Diffusion-weighted MR imaging with a single-shot echoplanar sequence: detection and characterization of focal hepatic lesions.
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The purpose of this study was to determine the usefulness of diffusion-weighted MR imaging with single-shot echoplanar imaging in characterizing focal hepatic lesions by apparent diffusion coefficient (ADC) and contrast-to-noise ratio (CNR) measurements. MATERIALS AND METHODS: Diffusion-weighted imaging on a 1.5-T MR unit was performed in 46 patients with 74 known focal hepatic lesions (11 hemangiomas, 15 metastases, and 48 hepatocellular carcinomas [HCCs]). Mean values for ADCs and CNRs of all lesions were calculated. Mean values for CNRs with diffusion-weighted imaging were also compared with those for breath-hold T2-weighted fast spin-echo images. RESULTS: The mean values for ADCs were different for each type of tumor (5.39 x 10(-3) mm2/sec +/- 1.23 in hemangiomas, 2.85 x 10(-3) mm2/sec +/- 0.59 in metastases, and 3.84 x 10(-3) mm2/sec +/- 0.92 in HCCs), and each of them was significantly greater than the mean values for ADCs of the normal liver (2.28 x 10(-3) mm2/sec +/- 1.23 in normal liver [p < .05] except metastasis versus normal liver [p < .1]). Also, the mean values for ADCs were based on differences of ADC values. Only four (6%) of 63 malignant tumors (three HCCs and one metastasis) could not be differentiated from hemangiomas. The mean value for CNRs with diffusion-weighted images (14.4 +/- 8.54 in HCC and 29.0 +/- 6.79 in metastasis) was significantly higher than the mean values for CNRs obtained with T2-weighted fast spin-echo images in both metastases and HCCs (p < .05), whereas no significant difference was seen for hemangiomas. CONCLUSION: Mean values for ADCs differed for the three types of the hepatic lesions and were higher than ADCs of the normal liver. We suggest that diffusion-weighted imaging may be useful for increased detection of HCCs and metastases and in distinguishing these entities from hemangiomas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Diffusion MR imaging: clinical applications.
Le Bihan, D., Turner, R., Douek, P., & Patronas, N. (1992) · American Journal of Roentgenology · doi:10.2214/ajr.159.3.1503032 · Cited by 489
Abdominal diffusion mapping with use of a whole-body echo-planar system.
Müller, M. F., Prasad, P., Siewert, B., Nissenbaum, M. A., Raptopoulos, V, & Edelman, R. R. (1994) · Radiology · doi:10.1148/radiology.190.2.8284402 · Cited by 245
Functional imaging of the kidney by means of measurement of the apparent diffusion coefficient.
Müller, M. F., Prasad, P. V., Bimmler, D., Kaiser, A., & Edelman, R. R. (1994) · Radiology · doi:10.1148/radiology.193.3.7972811 · Cited by 181
Real‐time movie imaging from a single cardiac cycle by NMR
Chapman, B. L. W., Turner, R., Ordidge, R. J., Doyle, M., Cawley, M. G., Coxon, R., Glover, P. M., & Mansfield, P. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050305 · Cited by 168
CT of hepatic masses: significance of prolonged and delayed enhancement
Itai, Y., Ohtomo, K., Kokubo, T., Yamauchi, T., Minami, M., Yashiro, N., & Araki, T. (1986) · American Journal of Roentgenology · doi:10.2214/ajr.146.4.729 · Cited by 103
Self-citationGoldberg, M. A., Hahn, P. F., Saini, S., Cohen, M. S., Reimer, P., Brady, T. J., & Mueller, P. R. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.160.5.8470568 · Cited by 95
Rydberg, J. N., Lomas, D. J., Coakley, K. J., Hough, D. M., Ehman, R. L., & Riederer, S. J. (1995) · Radiology · doi:10.1148/radiology.194.2.7824723 · Cited by 85
Accuracy of radiology in detection of hepatocellular carcinoma before liver transplantation
Rizzi, P. M., Kane, P. A., Ryder, S. D., Ramage, J. K., Gane, E. J., Tan, K. C., Portmann, B. C., Karani, J. B., & Williams, R. L. (1994) · Gastroenterology · doi:10.1016/0016-5085(94)90545-2 · Cited by 81
Saini, S., Reimer, P., Hahn, P. F., & Cohen, M. S. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.163.6.7992735 · Cited by 32
Moteki, T., Ishizaka, H., Horikoshi, H., & Matsumoto, M. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050214 · Cited by 26
Cited by
Diffusion tensor imaging: Concepts and applications
Le Bihan, D., Mangin, J., Poupon, C., Clark, C. A., Pappata, S., Molko, N., & Chabriat, H. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1076 · Cited by 3,547
Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
Padhani, A. R., Liu, G., Mu-Koh, D., Chenevert, T. L., Thoeny, H. C., Takahara, T., Dzik-Jurasz, A., Ross, B. D., Van Cauteren, M., Collins, D., et al. (2009) · Neoplasia · doi:10.1593/neo.81328 · Cited by 1,989
Towards multidimensional radiotherapy (MD-CRT): biological imaging and biological conformality
Ling, C. C., Humm, J., Larson, S., Amols, H., Fuks, Z., Leibel, S., & Koutcher, J. A. (2000) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(00)00467-3 · Cited by 926
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Differentiation of clinically benign and malignant breast lesions using diffusion‐weighted imaging
Guo, Y., Cai, Y., Cai, Z., Gao, Y., An, N., Ma, L., Mahankali, S., & Gao, J. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10140 · Cited by 714
Taouli, B., Vilgrain, V., Dumont, E., Daire, J.-L., Fan, B., & Menu, Y. (2003) · Radiology · doi:10.1148/radiol.2261011904 · Cited by 577
Parikh, T., Drew, S. J., Lee, V. S., Wong, S., Hecht, E. M., Babb, J. S., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070432 · Cited by 560
Yamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
Kwee, T. C., Takahara, T., Ochiai, R., Nievelstein, R. A. J., & Luijten, P. R. (2008) · European Radiology · doi:10.1007/s00330-008-0968-z · Cited by 410
Patel, J., Sigmund, E. E., Rusinek, H., Oei, M., Babb, J. S., & Taouli, B. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22081 · Cited by 371
Technology Insight: water diffusion MRI—a potential new biomarker of response to cancer therapy
Patterson, D. M., Padhani, A. R., & Collins, D. J. (2008) · Nature Clinical Practice Oncology · doi:10.1038/ncponc1073 · Cited by 365
Diffusion-weighted single-shot echoplanar MR imaging for liver disease.
Kim, T., Murakami, T., Takahashi, S., Hori, M., Tsuda, K., & Nakamura, H. (1999) · American Journal of Roentgenology · doi:10.2214/ajr.173.2.10430143 · Cited by 349
Sato, C., Naganawa, S., Nakamura, T., Kumada, H., Miura, S., Takizawa, O., & Ishigaki, T. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20251 · Cited by 323
Hepatic Metastases: Diffusion-weighted Sensitivity-encoding versus SPIO-enhanced MR Imaging
Nasu, K., Kuroki, Y., Nawano, S., Kuroki, S., Tsukamoto, T., Yamamoto, S., Motoori, K., & Ueda, T. (2006) · Radiology · doi:10.1148/radiol.2383041384 · Cited by 322
Renal Lesions: Characterization with Diffusion-weighted Imaging versus Contrast-enhanced MR Imaging
Taouli, B., Thakur, R. K., Mannelli, L., Babb, J. S., Kim, S., Hecht, E. M., Lee, V. S., & Israel, G. M. (2009) · Radiology · doi:10.1148/radiol.2512080880 · Cited by 322
Tamai, K., Koyama, T., Saga, T., Morisawa, N., Fujimoto, K., Mikami, Y., & Togashi, K. (2008) · European Radiology · doi:10.1007/s00330-007-0787-7 · Cited by 312
ADC Measurement of Abdominal Organs and Lesions Using Parallel Imaging Technique
Yoshikawa, T., Kawamitsu, H., Mitchell, D. G., Ohno, Y., Ku, Y., Seo, Y., Fujii, M., & Sugimura, K. (2006) · American Journal of Roentgenology · doi:10.2214/ajr.05.0778 · Cited by 300
Intravoxel Incoherent Motion Perfusion MR Imaging: A Wake-Up Call
Le Bihan, D. (2008) · Radiology · doi:10.1148/radiol.2493081301 · Cited by 298
Diffusion-weighted magnetic resonance imaging for the assessment of fibrosis in chronic hepatitis C
Lewin, M., Poujol-Robert, A., Boëlle, P.-Y., Wendum, D., Lasnier, E., Viallon, M., Guéchot, J., Hoeffel, C., Arrivé, L., Tubiana, J.-M., et al. (2007) · Hepatology · doi:10.1002/hep.21747 · Cited by 265
Naganawa, S., Sato, C., Kumada, H., Ishigaki, T., Miura, S., & Takizawa, O. (2005) · European Radiology · doi:10.1007/s00330-004-2529-4 · Cited by 258
Practical Aspects of Assessing Tumors Using Clinical Diffusion-weighted Imaging in the Body
KOH, D.-M., TAKAHARA, T., IMAI, Y., & COLLINS, D. J. (2007) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.6.211 · Cited by 211
Catalano, O. A., Choy, G., Zhu, A., Hahn, P. F., & Sahani, D. V. (2010) · Radiology · doi:10.1148/radiol.09090304 · Cited by 210
Advanced MRI Methods for Assessment of Chronic Liver Disease
Taouli, B., Ehman, R. L., & Reeder, S. B. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2601 · Cited by 197
Nonalcoholic fatty liver disease
Erickson, S. K. (2009) · Journal of Lipid Research · doi:10.1194/jlr.r800089-jlr200 · Cited by 194
Utility of diffusion‐weighted MRI in distinguishing benign and malignant hepatic lesions
Miller, F. H., Hammond, N., Siddiqi, A. J., Shroff, S., Khatri, G., Wang, Y., Merrick, L. B., & Nikolaidis, P. (2010) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22235 · Cited by 188
“Ichikawa et al (10) reported a significant difference for HCC vs.”
BackgroundTaouli, B., Sandberg, A., Stemmer, A., Parikh, T., Wong, S., Xu, J., & Lee, V. S. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21876 · Cited by 167
Coenegrachts, K., Delanote, J., Ter Beek, L., Haspeslagh, M., Bipat, S., Stoker, J., Van Kerkhove, F., Steyaert, L., Rigauts, H., & W Casselman, J. (2007) · The British Journal of Radiology · doi:10.1259/bjr/33156643 · Cited by 149
Metadata
- Authors
- Ichikawa, T., Haradome, H., Hachiya, J., Nitatori, T., & Araki, T.
- Venue
- American Journal of Roentgenology
- Publisher
- American Roentgen Ray Society
- Published
- 1998-02
- Volume
- 170
- Issue
- 2
- Pages
- 397-402
- ISSN
- 0002-9580 (ISSN-L)
- 0361-803X
- 1546-3141
- OpenAlex
- W2033412857
- Cited by
- 314
- References
- 11
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.