The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Dual-Energy CT–Based Monochromatic Imaging
Abstract
OBJECTIVE: We summarize how virtual monochromatic images are synthesized from dual-energy CT using image-domain and projection-domain methods. The quality of virtual monochromatic images is compared with that of polychromatic single-energy images acquired at different tube potentials and the same radiation dose. Clinical applications of dual-energy CT-based virtual monochromatic imaging are reviewed, including beam-hardening correction, contrast and noise optimization, metal artifact reduction, and material differentiation. CONCLUSION: Virtual monochromatic images synthesized from dual-energy CT data have the potential to reduce beam-hardening artifacts and to provide quantitative measurements. If there is no desire to obtain material-specific information or to correct for metal or beam-hardening artifacts from the dual-energy data, however, it is better to perform a conventional single-energy scan at the optimal tube potential.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy-selective reconstructions in X-ray computerised tomography
Alvarez, R. E., & Macovski, A. (1976) · Physics in Medicine & Biology · doi:10.1088/0031-9155/21/5/002 · Cited by 2,013
Material differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
Metal artifact reduction by dual energy computed tomography using monoenergetic extrapolation
Bamberg, F., Dierks, A., Nikolaou, K., Reiser, M. F., Becker, C. R., & Johnson, T. R. C. (2011) · European Radiology · doi:10.1007/s00330-011-2062-1 · Cited by 537
Evaluation of a prototype dual‐energy computed tomographic apparatus. I. Phantom studies
Kalender, W. A., Perman, W. H., Vetter, J. R., & Klotz, E. (1986) · Medical Physics · doi:10.1118/1.595958 · Cited by 451
Dual-Energy (Spectral) CT: Applications in Abdominal Imaging
Silva, A. C., Morse, B. G., Hara, A. K., Paden, R. G., Hongo, N., & Pavlicek, W. (2011) · RadioGraphics · doi:10.1148/rg.314105159 · Cited by 351
Virtual monochromatic imaging in dual‐source dual‐energy CT: Radiation dose and image quality
Yu, L., Christner, J. A., Leng, S., Wang, J., Fletcher, J. G., & McCollough, C. H. (2011) · Medical Physics · doi:10.1118/1.3658568 · Cited by 343
Self-citationDual Energy CT Characterization of Urinary Calculi: Initial In Vitro and Clinical Experience
Graser, A., Johnson, T. R. C., Bader, M., Staehler, M., Haseke, N., Nikolaou, K., Reiser, M. F., Stief, C. G., & Becker, C. R. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e318157a144 · Cited by 341
Glazebrook, K. N., Guimarães, L. S., Murthy, N. S., Black, D. F., Bongartz, T., J. Manek, N., Leng, S., Fletcher, J. G., & McCollough, C. H. (2011) · Radiology · doi:10.1148/radiol.11102485 · Cited by 242
Self-citationAutomatic selection of tube potential for radiation dose reduction in CT: A general strategy
Yu, L., Li, H., Fletcher, J. G., & McCollough, C. H. (2010) · Medical Physics · doi:10.1118/1.3264614 · Cited by 230
Self-citationLee, Y. H., Park, K. K., Song, H.-T., Kim, S., & Suh, J.-S. (2012) · European Radiology · doi:10.1007/s00330-011-2370-5 · Cited by 207
Application‐ and patient size‐dependent optimization of x‐ray spectra for CT
Kalender, W. A., Deak, P., Kellermeier, M., van Straten, M., & Vollmar, S. V. (2009) · Medical Physics · doi:10.1118/1.3075901 · Cited by 206
Dual-Energy CT as a Potential New Diagnostic Tool in the Management of Gout in the Acute Setting
Nicolaou, S., Yong-Hing, C. J., Galea-Soler, S., Hou, D. J., Louis, L., & Munk, P. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.09.2428 · Cited by 175
Empirical beam hardening correction (EBHC) for CT
Kyriakou, Y., Meyer, E., Prell, D., & Kachelrieß, M. (2010) · Medical Physics · doi:10.1118/1.3477088 · Cited by 171
Ruzsics, B., Schwarz, F., Schoepf, U. J., Lee, Y. S., Bastarrika, G., Chiaramida, S. A., Costello, P., & Zwerner, P. L. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.03.051 · Cited by 171
Zhou, C., Zhao, Y. E., Luo, S., Shi, H., li, L., Zheng, L., Zhang, L. J., & Lu, G. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.05.009 · Cited by 161
Guimarães, L., Fletcher, J. G., Harmsen, W. S., Yu, L., Siddiki, H. A., Melton, Z., Huprich, J. E., Hough, D. M., Hartman, R. P., & McCollough, C. H. (2010) · Radiology · doi:10.1148/radiol.10092016 · Cited by 146
Self-citationBrook, O. R., Gourtsoyiannis, N., Brook, A., Mahadevan, A., Wilcox, C. J., & Raptopoulos, V. D. (2012) · Radiology · doi:10.1148/radiol.12111170 · Cited by 98
Morgan, D. E. (2013) · Abdominal Imaging · doi:10.1007/s00261-013-0033-5 · Cited by 79
Evans, J. D., Whiting, B. R., O’Sullivan, J. A., Politte, D. G., Klahr, P., Yu, Y., & Williamson, J. F. (2013) · Medical Physics · doi:10.1118/1.4828787 · Cited by 12
Dual-energy CT: Principles, clinical value and potential applications in forensic imaging
Alkadhi, H., & Leschka, S. (2013) · Journal of Forensic Radiology and Imaging · doi:10.1016/j.jofri.2013.07.003 · Cited by 6
Agrawal, M. D., Agarwal, S., Fuentes-Oreego, J. M., Hayano, K., & Sahani, D. V. (2013) · Current Radiology Reports · doi:10.1007/s40134-013-0028-6 · Cited by 6
Cited by
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Self-citationWillemink, M. J., & Noël, P. B. (2019) · European Radiology · doi:10.1007/s00330-018-5810-7 · Cited by 603
Dual-Energy CT: New Horizon in Medical Imaging
Goo, H. W., & Goo, J. M. (2017) · Korean Journal of Radiology · doi:10.3348/kjr.2017.18.4.555 · Cited by 408
State of the Art: Dual-Energy CT of the Abdomen
Marin, D., Boll, D. T., Mileto, A., & Nelson, R. C. (2014) · Radiology · doi:10.1148/radiol.14131480 · Cited by 368
Current and Novel Techniques for Metal Artifact Reduction at CT: Practical Guide for Radiologists
Katsura, M., Sato, J., Akahane, M., Kunimatsu, A., & Abe, O. (2018) · RadioGraphics · doi:10.1148/rg.2018170102 · Cited by 343
Metadata
- Authors
- Yu, L., Leng, S., & McCollough, C. H.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 2012-11
- Volume
- 199
- Issue
- 5_supplement
- Pages
- S9-S15
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2040337964
- Cited by
- 609
- References
- 21
- FWCI
- 14.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.