The DOI matches its Crossref record.
Compilation of the Dielectric Properties of Body Tissues at RF and Microwave Frequencies.
Abstract
Knowledge of the dielectric properties of biological materials is of importance in solving electromagnetic interaction problems. There is, as yet, no consensus on such data among scientists dealing with these issues. This project is geared towards producing a database of dielectric data based on measurements using recently developed techniques. This has been achieved through measurement over a wide frequency range. The new data were evaluated by comparison with corresponding data from the literature where available. To facilitate the incorporation of the dielectric data in numerical solutions, their frequency dependence was modelled to a spectrum characterised by 4 dispersion regions. The conductivity of tissues below 100 Hz was estimated from the recent measurements mitigated by data from the literature and used to estimate the body and of various body parts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images
Vaughan, J. T., Garwood, M., Collins, C. M., Liu, W., DelaBarre, L., Adriany, G., Andersen, P., Merkle, H., Goebel, R., Smith, M. B., et al. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1156 · Cited by 890
Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774
Implanted Antennas Inside a Human Body: Simulations, Designs, and Characterizations
Kim, J., & Rahmat-Samii, Y. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.832018 · Cited by 757
Electrical conductivity of tissue at frequencies below 1 MHz
Gabriel, C., Peyman, A., & Grant, E. H. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/16/002 · Cited by 716
Self-citationTranscranial direct current stimulation: A computer-based human model study
Wagner, T., Fregni, F., Fecteau, S., Grodzinsky, A., Zahn, M., & Pascual-Leone, A. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.01.027 · Cited by 567
Huang, Y., Liu, A. A., Lafon, B., Friedman, D., Dayan, M., Wang, X., Bikson, M., Doyle, W. K., Devinsky, O., & Parra, L. C. (2017) · eLife · doi:10.7554/elife.18834 · Cited by 556
Staderini, E. M. (2002) · IEEE Aerospace and Electronic Systems Magazine · doi:10.1109/62.978359 · Cited by 496
Huang, Y., Datta, A., Bikson, M., & Parra, L. C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab208d · Cited by 362
Arena, C. B., Sano, M. B., Rossmeisl, J. H., Caldwell, J. L., Garcia, P. A., Rylander, M. N., & Davalos, R. V. (2011) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-10-102 · Cited by 361
Reusens, E., Joseph, W., Latre, B., Braem, B., Vermeeren, G., Tanghe, E., Martens, L., Moerman, I., & Blondia, C. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2033054 · Cited by 303
La Gioia, A., Porter, E., Merunka, I., Shahzad, A., Salahuddin, S., Jones, M., & O’Halloran, M. (2018) · Diagnostics · doi:10.3390/diagnostics8020040 · Cited by 297
SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil
Collins, C. M., Li, S., & Smith, M. B. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400610 · Cited by 272
Collins, C. M., & Smith, M. B. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1091 · Cited by 260
Analysis of wave behavior in lossy dielectric samples at high field
Yang, Q. X., Wang, J., Zhang, X., Collins, C. M., Smith, M. B., Liu, H., Zhu, X., Vaughan, J. T., Ugurbil, K., & Chen, W. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10137 · Cited by 255
Withayachumnankul, W., Png, G. M., Yin, X., Atakaramians, S., Jones, I., Lin, H., Ung, B. S. Y., Balakrishnan, J., Ng, B. W.-H., Ferguson, B., et al. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.900325 · Cited by 179
Wireless technologies for implantable devices
Nelson, B. D., Karipott, S. S., Wang, Y., & Ong, K. G. (2020) · Sensors · doi:10.3390/s20164604 · Cited by 125
Zargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115
“cole-cole models provided in [32]–[35].”
Continuous cuffless blood pressure monitoring with a wearable ring bioimpedance device
Sel, K., Osman, D., Huerta, N., Edgar, A., Pettigrew, R. I., & Jafari, R. (2023) · npj Digital Medicine · doi:10.1038/s41746-023-00796-w · Cited by 100
Review on medical implantable antenna technology and imminent research challenges
Soliman, M. M., Chowdhury, M. E. H., Khandakar, A., Islam, M. T., Qiblawey, Y., Musharavati, F., & Zal Nezhad, E. (2021) · Sensors · doi:10.3390/s21093163 · Cited by 95
Metadata
- Authors
- Gabriel, C.
- Publisher
- Defense Technical Information Center
- Published
- 1996-01-01
- OpenAlex
- W1903804808
- Cited by
- 2,097
- References
- 0
- Type
- report
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.