Real-Time Continuous Glucose Monitoring Among Participants in the T1D Exchange Clinic Registry
Open accessThe DOI matches its Crossref record; 18 of the 19 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To assess the frequency of continuous glucose monitoring (CGM) device use, factors associated with its use, and the relationship of CGM with diabetes outcomes (HbA1c, severe hypoglycemia [SH], and diabetic ketoacidosis [DKA]). RESEARCH DESIGN AND METHODS: Survey questions related to CGM device use 1 year after enrollment in the T1D Exchange clinic registry were completed by 17,317 participants. Participants were defined as CGM users if they indicated using real-time CGM during the prior 30 days. RESULTS: Nine percent of participants used CGM (6% of children <13 years old, 4% of adolescents 13 to <18 years, 6% of young adults 18 to <26 years, and 21% of adults ≥26 years). CGM use was more likely with higher education, higher household income, private health insurance, longer duration of diabetes, and use of insulin pump (P < 0.01 all factors). CGM use was associated with lower HbA1c in children (8.3% vs. 8.6%, P < 0.001) and adults (7.7% vs. 7.9%, P < 0.001). In adults, more frequent use of CGM (≥6 days/week) was associated with lower mean HbA1c. Only 27% of users downloaded data from their device at least once per month, and ≤15% of users reported downloading their device at least weekly. Among participants who used CGM at baseline, 41% had discontinued within 1 year. CONCLUSIONS: CGM use is uncommon but associated with lower HbA1c in some age-groups, especially when used more frequently. Factors associated with discontinuation and infrequent use of retrospective analysis of CGM data should be considered in developing next-generation devices and education on CGM use.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Such phenomena question the accuracy and credibility of CGM and make patients less reactive to alarms and less willing to retain them activated or even continue to use CGM [ 43 , 55 ].”
Citations
Cites
Standards of Medical Care in Diabetes
Power, D. (2006) · Diabetes Care · doi:10.2337/diacare.29.02.06.dc05-1593 · Cited by 8,673
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
Continuous glucose monitoring and intensive treatment of type 1 diabetes
(2008) · New England Journal of Medicine · doi:10.1056/nejmoa0805017 · Cited by 1,559
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Pickup, J. C., Freeman, S. C., & Sutton, A. J. (2011) · BMJ · doi:10.1136/bmj.d3805 · Cited by 541 · cited 1×
“occasional) use of CGM is associated with better glycemic control, as measured by HbA1c (5,8), leading to a practice guideline recommending CGM for adults who are able to use it at least 6 days a week (9).”
Yeh, H.-C., Brown, T. T., Maruthur, N., Ranasinghe, P., Berger, Z., Suh, Y. D., Wilson, L. M., Haberl, E. B., Brick, J., Bass, E. B., et al. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-157-5-201209040-00508 · Cited by 493
Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes
Battelino, T., Phillip, M., Bratina, N., Nimri, R., Oskarsson, P., & Bolinder, J. (2011) · Diabetes Care · doi:10.2337/dc10-1989 · Cited by 490
The T1D exchange clinic registry
Beck, R. W., Tamborlane, W. V., Bergenstal, R. M., Miller, K. M., DuBose, S. N., Hall, C. A., & for the T1D Exchange Clinic Network (2012) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2012-1561 · Cited by 456
Self-citationThe effect of continuous glucose monitoring in well-controlled type 1 diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0108 · Cited by 399
Effectiveness of Continuous Glucose Monitoring in a Clinical Care Environment
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc09-1502 · Cited by 313
Continuous glucose monitoring systems for type 1 diabetes mellitus
Langendam, M., Luijf, Y. M., Hooft, L., DeVries, J. H., Mudde, A. H., & Scholten, R. J. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd008101.pub2 · Cited by 262
Factors Predictive of Use and of Benefit From Continuous Glucose Monitoring in Type 1 Diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2009) · Diabetes Care · doi:10.2337/dc09-0889 · Cited by 249
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
Mauras, N., Beck, R., Xing, D., Ruedy, K., Buckingham, B., Tansey, M., White, N. H., Weinzimer, S. A., Tamborlane, W., Kollman, C., et al. (2012) · Diabetes Care · doi:10.2337/dc11-1746 · Cited by 204
Self-citationUse of continuous glucose monitoring in children and adolescents *
Phillip, M., Danne, T., Shalitin, S., Buckingham, B. A., Laffel, L. M., Tamborlane, W. V., Battelino, T., & Participants, F. T. C. F. (2012) · Pediatric Diabetes · doi:10.1111/j.1399-5448.2011.00849.x · Cited by 122
Quality-of-Life Measures in Children and Adults With Type 1 Diabetes
Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group (2010) · Diabetes Care · doi:10.2337/dc10-0331 · Cited by 101
Continuous glucose monitoring in type 1 diabetes
Mauras, N., Fox, L. A., ENGLERT, K. A., & Beck, R. W. (2012) · Endocrine · doi:10.1007/s12020-012-9765-1 · Cited by 98
Self-citationThe Role of Reimbursement in the Adoption of Continuous Glucose Monitors
Bartelme, A., & Bridger, P. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300449 · Cited by 24 · cited 1×
“lack of insurance coverage for CGM has been suggested as a barrier to adoption (17), which may have contributed”
Background
Cited by
International consensus on use of continuous glucose monitoring
Danne, T., Nimri, R., Battelino, T., Bergenstal, R. M., Close, K. L., DeVries, J. H., Garg, S., Heinemann, L., Hirsch, I., Amiel, S. A., et al. (2017) · Diabetes Care · doi:10.2337/dc17-1600 · Cited by 2,069
Self-citationMiller, K. M., Foster, N. C., Beck, R. W., Bergenstal, R. M., DuBose, S. N., DiMeglio, L. A., Maahs, D. M., & Tamborlane, W. V. (2015) · Diabetes Care · doi:10.2337/dc15-0078 · Cited by 1,254
Self-citation6. Glycemic Targets: Standards of Medical Care in Diabetes—2018
American Diabetes Association (2018) · Diabetes Care · doi:10.2337/dc18-s006 · Cited by 762
Continuous Glucose Monitoring: A Review of Successes, Challenges, and Opportunities
Rodbard, D. (2016) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2015.0417 · Cited by 737
Martens, T., Beck, R. W., Bailey, R., Ruedy, K. J., Calhoun, P., Peters, A. L., Pop-Busui, R., Philis-Tsimikas, A., Bao, S., Umpierrez, G., et al. (2021) · JAMA · doi:10.1001/jama.2021.7444 · Cited by 543
Self-citation
Metadata
- Authors
- Wong, J. C., Foster, N. C., Maahs, D. M., Raghinaru, D., Bergenstal, R. M., Ahmann, A. J., Peters, A. L., Bode, B. W., Aleppo, G., Hirsch, I. B., Kleis, L., Chase, H. P., DuBose, S. N., Miller, K. M., Beck, R. W., Adi, S., & for the T1D Exchange Clinic Network
- Affiliations
- University of California, San Francisco (US)
- Jaeb Center for Health Research (US)
- University of Colorado Denver (US)
- Park Nicollet Health Services (US)
- Oregon Health & Science University (US)
- University of Southern California (US)
- Atlanta Diabetes Associates (US)
- Northwestern University (US)
- University of Washington (US)
- Spectrum Health (US)
- Corresponding author
- Miller, Kellee M.
- ORCID
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2014-09-10
- Volume
- 37
- Issue
- 10
- Pages
- 2702-2709
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC4392936
- OpenAlex
- W2136450455
- Semantic Scholar
- a3013d7ae63769a7d02f5f5ea02fd388f34dfe01
- Cited by
- 318
- References
- 19
- Citations by year
- 2026: 7 · 2025: 13 · 2024: 15 · 2023: 19 · 2022: 20 · 2021: 27 · 2020: 33 · 2019: 38 · 2018: 45 · 2017: 35 · 2016: 32 · 2015: 29 · 2014: 2
- FWCI
- 26.27
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Diabetes Care (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- Funders
- National Institutes of Health (5k12dk094726-05, UL1TR000142)
- National Institute of Diabetes and Digestive and Kidney Diseases (K12-DK094726)
- National Center for Advancing Translational Sciences
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Diabetes and associated disorders
- Keywords
- continuous glucose monitoring, type 1 diabetes, HbA1c, severe hypoglycemia, diabetic ketoacidosis, insulin pump, socioeconomic factors, age differences
- MeSH terms
- Adolescent, Adult, Blood Glucose, Child, Cross-Sectional Studies, Diabetes Mellitus, Type 1, Female, Glycated Hemoglobin, Humans, Hypoglycemia, Insulin, Insulin Infusion Systems, Male, Patient Education as Topic, Registries, Retrospective Studies, Risk Factors, Blood Glucose Self-Monitoring, Incidence, Diabetic Ketoacidosis, Monitoring, Ambulatory, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.