Real-time control of a prosthetic hand using human electrocorticography signals: Technical note
The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index.
Abstract
Object: A brain-machine interface (BMI) offers patients with severe motor disabilities greater independence by controlling external devices such as prosthetic arms. Among the available signal sources for the BMI, electrocorticography (ECoG) provides a clinically feasible signal with long-term stability and low clinical risk. Although ECoG signals have been used to infer arm movements, no study has examined its use to control a prosthetic arm in real time. The authors present an integrated BMI system for the control of a prosthetic hand using ECoG signals in a patient who had suffered a stroke. This system used the power modulations of the ECoG signal that are characteristic during movements of the patient's hand and enabled control of the prosthetic hand with movements that mimicked the patient's hand movements. Methods: A poststroke patient with subdural electrodes placed over his sensorimotor cortex performed 3 types of simple hand movements following a sound cue (calibration period). Time-frequency analysis was performed with the ECoG signals to select 3 frequency bands (1–8, 25–40, and 80–150 Hz) that revealed characteristic power modulation during the movements. Using these selected features, 2 classifiers (decoders) were trained to predict the movement state—that is, whether the patient was moving his hand or not—and the movement type based on a linear support vector machine. The decoding accuracy was compared among the 3 frequency bands to identify the most informative features. With the trained decoders, novel ECoG signals were decoded online while the patient performed the same task without cues (free-run period). According to the results of the real-time decoding, the prosthetic hand mimicked the patient's hand movements. Results: Offline cross-validation analysis of the ECoG data measured during the calibration period revealed that the state and movement type of the patient's hand were predicted with an accuracy of 79.6% (chance 50%) and 68.3% (chance 33.3%), respectively. Using the trained decoders, the onset of the hand movement was detected within 0.37 ± 0.29 seconds of the actual movement. At the detected onset timing, the type of movement was inferred with an accuracy of 69.2%. In the free-run period, the patient's hand movements were faithfully mimicked by the prosthetic hand in real time. Conclusions: The present integrated BMI system successfully decoded the hand movements of a poststroke patient and controlled a prosthetic hand in real time. This success paves the way for the restoration of the patient's motor function using a prosthetic arm controlled by a BMI using ECoG signals.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Subcutaneous invasive electrophysiological signals can be derived through brain interfaces,[270–272] using electrocorticography (ECoG)[273,274] on the cortical surface as well as local field potentials (LFP)[275,276] extracted from electrodes inserted into the cortex.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [274]
In the citing paper
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [150]
Citations
Cites
Wu, Y. (1999) · Technometrics · doi:10.1080/00401706.1999.10485951 · Cited by 27,221
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Neuronal Population Coding of Movement Direction
Georgopoulos, A. P., Schwartz, A. B., & Kettner, R. E. (1986) · Science · doi:10.1126/science.3749885 · Cited by 3,161
Decoding the visual and subjective contents of the human brain
Kamitani, Y., & Tong, F. (2005) · Nature Neuroscience · doi:10.1038/nn1444 · Cited by 1,829
Self-citationCortical control of a prosthetic arm for self-feeding
Velliste, M., Perel, S., Spalding, M. C., Whitford, A. S., & Schwartz, A. B. (2008) · Nature · doi:10.1038/nature06996 · Cited by 1,591
Control of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Real-time prediction of hand trajectory by ensembles of cortical neurons in primates
Wessberg, J., Stambaugh, C. R., Kralik, J. D., Beck, P. D., Laubach, M., Chapin, J. K., Kim, J., Biggs, S. J., Srinivasan, M. A., & Nicolelis, M. A. L. (2000) · Nature · doi:10.1038/35042582 · Cited by 1,487
A brain–computer interface using electrocorticographic signals in humans
Leuthardt, E. C., Schalk, G., Wolpaw, J. R., Ojemann, J. G., & Moran, D. W. (2004) · Journal of Neural Engineering · doi:10.1088/1741-2560/1/2/001 · Cited by 1,188
Cited by
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Brain-Computer Interfaces in Medicine
Shih, J. J., Krusienski, D. J., & Wolpaw, J. R. (2012) · Mayo Clinic Proceedings · doi:10.1016/j.mayocp.2011.12.008 · Cited by 724
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Brain-Computer Interfaces Using Electrocorticographic Signals
Schalk, G., & Leuthardt, E. C. (2011) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2011.2172408 · Cited by 427
Electrocorticographic control of a prosthetic arm in paralyzed patients
Yanagisawa, T., Hirata, M., Saitoh, Y., Kishima, H., Matsushita, K., Goto, T., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T. (2012) · Annals of Neurology · doi:10.1002/ana.22613 · Cited by 256
Self-citationHotson, G., McMullen, D. P., Fifer, M. S., Johannes, M. S., Katyal, K. D., Para, M. P., Armiger, R., Anderson, W. S., Thakor, N. V., Wester, B. A., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026017 · Cited by 201
Multi-Modal Sensing Techniques for Interfacing Hand Prostheses: A Review
Fang, Y., Hettiarachchi, N., Zhou, D., & Liu, H. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2015.2450211 · Cited by 172
“[91], [97] use the power modulations of ECoG signals to control a prosthetic hand, and demon-”
BackgroundMethodInfluentialRegulation of Motor Representation by Phase–Amplitude Coupling in the Sensorimotor Cortex
Yanagisawa, T., Yamashita, O., Hirata, M., Kishima, H., Saitoh, Y., Goto, T., Yoshimine, T., & Kamitani, Y. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.2929-12.2012 · Cited by 138
Self-citationTranslational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 159
Human brain mapping with multithousand-channel PtNRGrids resolves spatiotemporal dynamics
Tchoe, Y., Bourhis, A. M., Cleary, D. R., Stedelin, B., Lee, J., Tonsfeldt, K. J., Brown, E. C., Siler, D. A., Paulk, A. C., Yang, J. C., et al. (2022) · Science Translational Medicine · doi:10.1126/scitranslmed.abj1441 · Cited by 135
Decoding Movement From Electrocorticographic Activity: A Review
Volkova, K., Lebedev, M. A., Kaplan, A., & Ossadtchi, A. (2019) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2019.00074 · Cited by 110
“Early detection of the intention to move is important for BCI applications because it allows decreasing the delay between the brain activity and the response of the prosthetic device (Lebedev et al., 2008; Yanagisawa et al., 2011).”
BackgroundMethodInfluentialFunction of the nucleus accumbens in motor control during recovery after spinal cord injury
Sawada, M., Kato, K., Kunieda, T., Mikuni, N., Miyamoto, S., Onoe, H., Isa, T., & Nishimura, Y. (2015) · Science · doi:10.1126/science.aab3825 · Cited by 109
Applications of brain-computer interfaces to the control of robotic and prosthetic arms
Vilela, M., & Hochberg, L. R. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00008-1 · Cited by 118
Shimoda, K., Nagasaka, Y., Chao, Z. C., & Fujii, N. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/3/036015 · Cited by 97
“Online sECoG-based BMI experiments in human subjects have shown one- and two-dimensional cursor control in epileptic patients [4, 5, 15] and the control of the three types of hand movements in poststroke patients [6].”
BackgroundDetection of motor execution using a hybrid fNIRS-biosignal BCI: a feasibility study
Zimmermann, R., Marchal-Crespo, L., Edelmann, J., Lambercy, O., Fluet, M.-C., Riener, R., Wolf, M., & Gassert, R. (2013) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-10-4 · Cited by 93
Biosignal-Based Human–Machine Interfaces for Assistance and Rehabilitation: A Survey
Esposito, D., Centracchio, J., Andreozzi, E., Gargiulo, G. D., Naik, G. R., & Bifulco, P. (2021) · Sensors · doi:10.3390/s21206863 · Cited by 103
“presented an invasive BCI system for controlling a prosthetic hand by using ECoG signals of a poststroke patient [78].”
MethodFifer, M. S., Hotson, G., Wester, B. A., McMullen, D. P., Wang, Y., Johannes, M. S., Katyal, K. D., Helder, J. B., Para, M. P., Vogelstein, R. J., et al. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2013.2286955 · Cited by 88
“A large amount of decoding and BMI success has been achieved using command signals derived from iEEG [6], [7], [13], [14], [38].”
BackgroundMethodNeuroprosthetic technology for individuals with spinal cord injury
Collinger, J. L., Foldes, S. T., Bruns, T. M., Wodlinger, B., Gaunt, R. A., & Weber, D. J. (2013) · Journal of Spinal Cord Medicine · doi:10.1179/2045772313y.0000000128 · Cited by 100
Zhou, H., & Alıcı, G. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3169492 · Cited by 101
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83
The Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 90
Fifer, M. S., Acharya, S., Benz, H. L., Mollazadeh, M., Crone, N. E., & Thakor, N. V. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2175636 · Cited by 74
“This broad area of research, known as BMI, is attempting to leverage patients’ still-functional brains for direct control of a machine, be it a prosthetic hand [4], a computer cursor [5], or a wheelchair [6].”
BackgroundMethodAI Applications in Adult Stroke Recovery and Rehabilitation: A Scoping Review Using AI
Senadheera, I., Hettiarachchi, P., Haslam, B. S., Nawaratne, R., Sheehan, J., Lockwood, K. J., Alahakoon, D., & Carey, L. M. (2024) · Sensors · doi:10.3390/s24206585 · Cited by 111
“Yanagisawa et al. [95] used BCI with electrocorticography to control a prosthetic arm in real-time and classified arm movements using the support vector machine (SVM) classification algorithm for restoring upper limb motor function.”
BackgroundMethodExtracting kinetic information from human motor cortical signals
Flint, R. D., Wang, P. T., Wright, Z. A., King, C., Krucoff, M. O., Schuele, S., Rosenow, J. M., Hsu, F. P. K., Liu, C. Y., Lin, J. J., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.049 · Cited by 79
“An ECoG-based BMI has been used by a few subjects to move a prosthetic hand to one of two discretely-decoded hand postures, but not manipulate objects (Yanagisawa et al., 2011).”
BackgroundMethodLee, H. S., Schreiner, L., Jo, S.-H., Sieghartsleitner, S., Jordan, M., Pretl, H., Guger, C., & Park, H. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.1009878 · Cited by 88
“Therefore, to better understand and rehabilitate the finger-related motor cortex, a considerable amount of research has been conducted (Kubánek et al., 2009; Acharya et al., 2010; Yanagisawa et al., 2011; Flamary and Rakotomamonjy, 2012; Liang and Bougrain, 2012; Hotson et al., 2016).”
BackgroundInnovations in Prosthetic Interfaces for the Upper Extremity
Kung, T. A., Bueno, R. A., Alkhalefah, G. K., Langhals, N. B., Urbanchek, M. G., & Cederna, P. S. (2013) · Plastic and Reconstructive Surgery · doi:10.1097/prs.0b013e3182a97e5f · Cited by 71
Deep learning for EEG-based Motor Imagery classification: Accuracy-cost trade-off
León, J., Escobar, J. J., Ortíz, A., Ortega, J., González, J., Martín-Smith, P., Gan, J. Q., & Damas, M. (2020) · PLoS ONE · doi:10.1371/journal.pone.0234178 · Cited by 76
A Review of Control Strategies in Closed-Loop Neuroprosthetic Systems
Wright, J. C., Macefield, V. G., André, V. S., & Tapson, J. C. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00312 · Cited by 77
“Yanagisawa et al. (2011) used ECog electrodes placed over the sensorimotor cortex of a stroke patient in order to control a supernumerary robotic hand that was able to mimic the hand posture of the subject.”
MethodModulation of Motor Learning Capacity by Transcranial Alternating Current Stimulation
Sugata, H., Yagi, K., Yazawa, S., Nagase, Y., Tsuruta, K., Ikeda, T., Matsushita, K., Hara, M., Kawakami, K., & Kawakami, K. (2018) · Neuroscience · doi:10.1016/j.neuroscience.2018.09.013 · Cited by 71
Progress in speech decoding from the electrocorticogram
Chakrabarti, S., Sandberg, H. M., Brumberg, J. S., & Krusienski, D. J. (2015) · Biomedical Engineering Letters · doi:10.1007/s13534-015-0175-1 · Cited by 75
Spüler, M., Walter, A., Ramos‐Murguialday, A., Naros, G., Birbaumer, N., Gharabaghi, A., Rosenstiel, W., & Bogdan, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066008 · Cited by 78
Hwaidi, J. F., & Chen, T. (2022) · IEEE Access · doi:10.1109/access.2022.3171906 · Cited by 77
“Electrocorticogra-phy (ECoG) [6] is a semi-invasive method that only requires surgery to implant devices on the brain’s surface.”
MethodDecoding onset and direction of movements using Electrocorticographic (ECoG) signals in humans
Wang, Z., Gunduz, A., Brunner, P., Ritaccio, A. L., Ji, Q., & Schalk, G. (2012) · Frontiers in Neuroengineering · doi:10.3389/fneng.2012.00015 · Cited by 72
“For example, a BCI that detects intended movement onset in absence of actual movements could restore grasp function in people with chronic stroke (Buch et al., 2008; Daly and Wolpaw, 2008; Wisneski et al., 2008; Muralidharan et al., 2011; Yanagisawa et al., 2011).”
BackgroundInfluentialSignal quality of simultaneously recorded endovascular, subdural and epidural signals are comparable
John, S. E., Opie, N. L., Wong, Y. T., Rind, G. S., Ronayne, S. M., Gerboni, G., Bauquier, S. H., O’Brien, T. J., May, C. N., Grayden, D. B., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-26457-7 · Cited by 61
Rapid Decoding of Hand Gestures in Electrocorticography Using Recurrent Neural Networks
Pan, G., Li, J., Qi, Y., Yu, H., Zhu, J., Zheng, X., Wang, Y., & Zhang, S. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00555 · Cited by 73
“Yanagisawa et al. (2011) proposed a real-time decoding system to classify three hand gestures with a linear classifier.”
BackgroundProgress in the Field of Micro-Electrocorticography
Shokoueinejad, M., Park, D., Jung, Y. H., Brodnick, S. K., Novello, J., Dingle, A. M., Swanson, K. I., Baek, D.-H., Suminski, A. J., Lake, W. B., et al. (2019) · Micromachines · doi:10.3390/mi10010062 · Cited by 71
“ECoG BCIs concentrate on both restoring communication [19] and the control of prosthetic limbs [20,21].”
BackgroundVansteensel, M. J., Klein, E., van Thiel, G., Gaytant, M., Simmons, Z., Wolpaw, J. R., & Vaughan, T. M. (2023) · Journal of Neurology · doi:10.1007/s00415-022-11464-6 · Cited by 59
Brain–machine interfaces for rehabilitation of poststroke hemiplegia
Ushiba, J., & Soekadar, S. R. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.04.020 · Cited by 63
A 128-Channel FPGA-Based Real-Time Spike-Sorting Bidirectional Closed-Loop Neural Interface System
Park, J., Kim, G., & Jung, S.-D. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2697415 · Cited by 61
Grahn, P. J., Mallory, G. W., Berry, B. M., Hachmann, J. T., Lobel, D. A., & Luján, J. L. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00296 · Cited by 69
“Recent advances in the fields of BMIs and electrical stimulation therapy provide a promising outlook for patients with SCI.”
BackgroundMethodInfluentialProceedings of the Third International Workshop on Advances in Electrocorticography
Ritaccio, A., Beauchamp, M., Bosman, C., Brunner, P., Chang, E., Crone, N., Gunduz, A., Gupta, D., Knight, R., Leuthardt, E., et al. (2012) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2012.09.016 · Cited by 56
Towards Effective Non-Invasive Brain-Computer Interfaces Dedicated to Gait Rehabilitation Systems
Castermans, T., Duvinage, M., Cheron, G. A., & Dutoit, T. (2013) · Brain Sciences · doi:10.3390/brainsci4010001 · Cited by 63
Decoding fingertip trajectory from electrocorticographic signals in humans
Nakanishi, Y., Yanagisawa, T., Shin, D., Chen, C., Kambara, H., Yoshimura, N., Fukuma, R., Kishima, H., Hirata, M., & Koike, Y. (2014) · Neuroscience Research · doi:10.1016/j.neures.2014.05.005 · Cited by 59
“…assist suit for humans (Sakurada et al., 2013), onset detection of hand extension (Bashashati et al., 2007) and grasping (Pistohl et al., 2013), classification of grasping type in monkeys (Stark and Abeles, 2007) and in humans (Yanagisawa et al., 2011; Pistohl et al., 2012; Chestek et al., 2013).”
BackgroundSelf-citationHammer, J., Fischer, J., Ruescher, J., Schulze-Bonhage, A., Aertsen, A., & Ball, T. (2013) · Frontiers in Neuroscience · doi:10.3389/fnins.2013.00200 · Cited by 49
“…(SUA) in monkeys (Carmena et al., 2003) and humans (Hochberg et al., 2006; Collinger et al., 2013) and also with electrocorticography (ECoG) (Yanagisawa et al., 2011; Milekovic et al., 2012), utilizing a low frequency component (LFC) of measured neuronal population signals (Milekovic et…”
MethodPhysiological properties of brain-machine interface input signals
Slutzky, M. W., & Flint, R. D. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00070.2017 · Cited by 46
“…has been used to control cursors, using biofeedback (Bundy et al. 2012; Leuthardt et al. 2004; Miller et al. 2010; Schalk et al. 2008), biomimetic (Milekovic et al. 2012), and hybrid/adaptive BMIs (Wang et al. 2013), and robotic hands and arms (Hotson et al. 2016; Yanagisawa et al. 2011, 2012).”
MethodBelkacem, A. N., Nishio, S., Suzuki, T., Ishiguro, H., & Hirata, M. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2837003 · Cited by 47
Self-citationMatsushita, K., Hirata, M., Suzuki, T., Ando, H., Yoshida, T., Ota, Y., Sato, F., Morris, S., Sugata, H., Goto, T., et al. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00511 · Cited by 45
“We investigated the detection of frequency components, which determines the classification performance of the SVM. Previous research (Yanagisawa et al., 2009, 2011, 2012; Hirata et al., 2011) on wired ECoG BMI devices indicates that ECoG signals at 5 V with bandwidths of 60–200 Hz and those at 50…”
MethodSelf-citationBauer, R. H., & Gharabaghi, A. (2015) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2015.00021 · Cited by 47
“While assistive BCIs aim to replace lost functions by controlling external devices (Yanagisawa et al., 2011; Hochberg et al., 2012; Collinger et al., 2013; Wang et al., 2013), the ultimate goal of restorative or therapeutic approaches is to improve specific functions by neurofeedback (NFB) training,…”
Murphy, M. D., Guggenmos, D. J., Bundy, D. T., & Nudo, R. J. (2016) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2015.00497 · Cited by 58
“A study in a hemiparetic patient demonstrated that it is possible to use ECoG to control a prosthetic arm using recordings from sensorimotor cortex (Yanagisawa et al., 2011).”
BackgroundTowards Rehabilitation Robotics: Off-the-Shelf BCI Control of Anthropomorphic Robotic Arms
Athanasiou, A., Xygonakis, I., Pandria, N., Kartsidis, P. E., Arfaras, G., Kavazidi, K. R., Foroglou, N., Astaras, A., & Bamidis, P. D. (2017) · BioMed Research International · doi:10.1155/2017/5708937 · Cited by 50
Zamani, M., Jiang, D., & Demosthenous, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2825421 · Cited by 51
“, hand prosthesis [3], [4]) and restoration of lost cognitive function [5].”
BackgroundZamani, M., & Demosthenous, A. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2309678 · Cited by 49
SSVEP based BMI for a meal assistance robot
Perera, C. J., Naotunna, I., Sadaruwan, C., Gopura, R. A. R. C., & Lalitharatne, T. D. (2016) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2016.7844580 · Cited by 43
“(ECoG) [15], [16] and Targeted Muscle Reinnervation based [17] control of upper-limb prostheses has been reported.”
BackgroundNeurotechnologies to restore hand functions
Losanno, E., Mender, M. J., Chestek, C. A., Shokur, S., & Micera, S. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00054-4 · Cited by 49
Meal assistance robots: A review on current status, challenges and future directions
Naotunna, I., Perera, C. J., Sandaruwan, C., Gopura, R. A. R. C., & Lalitharatne, T. D. (2015) · IEEE/SICE International Symposium on System Integration (SII) · doi:10.1109/sii.2015.7404980 · Cited by 41
From assistance towards restoration with epidural brain-computer interfacing
Gharabaghi, A., Naros, G., Walter, A., Grimm, F., Schuermeyer, M., Roth, A., Bogdan, M., Rosenstiel, W., & Birbaumer, N. (2014) · Restorative Neurology and Neuroscience · doi:10.3233/rnn-140387 · Cited by 37
“…these limitationsthankstotheirproximitytotheneuralsignalsource in stroke patients have been implemented as assistive devices for prosthetic control (Yanagisawa et al., 2011 rather than for functional restoration in the context BCIs in patients with motor deficits remain in direct contact with the…”
Morshed, B. I. (2014) · Journal of Bioengineering and Biomedical Sciences · doi:10.4172/2155-9538.1000128 · Cited by 42
Learned self-regulation of the lesioned brain with epidural electrocorticography
Gharabaghi, A., Naros, G., Khademi, F., Jesser, J., Spüler, M., Walter, A., Bogdan, M., Rosenstiel, W., & Birbaumer, N. (2014) · Frontiers in Behavioral Neuroscience · doi:10.3389/fnbeh.2014.00429 · Cited by 39
“We recently proposed a new approach which is less invasive than the classical implanted approaches with subdural grids (Yanagisawa et al., 2011, 2012; Wang et al., 2013) or even brain penetrating electrodes (Hochberg et al., 2012; Collinger et al., 2013).”
AJILE Movement Prediction: Multimodal Deep Learning for Natural Human Neural Recordings and Video
Wang, N., Farhadi, A., Rao, R. P. N., & Brunton, B. W. (2018) · Proceedings of the AAAI Conference on Artificial Intelligence · doi:10.1609/aaai.v32i1.11889 · Cited by 38
Characterization and Decoding the Spatial Patterns of Hand Extension/Flexion using High-Density ECoG
Jiang, T., Jiang, T., Wang, T., Mei, S., Liu, Q., Li, Y., Wang, X., Prabhu, S. S., Sha, Z., & Ince, N. F. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2647255 · Cited by 39
“Now it is used not only for clinical decision making but also for brain machine interface (BMI) studies [4]–[12].”
BackgroundClosed-Loop Control of a Neuroprosthetic Hand by Magnetoencephalographic Signals
Fukuma, R., Yanagisawa, T., Yorifuji, S., Kato, R., Yokoi, H., Hirata, M., Saitoh, Y., Kishima, H., Kamitani, Y., & Yoshimine, T. (2015) · PLoS ONE · doi:10.1371/journal.pone.0131547 · Cited by 32
“Restoration of upper limb function by brain–machine interface (BMI) [1,2] is becoming a therapeutic option for severely paralyzed patients [3,4] to improve their daily life [5].”
BackgroundSelf-citationChen, C., Shin, D., Watanabe, H., Nakanishi, Y., Kambara, H., Yoshimura, N., Nambu, A., Isa, T., Nishimura, Y., & Koike, Y. (2014) · Neuroscience Research · doi:10.1016/j.neures.2014.03.010 · Cited by 33
“…studies on cursor control (Leuthardt et al., 2004; Schalk et al., 2008; Wang et al., 2013), classification of hand movement (Chin et al., 2007; Yanagisawa et al., 2009, 2011), and grasp types (Pistohl et al., 2012), detection of grasp initiation (Pistohl et al., 2013), and decoding of hand…”
Patient-Specific Cortical Electrodes for Sulcal and Gyral Implantation
Morris, S., Hirata, M., Sugata, H., Goto, T., Matsushita, K., Yanagisawa, T., Saitoh, Y., Kishima, H., & Yoshimine, T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2329812 · Cited by 31
“In comparison with standard electroencephalographic electrodes, ECoG electrodes provide not only superior spatial resolution, but also deliver signals with higher sensitivities in the higher frequency ranges, making them useful for neural decoding utilizing high-gamma-band eventrelated oscillatory changes [14], [15].”
BackgroundMethodSelf-citationNeural decoding of electrocorticographic signals using dynamic mode decomposition
Shiraishi, Y., Kawahara, Y., Yamashita, O., Fukuma, R., Yamamoto, S., Saitoh, Y., Kishima, H., & Yanagisawa, T. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab8910 · Cited by 31
Self-citationHuggins, J. E., Guger, C., Ziat, M., Zander, T. O., Taylor, D., Tangermann, M., Soria‐Frisch, A., Simeral, J. D., Scherer, R., Rupp, R., et al. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2016.1275488 · Cited by 34
Coarse Electrocorticographic Decoding of Ipsilateral Reach in Patients with Brain Lesions
Hotson, G., Fifer, M. S., Acharya, S., Benz, H. L., Anderson, W. S., Thakor, N. V., & Crone, N. E. (2014) · PLoS ONE · doi:10.1371/journal.pone.0115236 · Cited by 30
Nsugbe, E. (2021) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2020.1854357 · Cited by 32
Gruenwald, J., Znobishchev, A., Kapeller, C., Kamada, K., Scharinger, J., & Guger, C. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00901 · Cited by 32
“…2019 | Volume 13 | Article 901 concept of whitening (or spectral equalization) is frequently used in time-frequency analysis (Miller et al., 2009; Yanagisawa et al., 2011; Pistohl et al., 2012), it is less known that it can also be performed in time domain by a simple finiteimpulse response…”
BackgroundMethodInfluentialWang, N. X. R., Olson, J. D., Ojemann, J. G., Rao, R. P. N., & Brunton, B. W. (2016) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2016.00165 · Cited by 34
“…et al., 2012; Nakanishi et al., 2013; Wang et al., 2013a) and finger movements (Miller et al., 2009; Wang et al., 2010), to control robotic arms (Yanagisawa et al., 2011; Fifer et al., 2014; McMullen et al., 2014), and to construct ECoG BCIs (Leuthardt et al., 2006; Schalk et al., 2008; Miller…”
MethodJiang, T., Pellizzer, G., Asman, P., Bastos, D. C. A., Bhavsar, S., Tummala, S., Prabhu, S. S., & Ince, N. F. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00100 · Cited by 27
“INTRODUCTION Brain-machine interfaces (BMI) provide a way to establish voluntary control of prosthetic limbs by decoding signals directly from the sensorimotor area of the brain (Yanagisawa et al., 2011, 2012; Hochberg et al., 2012; Collinger et al., 2013; Wang et al., 2013; Wodlinger et al., 2015).”
BackgroundNeural decoding of unilateral upper limb movements using single trial MEG signals
Sugata, H., Goto, T., Hirata, M., Yanagisawa, T., Morris, S., Matsushita, K., Yoshimine, T., & Yorifuji, S. (2012) · Brain Research · doi:10.1016/j.brainres.2012.05.053 · Cited by 27
Self-citationChoi, H., Lee, J., Park, J., Lee, S., Ahn, K.-H., Kim, I. Y., Lee, K., & Jang, D. P. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8a83 · Cited by 27
Branco, M. P., de Boer, L. M., Ramsey, N. F., & Vansteensel, M. J. (2019) · European Journal of Neuroscience · doi:10.1111/ejn.14342 · Cited by 32
“…decoding of hand movement is highly predictive of BCI performance in real-time applications that use, for instance, prosthetic devices for feedback (Gharabaghi et al., 2014; Yanagisawa et al., 2011) or to control a one-dimensional “brain-click” on a computer program (Vansteensel et al., 2016).”
BackgroundMethodEpidural electrocorticography of phantom hand movement following long-term upper-limb amputation
Gharabaghi, A., Naros, G., Walter, A., Roth, A., Bogdan, M., Rosenstiel, W., Mehring, C., & Birbaumer, N. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00285 · Cited by 26
“1 Division of Functional and Restorative Neurosurgery and Division of Translational Neurosurgery, Department of Neurosurgery, Eberhard Karls University of Tübingen, Tübingen, Germany 2 Neuroprosthetics Research Group, Werner Reichardt Centre for Integrative Neuroscience, Eberhard Karls University of Tübingen, Tübingen…”
InfluentialRajah, G. B., Saber, H., Singh, R., & Rangel-Castilla, L. (2018) · Neurosurgical FOCUS · doi:10.3171/2018.4.focus18130 · Cited by 28
Sugata, H., Hirata, M., Yanagisawa, T., Morris, S., Matsushita, K., Goto, T., Yorifuji, S., & Yoshimine, T. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00620 · Cited by 30
“…(EEG; Bradberry et al., 2010; Shindo et al., 2011), magnetoencephalography (MEG; Mellinger et al., 2007; Buch et al., 2008; Waldert et al., 2008; Wang et al., 2010; Sugata et al., 2012a), and electrocorticography (ECoG; Leuthardt et al., 2004; Schalk et al., 2007; Yanagisawa et al., 2011, 2012a).”
BackgroundMethodInfluentialSelf-citationGesture Decoding Using ECoG Signals from Human Sensorimotor Cortex: A Pilot Study
Li, Y., Zhang, S., Jin, Y., Cai, B., Controzzi, M., Zhu, J., Zhang, J., & Zheng, X. (2017) · Behavioural Neurology · doi:10.1155/2017/3435686 · Cited by 25
“ECoG has also been used to reconstruct high-dimensional arm movement [5, 6], predict movement directions [7] and single finger flexion [8–11], and classify hand gesture type [12, 13] as well as detect gross grasp movement [14, 15] with less training [16].”
BackgroundMethodGlobal research on artificial intelligence-enhanced human electroencephalogram analysis
Chen, X., Tao, X., Wang, F. L., & Xie, H. (2021) · Neural Computing and Applications · doi:10.1007/s00521-020-05588-x · Cited by 28
Regenerative Peripheral Nerve Interfaces for Advanced Control of Upper Extremity Prosthetic Devices
Kumar, N. G., Kung, T. A., & Cederna, P. S. (2021) · Hand Clinics · doi:10.1016/j.hcl.2021.04.005 · Cited by 26
Candrea, D. N., Shah, S., Luo, S., Angrick, M., Rabbani, Q., Coogan, C. G., Milsap, G., Nathan, K., Wester, B. A., Anderson, W. S., et al. (2024) · Communications Medicine · doi:10.1038/s43856-024-00635-3 · Cited by 30
Novel Grasping Mechanisms of 3D‐Printed Prosthetic Hands
Moeinnia, H., Su, H., & Kim, W. S. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202200189 · Cited by 28
Rembado, I., Castagnola, E., Turella, L., Ius, T., Budai, R., Ansaldo, A., Angotzi, G. N., de Bertoldi, F., Ricci, D., Škrap, M., et al. (2016) · International Journal of Neural Systems · doi:10.1142/s0129065716500520 · Cited by 23
Real-Time EMG Signal Processing with Implementation of PID Control for Upper-Limb Prosthesis
Sattar, N. Y., Usama, S. A., Muhammad, S., & Kausar, Z. (2019) · IEEE/ASME International Conference on Advanced Intelligent Mechatronics · doi:10.1109/aim.2019.8868796 · Cited by 24
“Yanagisawa [21] proposed that for complicated data, the LDA and SVM algorithms may be used while in real time hybrid control.”
MethodHashimoto, H., Kameda, S., Maezawa, H., Oshino, S., Tani, N., Khoo, H. M., Yanagisawa, T., Yoshimine, T., Kishima, H., & Hirata, M. (2020) · International Journal of Neural Systems · doi:10.1142/s0129065720500562 · Cited by 22
Self-citationFujiwara, Y., Matsumoto, R., Nakae, T., Usami, K., Matsuhashi, M., Kikuchi, T., Yoshida, K., Kunieda, T., Miyamoto, S., Mima, T., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.058 · Cited by 22
“5A, red and blue); a finding similar to the results of previous ECoG studies (Kubánek et al., 2009; Yanagisawa et al., 2011; Pistohl et al., 2012).”
InfluentialOyama, S., Shimoda, S., Alnajjar, F., Iwatsuki, K., Hoshiyama, M., Tanaka, H., & Hirata, H. (2016) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2016.00019 · Cited by 21
“…Targeted Muscular Reinnervation (TMR) including sensory feedback (Kuiken et al., 2007; Ohnishi et al., 2007; Li et al., 2010), brain interface (Yanagisawa et al., 2011), peripheral nerve interface (Navarro et al., 2005), and new training systems (Pilarski et al., 2011) were invented, but…”
BackgroundThe performance of 9–11-year-old children using an SSVEP-based BCI for target selection
Norton, J. J. S., Mullins, J., Alitz, B. E., & Bretl, T. W. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aacfdd · Cited by 28
“Non-invasive brain–computer interfaces (BCIs) enable users to control external devices (such as computer systems [1, 2], prosthetic arms [3, 4], and robotic vehicles [5]) using brain activity.”
BackgroundWu, X., Metcalfe, B., He, S., Tan, H., & Zhang, D. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3421551 · Cited by 27
“Further, an online control over a prosthetic arm to perform three different hand gestures in real-time was conducted on one stroke participant [60].”
BackgroundSugata, H., Hirata, M., Yanagisawa, T., Matsushita, K., Yorifuji, S., & Yoshimine, T. (2016) · Scientific Reports · doi:10.1038/srep24663 · Cited by 27
Self-citationMagnetoencephalogram-based brain–computer interface for hand-gesture decoding using deep learning
Bu, Y., Harrington, D. L., Lee, R. R., Shen, Q., Angeles‐Quinto, A., Ji, Z., Hansen, H., Hernandez-Lucas, J., Baumgartner, J., Song, T., et al. (2023) · Cerebral Cortex · doi:10.1093/cercor/bhad173 · Cited by 25
Brain-machine interface to control a prosthetic arm with monkey ECoGs during periodic movements
Morishita, S., Sato, K., Watanabe, H., Nishimura, Y., Isa, T., Kato, R., Nakamura, T., & Yokoi, H. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00417 · Cited by 19
“ECoGs have been used to develop output-type BMI systems for twodimensional cursor control and motion prediction of the upper arm (Schalk et al., 2007; Pistohl et al., 2008; Uejima et al., 2009; Yanagisawa et al., 2009; Chao et al., 2010; Yanagisawa et al., 2011).”
BackgroundMethodSelf-citationGearing, M., & Kennedy, P. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00111 · Cited by 21
“ECoG signals are invasive and use the frequency domain recorded from groups of neurons and axons (Yanagisawa et al., 2011; Homer et al., 2013; Ikeda et al., 2014; Kanas et al., 2014; Martin et al., 2014, 2018; Mugler et al., 2014; Hotson et al., 2016; Jiang et al., 2016; Ramsey et al., 2017;…”
BackgroundProceedings of the Second International Workshop on Advances in Electrocorticography
Ritaccio, A. L., Boatman‐Reich, D., Brunner, P., Cervenka, M. C., Cole, A. J., Crone, N. E., Duckrow, R. B., Korzeniewska, A., Litt, B., Miller, K. J., et al. (2011) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2011.09.028 · Cited by 19
Data-driven electrophysiological feature based on deep learning to detect epileptic seizures
Yamamoto, S., Yanagisawa, T., Fukuma, R., Oshino, S., Tani, N., Khoo, H. M., Edakawa, K., Kobayashi, M., Tanaka, M., Fujita, Y., et al. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac23bf · Cited by 17
Self-citationRashid, N., Iqbal, J., Javed, A., Tiwana, M. I., & Khan, U. S. (2018) · BioMed Research International · doi:10.1155/2018/2695106 · Cited by 19
“1 2011 “Real-time control of a prosthetic hand using human electrocorticography signals” [4] ECoG of three movements of left hand (grasping motion, hand opening motion, scissor type motion) 69.”
MethodLim, M. J. R., Lo, Y. T., Tan, Y. Y., Lin, H.-Y., Wang, Y., Tan, D., Wang, E., Ma, Y. Y. N., Ng, J. J. W., Jefree, R. A., et al. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adb88e · Cited by 20
“Classification algorithms, such as support vector machines and linear discriminant analysis, are effective at decoding discrete motor movements, where neural activity at a point in time is used to predict the discrete action to be performed [51–53].”
Fukuma, R., Yanagisawa, T., Yokoi, H., Hirata, M., Yoshimine, T., Saitoh, Y., Kamitani, Y., & Kishima, H. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00478 · Cited by 16
“A BMI works by first recording neural activity and then converting the recorded activity into control of some machine, such as a robotic hand or computer (Yanagisawa et al., 2009, 2011, 2012a,b; Nakanishi et al., 2013, 2014; Fukuma et al., 2015, 2016).”
MethodSelf-citationFatima, N., Shuaib, A. M., & Saqqur, M. (2020) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2020.106069 · Cited by 18
Astaras, A., Moustakas, N., Athanasiou, A., & Gogoussis, A. (2013) · Advances in Human-Computer Interaction · doi:10.1155/2013/641074 · Cited by 16
“Restoration of a certain degree of motor functions [5, 6] and high accuracy control of robotic prosthetic arms using invasive BCIs has already been demonstrated [7].”
BackgroundSellers, K. K., Chung, J. E., Zhou, J., Triplett, M., Dawes, H. E., Haque, R., & Chang, E. F. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1984 · Cited by 14
“This neural activity is useful for a variety of diagnostic and therapeutic purposes, including epilepsy seizure localization [1–3] and con-trol of brain–computer interface (BCI) systems for cursor movement [4] or prosthetic limbs [5].”
Metadata
- Authors
- Yanagisawa, T., Hirata, M., Saitoh, Y., Goto, T., Kishima, H., Fukuma, R., Yokoi, H., Kamitani, Y., & Yoshimine, T.
- Affiliations
- Advanced Telecommunications Research Institute International (JP)
- The University of Osaka (JP)
- The University of Tokyo (JP)
- Corresponding author
- Hirata, Masayuki
- ORCID
- Venue
- Journal of Neurosurgery
- Published
- 2011-06
- Volume
- 114
- Issue
- 6
- Pages
- 1715-1722
- ISSN
- 0022-3085 (ISSN-L)
- 1933-0693
- OpenAlex
- W1545922961
- Cited by
- 208
- References
- 33
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 8 · 2023: 13 · 2022: 9 · 2021: 14 · 2020: 16 · 2019: 14 · 2018: 21 · 2017: 9 · 2016: 19 · 2015: 15 · 2014: 24 · 2013: 18 · 2012: 14
- FWCI
- 9.74
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of neurosurgery (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Society for the Promotion of Science (22700435, 22390275, 23390347)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- electrocorticography, brain-computer interface, prosthetic hand control, stroke, motor recovery, real-time decoding, subdural electrodes, sensorimotor cortex, support vector machine, time-frequency analysis, frequency band selection, upper limb prosthesis
- MeSH terms
- Artificial Limbs, Electroencephalography, Hand, Humans, Male, Middle Aged, Motor Cortex, Movement, User-Computer Interface, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.