The BION devices: injectable interfaces with peripheral nerves and muscles
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Object: The purpose of this study was to describe a novel technology for implantable neuromuscular stimulation to treat complications of paralysis and disuse atrophy, including shoulder subluxation, hand contractures, drop foot, and osteoarthritis. The authors review the results so far of several pilot clinical studies of these muscle stimulation devices. Methods: Miniature wireless stimulators received power and individually addressed command signals from an external radiofrequency transmission coil. One or more implants were injected through a 12-gauge hypodermic insertion tool into muscles or adjacent to motor nerves, where they provided the means to activate the muscles in any desired pattern of intensity and frequency. Randomized controlled studies in small numbers of patients are underway to identify efficacy, acceptability, best methods of practice, and any design changes that may be required to improve the technology. Fifty patients have been enrolled in five studies; 35 patients have undergone implantation of a total of 79 BION1 devices. Comparisons with surface stimulation in patients who have suffered a stroke with shoulder subluxation and hand contractures show similar improvements in objective measures of efficacy but higher comfort levels for stimulation by implants. Conclusions: Injected microstimulators represent a promising new class of technology for the rehabilitation of patients with upper motor neuropathies. As the technology evolves, practitioners may be able to use it to facilitate functional reanimation of paralyzed limbs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277
Smith, B., Tang, Z., Johnson, M. W., Pourmehdi, S., Gazdik, M. M., Buckett, J. R., & Peckham, P. H. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.664202 · Cited by 270
BION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243
Self-citationKern, H., Hofer, C., Mödlin, M., Forstner, C., Raschka‐Högler, D., Mayr, W., & Stöhr, H. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06933.x · Cited by 100
Satisfaction with and usage of a hand neuroprosthesis
Wuolle, K. S., Van Doren, C. L., Bryden, A. M., Hunter Peckham, P., Keith, M. W., Kilgore, K. L., & Grill, J. H. (1999) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(99)90123-5 · Cited by 70
First clinical experience with BION implants for therapeutic electrical stimulation
Salter, A.-C. D., Bagg, S. D., Creasy, J. L., Romano, C., Romano, D., Richmond, F. J. R., & Loeb, G. E. (2004) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/j.1525-1403.2004.04005.x · Cited by 66
Self-citationLong-term biocompatibility of a miniature stimulator implanted in feline hind limb muscles
Cameron, T., Liinamaa, T. L., Loeb, G. E., & Richmond, F. J. R. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.704871 · Cited by 53
Self-citationFunctional Electrical Stimulation For Walking In Paraplegia: 17-Year Follow-Up Of 2 Cases
Agarwal, S., Kobetic, R., Nandurkar, S., & Marsolais, E. B. (2003) · The Journal of Spinal Cord Medicine · doi:10.1080/10790268.2003.11753666 · Cited by 49
Functional electrical stimulation using microstimulators to correct foot drop: a case study
Weber, D. J., Stein, R. B., Chan, K. M., Loeb, G. E., Richmond, F. J. R., Rolf, R., James, K., Chong, S. L., Thompson, A. K., & Misiaszek, J. (2004) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y04-078 · Cited by 44
Self-citation
Cited by
Wireless Power Delivery to Flexible Subcutaneous Implants Using Capacitive Coupling
Jegadeesan, R., Agarwal, K., Guo, Y.-X., Yen, S.-C., & Thakor, N. V. (2017) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2016.2615623 · Cited by 184
“with current FDA approved commercial chronic implant devices [1]–[5].”
BackgroundWireless technologies for implantable devices
Nelson, B. D., Karipott, S. S., Wang, Y., & Ong, K. G. (2020) · Sensors · doi:10.3390/s20164604 · Cited by 125
Wireless communication with implanted medical devices using the conductive properties of the body
Ferguson, J. E., & Redish, A. D. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.16 · Cited by 112
Active Neural Interface Circuits and Systems for Selective Control of Peripheral Nerves: A Review
Habibollahi, M., Jiang, D., Lancashire, H. T., & Demosthenous, A. (2024) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2024.3430038 · Cited by 11
“…interface [81], [82], the mi-crobead stimulating system [83], and the intraspinal microstimulation (ISMS) network [47], [84], [85], as well as the injectable neural stimulator (InNS) technologies, which enable interfacing with regions that are inaccessible for implantation [86], [87], [88].”
Metadata
- Authors
- Loeb, G. E., Richmond, F. J. R., & Baker, L. L.
- Venue
- Neurosurgical Focus
- Published
- 2006-05
- Volume
- 20
- Issue
- 5
- Pages
- 1-9
- ISSN
- 1092-0684 (ISSN-L)
- OpenAlex
- W2168637508
- Cited by
- 88
- References
- 9
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The BION devices: injectable interfaces with peripheral nerves and muscles. https://app.cochat.ai/papers/10.3171/foc.2006.20.5.3
- The paper
- Loeb, G. E., Richmond, F. J. R., & Baker, L. L. (2006). The BION devices: injectable interfaces with peripheral nerves and muscles. Neurosurgical Focus. https://doi.org/10.3171/foc.2006.20.5.3
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.