Early diagnosis and detection of breast cancer
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Breast cancer is the most common malignancy in women. It is often characterized by a lack of early symptoms, which results in late detection of the disease. Detection at advanced stages of the decease implies the treatment is more difficult and uncertain. The appropriate screening programs have been conducted within the organized preventive examinations and have made significant contributions to the early breast cancer detection. OBJECTIVE: It is necessary to improve the screening process in order to reduce the percentage of female population that is not covered by screening programs and increase the number of early-detected breast cancers. The improvement of the screening program may be reflected in the following: more efficient determination of the list of the women who have to undergo preventive examination, introduction of screening program in thermography as a diagnostic method applied in pre-screening stage, more efficient analysis of mammograms and continuous follow up of patients. METHODS: The identification of target population for breast cancer screening program has been based on the age of women. The improvement of the early breast cancer diagnosis process proposed in this paper is reflected in more efficient determination of the group of women who have to undergo preventive examination based on the factors affecting the occurrence of breast cancer. Inclusion of the pre-screening phase in which thermal imaging could be applied and software support to mammographic detection of tumor are suggested. RESULTS: This paper describes the breast cancer, current screening program and techniques for early-stage breast cancer detection, module of medical information system MEDIS.NET for creating screening list based on the analysis of risk factors affecting the occurrence of breast cancer, mammography and role of thermal imaging in the process of early breast cancer detection. It also presents an overview on important achievements in computer-aided detection and diagnosis of breast cancer in mammography and thermography. CONCLUSIONS: Based on the obtained results, dynamics of preventive examinations for particular groups of women that is different from the standard two-year examinations, can be successfully defined. It can be concluded that the use of a computer system for tumor diagnosis in mammogram based on various methods of image processing can help doctors in decision-making, while the use of thermal imaging in the pre-screening phase would significantly reduce the list of women for screening mammograms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estrogen and the Risk of Breast Cancer
Clemons, M., & Goss, P. (2001) · New England Journal of Medicine · doi:10.1056/nejm200101253440407 · Cited by 1,096
A Meta-analysis of the Effect of Estrogen Replacement Therapy on the Risk of Breast Cancer
Steinberg, K. K. (1991) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1991.03460150089030 · Cited by 626 · cited 1×
“Increased levels of estrogen and progesterone, caused by taking hormone therapy, also increases the risk of getting breast cancer [10,11].”
A support vector machine approach for detection of microcalcifications
El-Naqa, I., Yang, Y., Wernick, M. N., Galatsanos, N. P., & Nishikawa, R. M. (2002) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2002.806569 · Cited by 571
Broeders, M., Moss, S., Nyström, L., Njor, S., Jonsson, H., Paap, E., Massat, N., Duffy, S., Lynge, E., & Paci, E. (2012) · Journal of Medical Screening · doi:10.1258/jms.2012.012078 · Cited by 489 · cited 1×
“The data obtained in several major research studies conducted in European countries show how important is efficient implementation of organized screening programs for early detection of breast cancer [1].”
A review of thermography as promising non-invasive detection modality for breast tumor
Ng, E. Y.-K. (2009) · International Journal of Thermal Sciences · doi:10.1016/j.ijthermalsci.2008.06.015 · Cited by 448
Rating the Risk Factors for Breast Cancer
Singletary, S. E. (2003) · Annals of Surgery · doi:10.1097/01.sla.0000059969.64262.87 · Cited by 363 · cited 1×
“…diagnosed breast cancer – women who once had the breast cancer has a greater chance of getting another breast cancer in the same or other breast [7]; – previously diagnosed non-invasive type of cancer Ductal carcinoma in situ (DCIS) or Lobular carcinoma in situ (LCIS) – some researches show…”
Arora, N., Martins, D., Ruggerio, D., Tousimis, E., Swistel, A. J., Osborne, M. P., & Simmons, R. M. (2008) · The American Journal of Surgery · doi:10.1016/j.amjsurg.2008.06.015 · Cited by 320 · cited 1×
“The diagnostic system implemented by Arora et al. [88] is based on the use of neural networks.”
Implications of surface temperatures in the diagnosis of breast cancer.
Lawson, R. N. (1956) · PubMed · Cited by 319
Thermography Based Breast Cancer Detection Using Texture Features and Support Vector Machine
Acharya, U. R., Ng, E. Y. K., Tan, J.-H., & Sree, S. V. (2012) · Journal of Medical Systems · doi:10.1007/s10916-010-9611-z · Cited by 316 · cited 1×
“Using this classification method, Acharya et al. [91] achieved the classification accuracy of 88.1%.”
InfluentialVerkasalo, P. K., Thomas, H. V., Appleby, P. N., Davey, G. K., & Key, T. J. (2001) · Cancer Causes & Control · doi:10.1023/a:1008929714862 · Cited by 287 · cited 1×
“In that age, level of estrogen depends on the amount of body fat, wherein more fat indicates a higher level of estrogen [14,15]; – night work – a few studies have suggested that women who work at night have a slight higher risk of breast cancer.”
Gradient and texture analysis for the classification of mammographic masses
Desautels, J. E. L., Rangayyan, R., & Mudigonda, N. R. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.887618 · Cited by 281 · cited 1×
“Mudigonda et al. [24] tested their algorithm for malignant and benign lesion detection on 28 benign and 26 malignant lesions isolated from the mammograms from the mini-MIAS database.”
Menstrual Factors and Risk of Breast Cancer
Brinton, L. A., Schairer, C., Hoover, R. N., & Fraumeni, J. F. (1988) · Cancer Investigation · doi:10.3109/07357908809080645 · Cited by 249 · cited 1×
“Women with denser breast tissue have a higher risk of breast cancer; – menstrual period – starting periods at an early age (before the age of 12) and late menopause (after the age of 55) has been linked with an increased risk of breast cancer [9].”
Markov random field for tumor detection in digital mammography
Li, H. D., Kallergi, M., Clarke, L. P., Jain, V. K., & Clark, R. A. (1995) · IEEE Transactions on Medical Imaging · doi:10.1109/42.414622 · Cited by 246 · cited 1×
“Markov random fields were also used for segmentation of tumor masses in research conducted by Li et al. [45].”
Prospective Study of Estrogen Replacement Therapy and Risk of Breast Cancer in Postmenopausal Women
Colditz, G. A. (1990) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1990.03450200056031 · Cited by 245 · cited 1×
“Increased levels of estrogen and progesterone, caused by taking hormone therapy, also increases the risk of getting breast cancer [10,11].”
Verma, B., & Zakos, J. (2001) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/4233.908389 · Cited by 238 · cited 1×
“A method based on fuzzy logic and a back propagation neural network were applied in the microcalci-fication detection system proposed by Verma and Zakos [57].”
Breast thermography and cancer risk prediction
Gautherie, M., & Gros, C. M. (1980) · Cancer · doi:10.1002/1097-0142(19800101)45:1<51::aid-cncr2820450110>3.0.co;2-l · Cited by 236
Genes other than BRCA1 and BRCA2 involved in breast cancer susceptibility
de Jong, M. M., Nolte, I. M., te Meerman, G. J., van der Graaf, W. T. A., Oosterwijk, J. C., Kleibeuker, J. H., Schaapveld, M., & de Vries, E. G. E. (2002) · Journal of Medical Genetics · doi:10.1136/jmg.39.4.225 · Cited by 235 · cited 1×
“It is assumed that there are several genes that can increase breast cancer risk [6].”
Statistical textural features for detection of microcalcifications in digitized mammograms
Kim, J. K., & Park, H. W. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.764896 · Cited by 216 · cited 1×
“Kim and Park [61] investigated the possibility of microcalcifications detection using three different methods for image features extraction: SRDM (Surrounding Region-Dependence Method), SGLDM (Spatial Gray-Level Dependence Method), GLRLM (Gray-Level Run-Length Method) and GLDM (Gray-Level Difference…”
A novel approach to microcalcification detection using fuzzy logic technique
Cheng, H.-D., Lui, Y. M., & Freimanis, R. I. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712133 · Cited by 208
WOODS, K. S., DOSS, C. C., BOWYER, K. W., SOLKA, J. L., PRIEBE, C. E., & KEGELMEYER, W. P. (1993) · International Journal of Pattern Recognition and Artificial Intelligence · doi:10.1142/s0218001493000698 · Cited by 174 · cited 1×
“Woods et al. [50] have modified the k-nearest neighbors algorithm to obtain an algorithm that is more sensitive in detecting microcalcifications, and less sensitive to healthy breast tissue.”
Analysis of spiculation in the computerized classification of mammographic masses
Huo, Z., Giger, M. L., Vyborny, C. J., Bick, U., Lu, P., Wolverton, D. E., & Schmidt, R. A. (1995) · Medical Physics · doi:10.1118/1.597626 · Cited by 173
Alcohol Consumption and Breast Cancer
(1987) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/78.4.657 · Cited by 172
An artificial intelligent algorithm for tumor detection in screening mammogram
Lei, Z., & Chan, A. K. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.932741 · Cited by 155
Statistical analysis of healthy and malignant breast thermography
Y. K. Ng, L. N. U. (2001) · Journal of Medical Engineering & Technology · doi:10.1080/03091900110086642 · Cited by 142 · cited 1×
“Thermography may warn breast cancer 8–10 years before any other diagnostic method [77].”
Iron: a target for the management of Kaposi's sarcoma?
Simonart, T. (2004) · BMC Cancer · doi:10.1186/1471-2407-4-1 · Cited by 134
Automated detection of breast tumors using the asymmetry approach
Lau, T.-K., & Bischof, W. F. (1991) · Computers and Biomedical Research · doi:10.1016/0010-4809(91)90049-3 · Cited by 127 · cited 1×
“The system for the breast tumors detection presented by Lau and Bischof [40] is based on the analysis of asymmetry in breast structure.”
TAN, T., Quek, C. H., Ng, G. S., & Ng, E. Y. K. (2006) · Expert Systems with Applications · doi:10.1016/j.eswa.2006.06.012 · Cited by 119 · cited 1×
“In order to achieve a thermal equilibrium, it is essential that patients stay without clothes in the recording room for at least 15 minutes before recording [64].”
BREAST THERMOGRAPHY AS A POTENTIAL NON-CONTACT METHOD IN THE EARLY DETECTION OF CANCER: A REVIEW
Etehadtavakol, M., & Ng, E. Y. K. (2013) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519413300019 · Cited by 111
An automatic microcalcification detection system based on a hybrid neural network classifier
Papadopoulos, A., Fotiadis, D. I., & Likas, A. C. (2002) · Artificial Intelligence in Medicine · doi:10.1016/s0933-3657(02)00013-1 · Cited by 109
Ng, E. Y. K., & Sudharsan, N. M. (2004) · BMC Cancer · doi:10.1186/1471-2407-4-17 · Cited by 108
Yu, S., Li, K.-Y., & Huang, Y. (2006) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2006.03.002 · Cited by 93
A modified k-means algorithm to avoid empty clusters
Pakhira, M. K. (n.d.) · Cited by 75
Chen, C. H., & Lee, G. G. (1997) · Graphical Models and Image Processing · doi:10.1006/gmip.1997.0443 · Cited by 69 · cited 1×
“For the breast tumors detection, Chen and Lee [43] applied multiresolution wavelet analysis and expectation-maximization techniques, along with fuzzy logic concepts.”
SEGMENTATION OF BREAST THERMOGRAM: IMPROVED BOUNDARY DETECTION WITH MODIFIED SNAKE ALGORITHM
Ng, E. Y. K., & Chen, Y. (2006) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s021951940600190x · Cited by 66
Metrological Characterization of a CADx System for the Classification of Breast Masses in Mammograms
Mencattini, A., Salmeri, M., Rabottino, G., & Salicone, S. (2010) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2010.2060751 · Cited by 61 · cited 1×
“In order to identify mammograms with breast tumors, the image texture features obtained by the GLC method are often brought to the input of the classifier based on the decision tree [28], as well as to the input of the naive Bayes classifier [29].”
Jacobi, C. E., Jonker, M. A., Nagelkerke, N. J. D., van Houwelingen, H. C., & de Bock, G. H. (2003) · Journal of Medical Genetics · doi:10.1136/jmg.40.7.e83 · Cited by 27 · cited 1×
“Jacobi et al. [2] estimated breast cancer incidence in women under the age of 50, with breast cancer family histories.”
Keyserlingk, J. R., Ahlgren, P. D., Yassa, M., & Belliveau, N. (2002) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2002.1106309 · Cited by 23 · cited 1×
“Similar studies were carried out by Keyserlingk et al. [81,82], which found that the sensitivity of breast tumor detection in mamogram increased from 85% to 95% when mammography was combined with thermal imaging.”
Rajkovic, P. J., Jankovic, D. S., & Milenkovic, A. M. (2013) · Computer Science and Information Systems · doi:10.2298/csis120523056r · Cited by 21
Self-citationLifetime alcohol consumption and breast cancer: a case–control study in Finland
Männistö, S., Virtanen, M. J., Kataja, V. V., Uusitupa, M. I. J., & Pietinen, P. (2000) · Public Health Nutrition · doi:10.1017/s1368980000000033 · Cited by 19 · cited 1×
“Studies also show that there is a correlation between increased breast cancer risk and higher level of a hormone called insulin; – alcohol consumption – it has been shown that drinking alcohol in amounts greater than recommended, slightly increases the risk of developing cancer [12,13].”
A pruned ensemble classifier for effective breast thermogram analysis
Krawczyk, B., & Schaefer, G. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611199 · Cited by 10 · cited 1×
“Almost identical accuracy of positive thermograms recognition of 88.76% was achieved in the research carried out by Krawczyk and Schaefer [92].”
InfluentialBreast cancer among women over 75 years: an important public health problem?
van Schoor, G., Otten, J. D. M., den Heeten, G. J., Holland, R. H., Broeders, M. J. M., & Verbeek, A. L. M. (2012) · European Journal of Public Health · doi:10.1093/eurpub/cks002 · Cited by 5
Cited by
Small nucleolar RNA and its potential role in breast cancer – A comprehensive review
Dsouza, V. L., Adiga, D., Sriharikrishnaa, S., Suresh, P. S., Chatterjee, A., & Kabekkodu, S. P. (2021) · Biochimica et Biophysica Acta (BBA) - Reviews on Cancer · doi:10.1016/j.bbcan.2020.188501 · Cited by 48
Metadata
- Authors
- Milosevic, M., Jankovic, D., Milenkovic, A., & Stojanov, D.
- Venue
- Technology and Health Care
- Publisher
- SAGE Publications
- Published
- 2018-09-27
- Volume
- 26
- Issue
- 4
- Pages
- 729-759
- ISSN
- 0928-7329 (ISSN-L)
- 1878-7401
- OpenAlex
- W2885575853
- Cited by
- 167
- References
- 41
- FWCI
- 5.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.