Effect of femoral head size on wear of the polyethylene acetabular component.
The DOI matches its Crossref record.
Abstract
A technique was developed to determine the wear of the acetabular component of a total hip replacement by examination of standardized initial and follow-up radiographs. Three hundred and eighty-five hips were followed for at least 9.5 years after replacement. The least amount and rate of linear wear were associated with use of a femoral head that had a diameter of twenty-eight millimeters (p less than 0.001). The greatest amount and mean rate of linear wear occurred with twenty-two-millimeter components, but these differences were not statistically significant. The greatest volumetric wear and mean rate rate of volumetric wear were seen with thirty-two-millimeter components (p less than 0.001). A wider radiolucent line in acetabular Zone 1 was associated with use of the thirty-two-millimeter head. The amounts of resorption of the proximal part of the femoral neck and of lysis of the proximal part of the femur both correlated positively with the extent of linear and volumetric wear; this suggests an association between the amount of debris from wear and these changes in the femoral neck and proximal part of the femur.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Zirconia as a ceramic biomaterial
Piconi, C., & Maccauro, G. (1999) · Biomaterials · doi:10.1016/s0142-9612(98)00010-6 · Cited by 2,806
Biological reactions to wear debris in total joint replacement
Ingham, E., & Fisher, J. (2000) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411001535219 · Cited by 708
The role of macrophages in osteolysis of total joint replacement
Ingham, E., & Fisher, J. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.04.035 · Cited by 667
Aseptic loosening, not only a question of wear: A review of different theories
Sundfeldt, M., V Carlsson, L., B Johansson, C., Thomsen, P., & Gretzer, C. (2006) · Acta Orthopaedica · doi:10.1080/17453670610045902 · Cited by 622
Leunig, M., Casillas, M. M., Hamlet, M., Hersche, O., Nötzli, H., Slongo, T., & Ganz, R. (2000) · Acta Orthopaedica Scandinavica · doi:10.1080/000164700317393367 · Cited by 539
Schulte, K. R., Callaghan, J. J., Kelley, S. S., & Johnston, R. C. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199307000-00002 · Cited by 510
Wear Is a Function of Use, Not Time
Schmalzried, T. P., Shepherd, E. F., Dorey, F. J., Jackson, W. O., dela Rosa, M., Fa???vae, F., McKellop, H. A., McClung, C. D., Martell, J., Moreland, J. R., et al. (2000) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200012000-00005 · Cited by 474
The influence of weight-bearing on the measurement of polyethylene wear in THA
Smith, P. N., Ling, R. S. M., & Taylor, R. (1999) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.81b2.9154 · Cited by 464
Quantitative Assessment of Walking Activity after Total Hip or Knee Replacement*
SCHMALZRIED, T. P., SZUSZCZEWICZ, E. S., NORTHFIELD, M. R., AKIZUKI, K. H., FRANKEL, R. E., BELCHER, G., & AMSTUTZ, H. C. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199801000-00010 · Cited by 434
Current Concepts Review - Wear in Total Hip and Knee Replacements*
SCHMALZRIED, T. P., & CALLAGHAN, J. J. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199901000-00016 · Cited by 395
Alumina-on-Alumina Total Hip Arthroplasty: A Minimum 18.5-Year Follow-up Study
Hamadouche, M., Boutin, P., Daussange, J., Bolander, M. E., & Sedel, L. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200201000-00011 · Cited by 368
The pathology of total joint arthroplasty
Bauer, T. W., & Schils, J. (1999) · Skeletal Radiology · doi:10.1007/s002560050552 · Cited by 367
100 Most Cited Articles in Orthopaedic Surgery
Lefaivre, K. A., Shadgan, B., & O’Brien, P. J. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1604-1 · Cited by 362
Determination of Polyethylene Wear in Total Hip Replacements with Use of Digital Radiographs*
Martell, J. M., & Berdia, S. (1997) · The Journal of Bone and Joint Surgery (American Volume) · doi:10.2106/00004623-199711000-00004 · Cited by 321
Osteolysis and particle disease in hip replacement: A review
Harris, W. H. (1994) · Acta Orthopaedica Scandinavica · doi:10.3109/17453679408993734 · Cited by 319
Relationship of Acetabular Wear to Osteolysis and Loosening in Total Hip Arthroplasty
Sochart, D. H. (1999) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199906000-00018 · Cited by 272
A unified theory of wear for ultra-high molecular weight polyethylene in multi-directional sliding
Wang, A. (2001) · Wear · doi:10.1016/s0043-1648(00)00522-6 · Cited by 245
The 100 classic papers of orthopaedic surgery: A BIBLIOMETRIC ANALYSIS
Kelly, J. C., Glynn, R. W., O’Briain, D. E., Felle, P., & McCabe, J. P. (2010) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.92b10.24867 · Cited by 232
Average patient walking activity approaches 2 million cycles per year
Silva, M., Shepherd, E. F., Jackson, W. O., Dorey, F. J., & Schmalzried, T. P. (2002) · The Journal of Arthroplasty · doi:10.1054/arth.2002.32699 · Cited by 220
“The average wear rate from 9 radiographic studies with 28-mm metallic femoral heads against cups with conventional polyethylene is 58 mm/y [14–22].”
BackgroundCurrent Concepts in Orthopaedic Biomaterials and Implant Fixation
FRIEDMAN, R. J., BLACK, J., GALANTE, J. O., JACOBS, J. J., & SKINNER, H. B. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199307000-00017 · Cited by 210
CALLAGHAN, J. J., FOREST, E. E., OLEJNICZAK, J. P., GOETZ, D. D., & JOHNSTON, R. C. (1998) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199805000-00011 · Cited by 199
Endo, M., Tipper, J. L., Barton, D. C., Stone, M. H., Ingham, E., & Fisher, J. (2002) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/0954411021536333 · Cited by 190
D???Antonio, J., Capello, W., Manley, M., Naughton, M., & Sutton, K. (2005) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000162995.50971.39 · Cited by 168
Metadata
- Authors
- Livermore, J., Ilstrup, D., & Morrey, B.
- Venue
- The Journal of Bone & Joint Surgery
- Published
- 1990-04
- Volume
- 72
- Issue
- 4
- Pages
- 518-528
- ISSN
- 0021-9355 (ISSN-L)
- OpenAlex
- W2107033736
- Cited by
- 1,024
- References
- 0
- FWCI
- 9.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.