The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Evaluation of a System for Automatic Detection of Diabetic Retinopathy From Color Fundus Photographs in a Large Population of Patients With Diabetes
Open accessAbstract
OBJECTIVE—To evaluate the performance of a system for automated detection of diabetic retinopathy in digital retinal photographs, built from published algorithms, in a large, representative, screening population. RESEARCH DESIGN AND METHODS—We conducted a retrospective analysis of 10,000 consecutive patient visits, specifically exams (four retinal photographs, two left and two right) from 5,692 unique patients from the EyeCheck diabetic retinopathy screening project imaged with three types of cameras at 10 centers. Inclusion criteria included no previous diagnosis of diabetic retinopathy, no previous visit to ophthalmologist for dilated eye exam, and both eyes photographed. One of three retinal specialists evaluated each exam as unacceptable quality, no referable retinopathy, or referable retinopathy. We then selected exams with sufficient image quality and determined presence or absence of referable retinopathy. Outcome measures included area under the receiver operating characteristic curve (number needed to miss one case [NNM]) and type of false negative. RESULTS—Total area under the receiver operating characteristic curve was 0.84, and NNM was 80 at a sensitivity of 0.84 and a specificity of 0.64. At this point, 7,689 of 10,000 exams had sufficient image quality, 4,648 of 7,689 (60%) were true negatives, 59 of 7,689 (0.8%) were false negatives, 319 of 7,689 (4%) were true positives, and 2,581 of 7,689 (33%) were false positives. Twenty-seven percent of false negatives contained large hemorrhages and/or neovascularizations. CONCLUSIONS—Automated detection of diabetic retinopathy using published algorithms cannot yet be recommended for clinical practice. However, performance is such that evaluation on validated, publicly available datasets should be pursued. If algorithms can be improved, such a system may in the future lead to improved prevention of blindness and vision loss in patients with diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2007) · Developments in Ophthalmology · doi:10.1159/isbn.978-3-318-01439-6 · Cited by 5,583
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Self-citationWilkinson, C. P., Ferris, F. L., Klein, R. E., Lee, P. P., Agardh, C. D., Davis, M., Dills, D., Kampik, A., Pararajasegaram, R., & Verdaguer, J. T. (2003) · Ophthalmology · doi:10.1016/s0161-6420(03)00475-5 · Cited by 3,743
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Early Photocoagulation for Diabetic Retinopathy
(1991) · Ophthalmology · doi:10.1016/s0161-6420(13)38011-7 · Cited by 1,259
Fong, D. S., Aiello, L., Gardner, T. W., King, G. L., Blankenship, G., Cavallerano, J. D., Ferris, F. L., Klein, R., & for the American Diabetes Association (2004) · Diabetes Care · doi:10.2337/diacare.27.2007.s84 · Cited by 1,082
Fundus Photographic Risk Factors for Progression of Diabetic Retinopathy
(1991) · Ophthalmology · doi:10.1016/s0161-6420(13)38014-2 · Cited by 814
Comparative study of retinal vessel segmentation methods on a new publicly available database
Niemeijer, M., Staal, J., van Ginneken, B., Loog, M., & Abramoff, M. D. (2004) · SPIE Proceedings · doi:10.1117/12.535349 · Cited by 790
Self-citationLocating the optic nerve in a retinal image using the fuzzy convergence of the blood vessels
Hoover, A., & Goldbaum, M. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815900 · Cited by 787
Retinal image analysis: Concepts, applications and potential
Patton, N., Aslam, T. M., MacGillivray, T., Deary, I. J., Dhillon, B., Eikelboom, R. H., Yogesan, K., & Constable, I. J. (2006) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2005.07.001 · Cited by 641
Cited by
Ting, D. S. W., Cheung, C. Y.-L., Lim, G., Tan, G. S. W., Quang, N. D., Gan, A., Hamzah, H., Garcia-Franco, R., San Yeo, I. Y., Lee, S. Y., et al. (2017) · JAMA · doi:10.1001/jama.2017.18152 · Cited by 2,402
Abràmoff, M. D., Lavin, P. T., Birch, M., Shah, N., & Folk, J. C. (2018) · npj Digital Medicine · doi:10.1038/s41746-018-0040-6 · Cited by 1,638
Self-citationArtificial intelligence and deep learning in ophthalmology
Ting, D. S. W., Pasquale, L. R., Peng, L., Campbell, J. P., Lee, A. Y., Raman, R., Tan, G. S. W., Schmetterer, L., Keane, P. A., & Wong, T. Y. (2019) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2018-313173 · Cited by 1,554
Artificial Intelligence and Deep Learning in Ophthalmology
Wang, Z., Keane, P. A., Chiang, M., Cheung, C. Y., Wong, T. Y., & Ting, D. S. W. (2022) · Artificial Intelligence in Medicine · doi:10.1007/978-3-030-64573-1_200 · Cited by 1,524
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Self-citationNiemeijer, M., van Ginneken, B., Cree, M. J., Mizutani, A., Quellec, G., Sanchez, C. I., Zhang, B., Hornero, R., Lamard, M., Muramatsu, C., et al. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2033909 · Cited by 516
Self-citationRajalakshmi, R., Subashini, R., Anjana, R. M., & Mohan, V. (2018) · Eye · doi:10.1038/s41433-018-0064-9 · Cited by 462
Automated Analysis of Retinal Images for Detection of Referable Diabetic Retinopathy
Abràmoff, M. D., Folk, J. C., Han, D. P., Walker, J. D., Williams, D. F., Russell, S. R., Massin, P., Cochener, B., Gain, P., Tang, L., et al. (2013) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2013.1743 · Cited by 463
Self-citationComputer-aided diagnosis of diabetic retinopathy: A review
Mookiah, M. R. K., Acharya, U. R., Chua, C. K., Lim, C. M., Ng, E. Y. K., & Laude, A. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.10.007 · Cited by 430
DREAM: Diabetic Retinopathy Analysis Using Machine Learning
Roychowdhury, S., Koozekanani, D. D., & Parhi, K. K. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2294635 · Cited by 413
An Ensemble-Based System for Microaneurysm Detection and Diabetic Retinopathy Grading
Antal, B., & Hajdu, A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2193126 · Cited by 335
Exudate-based diabetic macular edema detection in fundus images using publicly available datasets
Giancardo, L., Meriaudeau, F., Karnowski, T. P., Li, Y., Garg, S., Tobin, K. W., & Chaum, E. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.07.004 · Cited by 322
Computer-aided Diagnosis: How to Move from the Laboratory to the Clinic
van Ginneken, B., Schaefer-Prokop, C. M., & Prokop, M. (2011) · Radiology · doi:10.1148/radiol.11091710 · Cited by 306
Algorithms for the Automated Detection of Diabetic Retinopathy Using Digital Fundus Images: A Review
Faust, O., Acharya U., R., Ng, E. Y. K., Ng, K.-H., & Suri, J. S. (2012) · Journal of Medical Systems · doi:10.1007/s10916-010-9454-7 · Cited by 303
Automated Early Detection of Diabetic Retinopathy
Abràmoff, M. D., Reinhardt, J. M., Russell, S. R., Folk, J. C., Mahajan, V. B., Niemeijer, M., & Quellec, G. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.03.046 · Cited by 287
Self-citationMultiscale AM-FM Methods for Diabetic Retinopathy Lesion Detection
Agurto, C., Murray, V., Barriga, E., Murillo, S., Pattichis, M., Davis, H., Russell, S., Abramoff, M., & Soliz, P. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2037146 · Cited by 259
Self-citationAn ensemble-based system for automatic screening of diabetic retinopathy
Antal, B., & Hajdu, A. (2014) · Knowledge-Based Systems · doi:10.1016/j.knosys.2013.12.023 · Cited by 256
Bhaskaranand, M., Ramachandra, C., Bhat, S., Cuadros, J., Nittala, M. G., Sadda, S. R., & Solanki, K. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2019.0164 · Cited by 211
Lim, G., Bellemo, V., Xie, Y., Lee, X. Q., Yip, M. Y. T., & Ting, D. S. W. (2020) · Eye and Vision · doi:10.1186/s40662-020-00182-7 · Cited by 96
Hansen, M. B., Abràmoff, M. D., Folk, J. C., Mathenge, W., Bastawrous, A., & Peto, T. (2015) · PLOS ONE · doi:10.1371/journal.pone.0139148 · Cited by 93
Self-citation
Metadata
- Authors
- Abràmoff, M. D., Niemeijer, M., Suttorp-Schulten, M. S. A., Viergever, M. A., Russell, S. R., & van Ginneken, B.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2008-02-01
- Volume
- 31
- Issue
- 2
- Pages
- 193-198
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2136289855
- Cited by
- 277
- References
- 38
- FWCI
- 16.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.