and exercise intensity. Compared with light skin tone at <40% HRR, mean error was greater for medium skin tone at >60% HRR [mean error (95%CI): 11.8 (5.6–17.9) bpm, p<0.001] and darker skin tone at 40–60% HRR [7.6 (1.7–13.5) bpm, p = 0.011] and >60% HRR [11.7 (5.3–18.0) bpm, p<0.001]. Conclusion: HR measurement error using a wrist-based device was greater with increasing exercise intensity for people with darker skin tones.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0318724

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Studies using recumbent cycling have demonstrated that errors in HR measurement persist and increase with rising intensity, even with reduced limb movement.

    “Studies using recumbent cycling have demonstrated that errors in HR measurement not only persist but actually increase with rising intensity, even with reduced limb movement [28].”

    From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [28]

    The Study procedures and Discussion sections say the researchers used a recumbent bike to reduce arm movement and still observed HR measurement errors as exercise intensity increased. However, the Discussion specifies that the increase occurred predominantly in participants with darker skin tones, not lighter skin tones; the citing sentence omits that qualification. Page numbers are not provided in our copy. (LLM, conf=0.88)

    Experimental — accuracy not yet measured
  • This pattern is consistent with optical absorption by melanin in the green band and reduced pulsatile content reaching the photodiode.

    “consistent with optical absorption by melanin in the green band and reduced pulsatile content reaching the photodiode [10,11,28].”

    From PPG-Based Heart Rate Accuracy in Hispanic Adults with Fitzpatrick III–V Skin Tones: An Evaluation of Body Composition and Skin-Tone Effects (2026) · cites this paper as [28]

    The Introduction (page unavailable) says melanin absorbs green light and reduces reflection, potentially affecting PPG signal accuracy. The Discussion (page unavailable) suggests this may impair detection of pulsatile signal changes, but does not establish that reduced pulsatile content reaches the photodiode; it says the mechanism requires further research. (LLM, conf=0.84)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. [34]Fitbit Charge 5 User Manual. San Francisco, California: Fitbit LLC; pp. 1– 76.

Cited by

Sorted by citations

Authors
Hung, S. H., Serwa, K., Rosenthal, G., & Eng, J. J.
Affiliations
University of British Columbia (CA)
Corresponding author
Eng, Janice J.
Venue
PLOS ONE
Published
2025-02-10
Volume
20
Issue
2
Pages
e0318724
ISSN
1932-6203 (ISSN-L)
OpenAlex
W4407317618
Cited by
21
References
52
Citations by year
2026: 14 · 2025: 7
FWCI
5.07
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
  • Canada Research Chairs
  • Michael Smith Health Research BC
  • Canadian Institutes of Health Research Foundation Grant (143340)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
Keywords
heart rate monitoring, wrist-worn devices, photoplethysmography, skin tone, Fitzpatrick skin type, exercise intensity, measurement error, chest strap, Fitbit, Polar H10
MeSH terms
Adult, Cross-Sectional Studies, Exercise Test, Female, Heart Rate, Humans, Male, Skin Pigmentation, Wrist, Exercise, Photoplethysmography, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review