CoChat

Tests of Cycling Performance

Paton, Carl D., Hopkins, Will G. · 2001 · Sports Medicine

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Abstract

Performance tests are an integral component of assessment for competitive cyclists in practical and research settings. Cycle ergometry is the basis of most of these tests. Most cycle ergometers are stationary devices that measure power while a cyclist pedals against sliding friction (e.g. Monark), electromagnetic braking (e.g. Lode), or air resistance (e.g. Kingcycle). Mobile ergometers (e.g. SRM cranks) allow measurement of power through the drive train of the cyclist's own bike in real or simulated competitions on the road, in a velodrome or in the laboratory. The manufacturers' calibration of all ergometers is questionable; dynamic recalibration with a special rig is therefore desirable for comparison of cyclists tested on different ergometers. For monitoring changes in performance of a cyclist, an ergometer should introduce negligible random error (variation) in its measurements; in this respect, SRM cranks appear to be the best ergometer, but more comparison studies of ergometers are needed. Random error in the cyclist's performance should also be minimised by choice of an appropriate type of test. Tests based on physiological measures (e.g. maximum oxygen uptake, anaerobic threshold) and tests requiring self-selection of pace (e.g. constant-duration and constant-distance tests) usually produce random error of at least approximately 2 to 3% in the measure of power output. Random error as low as approximately 1% is possible for measures of power in 'all-out' sprints, incr…

Overview

Integrity signals

Registry

Crossref · 10.2165/00007256-200131070-00004

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 19 references

Research works printed but not linked: 1

  1. Wilmore, 1982, Med Sci Sports Exerc, 14, 322

Cited by

Metadata

Authors
Paton, C. D., & Hopkins, W. G.
Affiliations
  • Waikato Institute of Technology (NZ)
  • University of Otago (NZ)
Corresponding author
Hopkins, Will G.
Venue
Sports Medicine
Published
2001
Volume
31
Issue
7
Pages
489-496
ISSN
0112-1642 (ISSN-L)
OpenAlex
W2046692092
Cited by
178
References
18
Citations by year
2026: 4 · 2025: 6 · 2024: 7 · 2023: 6 · 2022: 7 · 2021: 15 · 2020: 8 · 2019: 6 · 2018: 14 · 2017: 8 · 2016: 10 · 2015: 4 · 2014: 10 · 2013: 3 · 2012: 11
FWCI
2.32
Type
journal article
Language
en
Open access
closed
Locations
  • Sports Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Victoria University Research Repository (Victoria University) (submittedVersion)
Topics
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Social Sciences › Education › Sports Science and Education
Keywords
cycle ergometry, power output measurement, random error, incremental test, all-out sprints, time trial, VO2max, anaerobic threshold, competitive cyclists, performance monitoring
MeSH terms
Bicycling, Calibration, Humans, Task Performance and Analysis, Ergometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.