Cardiac Monitoring in Patients with Syncope: Making that Elusive Diagnosis
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Elucidating the cause of syncope is often a diagnostic challenge. At present, there is a myriad of ambulatory cardiac monitoring modalities available for recording cardiac rhythm during spontaneous symptoms. We provide a comprehensive review of these devices and discuss strategies on how to reach the elusive diagnosis based on current evidencebased recommendations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Self-citationIncidence and Prognosis of Syncope
Soteriades, E. S., Evans, J. C., Larson, M. G., Chen, M. H., Chen, L., Benjamin, E. J., & Levy, D. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012407 · Cited by 1,364 · cited 2×
“Syncope is defined as a transient loss of consciousness secondary to transient global reduction in cerebral blood flow characterized by rapid onset, short duration and spontaneous complete recovery [1].”
Diagnostic value of history in patients with syncope with or without heart disease
Alboni, P., Brignole, M., Menozzi, C., Raviele, A., Del Rosso, A., Dinelli, M., Solano, A., & Bottoni, N. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(01)01241-4 · Cited by 444
Misdiagnosis of epilepsy: many seizure-like attacks have a cardiovascular cause
Zaidi, A., Clough, P., Cooper, P., Scheepers, B., & Fitzpatrick, A. P. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)00700-2 · Cited by 422
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
Self-citationHistorical criteria that distinguish syncope from seizures
Sheldon, R., Rose, S., Ritchie, D., Connolly, S. J., Koshman, M.-L., Lee, M. A., Frenneaux, M., Fisher, M., & Murphy, W. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01940-x · Cited by 398
Mechanism of Syncope in Patients With Isolated Syncope and in Patients With Tilt-Positive Syncope
Moya, A., Brignole, M., Menozzi, C., Garcia-Civera, R., Tognarini, S., Mont, L., Botto, G., Giada, F., Cornacchia, D., & on behalf of the International Study on Syncope of Uncertain Etiology (ISSUE) Investigators (2001) · Circulation · doi:10.1161/hc3601.095708 · Cited by 378
Brignole, M., Sutton, R., Menozzi, C., Garcia-Civera, R., Moya, A., Wieling, W., Andresen, D., Benditt, D. G., & Vardas, P. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi842 · Cited by 376
GANZEBOOM, K. S., MAIRUHU, G., REITSMA, J. B., LINZER, M., WIELING, W., & VAN DIJK, N. (2006) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00595.x · Cited by 375 · cited 1×
“Keywords: Syncope, loop recorder, holter monitor, cardiac monitor.”
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
Use of an Extended Monitoring Strategy in Patients With Problematic Syncope
Krahn, A. D., Klein, G. J., Yee, R., Takle-Newhouse, T., & Norris, C. (1999) · Circulation · doi:10.1161/01.cir.99.3.406 · Cited by 360 · cited 1×
“Currently there are several studies establishing the utility of ICM in the diagnosis of syncope [25-30].”
Self-citationDel Rosso, A., Ungar, A., Maggi, R., Giada, F., Petix, N. R., De Santo, T., Menozzi, C., & Brignole, M. (2008) · Heart · doi:10.1136/hrt.2008.143123 · Cited by 344 · cited 1×
“The Holter monitor is a portable battery-operated device that connects to the patient using bipolar electrodes, providing recordings from up to 12 ECG leads.”
MethodMechanism of syncope in patients with bundle branch block and negative electrophysiological test
Brignole, M., Menozzi, C., Moya, A., Garcia-Civera, R., Mont, L., Alvarez, M., Errazquin, F., Beiras, J., Bottoni, N., Donateo, P., et al. (2001) · Circulation · doi:10.1161/hc4201.097837 · Cited by 328 · cited 2×
“Syncope is defined as a transient loss of consciousness secondary to transient global reduction in cerebral blood flow characterized by rapid onset, short duration and spontaneous complete recovery [1].”
CLINICAL GUIDELINE: Diagnosing Syncope: Part 2: Unexplained Syncope
Linzer, M., Yang, E. H., Estes, N. A. M., Wang, P., Vorperian, V. R., & Kapoor, W. N. (1997) · Annals of Internal Medicine · doi:10.7326/0003-4819-127-1-199707010-00014 · Cited by 313
Edvardsson, N., Frykman, V., van Mechelen, R., Mitro, P., Mohii-Oskarsson, A., Pasquie, J.-L., Ramanna, H., Schwertfeger, F., Ventura, R., Voulgaraki, D., et al. (2011) · Europace · doi:10.1093/europace/euq418 · Cited by 250 · cited 1×
“PICTURE (Place of Reveal In the Care pathway and Treatment of patients with Unexplained Recurrent Syncope) is the largest prospective, multicenter, observational study to date to evaluate the usage and diagnostic effectiveness of ICMs in the everyday clinical diagnostic workup of patients with unexplained syncope [36].”
BackgroundIncremental diagnostic yield of loop electrocardiographic recorders in unexplained syncope
Linzer, M., Pritchett, E. L. C., Pontinen, M., McCarthy, E., & Divine, G. W. (1990) · The American Journal of Cardiology · doi:10.1016/0002-9149(90)90591-n · Cited by 239
The clinical impact of implantable loop recorders in patients with syncope
Farwell, D. J., Freemantle, N., & Sulke, N. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi602 · Cited by 219 · cited 1×
“Seventeen-month followup data from the same group of patients were reported in 2006 [40].”
Mechanism of syncope in patients with heart disease and negative electrophysiologic test
Menozzi, C., Brignole, M., Garcia-Civera, R., Moya, A., Botto, G., Tercedor, L., Migliorini, R., & Navarro, X. (2002) · Circulation · doi:10.1161/01.cir.0000018125.31973.87 · Cited by 204
Is syncope a risk factor for poor outcomes? comparison of patients with and without syncope
Kapoor, W. N., & Hanusa, B. H. (1996) · The American Journal of Medicine · doi:10.1016/s0002-9343(95)00052-6 · Cited by 180 · cited 2×
“A standard ECG should be ordered for all patients with syncope [3-9].”
Cost implications of testing strategy in patients with syncope
Krahn, A. D., Klein, G. J., Yee, R., Hoch, J. S., & Skanes, A. C. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00659-4 · Cited by 170
Self-citationSivakumaran, S., Krahn, A. D., Klein, G. J., Finan, J., Yee, R., Renner, S., & Skanes, A. C. (2003) · The American Journal of Medicine · doi:10.1016/s0002-9343(03)00233-x · Cited by 160 · cited 2×
“Twenty-four percent of loop recorder patients failed to activate the device properly, suggesting limited usefulness in some patients [20].”
Self-citationThe Duration of Holter Monitoring in Patients With Syncope: Is 24 Hours Enough?
Bass, E. B. (1990) · Archives of Internal Medicine · doi:10.1001/archinte.1990.00390170103022 · Cited by 156 · cited 2×
“In a study which evaluated extension of Holter monitoring duration to 72 h [13], there was an increase in the number of asymptomatic arrhythmias detected, but not the overall diagnostic yield.”
Krahn, A. D., Klein, G. J., Yee, R., & Norris, C. (1998) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)00237-9 · Cited by 151 · cited 1×
“Currently there are several studies establishing the utility of ICM in the diagnosis of syncope [25-30].”
Self-citationUse of implantable loop recorders in the diagnosis and management of syncope*1
FARWELL, D. (2004) · European Heart Journal · doi:10.1016/j.ehj.2004.03.010 · Cited by 132
Reiffel, J. A., Schwarzberg, R., & Murry, M. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2005.01.025 · Cited by 131
Joshi, A. K., Kowey, P. R., Prystowsky, E. N., Benditt, D. G., Cannom, D. S., Pratt, C. M., McNamara, A., & Sangrigoli, R. M. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.12.015 · Cited by 110
Brown, A. P., Dawkins, K. D., & Davies, J. G. (1987) · Heart · doi:10.1136/hrt.58.3.251 · Cited by 96
BRIGNOLE, M., MENOZZI, C., MAGGI, R., SOLANO, A., DONATEO, P., BOTTONI, N., LOLLI, G., QUARTIERI, F., CROCI, F., & ODDONE, D. (2005) · Europace · doi:10.1016/j.eupc.2005.02.116 · Cited by 76 · cited 2×
“Currently there are several studies establishing the utility of ICM in the diagnosis of syncope [25-30].”
Utility of Implantable Loop Recorder (Reveal Plus®) in the Diagnosis of Unexplained Syncope
LOMBARDI, F., CALOSSO, E., MASCIOLI, G., MARANGONI, E., DONATO, A., ROSSI, S., PALA, M., FOTI, F., & LUNATI, M. (2005) · Europace · doi:10.1016/j.eupc.2004.09.003 · Cited by 76 · cited 1×
“Currently there are several studies establishing the utility of ICM in the diagnosis of syncope [25-30].”
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope
Shen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.004 · Cited by 478
Self-citationShen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000499 · Cited by 438
Self-citationShen, W.-K., Sheldon, R. S., Benditt, D. G., Cohen, M. I., Forman, D. E., Goldberger, Z. D., Grubb, B. P., Hamdan, M. H., Krahn, A. D., Link, M. S., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000498 · Cited by 407
Self-citation
Metadata
- Authors
- Subbiah, R., Chia, P.-L., Gula, L., Klein, G., Skanes, A., Yee, R., & Krahn, A.
- Venue
- Current Cardiology Reviews
- Publisher
- Bentham Science Publishers Ltd.
- Published
- 2014-02
- Volume
- 9
- Issue
- 4
- Pages
- 299-307
- ISSN
- 1573-403X (ISSN-L)
- OpenAlex
- W2122288897
- Cited by
- 19
- References
- 29
- FWCI
- 2.39
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.