Real-time control of a prosthetic hand using human electrocorticography signals: Technical note
The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index.
Abstract
Object: A brain-machine interface (BMI) offers patients with severe motor disabilities greater independence by controlling external devices such as prosthetic arms. Among the available signal sources for the BMI, electrocorticography (ECoG) provides a clinically feasible signal with long-term stability and low clinical risk. Although ECoG signals have been used to infer arm movements, no study has examined its use to control a prosthetic arm in real time. The authors present an integrated BMI system for the control of a prosthetic hand using ECoG signals in a patient who had suffered a stroke. This system used the power modulations of the ECoG signal that are characteristic during movements of the patient's hand and enabled control of the prosthetic hand with movements that mimicked the patient's hand movements. Methods: A poststroke patient with subdural electrodes placed over his sensorimotor cortex performed 3 types of simple hand movements following a sound cue (calibration period). Time-frequency analysis was performed with the ECoG signals to select 3 frequency bands (1–8, 25–40, and 80–150 Hz) that revealed characteristic power modulation during the movements. Using these selected features, 2 classifiers (decoders) were trained to predict the movement state—that is, whether the patient was moving his hand or not—and the movement type based on a linear support vector machine. The decoding accuracy was compared among the 3 frequency bands to identify the most informative features. With the trained decoders, novel ECoG signals were decoded online while the patient performed the same task without cues (free-run period). According to the results of the real-time decoding, the prosthetic hand mimicked the patient's hand movements. Results: Offline cross-validation analysis of the ECoG data measured during the calibration period revealed that the state and movement type of the patient's hand were predicted with an accuracy of 79.6% (chance 50%) and 68.3% (chance 33.3%), respectively. Using the trained decoders, the onset of the hand movement was detected within 0.37 ± 0.29 seconds of the actual movement. At the detected onset timing, the type of movement was inferred with an accuracy of 69.2%. In the free-run period, the patient's hand movements were faithfully mimicked by the prosthetic hand in real time. Conclusions: The present integrated BMI system successfully decoded the hand movements of a poststroke patient and controlled a prosthetic hand in real time. This success paves the way for the restoration of the patient's motor function using a prosthetic arm controlled by a BMI using ECoG signals.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [274]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [150]
Citations
Cites
Wu, Y. (1999) · Technometrics · doi:10.1080/00401706.1999.10485951 · Cited by 27,221
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
Decoding the visual and subjective contents of the human brain
Kamitani, Y., & Tong, F. (2005) · Nature Neuroscience · doi:10.1038/nn1444 · Cited by 1,829
Self-citationCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Cited by
Items 101–200 of 208
Hashimoto, H., Takahashi, K., Kameda, S., Yoshida, F., Maezawa, H., Oshino, S., Tani, N., Khoo, H. M., Yanagisawa, T., Yoshimine, T., et al. (2021) · iScience · doi:10.1016/j.isci.2021.102786 · Cited by 12
“High γ activities with reductions in β power were also induced by hand movements (Yanagisawa et al., 2011).”
BackgroundSelf-citationThomas, T. M., Nickl, R. W., Thompson, M. C., Candrea, D. N., Fifer, M. S., McMullen, D. P., Osborn, L. E., Pohlmeyer, E. A., Anaya, M. A., Anderson, W. S., et al. (2020) · medRxiv · doi:10.1101/2020.06.02.20116913 · Cited by 17
“…Ajiboye et al., 2017; Bouton et al., 2016; Colachis et al., 2018; Collinger et al., 2013; Hochberg et al., 2012; Wang et al., 2013; Wodlinger et al., 2015; Yanagisawa et al., 2011, 2012), much less is known about the degree of bimanual control possible and how it can be affected by task complexity.”
BackgroundEEG-based Brain Computer Interface Prosthetic Hand using Raspberry Pi 4
Ali, H. A., Popescu, D., Hadăr, A., Vasilăţeanu, A., Popa, R. C., Goga, N., & Hussam, H. A. D. Q. (2021) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2021.0120905 · Cited by 12
“Among these, the electroencephalography (EEG) method offers an appropriate signal along with stability and non-clinical risks [4].”
BackgroundMethodTomonaga, K., Wakamizu, S., & Kobayashi, J. (2015) · International Conference on Control, Automation and Systems (ICCAS) · doi:10.1109/iccas.2015.7364652 · Cited by 12
“The BMI is anticipated to appreciably improve the usability of prosthetic limbs for handicapped patients [3] and to bring to realization practicable robots that are controlled by human imagination [4-7].”
BackgroundSomatosensation Evoked by Cortical Surface Stimulation of the Human Primary Somatosensory Cortex
Kirin, S. C., Yanagisawa, T., Oshino, S., Edakawa, K., Tanaka, M., Kishima, H., & Nishimura, Y. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.01019 · Cited by 12
“13:1019. doi: 10.3389/fnins.2019.01019 Somatosensation Evoked by Cortical Surface Stimulation of the Human Primary Somatosensory Cortex St. Clair Kirin1,2, Takufumi Yanagisawa3,4,5* , Satoru Oshino3, Kohtaroh Edakawa3, Masataka Tanaka3, Haruhiko Kishima3 and Yukio Nishimura1,2,6* 1 Department of Developmental Physiolo…”
BackgroundInfluentialSelf-citationCharacterization of High-Gamma Activity in Electrocorticographic Signals
Gruenwald, J., Sieghartsleitner, S., Kapeller, C., Scharinger, J., Kamada, K., Brunner, P., & Guger, C. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1206120 · Cited by 13
“These qualities make HGA highly suitable for invasive brain-computer interface (BCI) applications, such as motor rehabilitation that provide prosthetic limb control and movement restoration (Leuthardt et al., 2004; Shenoy et al., 2008; Kubanek et al., 2009; Yanagisawa et al., 2011; Pistohl et al., 2012; Jiang et al.,…”
MEG–BMI to Control Phantom Limb Pain
Yanagisawa, T., Fukuma, R., Seymour, B., Hosomi, K., Kishima, H., Shimizu, T., Yokoi, H., Hirata, M., Yoshimine, T., Kamitani, Y., et al. (2018) · Neurologia medico-chirurgica · doi:10.2176/nmc.st.2018-0099 · Cited by 11
Self-citationA novel classification method with unlearned-class detection based on a gaussian mixture model
Shima, K., & Aoki, T. (2014) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2014.6974510 · Cited by 11
“Support vector machines (SVMs) have also been widely discussed in recent years for their nonlinear classification capabilities, which are strongly demonstrated through use for classification in various applications [7], [9].”
BackgroundA comprehensive study of EEG-based control of artificial arms
Satam, I. A. (2023) · Vojnotehnicki glasnik · doi:10.5937/vojtehg71-41366 · Cited by 10
Lower Extremity Allotransplantation: Are We Ready for Prime Time?
Swanson, E. W., Cheng, H.-T., Lough, D., Lee, W. P. A., Shores, J. T., & Brandacher, G. (2015) · Vascularized Composite Allotransplantation · doi:10.1080/23723505.2015.1123798 · Cited by 13
On-chip implementation of ECoG signal data decoding in brain-computer interface
Agrawal, M., Vidyashankar, S., & Huang, K. (2016) · IEEE International Mixed-Signals, Sensors and Systems Test Workshop (IMS3TW) · doi:10.1109/ims3tw.2016.7524225 · Cited by 10
Predicting Wrist Movement Trajectory from Ipsilesional ECoG in Chronic Stroke Patients
Spüler, M., Rosenstiel, W., & Bogdan, M. (2014) · International Congress on Neurotechnology, Electronics and Informatics · doi:10.5220/0005165200380045 · Cited by 10
Electrocorticographic Brain–Machine Interfaces for Motor and Communication Control
Hirata, M., & Yoshimine, T. (2014) · Springer eBooks · doi:10.1007/978-4-431-55037-2_5 · Cited by 9
Self-citationNeurosurgery and the dawning age of Brain-Machine Interfaces
Chang, E., Rowland, N. C., & Breshears, J. D. (2013) · Surgical Neurology International · doi:10.4103/2152-7806.109182 · Cited by 11
“constructed a decoding algorithm that allowed accurate mimicking by a robotic hand of imagined finger movements in a patient with stroke.[24] Notably, this capability has also been achieved by Figure 1: Schematic of a hypothetical closed-loop brain–machine interface system including an implantable electrocorticographi…”
MethodReal-Time MEG-Based Brain-Geminoid Control Using Single-trial SVM Classification
Belkacem, A. N., Ishiguro, H., Nishio, S., Hirata, M., & Suzuki, T. (2018) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm.2018.8610776 · Cited by 9
“All recent studies have focused on classification of unimanual movements to control come external devices or communicate with the environment by proposing some practical real-time BCI applications [10-13].”
BackgroundSelf-citationDesign aspects of a low-cost prosthetic arm for people with severe movement disabilities
Kocejko, T., Weglerski, R., Zubowicz, T., Rumiński, J., Wtorek, J., & Armiński, K. (2020) · Conference on Human System Interactions · doi:10.1109/hsi49210.2020.9142647 · Cited by 9
“Therefore the researchers are also trying to exploit the possibilities of using EEG [13], [14], ECoG [15] or even hybrid interfaces [16] for controlling the prosthetic hand or even whole arm.”
BackgroundNeuroprosthesis Devices Based on Micro- and Nanosensors: A Systematic Review
Gutiérrez-Martínez, J., Toledo-Peral, C. L., Mercado-Gutierrez, J. A., Vera, A., & Leija, L. (2020) · Journal of Sensors · doi:10.1155/2020/8865889 · Cited by 11
“One paper published results of realtime control for a prosthetic limb [112].”
BackgroundComparing Methods for Decoding Movement Trajectory from ECoG in Chronic Stroke Patients
Spüler, M., Grimm, F., Gharabaghi, A., Bogdan, M., & Rosenstiel, W. (2015) · Biosystems & biorobotics · doi:10.1007/978-3-319-26242-0_9 · Cited by 10
“While BCIs might help those patients as an assistive device to compensate the missing motor function [3], they can also be used as tool for rehabilitation.”
Yoo, P. E., Oxley, T. J., John, S. E., Opie, N. L., Ordidge, R. J., O'Brien, T. J., Hagan, M. A., Wong, Y. T., & Moffat, B. A. (2018) · Scientific Reports · doi:10.1038/s41598-018-33839-4 · Cited by 8
Using a BCI Prosthetic Hand to Control Phantom Limb Pain
Yanagisawa, T., Fukuma, R., Seymour, B., Hosomi, K., Kishima, H., Shimizu, T., Yokoi, H., Hirata, M., Yoshimine, T., Kamitani, Y., et al. (2019) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-030-05668-1_4 · Cited by 9
Self-citationA World Update of Progress in Lower Extremity Transplantation: What’s Hot and What’s Not
Kodali, N. A., Ramu, J., Sazoglu, B., Demir, Z., Dirican, O. F., Zor, F., Külahçı, Y., & Gorantla, V. S. (2024) · Annals of Plastic Surgery · doi:10.1097/sap.0000000000004035 · Cited by 11
“47 – 52 Considering the constraints associated with existing and evolving prosthetics, LEToffers distinctive advantages.”
BackgroundMoustakas, N., Athanasiou, A., Kartsidis, P. E., Bamidis, P. D., & Astaras, A. (2013) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-00846-2_16 · Cited by 8
Degenhart, A. D., Collinger, J. L., Vinjamuri, R. K., Kelly, J. W., Tyler‐Kabara, E. C., & Wang, W. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091431 · Cited by 11
“3% three-class classification accuracy) [14], in spite of the confounding factor of applied force, it may be possible to increase classification accuracy through improvements in task design.”
BackgroundKapeller, C., Gergondet, P., Kamada, K., Ogawa, H., Takeuchi, F., Ortner, R., Prückl, R., Kheddar, A., Scharinger, J., & Guger, C. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318720 · Cited by 9
“This independent BCI approach has been used to control robotic arms [9], [12], [14] or avatars in virtual environments [15].”
BackgroundMethodBrain-Computer Interface for children: state-of-the-art and challenges
Beraldo, G., Suppiej, A., Forest, C., Tonin, L., & Menegatti, E. (2020) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc42975.2020.9283485 · Cited by 8
“Over the last decade, several studies have shown how BCIs can be successfully integrated with assistive technologies such as prosthetic arms [8], [9], wheelchairs [10], [11], mobile robots [12], [13], exoskeletons [14], [15], robotic arms [16], [17].”
BackgroundAndersson, P. U., Ramsey, N. F., Viergever, M. A., & Pluim, J. P. W. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.05.009 · Cited by 7
Categorical discrimination of human body parts by magnetoencephalography
Nakamura, M., Yanagisawa, T., Okamura, Y., Fukuma, R., Hirata, M., Araki, T., Kamitani, Y., & Yorifuji, S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00609 · Cited by 8
“Notably, being able to decode categorical information, as in our study, is an important step in the context of brain– machine interface (BMI) research (Yanagisawa et al., 2011; Sugata et al., 2012).”
BackgroundSelf-citationOhmae, S., Takahashi, T., Lu, X., Nishimori, Y., Kodaka, Y., Takashima, I., & Kitazawa, S. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036014 · Cited by 9
“In a more recent study, Yanagisawa, Hirata, Saitoh, Goto, Kishima, Fukuma, Yokoi, Kamitani and Yoshimine [14] developed a decoder that predicted whether a hand was in a state of discrete movement based on 64-channel electrocorticography signals, and they succeeded in detecting 61% of the movement onsets within 1 s of…”
BackgroundMethodSuper multi-channel recording systems with UWB wireless transmitter for BMI
Suzuki, T., Ando, H., Yoshida, T., Sawahata, H., Kawasaki, K., Hasegawa, I., Matsushita, K., Hirata, M., Yoshimine, T., & Takizawa, K. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944799 · Cited by 7
Self-citationPhase-amplitude coupling-based adaptive filters for neural signal decoding
Li, J., Qi, Y., & Pan, G. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1153568 · Cited by 8
“These decoders usually use Fourier transform or wavelet transforms to extract the power of certain frequency bands as the features and evaluate the features in a task-driven manner to select the effective narrow bands (Yanagisawa et al., 2011; Chestek et al., 2013; Bleichner et al., 2016; Branco et al., 2017; Li et al…”
MethodInvasive Brain Machine Interface System
Jin, Y., Chen, J., Zhang, S., Chen, W., & Zheng, X. (2019) · Advances in experimental medicine and biology · doi:10.1007/978-981-13-2050-7_3 · Cited by 7
Ali, H. A., Goga, N., Vasilăţeanu, A., Ali, L. A., Abd-almuhsen, G. S., & Naji, H. K. (2021) · International Conference on Electronics, Computers and Artificial Intelligence (ECAI) · doi:10.1109/ecai52376.2021.9515168 · Cited by 6
An open-source and cross-platform framework for Brain Computer Interface-guided robotic arm control
Kubben, P., & Pouratian, N. (2012) · Surgical Neurology International · doi:10.4103/2152-7806.104743 · Cited by 8
“13, 15-17 15-17, 20 , 21] Although”
Opie, N. L., John, S. E., Rind, G. S., Ronayne, S. M., May, C. N., Grayden, D. B., & Oxley, T. J. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512385 · Cited by 8
What Is the Contribution of iEEG as Compared to Other Methods to Cognitive Neuroscience?
Liu, J., & Xue, G. (2023) · Studies in neuroscience, psychology and behavioral economics · doi:10.1007/978-3-031-20910-9_8 · Cited by 6
Kimizuka, S., Tanaka, Y., Togo, S., Jiang, Y., & Yokoi, H. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.542033 · Cited by 5
“Other related studies used electrocorticogram signals to control the robot arm like a shoulder disarticulation prosthesis (Yanagisawa et al., 2011; Leigh et al., 2012).”
BackgroundSelf-citationA Flexible Meal Aid Robotic Arm System Based on SSVEP
Chen, Z., Li, J., Liu, Y., & Tang, P. (2020) · IEEE International Conference on Progress in Informatics and Computing · doi:10.1109/pic50277.2020.9350785 · Cited by 5
Decoding of Hand Gestures from Electrocorticography with LSTM Based Deep Neural Network
Pradeepkumar, J., Anandakumar, M., Kugathasan, V., Lalitharatne, T. D., Silva, A. C. D., & Kappel, S. L. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630958 · Cited by 5
Hotson, G., Fifer, M. S., Acharya, S., Anderson, W. S., Thakor, N. V., & Crone, N. E. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346869 · Cited by 5
Jin, Y., Lu, M., Wang, X., Zhang, S., Zhu, J., & Zheng, X. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591005 · Cited by 5
“The researchers of Osaka University Medical School successfully used the human ECoG signals to control a prosthetic hand in real-time[6].”
MethodHirata, M., Matsushita, K., Yanagisawa, T., Goto, T., Morris, S., Yokoi, H., Suzuki, T. J., Yoshida, T., Satō, F., Sakura, O., et al. (2012) · Advanced Robotics · doi:10.1163/156855311x614581 · Cited by 4
Self-citationWatanabe, H., Sakatani, T., Suzuki, T., Sato, M.-A., Nishimura, Y., Nambu, A., Kawato, M., & Isa, T. (2014) · Neuroscience Research · doi:10.1016/j.neures.2014.06.010 · Cited by 4
“…(BMIs), because they have been shown to provide rich information about motor outputs in both human and non-human primate (Waldert et al., 2009; Yanagisawa et al., 2011, Abbreviations: ECoG, electrocorticogram; LFP, local field potential; CSD, current source density; BMI, brain–machine…”
Tagliabue, M., Francis, N., Hao, Y., Duret, M., Brochier, T. G., Riehle, A., Maier, M. A., & Eskiizmirliler, S. (2015) · International Conference on Advanced Robotics (ICAR) · doi:10.1109/icar.2015.7251473 · Cited by 4
Gharabaghi, A. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-802452-2.00016-0 · Cited by 4
Neuromagnetic Geminoid Control by BCI Based on Four Bilateral Hand Movements
Belkacem, A. N., Nishio, S., Suzuki, T., Ishiguro, H., & Hirata, M. (2018) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2018.00099 · Cited by 4
“All previous studies have used decoding of unilateral movements to control external devices to achieve a practical real-time BCI control [10-13].”
BackgroundSelf-citationDirected causality of the human electrocorticogram during dexterous movement
Benz, H. L., Collard, M., Tsimpouris, C., Acharya, S., Crone, N. E., Thakor, N. V., & Bezerianos, A. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346317 · Cited by 4
Artificial nerve systems for use in bio-interactive prostheses
Kim, C. H., Seo, D., Lee, Y., & Lee, T. (2025) · Nature Reviews Electrical Engineering · doi:10.1038/s44287-025-00197-z · Cited by 5
“EMG signals 31,32 originate from the electrical activity of muscle and provide direct relationships with motor intentions, whereas brain signals (detected by EEG 33–35 or electrocorticography 36,37 ) and peripheral nerve signals (detected by”
Irastorza-Landa, N., Sarasola-Sanz, A., Bibián, C., Ray, A. M., Insausti-Delgado, A., Helmhold, F., Mahmoud, W. J., Ortego-Isasa, I., López‐Larraz, E., & Ramos‐Murguialday, A. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_120 · Cited by 3
How Does Artificial Intelligence Contribute to iEEG Research?
Berezutskaya, J., Saive, A.-L., Jerbi, K., & van Gerven, M. A. J. (2023) · Studies in neuroscience, psychology and behavioral economics · doi:10.1007/978-3-031-20910-9_47 · Cited by 5
Patient-specific contour-fitting sheet electrodes for electrocorticographic brain machine interfaces
Hirata, M., Morris, S., Sugata, H., Matsushita, K., Yanagisawa, T., Kishima, H., & Yoshimine, T. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944798 · Cited by 3
Self-citationElectrocorticogram based brain–computer interfaces
Guger, C., Kapeller, C., Ogawa, H., Prückl, R., Grünwald, J., & Kamada, K. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812892-3.00009-1 · Cited by 3
Cooperative Control of Multiple CAs
Nagai, T., Nakamura, T., Sugiura, K., Taniguchi, T., Suzuki, Y., & Hirata, M. (2024) · Springer eBooks · doi:10.1007/978-981-97-3752-9_5 · Cited by 2
Self-citationECoG Dual Context Network for Brain Machine Interfaces
Nagashima, S., Kaneda, K., Wada, Y., Iida, T., Taguchi, M., Hirata, M., & Sugiura, K. (2025) · IEEE Access · doi:10.1109/access.2025.3577407 · Cited by 5
“This means that these electrodes are neurophysiologically relevant for classification of ECoG signals recorded during movement attempts [73], [74].”
Self-citationAl-Quraishi, M. S., Tahir, H., Ferik, S. E., & Ali, S. S. A. (2026) · Results in Engineering · doi:10.1016/j.rineng.2026.110833 · Cited by 2
Design and implementation of a human ECoG simulator for testing brain-machine interfaces
Fifer, M. S., Milsap, G., Greenwald, E., McMullen, D. P., Anderson, W. S., Thakor, N. V., Crone, N. E., & Vinjamuri, R. K. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696182 · Cited by 2
“HE construction of closed-loop motor brain-machine interfaces (BMIs) that rely on human electrocorticography (ECoG) as a viable source of control signals is becoming increasingly prevalent due to the high spatial and temporal resolution offered by ECoG [1-7].”
BackgroundBrain Machine-Interfaces for Motor and Communication Control
Hirata, M. (2016) · Springer eBooks · doi:10.1007/978-4-431-54598-9_11 · Cited by 3
Self-citationMotor BMIs Have Entered the Clinical Realm
Caldwell, D. J., Herron, J. A., Ko, A. L., & Ojemann, J. G. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_108-1 · Cited by 1
Hirata, M. (2019) · Springer eBooks · doi:10.1007/978-3-030-00087-5_22 · Cited by 2
Self-citationIrastorza-Landa, N., Sarasola-Sanz, A., Bibián, C., Ray, A. M., Insausti-Delgado, A., Helmhold, F., Mahmoud, W. J., Ortego-Isasa, I., López‐Larraz, E., & Ramos‐Murguialday, A. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_120-1 · Cited by 2
Wankhade, M. M., & Chorage, S. S. (2024) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237224500194 · Cited by 2
Neural network based algorithm for hand gesture detection in a low-cost microprocessor applications
Kocejko, T., Brzezinski, F., Poliński, A., Rumiński, J., & Wtorek, J. (2020) · Conference on Human System Interactions · doi:10.1109/hsi49210.2020.9142672 · Cited by 2
“Therefore the researchers are also try to exploit the possibilities of using EEG [14], [15], ECoG [16] or even hybrid interfaces [17] for controlling the prosthetic hand or even whole arm.”
BackgroundNoninvasive brain–computer interfaces using fNIRS, EEG, and hybrid EEG-fNIRS
Nazeer, H., Naseer, N., Khan, M. J., & Hong, K. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95439-6.00003-x · Cited by 1
Neural signal analysis in chronic stroke: advancing intracortical brain-computer interface design
Shawki, N., Napoli, A., Vargas-Irwin, C. E., Thompson, C. K., Donoghue, J. P., & Serruya, M. D. (2025) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2025.1544397 · Cited by 4
Research on Wireless Transmission of ECoG Signals Based on Backscatter Communication
Meng, Z., & Liao, W. (2025) · IEEJ Transactions on Electrical and Electronic Engineering · doi:10.1002/tee.70201 · Cited by 1
Meyer, L. M., & Zamani, M. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae6dfd · Cited by 1
Ishida, G., Takubo, T., & Ueno, A. (2013) · IEEE/SICE International Symposium on System Integration (SII) · doi:10.1109/sii.2013.6776742 · Cited by 1
Hirata, M. (2014) · Springer eBooks · doi:10.1007/978-3-642-33045-2_22 · Cited by 1
Self-citationFive-fingered Myoelectric Hand for Realizing a Precise Human-hand Function
Kato, R., & Yokoi, H. (2014) · Journal of the Japan Society for Precision Engineering · doi:10.2493/jjspe.80.259 · Cited by 1
Self-citationA Control Strategy for Prosthetic Hand Based on Attention Concentration and EMG
Wu, C., Song, A., & Peng, J. (2015) · Lecture notes in computer science · doi:10.1007/978-3-319-22879-2_28 · Cited by 1
Hirata, M., Yanagisawa, T., Matsushita, K., Sugata, H., Kamitani, Y., Suzuki, T., Yokoi, H., Goto, T., Morris, S., Saitoh, Y., et al. (2012) · Advances in bioinformatics and biomedical engineering book series · doi:10.4018/978-1-4666-2196-1.ch036 · Cited by 1
Self-citationThe Brain-Machine Interface (BMI) : A Novel Neurotechnology
Yoshimine, T., Hirata, M., Yanagisawa, T., & Kishima, H. (2016) · Japanese Journal of Neurosurgery · doi:10.7887/jcns.25.964 · Cited by 1
Self-citationBrain-Machine Interface Development for Finger Movement Control
Lal, T. M., Hotson, G., Fifer, M. S., McMullen, D. P., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R. S., Anderson, W. S., Thakor, N. V., et al. (2017) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-319-57132-4_4 · Cited by 1
Electrocorticographic Control of a Prosthetic Hand in Paralyzed Patients
Yanagisawa, T., Hirata, M., Saitoh, Y., Kishima, H., Matsushita, K., Goto, T., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2014) · Biosystems & biorobotics · doi:10.1007/978-3-642-54707-2_10 · Cited by 1
Self-citationDecoding movement information from cortical activity for invasive BMIs
Kim, M., & Kim, S.-P. (2018) · International Winter Conference on Brain-Computer Interface (BCI) · doi:10.1109/iww-bci.2018.8311504 · Cited by 1
Towards closed-loop stimulation for stroke rehabilitation
Walter, A. (2013)
Communication with ALS patients: Neurosurgical approach
Yoshimine, T., Yanagisawa, T., Sawada, J., Hazama, T., Mochizuki, H., & Hirata, M. (2013) · Rinsho Shinkeigaku · doi:10.5692/clinicalneurol.53.1405
Self-citationNear Infrared Spectroscopy (NIRS) in Rehabilitation Medicine
Mihara, M. (2016) · リハビリテーション医学 : 日本リハビリテーション医学会誌 · doi:10.2490/jjrmc.53.471
Agrawal, M., Vidyashankar, S., & Huang, K. (2017) · InTech eBooks · doi:10.5772/66149
Brain-Machine Interfaces : Principles and Clinical Application
Hirata, M., Yanagisawa, T., Matsushita, K., Sugata, H., Morris, S., Kamitani, Y., Suzuki, T., Yoshida, T., Satō, F., Moriwaki, T., et al. (2013) · Japanese Journal of Neurosurgery · doi:10.7887/jcns.22.192
Self-citationブレイン・マシン・インターフェース(BMI)とリハビリテーション(特別講演III)
平田, 雅. (2012) · 理学療法学 · doi:10.15063/rigaku.kj00008521541
Is Lower Extremity Transplantation a Superior Alternative to Prostheses? No—At Least Not Yet
Grimm, P. D., Tintle, S. M., Potter, B. K., & Elster, E. A. (2018) · Current Transplantation Reports · doi:10.1007/s40472-018-0217-6
Clinical Application of Implantable Brain Machine Interfaces
Hirata, M., Kameda, S., Palmer, J. A., Ando, H., Suzuki, T., Jiang, Y., Yokoi, H., & Koike, Y. (2018) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2018.00031
Self-citationNeural decoding by invasive electrocorticography
Li, Y., Qi, Y., Pan, G., & Zhang, S. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814942-3.00002-7
Gutiérrez-Cárdenas, J. M. (2019) · Universidad de Lima · doi:10.26439/ulima.tesis/9320 · Cited by 1
Hirata, M. (2020) · リハビリテーション医学 : 日本リハビリテーション医学会誌 · doi:10.2490/jjrmc.57.425
Self-citation(2018) · Journal of the Society of Biomechanisms · doi:10.3951/sobim.42.2_89
Jiang, T., Asman, P., Pellizzer, G., Bastos, D. C. A., Bhavsar, S., Tummala, S., Prabhu, S. S., & Ince, N. F. (2021) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-030-60460-8_8
The Analysis and Decoding of Swallowing-related Neural Activities Using Intracranial Electrodes
Hashimoto, H., Kameda, S., Maezawa, H., Oshino, S., Tani, N., Khoo, H. M., Yanagisawa, T., Yoshimine, T., Kishima, H., & Hirata, M. (2020) · Koutou (THE LARYNX JAPAN) · doi:10.5426/larynx.32.165
Self-citation脳神経外科領域におけるclinical toolおよびresearch topicとしての頭皮, 皮質脳波の現状
健寿, 前., 基希, 稲., 橋本, 聡., & 一秀, 清. (2021) · 臨床神経生理学 · doi:10.11422/jscn.49.145
Azeglio, S., Bernardo, A. D., Penna, G., Pittatore, F., Poetto, S., Gruenwald, J., Kapeller, C., Kamada, K., & Guger, C. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2110.04653 · Cited by 1
“The standard technique used to face such a classification problem is a combination of common spatial patterns (CSP) and multi-class linear discriminant analysis (LDA) [3], or multi-class support vector machine (SVM) [10],[11].”
MethodOsborn, L. E., Betthauser, J., & Thakor, N. V. (2019) · Wiley eBooks · doi:10.1002/047134608x.w1424.pub2 · Cited by 2
Hirata, M. (2019) · Springer eBooks · doi:10.1007/978-3-319-62657-4_22-1
Self-citationBrain-Machine Interface Using Brain Surface Electrodes
Hirata, M., Yanagisawa, T., Matsushita, K., Sugata, H., Kamitani, Y., Suzuki, T., Yokoi, H., Goto, T., Morris, S., Saitoh, Y., et al. (2013) · IGI Global eBooks · doi:10.4018/978-1-4666-4422-9.ch080
Self-citationBionic Human: A Review of Interface Modalities for Externally Powered Prosthetic Limbs
Mundkur, N. (2019) · McGill Science Undergraduate Research Journal · doi:10.26443/msurj.v14i1.53 · Cited by 1
Brain-Machine Interfaces for Upper and Lower Limb Prostheses
Brantley, J. A., Paek, A. Y., Steele, A. G., & Contreras-Vidal, J. L. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_35-2 · Cited by 3
Brain-Machine Interfaces for Upper and Lower Limb Prostheses
Brantley, J. A., Paek, A. Y., Steele, A. G., & Contreras-Vidal, J. L. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_35
Motor BMIs Have Entered the Clinical Realm
Caldwell, D. J., Herron, J. A., Ko, A. L., & Ojemann, J. G. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_108
Realizing Upper Extremity Bionic Limbs: Leveraging Neuroprosthetic Control Strategies
Kumar, N. G., Chestek, C. A., Cederna, P. S., & Kung, T. A. (2023) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000011183
“35,36”
Brain-Body Interfaces to Assist and Restore Motor Functions in People with Paralysis
Losanno, E., Badi, M., Roussinova, E., Bogaard, A. R., Delacombaz, M., Shokur, S., & Micera, S. (2023) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-031-49457-4_7
Metadata
- Authors
- Yanagisawa, T., Hirata, M., Saitoh, Y., Goto, T., Kishima, H., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T.
- Affiliations
- Advanced Telecommunications Research Institute International (JP)
- The University of Osaka (JP)
- The University of Tokyo (JP)
- Corresponding author
- Hirata, Masayuki
- ORCID
- Venue
- Journal of Neurosurgery
- Published
- 2011-06
- Volume
- 114
- Issue
- 6
- Pages
- 1715-1722
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W1545922961
- Cited by
- 208
- References
- 33
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 8 · 2023: 13 · 2022: 9 · 2021: 14 · 2020: 16 · 2019: 14 · 2018: 21 · 2017: 9 · 2016: 19 · 2015: 15 · 2014: 24 · 2013: 18 · 2012: 14
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of neurosurgery (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (22700435, 22390275, 23390347)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- electrocorticography, brain-computer interface, prosthetic hand control, stroke, motor recovery, real-time decoding, subdural electrodes, sensorimotor cortex, support vector machine, time-frequency analysis, frequency band selection, upper limb prosthesis
- MeSH terms
- Artificial Limbs, Electroencephalography, Hand, Humans, Male, Middle Aged, Motor Cortex, Movement, User-Computer Interface, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.