Do Sensor Glucose Levels Accurately Predict Plasma Glucose Concentrations During Hypoglycemia and Hyperinsulinemia?
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
OBJECTIVE—The MiniMed Continuous Glucose Monitoring System (CGMS) measures subcutaneous interstitial glucose levels that are calibrated against three or more fingerstick glucose levels daily. The objective of the present study was to examine whether the relationship between plasma and interstitial fluid glucose is altered by changes in plasma glucose and insulin levels and how such alterations might influence CGMS performance. RESEARCH DESIGN AND METHODS—Arterialized plasma glucose, sensor glucose, and interstitial fluid glucose were measured by microdialysis in 11 healthy subjects during a 1.0 mU · kg−1 · min−1 stepped euglycemic-hypoglycemic-hyperglycemic (plasma glucose ∼5, 3.1, and 8.6 mmol/l, respectively) insulin clamp that raised plasma insulin to ∼360–390 pmol/l. RESULTS—When the CGMS was calibrated versus plasma glucose levels before insulin infusion, basal sensor and plasma glucose were similar (5.0 ± 0.3 vs. 5.2 ± 0.3 mmol/l, respectively); dialysate glucose was 3.3 ± 0.9 mmol/l. During the hyperinsulinemic-euglycemia study (plasma glucose 4.9 ± 0.3 mmol/l), dialysate glucose fell by 30–35%, accompanied by a significant reduction in sensor glucose (to 3.7 ± 0.6 mmol/l; P < 0.001 vs. plasma). Subsequently, sensor levels remained lower than plasma values during mild hypoglycemia (2.5 ± 0.6 vs. 3.1 ± 0.3 mmol/l; P < 0.01) and during recovery from hypoglycemia (7.3 ± 1.2 vs. 8.6 ± 0.6; P < 0.01). However, when the CGMS was calibrated against plasma glucose levels before and during each step of the clamp, sensor glucose levels increased throughout the study and did not differ from plasma glucose values during hypoglycemia. CONCLUSIONS—Although hyperinsulinemia may contribute to modest discrepancies between plasma and sensor glucose levels, the CGMS is able to accurately track acute changes in plasma glucose when calibrated across a range of plasma glucose and insulin levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microdialysis—principles and applications for studies in animals and man
UNGERSTEDT, U. (1991) · Journal of Internal Medicine · doi:10.1111/j.1365-2796.1991.tb00459.x · Cited by 812 · cited 1×
“Microdialysis technique The microdialysis technique has been described in detail elsewhere (6).”
MethodBode, B. W., Gross, T. M., Thornton, K. R., & Mastrototaro, J. J. (1999) · Diabetes Research and Clinical Practice · doi:10.1016/s0168-8227(99)00113-8 · Cited by 232
Continuous Subcutaneous Glucose Monitoring in Children With Type 1 Diabetes
Chase, H. P., Kim, L. M., Owen, S. L., MacKenzie, T. A., Klingensmith, G. J., Murtfeldt, R., & Garg, S. K. (2001) · Pediatrics · doi:10.1542/peds.107.2.222 · Cited by 194
Aussedat, B., Dupire-Angel, M., Gifford, R., Klein, J. C., Wilson, G. S., & Reach, G. (2000) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2000.278.4.e716 · Cited by 186 · cited 1×
“Similar discrepancies between plasma and interstitial glucose concentrations during acute changes in plasma glucose and insulin levels have been reported in rats (11).”
BackgroundSaccà, L., Sherwin, R., Hendler, R., & Felig, P. (1979) · Journal of Clinical Investigation · doi:10.1172/jci109384 · Cited by 162
Self-citationBolincier, J., Ungerstedt, U., & Arner, P. (1992) · Diabetologia · doi:10.1007/bf00401374 · Cited by 142 · cited 1×
“We selected a well-established system that under the current conditions of use has been previously shown to result in a 90% recovery of interstitial glucose concentrations (7).”
MethodMaggs, D. G., Jacob, R., Rife, F., Caprio, S., Tamborlane, W., & Sherwin, R. S. (1997) · Diabetes · doi:10.2337/diab.46.1.70 · Cited by 52 · cited 3×
“The current finding that insulin-induced hypoglycemia increases the interstitial to plasma glucose concentration gradient in subcutaneous adipose tissue is consistent with the results of previous hypoglycemic clamp studies in healthy subjects from our laboratory, albeit with a different microdialysis system (5).”
ResultSelf-citationCohen, N., Rossetti, L., Shlimovich, P., Halberstam, M., Hu, M., & Shamoon, H. (1995) · Diabetes · doi:10.2337/diab.44.4.423 · Cited by 32
Davis, S. N., Shavers, C., Collins, L., Cherrington, A. D., Price, L., & Hedstrom, C. (1994) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1994.267.3.e402 · Cited by 31
Role of the Continuous Glucose Monitoring System in Pediatric Patients
KAUFMAN, F. R. (2000) · Diabetes Technology & Therapeutics · doi:10.1089/15209150050214122 · Cited by 29
Cited by
Monnier, L., Mas, E., Ginet, C., Michel, F., Villon, L., Cristol, J.-P., & Colette, C. (2006) · JAMA · doi:10.1001/jama.295.14.1681 · Cited by 2,444
Monnier, L., Lapinski, H., & Colette, C. (2003) · Diabetes Care · doi:10.2337/diacare.26.3.881 · Cited by 1,461
Babu, A. R., Herdegen, J., Fogelfeld, L., Shott, S., & Mazzone, T. (2005) · Archives of Internal Medicine · doi:10.1001/archinte.165.4.447 · Cited by 453
Association of Hypoglycemia and Cardiac Ischemia
Desouza, C., Salazar, H., Cheong, B., Murgo, J., & Fonseca, V. (2003) · Diabetes Care · doi:10.2337/diacare.26.5.1485 · Cited by 406
Toward Defining the Threshold Between Low and High Glucose Variability in Diabetes
Monnier, L., Colette, C., Wojtusciszyn, A., Dejager, S., Renard, E., Molinari, N., & Owens, D. R. (2017) · Diabetes Care · doi:10.2337/dc16-1769 · Cited by 390
The influence of insulin on circulating ghrelin
Flanagan, D. E., Evans, M. L., Monsod, T. P., Rife, F., Heptulla, R. A., Tamborlane, W. V., & Sherwin, R. S. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00569.2001 · Cited by 367
Self-citationA Novel Approach to Continuous Glucose Analysis Utilizing Glycemic Variation
McDonnell, C. M., Donath, S. M., Vidmar, S. I., Werther, G. A., & Cameron, F. J. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.253 · Cited by 358
Closed-loop insulin delivery—the path to physiological glucose control
Steil, G. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.08.011 · Cited by 313
Chico, A., Vidal-Ríos, P., Subirà, M., & Novials, A. (2003) · Diabetes Care · doi:10.2337/diacare.26.4.1153 · Cited by 235
Real-Time Continuous Glucose Monitoring in Critically Ill Patients
Holzinger, U., Warszawska, J., Kitzberger, R., Wewalka, M., Miehsler, W., Herkner, H., & Madl, C. (2010) · Diabetes Care · doi:10.2337/dc09-1352 · Cited by 212
Continuous glucose monitoring: an Endocrine Society Clinical Practice Guideline
Klonoff, D. C., Buckingham, B., Christiansen, J. S., Montori, V. M., Tamborlane, W. V., Vigersky, R. A., & Wolpert, H. (2011) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2010-2756 · Cited by 211
Self-citationDelays in Minimally Invasive Continuous Glucose Monitoring Devices: A Review of Current Technology
Keenan, D. B., Mastrototaro, J. J., Voskanyan, G., & Steil, G. M. (2009) · Journal of Diabetes Science and Technology · doi:10.1177/193229680900300528 · Cited by 198
Insulin Pump Therapy With Automated Insulin Suspension in Response to Hypoglycemia
Choudhary, P., Shin, J., Wang, Y., Evans, M. L., Hammond, P. J., Kerr, D., Shaw, J. A. M., Pickup, J. C., & Amiel, S. A. (2011) · Diabetes Care · doi:10.2337/dc10-2411 · Cited by 175
Freckmann, G., Hagenlocher, S., Baumstark, A., Jendrike, N., Gillen, R. C., Rössner, K., & Haug, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100513 · Cited by 174
The Contribution of Glucose Variability to Asymptomatic Hypoglycemia in Persons with Type 2 Diabetes
Monnier, L., Wojtusciszyn, A., Colette, C., & Owens, D. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2011.0049 · Cited by 168
“16 As it has been demonstrated by Monsod et al. 17 that CGMS sensor readings remain 20% lower than venous plasma glucose concentrations during mild hypoglycemia, we considered that a plasma glucose concentration of 3.9mmol/L in venous plasma samples corresponds to a subcutaneous value of 3.1mmol/L…”
Rebrin, K., Sheppard, N. F., & Steil, G. M. (2010) · Journal of Diabetes Science and Technology · doi:10.1177/193229681000400507 · Cited by 152
Chetty, V. T., Almulla, A., Odueyungbo, A., & Thabane, L. (2008) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2008.02.014 · Cited by 85
Validation of the continuous glucose monitoring sensor in preterm infants
Beardsall, K., Vanhaesebrouck, S., Ogilvy-Stuart, A. L., Vanhole, C., vanWeissenbruch, M., Midgley, P., Thio, M., Cornette, L., Ossuetta, I., Palmer, C. R., et al. (2013) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/archdischild-2012-301661 · Cited by 82
Assessment of transcapillary glucose exchange in human skeletal muscle and adipose tissue
Regittnig, W., Ellmerer, M., Fauler, G., Sendlhofer, G., Trajanoski, Z., Leis, H.-J., Schaupp, L., Wach, P., & Pieber, T. R. (2003) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00351.2002 · Cited by 41
Continuous glucose monitoring for hypoglycaemia in children: perspectives in 2020
Worth, C., Dunne, M., Ghosh, A., Harper, S., & Banerjee, I. (2020) · Pediatric Diabetes · doi:10.1111/pedi.13029 · Cited by 37
“between recorded ISF glucose and plasma glucose in healthy volunteers and therefore further worsens the accuracy of hypoglycaemiadetection.(22) The mechanism underlying this is has been suggested to be related to enhanced uptake of interstitial glucose by adipocytes that is not fully compensated for by increased deliv…”
BackgroundInfluentialSchechter, A., Eyal, O., Zuckerman-Levin, N., Amihai-Ben-Yaacov, V., Weintrob, N., & Shehadeh, N. (2012) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2012.0002 · Cited by 12
Metadata
- Authors
- Monsod, T. P., Flanagan, D. E., Rife, F., Saenz, R., Caprio, S., Sherwin, R. S., & Tamborlane, W. V.
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2002-05-01
- Volume
- 25
- Issue
- 5
- Pages
- 889-893
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- OpenAlex
- W2109942079
- Cited by
- 173
- References
- 10
- FWCI
- 8.88
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.