Imaging Depths of Near-Infrared Quantum Dots in First and Second Optical Windows
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Potential advantages of quantum dot (QD) imaging in the second optical window (SOW) at 1,000 to 1,400 nm over the first optical window (FOW) at 700 to 900 nm have attracted much interest. QDs that emit at 800 nm (800QDs) and QDs that emit at 1,300 nm (1,300QDs) are used to investigate the imaging depths at the FOW and SOW. QD images in biologic tissues are processed binarized via global thresholding method, and the imaging depths are determined using the criteria of contrast to noise ratio and relative apparent size. Owing to the reduced scattering in the SOW, imaging depth in skin can be extended by approximately three times for 1,300QD/SOW over 800QD/FOW. In liver, excitation of 1,300QD/SOW can be shifted to longer wavelengths; thus, the imaging depth can be extended by 1.4 times. Effects of quantum yield (QY), concentration, incidence angle, polarization, and fluence rate F on imaging depth are comprehensively studied. Under F approved by the Food and Drug Administration, 1,300QDs with 50% QY can reach imaging depths of 29.7 mm in liver and 17.5 mm in skin. A time-gated excitation using 1,000 times higher F pulses can obtain the imaging depth of ≈ 5 cm. To validate our estimates, in vivo whole-body imaging experiments are performed using small-animal models.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848 · cited 1×
“The NIR optical window can be divided into the first optical window (FOW; 700 # l # 900 nm) and the second optical window (SOW; 1,000 # l # 1,400 nm).(7) The SOW is more advantageous for imaging than the FOW because of the lower scattering level.”
BackgroundA review of the optical properties of biological tissues
Cheong, W. F., Prahl, S. A., & Welch, A. J. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64354 · Cited by 2,530 · cited 3×
“This may be due to multiply scattered photons: because forward-directed scattering is dominant in biologic tissues, an incidence angle geometry that allows photons to reach the detector after multiple scatterings with higher probability should result in higher background noise and consequently smaller CNRs and larger…”
BackgroundInfluentialA route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Cited by
Nanomaterials for In Vivo Imaging
Smith, B. R., & Gambhir, S. S. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00073 · Cited by 1,075
Through-skull fluorescence imaging of the brain in a new near-infrared window
Hong, G., Diao, S., Chang, J., Antaris, A. L., Chen, C., Zhang, B., Zhao, S., Atochin, D. N., Huang, P. L., Andreasson, K. I., et al. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.166 · Cited by 1,061
Plasmonic Photothermal Nanoparticles for Biomedical Applications
Kim, M., Lee, J., & Nam, J. (2019) · Advanced Science · doi:10.1002/advs.201900471 · Cited by 751
Hemmer, E., Benayas, A., Légaré, F., & Vetrone, F. (2016) · Nanoscale Horizons · doi:10.1039/c5nh00073d · Cited by 731
Hong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Miao, Q., & Pu, K. (2018) · Advanced Materials · doi:10.1002/adma.201801778 · Cited by 537
Li, C., Zhang, Y., Wang, M., Zhang, Y., Chen, G., Li, L., Wu, D., & Wang, Q. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2013.10.010 · Cited by 428
Antimicrobial Metal Nanomaterials: From Passive to Stimuli‐Activated Applications
Cheeseman, S., Christofferson, A. J., Kariuki, R., Cozzolino, D., Daeneke, T., Crawford, R. J., Truong, V. K., Chapman, J., & Elbourne, A. (2020) · Advanced Science · doi:10.1002/advs.201902913 · Cited by 337
Novel benzo-bis(1,2,5-thiadiazole) fluorophores for in vivo NIR-II imaging of cancer
Sun, Y., Qu, C., Chen, H., He, M., Tang, C., Shou, K., Hong, S., Yang, M., Jiang, Y., Ding, B., et al. (2016) · Chemical Science · doi:10.1039/c6sc01561a · Cited by 294
Light-sheet microscopy in the near-infrared II window
Wang, F., Wan, H., Ma, Z., Zhong, Y., Sun, Q., Tian, Y., Qu, L., Du, H., Zhang, M., Li, L., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0398-7 · Cited by 237
Shortwave Infrared Imaging with J-Aggregates Stabilized in Hollow Mesoporous Silica Nanoparticles
Chen, W., Cheng, C.-A., Cosco, E. D., Ramakrishnan, S., Lingg, J. G. P., Bruns, O. T., Zink, J. I., & Sletten, E. M. (2019) · Journal of the American Chemical Society · doi:10.1021/jacs.9b05195 · Cited by 202
In vivo NIR-II structured-illumination light-sheet microscopy
Wang, F., Ma, Z., Zhong, Y., Salazar, F., Xu, C., Ren, F., Qu, L., Wu, A. M., & Dai, H. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2023888118 · Cited by 85
Metadata
- Authors
- Won, N., Jeong, S., Kim, K., Kwag, J., Park, J., Kim, S. G., & Kim, S.
- Venue
- Molecular Imaging
- Publisher
- SAGE Publications
- Published
- 2012-07-01
- Volume
- 11
- Issue
- 4
- Pages
- 338-52
- ISSN
- 1535-3508 (ISSN-L)
- 1536-0121
- OpenAlex
- W68409387
- Cited by
- 80
- References
- 5
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.