CoChat

Real-time control of a prosthetic hand using human electrocorticography signals: Technical note

The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index.

Abstract

Object: A brain-machine interface (BMI) offers patients with severe motor disabilities greater independence by controlling external devices such as prosthetic arms. Among the available signal sources for the BMI, electrocorticography (ECoG) provides a clinically feasible signal with long-term stability and low clinical risk. Although ECoG signals have been used to infer arm movements, no study has examined its use to control a prosthetic arm in real time. The authors present an integrated BMI system for the control of a prosthetic hand using ECoG signals in a patient who had suffered a stroke. This system used the power modulations of the ECoG signal that are characteristic during movements of the patient's hand and enabled control of the prosthetic hand with movements that mimicked the patient's hand movements. Methods: A poststroke patient with subdural electrodes placed over his sensorimotor cortex performed 3 types of simple hand movements following a sound cue (calibration period). Time-frequency analysis was performed with the ECoG signals to select 3 frequency bands (1–8, 25–40, and 80–150 Hz) that revealed characteristic power modulation during the movements. Using these selected features, 2 classifiers (decoders) were trained to predict the movement state—that is, whether the patient was moving his hand or not—and the movement type based on a linear support vector machine. The decoding accuracy was compared among the 3 frequency bands to identify the most informative features. With the trained decoders, novel ECoG signals were decoded online while the patient performed the same task without cues (free-run period). According to the results of the real-time decoding, the prosthetic hand mimicked the patient's hand movements. Results: Offline cross-validation analysis of the ECoG data measured during the calibration period revealed that the state and movement type of the patient's hand were predicted with an accuracy of 79.6% (chance 50%) and 68.3% (chance 33.3%), respectively. Using the trained decoders, the onset of the hand movement was detected within 0.37 ± 0.29 seconds of the actual movement. At the detected onset timing, the type of movement was inferred with an accuracy of 69.2%. In the free-run period, the patient's hand movements were faithfully mimicked by the prosthetic hand in real time. Conclusions: The present integrated BMI system successfully decoded the hand movements of a poststroke patient and controlled a prosthetic hand in real time. This success paves the way for the restoration of the patient's motor function using a prosthetic arm controlled by a BMI using ECoG signals.

Overview

Integrity signals

Registry

Crossref · 10.3171/2011.1.jns101421

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 208

Metadata

Authors
Yanagisawa, T., Hirata, M., Saitoh, Y., Goto, T., Kishima, H., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T.
Affiliations
  • Advanced Telecommunications Research Institute International (JP)
  • The University of Osaka (JP)
  • The University of Tokyo (JP)
Corresponding author
Hirata, Masayuki
Venue
Journal of Neurosurgery
Published
2011-06
Volume
114
Issue
6
Pages
1715-1722
ISSN
  • 0022-3085 (ISSN-L)
  • 1933-0693
OpenAlex
W1545922961
Cited by
208
References
33
Citations by year
2026: 3 · 2025: 7 · 2024: 8 · 2023: 13 · 2022: 9 · 2021: 14 · 2020: 16 · 2019: 14 · 2018: 21 · 2017: 9 · 2016: 19 · 2015: 15 · 2014: 24 · 2013: 18 · 2012: 14
FWCI
9.74
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of neurosurgery (publishedVersion)
  • PubMed (publishedVersion)
Funders
Japan Society for the Promotion of Science (22700435, 22390275, 23390347)
Topics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
electrocorticography, brain-computer interface, prosthetic hand control, stroke, motor recovery, real-time decoding, subdural electrodes, sensorimotor cortex, support vector machine, time-frequency analysis, frequency band selection, upper limb prosthesis
MeSH terms
Artificial Limbs, Electroencephalography, Hand, Humans, Male, Middle Aged, Motor Cortex, Movement, User-Computer Interface, Stroke

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.