Functional electrical stimulation for walking in paraplegia.
The DOI matches its Crossref record.
Abstract
In paraplegic subjects who had functional transection of the spinal cord at a level between the fourth and the eleventh thoracic vertebra, independent reciprocal walking was achieved with the use of a portable microprocessor-controlled stimulator that electrically activated the muscles through percutaneous intramuscular wire electrodes. The electrodes were implanted, by means of hypodermic needles, in the flexors, extensors, abductors, and adductors of the hip; the extensors of the knee; and the plantar flexors and dorsiflexors of the ankle. The subjects had strong, selective, and reproducible muscular contractions that increased in strength during the twenty-two to forty-four months (average, thirty-two months) of training with the regimen. A basic pattern of stimulation was adapted for each individual; each step was initiated by the subject using a hand-operated switch. The subjects progressed to the use of a walker for support, and two of them were able to walk using axillary crutches. Three subjects were able to climb stairs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Functional Electrical Stimulation for Neuromuscular Applications
Peckham, P. H., & Knutson, J. S. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140103 · Cited by 784
Electrical properties of implant encapsulation tissue
Grill, W. M., & Thomas Mortimer, J. (1994) · Annals of Biomedical Engineering · doi:10.1007/bf02368219 · Cited by 376
Patient-driven control of FES-supported standing up: a simulation study
Riener, R., & Fuhr, T. (1998) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.681177 · Cited by 327
Selective control of muscle activation with a multipolar nerve cuff electrode
Veraart, C., Grill, W. M., & Mortimer, J. T. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.237694 · Cited by 320
Ragnarsson, K. T. (2008) · Spinal Cord · doi:10.1038/sj.sc.3102091 · Cited by 301
Prochazka, A., Gauthier, M., Wieler, M., & Kenwell, Z. (1997) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(97)90426-3 · Cited by 250
PossessedHand: techniques for controlling human hands using electrical muscles stimuli
Tamaki, E., Miyaki, T., & Rekimoto, J. (2011) · Proceedings of the SIGCHI Conference on Human Factors in Computing Systems · doi:10.1145/1978942.1979018 · Cited by 229
“The electrical stimulation by PossessedHand is similar to Electrical Muscle Stimulation (EMS) [5, 6, 11] and Functional Electrical Stimulation (FES) [22, 9, 11, 17, 7, 26].”
MethodA nerve cuff technique for selective excitation of peripheral nerve trunk regions
Sweeney, J. D., Ksienski, D. A., & Mortimer, J. T. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.55681 · Cited by 196
Hybrid FES-robot cooperative control of ambulatory gait rehabilitation exoskeleton
del-Ama, A. J., Gil-Agudo, Á., Pons, J. L., & Moreno, J. C. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-27 · Cited by 190
“A considerable period of training (typically several weeks or even months) with electrical stimulation is required to apply such neuroprosthetic solution [38,40,61] or hybrid exoskeletons [15,16,21] for gait-related tasks in SCI, mainly due to changes in muscular characteristics after paralysis.”
BackgroundMuscle selection and walking performance of multichannel FES systems for ambulation in paraplegia
Kobetic, R., Triolo, R. J., & Marsolais, E. B. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559346 · Cited by 185
Self-citationReview of hybrid exoskeletons to restore gait following spinal cord injury
del-Ama, A. J., Koutsou, A. D., Moreno, J. C., de-los-Reyes, A., Gil-Agudo, N., & Pons, J. L. (2012) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2011.03.0043 · Cited by 174
“The last two decades have seen the development of several FES systems based on the designs of Kantrowitz and Liberson [31–38], and the recent advances in FES technology offer the possibility of achieving more complex and efficient stimulation.”
BackgroundSynthesis of paraplegic gait with multichannel functional neuromuscular stimulation
Kobetic, R., & Marsolais, E. B. (1994) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.313148 · Cited by 165
Self-citationKobetic, R., Sharma, M., Triolo, R. J., Uhlir, J. P., Bieri, C., Wibowo, M., Polando, G., Marsolais, E. B., Davis, J. A., & Ferguson, K. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808942 · Cited by 155
Self-citationTriolo, R. J., Bieri, C., Uhlir, J., Kobetic, R., Scheiner, A., & Marsolais, E. B. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90133-1 · Cited by 102
Self-citationRecruitment characteristics of nerve fascicles stimulated by a multigroove electrode
Koole, P., Holsheimer, J., Struijk, J. J., & Verloop, A. J. (1997) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.559348 · Cited by 56
Functional Electrical Stimulation For Walking In Paraplegia: 17-Year Follow-Up Of 2 Cases
Agarwal, S., Kobetic, R., Nandurkar, S., & Marsolais, E. B. (2003) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2003.11753666 · Cited by 49
Self-citationUhlir, J. P., Triolo, R. J., Davis, J. A., & Bieri, C. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.827224 · Cited by 44
“827224 lation (FNS) systems have demonstrated the ability to restore motor, bladder and bowel, and respiratory function after paralysis from central nervous system trauma [2], [4]–[6], [10], [11],”
BackgroundCharkhkar, H., Christie, B. P., Pinault, G. J., Tyler, D. J., & Triolo, R. J. (2019) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108414 · Cited by 19
Metadata
- Authors
- Marsolais, E. B., & Kobetic, R.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1987-06
- Volume
- 69
- Issue
- 5
- Pages
- 728-733
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W1955981612
- Cited by
- 259
- References
- 0
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.