Clinical Evaluation of a Personalized Artificial Pancreas
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: An artificial pancreas (AP) that automatically regulates blood glucose would greatly improve the lives of individuals with diabetes. Such a device would prevent hypo- and hyperglycemia along with associated long- and short-term complications as well as ease some of the day-to-day burden of frequent blood glucose measurements and insulin administration. RESEARCH DESIGN AND METHODS: We conducted a pilot clinical trial evaluating an individualized, fully automated AP using commercial devices. Two trials (n = 22, nsubjects = 17) were conducted using a multiparametric formulation of model predictive control and an insulin-on-board algorithm such that the control algorithm, or “brain,” can be embedded on a chip as part of a future mobile device. The protocol evaluated the control algorithm for three main challenges: 1) normalizing glycemia from various initial glucose levels, 2) maintaining euglycemia, and 3) overcoming an unannounced meal of 30 ± 5 g carbohydrates. RESULTS: Initial glucose values ranged from 84–251 mg/dL. Blood glucose was kept in the near-normal range (80–180 mg/dL) for an average of 70% of the trial time. The low and high blood glucose indices were 0.34 and 5.1, respectively. CONCLUSIONS: These encouraging short-term results reveal the ability of a control algorithm tailored to an individual’s glucose characteristics to successfully regulate glycemia, even when faced with unannounced meals or initial hyperglycemia. To our knowledge, this represents the first truly fully automated multiparametric model predictive control algorithm with insulin-on-board that does not rely on user intervention to regulate blood glucose in individuals with type 1 diabetes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
A Bihormonal Closed-Loop Artificial Pancreas for Type 1 Diabetes
El-Khatib, F. H., Russell, S. J., Nathan, D. M., Sutherlin, R. G., & Damiano, E. R. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3000619 · Cited by 403 · cited 2×
“Other studies have used a dual-hormone approach to mimic normal physiology and reduce the likelihood of postprandial hypoglycemia because of excessive insulin administration (6,9).”
BackgroundMethodClosed-loop insulin delivery from bench to clinical practice
Hovorka, R. (2011) · Nature Reviews Endocrinology · doi:10.1038/nrendo.2011.32 · Cited by 342
Hovorka, R., Kumareswaran, K., Harris, J., Allen, J. M., Elleri, D., Xing, D., Kollman, C., Nodale, M., Murphy, H. R., Dunger, D. B., et al. (2011) · BMJ · doi:10.1136/bmj.d1855 · Cited by 244
Novel Use of Glucagon in a Closed-Loop System for Prevention of Hypoglycemia in Type 1 Diabetes
Castle, J. R., Engle, J. M., Youssef, J. E., Massoud, R. G., Yuen, K. C. J., Kagan, R., & Ward, W. K. (2010) · Diabetes Care · doi:10.2337/dc09-2254 · Cited by 232
Kovatchev, B., Cobelli, C., Renard, E., Anderson, S., Breton, M., Patek, S., Clarke, W., Bruttomesso, D., Maran, A., Costa, S., et al. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400611 · Cited by 200 · cited 1×
“Either a manual glucose reading from the CGM, manual administration of insulin by the study personnel, or both was used (4,6,9,14,15), or a three-pump system with manual venous blood glucose input was implemented (6).”
MethodClarke, W. L., Anderson, S., Breton, M., Patek, S., Kashmer, L., & Kovatchev, B. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300506 · Cited by 185 · cited 1×
“Either a manual glucose reading from the CGM, manual administration of insulin by the study personnel, or both was used (4,6,9,14,15), or a three-pump system with manual venous blood glucose input was implemented (6).”
Method
Cited by
Closed-Loop Artificial Pancreas Systems: Engineering the Algorithms
Doyle, F. J., Huyett, L. M., Lee, J. B., Zisser, H. C., & Dassau, E. (2014) · Diabetes Care · doi:10.2337/dc13-2108 · Cited by 394
Self-citationClosed-Loop Insulin Delivery during Pregnancy in Women with Type 1 Diabetes
Stewart, Z. A., Wilinska, M. E., Hartnell, S., Temple, R. C., Rayman, G., Stanley, K. P., Simmons, D., Law, G. R., Scott, E. M., Hovorka, R., et al. (2016) · New England Journal of Medicine · doi:10.1056/nejmoa1602494 · Cited by 279
One Year Real-World Use of the Control-IQ Advanced Hybrid Closed-Loop Technology
Breton, M. D., & Kovatchev, B. P. (2021) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2021.0097 · Cited by 250
Kovatchev, B. P., Renard, E., Cobelli, C., Zisser, H. C., Keith-Hynes, P., Anderson, S. M., Brown, S. A., Chernavvsky, D. R., Breton, M. D., Mize, L. B., et al. (2014) · Diabetes Care · doi:10.2337/dc13-2076 · Cited by 178
Self-citationThe artificial pancreas: current status and future prospects in the management of diabetes
Peyser, T., Dassau, E., Breton, M., & Skyler, J. S. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12431 · Cited by 169
Self-citationTurksoy, K., Bayrak, E. S., Quinn, L., Littlejohn, E., & Cinar, A. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0283 · Cited by 161
Kovatchev, B., Cheng, P., Anderson, S. M., Pinsker, J. E., Boscari, F., Buckingham, B. A., Doyle, F. J., Hood, K. K., Brown, S. A., Breton, M. D., et al. (2017) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2016.0333 · Cited by 141
Self-citationGingras, V., Taleb, N., Roy‐Fleming, A., Legault, L., & Rabasa‐Lhoret, R. (2018) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.13052 · Cited by 113
Harvey, R. A., Dassau, E., Zisser, H., Seborg, D. E., & Doyle, F. J. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814523881 · Cited by 68
Self-citationAschbacher, K., Rodriguez-Fernandez, M., van Wietmarschen, H., Tomiyama, A. J., Jain, S., Epel, E., Doyle, F. J., & van der Greef, J. (2014) · Interface Focus · doi:10.1098/rsfs.2014.0020 · Cited by 48
Metadata
- Authors
- Dassau, E., Zisser, H., Harvey, R. A., Percival, M. W., Grosman, B., Bevier, W., Atlas, E., Miller, S., Nimri, R., Jovanovič, L., & Doyle, F. J.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2013-03-14
- Volume
- 36
- Issue
- 4
- Pages
- 801-809
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2154410696
- Cited by
- 120
- References
- 7
- FWCI
- 11.51
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.