Wearable Technology to Quantify the Nutritional Intake of Adults: Validation Study

Open access
Dimitratos, Sarah M, German, J Bruce, Schaefer, Sara E·2020·JMIR mHealth and uHealth

Published version of a preprint

Abstract

Background: Wearable and mobile sensor technologies can be useful tools in precision nutrition research and practice, but few are reliable for obtaining accurate and precise measurements of diet and nutrition. Objective: This study aimed to assess the ability of wearable technology to monitor the nutritional intake of adult participants. This paper describes the development of a reference method to validate the wristband’s estimation of daily nutritional intake of 25 free-living study participants and to evaluate the accuracy (kcal/day) and practical utility of the technology. Methods: Participants were asked to use a nutrition tracking wristband and an accompanying mobile app consistently for two 14-day test periods. A reference method was developed to validate the estimation of daily nutritional intake of participants by the wristband. The research team collaborated with a university dining facility to prepare and serve calibrated study meals and record the energy and macronutrient intake of each participant. A continuous glucose monitoring system was used to measure adherence with dietary reporting protocols, but these findings are not reported. Bland-Altman tests were used to compare the reference and test method outputs (kcal/day). Results: A total of 304 input cases were collected of daily dietary intake of participants (kcal/day) measured by both reference and test methods. The Bland-Altman analysis had a mean bias of −105 kcal/day (SD 660), with 95% limits of agreement between −1400 and 1189. The regression equation of the plot was Y=−0.3401X+1963, which was significant (P<.001), indicating a tendency for the wristband to overestimate for lower calorie intake and underestimate for higher intake. Researchers observed transient signal loss from the sensor technology of the wristband to be a major source of error in computing dietary intake among participants. Conclusions: This study documents high variability in the accuracy and utility of a wristband sensor to track nutritional intake, highlighting the need for reliable, effective measurement tools to facilitate accurate, precision-based technologies for personal dietary guidance and intervention.

AI snapshot

Written from the paper’s full text.

TL;DR

This validation study tested a wristband (GoBe2) against a calibrated dining-facility reference method for estimating daily nutritional intake in free-living adults. It found high variability and wide limits of agreement, with the wristband tending to overestimate lower calorie intake and underestimate higher intake.

Key findings

  • Across 304 daily intake measurements from 24 participants, Bland-Altman analysis showed a mean bias of −105 kcal/day (SD 660), with 95% limits of agreement from −1400 to 1189 kcal/day.
  • The regression equation on the Bland-Altman plot was Y=−0.3401X+1963 (P<.001), indicating systematic overestimation at lower calorie intake and underestimation at higher intake; Pearson correlation between methods was r=−0.496 (95% CI −0.576 to −0.406; P<.001).
  • Transient signal loss from the wristband sensor was reported as a major source of error in computing dietary intake.
  • Age, sex, and BMI classification did not significantly affect bias in multiple regression or ANOVA tests (P=.15, .18, and .12, respectively).

Methods

  • Prospective validation study in free-living adults aged 18–50 years; intended sample N=25, with 304 kcal/day measurements retained from 24 participants during phase 2 after data cleaning.
  • Participants used the GoBe2 wristband and app for two 14-day test periods; all meals were prepared, calibrated, served, and weighed at a UC Davis dining facility, with offsite foods self-reported and packaged foods provided when possible.
  • Daily energy intake was compared between the reference method and wristband using Bland-Altman analysis; continuous glucose monitoring was used to assess adherence to dietary reporting protocols but was not incorporated into the present dataset.

Limitations

  • The paper states that exact nutrient quantities in each portion could not be consistently and routinely ensured in the high-throughput dining facility, and protocol adherence was lower than anticipated: only 56% of scheduled meals were attended (565/1008).
  • The paper reports form-factor limitations including required daily charging, bulky size, and poor skin contact, which caused data loss; CGM devices also became dislodged (13/72, 18%), with 2 of 24 participants (8%) having repeated displacement.
  • The text makes evident additional constraints: the analyzed sample was 24 participants, two participants completed only 10 of 14 days in phase 2, offsite food consumption was discouraged but not prohibited, and CGM adherence data were not included in the validation dataset.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.2196/16405

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Claims the paper makes

7 of 17 cited sources checked · 4 supported · 0 flagged · accuracy not yet measured

  • Premisecitation

    The FSL's mean absolute relative difference compared with measured capillary blood glucose levels was 13.2% (95% CI 12.0% to 14.4%).

    “One study showed that the FSL’s mean absolute relative difference compared with measured capillary blood glucose levels was 13.2% (95% CI 12.0% to 14.4%) [29].”
    Quote in the paperNot a substantial claim1 of 1 sources checked
  • Findingown data

    The Bland-Altman analysis comparing reference and test methods had a mean bias of −105 kcal/day (SD 660).

    “The Bland-Altman analysis had a mean bias of −105 kcal/day (SD 660), with 95% limits of agreement between −1400 and 1189.”
    Quote in the paperSubstantial claim
  • Findingown data

    The 95% limits of agreement between reference and test methods were between −1400 and 1189 kcal/day.

    “The Bland-Altman analysis had a mean bias of −105 kcal/day (SD 660), with 95% limits of agreement between −1400 and 1189.”
    Quote in the paperSubstantial claim
  • Findingnone given

    Transient signal loss from the sensor technology of the wristband was a major source of error in computing dietary intake among participants.

    “Researchers observed transient signal loss from the sensor technology of the wristband to be a major source of error in computing dietary intake among participants.”
    Quote in the paperNot a substantial claim
  • Findingown data

    Of those with rapid glucose increases inconsistent with meal time, 68.3% (41/60) were attributed to reported bouts of exercise or other physical activity.

    “Of those, 68.3% (41/60) were attributed to reported bouts of exercise or other physical activity.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim. 41
  • May combine two claims. 19
  • Classified as probably not a substantial claim. May combine two claims.

    Premisecitation

    Different people respond differently to foods and nutrients, warranting personalized approaches to nutrition interventions and services.

    “It is now understood that different people respond differently to foods and nutrients, warranting personalized approaches to nutrition interventions and services [3,17-21].”
    Quote in the paperSubstantial claim3 of 6 sources checked
    • cites [3] source
    • cites [17] source

      The Conclusions report substantial individual variation in lipidomic responses to omega-3 fatty acids, and the Discussion links that variation to the goal of a more personalized approach. The study concerns one nutrient intervention in 12 healthy subjects; it does not establish differing responses to foods and nutrients generally or address personalized nutrition services. (LLM, conf=0.85)

      Experimental — accuracy not yet measured
    • cites [18] source
    • cites [19] source
    • cites [20] source
    • cites [21] source
  • Classified as probably not a substantial claim.

    Premisecitation

    Wearable and mobile sensor technologies can be useful tools in precision nutrition research and practice.

    “Wearable and mobile sensor technologies can be useful tools in precision nutrition research and practice”
    • Also stated in: § Introduction · plain
      “mobile and wearable body sensors that enable more spatially and temporally specific measures of a broader range of phenotypic factors [4,13-15].”
    Quote in the paperSubstantial claim3 of 4 sources checked
    • cites [4] source
    • cites [13] source
    • cites [14] source

      The Electrochemical Biosensors section describes a wireless mouth-guard biosensor and its potential extension to wearable health and fitness monitoring. The Current Research Trends section also discusses wearable sensors that screen metabolites as indicators of health. Neither passage addresses their use in precision nutrition research or practice, and the paper does not establish the claimed role for mobile sensors. (LLM, conf=0.84)

      Experimental — accuracy not yet measured
    • cites [15] source

      The Introduction describes wearable sensors as potentially useful for health monitoring, including measuring energy consumption. However, it does not discuss their use in precision nutrition research or practice, or establish the usefulness of mobile sensor technologies for that purpose. The Results (Calorie Accuracy for Different Devices) also report poor accuracy for energy-consumption measurements. (LLM, conf=0.82)

      Experimental — accuracy not yet measured
  • Classified as probably not a substantial claim.

    Findingown data

    A total of 304 input cases of daily dietary intake (kcal/day) measured by both reference and test methods were collected.

    “A total of 304 input cases were collected of daily dietary intake of participants (kcal/day) measured by both reference and test methods.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    The regression equation of the Bland-Altman plot was Y=−0.3401X+1963, which was significant (P<.001).

    “The regression equation of the plot was Y=−0.3401X+1963, which was significant (P<.001)”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingown data

    Linear regression analysis on the Bland-Altman plot revealed a regression equation of Y=−0.3401X+1963 that was significant (P<.001).

    “Linear regression analysis on the Bland-Altman plot revealed a regression equation of Y=−0.3401X+1963 that was significant (P<.001).”
    Quote in the paperNot a substantial claim
    • Rests on an assumption: The reference method accurately measures true daily energy intake.
  • May combine two claims.

    Findingown data

    Analysis of variance tests assessing the effects of participants' age, sex, and BMI classification on bias were not significant (P=.15, .18, and .12, respectively).

    “Analysis of variance tests were conducted to assess the effects of the participants’ age, sex, and BMI classification on bias, and the effects were not significant (P=.15, .18, and .12, respectively).”
    Quote in the paperNot a substantial claim
    • Rests on an assumption: The reference method accurately measures true daily energy intake.
  • Classified as probably not a substantial claim. May combine two claims.

    Findingnone given

    The wristband required an hour each day to obtain a full charge, and any loss of charge would disable data collection.

    “In addition, the wristband required an hour each day to obtain a full charge; any loss of charge would disable data collection accordingly.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Findingreasoning

    The unit required an hour of charging each day, which required removal of the device, preventing the detection of calories ingested within several hours before removal.

    “battery life, as the unit required an hour of charging each day, which required removal of the device, preventing the detection of calories ingested within several hours before removal”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Findingreasoning

    A skin adhesive (Skin-Tac) was useful in reinforcing the CGM attachment.

    “In these cases, a skin adhesive (Skin-Tac) was useful in reinforcing the CGM attachment.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Findingown data

    Bland-Altman analysis showed a mean bias of −105 (SD 660) kcal/day, with 95% limits of agreement between −1400 and 1189.

    “As depicted in Figure 2, a Bland-Altman analysis showed a mean bias of −105 (SD 660) kcal/day, with 95% limits of agreement (LoA) between −1400 and 1189.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: The reference method accurately measures true daily energy intake.
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Premisecitation

    Continuous glucose monitors are designed to provide more precise tracking of glucose levels for diabetic patients compared with standard blood sampling methods, to more precisely guide disease management.

    “For example, continuous glucose monitors are designed to provide more precise tracking of glucose levels for diabetic patients compared with standard blood sampling methods, the goal being to more precisely guide disease management [26,27].”
    Quote in the paperNot a substantial claim0 of 2 sources checked
    • cites [26] source
    • cites [27] Dungan, K, 2000, Monitoring Technologies – Continuous Glucose Monitoring, Mobile Technology, Biomarkers of Glycemic Control

      Not checked in the free run.

  • Classified as probably not a substantial claim.

    Premisenone given

    The USDA Food Composition Database cannot account for inherent variability in climate, soil quality, geographic location, item ripeness, and cooking method, which may alter the nutrient composition of food.

    “The United States Department of Agriculture (USDA) Food Composition Database is the gold standard for nutrient analysis; albeit comprehensive in scope, this tool cannot possibly account for inherent variability in climate, soil quality, geographic location, item ripeness, and cooking method, all of which may significantly alter the nutrient composition of food.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationown data

    The wristband tends to overestimate for lower calorie intake and underestimate for higher calorie intake.

    “indicating a tendency for the wristband to overestimate for lower calorie intake and underestimate for higher intake.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductown data

    Between August 2018 and September 2018, 76 adults were screened, and 35 met the inclusion criteria for enrollment in phase 1.

    “Between August 2018 and September 2018, 76 adults were screened, and 35 met the inclusion criteria for enrollment in phase 1 of the study that would take place from September 25 to October 9, 2018.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    CGM data were analyzed to assess the adherence of individual participants to reference dietary intake reporting protocols.

    “CGM data were analyzed to assess the adherence of individual participants to reference dietary intake reporting protocols.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductreasoning

    Participants were blinded to their personal glucose data because the FSL Pro System did not include individual readers with each unit.

    “As the FSL Pro System did not include individual readers with each unit, participants were blinded to their personal glucose data.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    All project staff were trained by the RD in appropriate food handling and safety, food weighing, and meal recording duties.

    “All project staff were trained by the RD in appropriate food handling and safety, food weighing, and meal recording duties.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Study design and conductnone given

    The plate waste from each participant was deconstructed by ingredient and individually weighed at the end of each meal period.

    “The plate waste from each participant was deconstructed by ingredient and individually weighed at the end of each meal period.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationown data

    Despite a relatively small bias, the limits of agreement were wide, making the results of the comparison ambiguous.

    “Despite a relatively small bias, the LoAs were wide, making the results of the comparison ambiguous.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: The reference method accurately measures true daily energy intake.
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Although CGM was used to measure nonadherence to dietary intake reporting protocols, these data were not incorporated in the present dataset.

    “Although CGM was used to measure nonadherence to dietary intake reporting protocols, these data were not incorporated in the present dataset.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Study design and conductreasoning

    Given numerous factors involved with intermittent data loss from the wristband technology, 2 weeks was defined as the minimum period required to gather continuous data from 25 free-living participants for validation purposes.

    “Given that numerous factors were involved with intermittent data loss from the wristband technology, 2 weeks was defined as the minimum period required to gather continuous data from 25 free-living participants for validation purposes.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductown data

    The initial sample included 20 women and 15 men, with an ethnic distribution of 38% white, 41% Asian, and 21% Hispanic, an average age of 25.3 (SD 6.4) years, and a mean BMI of 24.2 (SD 5.1) kg/m2.

    “The initial sample included 20 women and 15 men, with an ethnic distribution of 38% white, 41% Asian, and 21% Hispanic, an average age of 25.3 (SD 6.4) years, and a mean BMI of 24.2 (SD 5.1) kg/m2.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductown data

    Three participants dropped out during the first week of phase 1 because of time constraints that prohibited multiple visits to the campus dining facility each day.

    “Three participants dropped out during the first week of phase 1 because of time constraints that prohibited multiple visits to the campus dining facility each day.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Two research staff were trained and designated to analyze each project menu item for energy and macronutrient content.

    “Overall, 2 research staff were trained and designated to analyze each project menu item for energy (kcal) and macronutrient content.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Several strategies were included in the study design to prevent data loss, such as targeting problematic cases early, checking in with participants, and monitoring sensor position daily.

    “As described previously, several strategies were included in the study design to prevent data loss, such as targeting problematic cases early, checking in with participants, and monitoring sensor position daily.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Blood samples were analyzed according to the manufacturer's instructions and quality controls by UC Davis Health System Medical Diagnostics.

    “Tests were performed according to the manufacturer’s instructions and quality controls by UC Davis Health System Medical Diagnostics.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductown data

    Phase 1 was completed by 32 participants, of which 24 enrolled in phase 2.

    “Phase 1 was completed by 32 participants, of which 24 enrolled in phase 2 (October 30 to November 13, 2018).”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Significant glucose increases (>20 mg/dL per 30 min) occurring outside of specified study mealtimes or not reported in food intake diaries were flagged for further examination.

    “Significant glucose increases (>20 mg/dL per 30 min) occurring outside of specified study mealtimes or not reported in food intake diaries were flagged for further examination.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductown data

    Research staff used a third-party site (Dietitian's Cabinet) to access participants' deidentified data up to the minute to assess the frequency of contact interruptions.

    “Research staff used a third-party site (Dietitian’s Cabinet) to access participants’ deidentified data up to the minute from which the frequency of contact interruptions could be assessed.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Study design and conductreasoning

    Mixed dishes were avoided to reduce error in calculating calories and macronutrients served at each meal.

    “Mixed dishes were avoided to reduce error in calculating calories and macronutrients that were served at each meal.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    During the 14-day test period, CGM units would occasionally become detached.

    “During the 14-day test period, units would occasionally become detached.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductcitation

    Anthropometric measurements were conducted by the principal investigator using methods defined in the anthropometric standardization reference manual.

    “All anthropometric measurements were conducted by the principal investigator (PI) using methods defined in the anthropometric standardization reference manual [28].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [28] Lohan, T, 1988, Anthropometric Standardization Reference Manual

      Not checked in the free run.

  • Classified as probably not a substantial claim.

    Study design and conductreasoning

    Menu items were selected to serve at breakfast, lunch, and dinner using criteria of balanced macronutrients at each meal per USDA MyPlate guidelines and minimal multi-ingredient mixed dishes.

    “Menu items were selected to serve to study participants at breakfast, lunch, and dinner, using the following criteria: balanced macronutrients at each meal per USDA MyPlate guidelines and minimal multi-ingredient mixed dishes (ie, no casseroles, lasagna, pizza, etc).”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim.

    Study design and conductnone given

    Continuous blood glucose was monitored as a strategy to measure and account for nonadherence to the study's dietary intake reporting protocols.

    “Continuous blood glucose was monitored as a strategy to measure and account for nonadherence to the study’s dietary intake reporting protocols.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing). May combine two claims.

    Study design and conductown data

    During phase 2, 2 participants completed 10 of 14 days because of scheduling conflicts and were included in the analyses.

    “During phase 2, 2 participants completed 10 of 14 days because of scheduling conflicts and were included in the analyses.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Study design and conductown data

    The reference method measured dietary intake by preparing, calibrating, and serving all meals at a campus dining facility and consuming them under direct observation of a trained research team.

    “A reference method was designed to measure dietary intake; all meals were prepared, calibrated, and served at a campus dining facility and consumed under the direct observation of a trained research team.”
    Quote in the paperSubstantial claim
  • May combine two claims.

    Interpretationown data

    Regression analyses indicated a tendency for the wristband to systematically overestimate for lower calorie intake and underestimate for higher intake.

    “Regression analyses indicated a tendency for the wristband to systematically overestimate for lower calorie intake and underestimate for higher intake.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: The reference method accurately measures true daily energy intake.
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductreasoning

    It was acceptable to charge the wristband at any point during the day as long as no food had been consumed for 3 hours prior.

    “It was acceptable to charge the wristband at any point during the day as long as no food had been consumed for 3 hours prior.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S2 (checkable), S3 (load-bearing).

    Interpretationown data

    Longer study periods could affect adherence issues without stricter guidelines around participant meal attendance.

    “Longer study periods could affect adherence issues without stricter guidelines around participant meal attendance.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim.

    Study design and conductreasoning

    Participants were instructed to charge the wristband fully before any meal to avoid missing food intake and its subsequent digestion.

    “Participants were instructed to charge the wristband fully before any meal to avoid missing food intake and its subsequent digestion (ie, charging band in the morning before consuming food for the day).”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductreasoning

    Several strategies were used to mitigate form factor challenges with the wristband.

    “Several strategies were used to mitigate these challenges with the form factor.”
    Quote in the paperNot a substantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductreasoning

    Research staff downloaded data files from the participants' sensors every 2 days to minimize any data loss.

    “The research staff downloaded data files from the participants’ sensors every 2 days to minimize any data loss.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim. May combine two claims.

    Study design and conductreasoning

    Separating ingredients allowed staff to weigh foods more precisely and calculate energy and macronutrient profiles accordingly.

    “Separating ingredients allowed the staff to weigh foods more precisely and calculate energy and macronutrient profiles accordingly.”
    Quote in the paperSubstantial claim
  • Classified as probably not a substantial claim. May combine two claims.

    Interpretationreasoning

    The deviations in and between methods could be explained by any combination of factors including form factor limitations, nonadherence to dietary protocol, interindividual differences in measured intake versus actual nutrient absorption and metabolism, human error in calculating food intake using the USDA Database, potential deviations from the standardized recipe, inability of the USDA Databaseto

    “The deviations in and between methods could be explained by any combination of the following factors:”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Premisecitation

    Establishing reliable adherence or compliance protocols is a widespread goal in measuring the dietary intake of human subjects.

    “Establishing reliable adherence or compliance protocols is a widespread goal in measuring the dietary intake of human subjects [23].”
    Quote in the paperNot a substantial claim0 of 1 sources checked
    • cites [23] source
  • Classified as probably not a substantial claim.

    Interpretationreasoning

    Achieving precision of reference methods for dietary intake measurement is a notable challenge.

    “The researchers acknowledge that because dietary intake measurement of individuals has inherent challenges related to accuracy and variability, achieving precision of reference methods is a notable challenge.”
    Quote in the paperSubstantial claim
    • Rests on an assumption: Dietary intake measurement of individuals has inherent challenges related to accuracy and variability.
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductnone given

    Participants who had significant interruptions were targeted for individual solutions to improve sensor contact with the wrist, for example, tightening the wristband to achieve optimal sensor positioning.

    “Those who had significant interruptions were targeted for individual solutions to improve sensor contact with the wrist, for example, tightening the wristband to achieve optimal sensor positioning.”
    Quote in the paperNot a substantial claim
  • Classified as probably not a substantial claim. May combine two claims.

    Study design and conductnone given

    Individual menu items were weighed and recorded using calibrated food scales, portioned using standardized tools, and served at each onsite meal.

    “Individual menu items were weighed and recorded (0.0 g) using calibrated food scales, portioned using standardized tools, and served at each onsite meal.”
    Quote in the paperSubstantial claim
  • Probably not a substantial claim: may not pass S3 (load-bearing).

    Study design and conductown data

    Of the total cases, 10.9% (33/304) were excluded because they lacked an accompanying set of complete CGM data for the 24-hour period.

    “Of the total cases, 10.9% (33/304) were excluded because they lacked an accompanying set of complete CGM data for the 24-hour period.”
    Quote in the paperNot a substantial claim
  • May combine two claims.

    Interpretationreasoning

    Any signal interruption during a meal or in the hours following it results in loss of data and underestimation of calorie intake by the wristband technology.

    “Practically, any signal interruption during the meal or in the hours following it would result in loss of data and underestimation of calorie intake by the technology.”
    Quote in the paperSubstantial claim
50 of 50
  • The paper relies on this without support.

    Few wearable/mobile sensor technologies are reliable for obtaining accurate and precise measurements of diet and nutrition.

    “Wearable and mobile sensor technologies can be useful tools in precision nutrition research and practice, but few are reliable for obtaining accurate and precise measurements of diet and nutrition.”
  • The paper relies on this without support.

    No technologies are available that can effectively assess dietary intake directly.

    “No technologies are available that can effectively assess dietary intake directly, although some methods are claiming the ability to estimate dietary intake by assessing the physiological response of the body to food intake and bioavailable energy.”
  • The paper relies on this without support.

    The 24-hour in-patient study is the gold standard of dietary assessment.

    “Currently, the gold standard of dietary assessment is the 24-hour in-patient study, yet major limitations include cost, reduced physical activity, boredom, depression, and weight loss because of reduced dietary freedom and food options deviating from one’s personal routine.”
  • The paper relies on this without support.

    The USDA Food Composition Database is the gold standard for nutrient analysis.

    “The United States Department of Agriculture (USDA) Food Composition Database is the gold standard for nutrient analysis; albeit comprehensive in scope, this tool cannot possibly account for inherent variability in climate, soil quality, geographic location, item ripeness, and cooking method, all of which may significantly alter the nutrient composition of food.”
  • The paper relies on this without support.

    The GoBe2 wristband technology uses computational algorithms to convert bioimpedance signals into measured patterns of extracellular and intracellular fluids associated with the influx of glucose and essential nutrients into the body.

    “The technology uses computational algorithms to convert bioimpedance signals into measured patterns of extracellular and intracellular fluids associated with the influx of glucose and essential nutrients into the body. From changes in fluid concentration, the technology estimates calories congruent with glucose absorption into the bloodstream.”
  • The paper relies on this without support.

    The reference method accurately measures true daily energy intake.

    “The Bland-Altman analysis was conducted to compare daily energy intake (kcal/day) estimated by both the reference method and the wristband technology.”
  • The paper relies on this without support.

    The dietary intake reports used as reference are accurate enough despite nonadherence, because CGM nonadherence data were not incorporated.

    “Although CGM was used to measure nonadherence to dietary intake reporting protocols, these data were not incorporated in the present dataset.”
  • The paper relies on this without support.

    The reference diet used in this study accurately represents participants' actual calorie intake.

    “This study validated participants’ calorie intake as recorded by the wearable device, in comparison with a reference diet.”
  • The paper relies on this without support.

    Dietary intake measurement of individuals has inherent challenges related to accuracy and variability.

    “dietary intake measurement of individuals has inherent challenges related to accuracy and variability”
  • The paper relies on this without support.

    Accurate and precise measurements of diet and nutrition are needed.

    “Tools are urgently needed to obtain accurate and precise measurements of diet and nutrition.”
  • The paper relies on this without support.

    The app market does not offer reliable solutions for automating the quantification of dietary intake that would significantly impact individualized quality of life decisions.

    “However, to date, the app market does not offer reliable solutions for automating the quantification of dietary intake that would significantly impact individualized quality of life decisions.”
  • The paper relies on this without support.

    Validation and effectiveness testing of candidate devices are essential steps to be taken for the use of precision technologies to inform personalized diet and lifestyle guidance.

    “Validation and effectiveness testing of candidate devices are essential steps to be taken for the use of precision technologies to inform personalized diet and lifestyle guidance.”
  • The paper relies on this without support.

    Enhancing knowledge about individual phenotypes allows for more precise and predictive dietary guidance and intervention.

    “Enhancing knowledge about individual phenotypes allows for more precise and predictive dietary guidance and intervention”
13 of 13

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Dimitratos, S. M., German, J. B., & Schaefer, S. E.
Affiliations
University of California, Davis (US)
Venue
JMIR mHealth and uHealth
Published
2020-07-22
Volume
8
Issue
7
Pages
e16405
ISSN
2291-5222 (ISSN-L)
OpenAlex
W3015373359
Cited by
27
References
29
Citations by year
2026: 5 · 2025: 12 · 2024: 3 · 2021: 7
FWCI
1.66
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • JMIR mhealth and uhealth (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • PubMed Central (submittedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Funders
University of California, Davis
Topics
  • Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Medicine › Physiology › Body Composition Measurement Techniques
Keywords
wearable devices, nutritional intake, dietary assessment, wrist-worn sensors, personalized nutrition, energy intake, macronutrient intake, measurement accuracy, reference method, mobile application, continuous glucose monitoring, dietary adherence
MeSH terms
Wearable Electronic Devices, Adult, Eating, Humans, Reproducibility of Results

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Claims read by deepseek-v4.1-flash under definition version 3 (extract-v3) on 2026-10-09.

Classified by jev-1.13-20260917 (gold-guideline-v0.2) on 2026-10-09.

Cited sources are checked by gpt-6-sol.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review