Receiver Operating Characteristic (ROC) Curve: Practical Review for Radiologists
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Receiver Operating Characteristic (ROC) Curve: Practical Review for RadiologistsThe receiver operating characteristic (ROC) curve, which is defined as a plot of test sensitivity as the y coordinate versus its 1-specificity or false positive rate (FPR) as the x coordinate, is an effective method of evaluating the performance of diagnostic tests.The purpose of this article is to provide a nonmathematical introduction to ROC analysis.Important concepts involved in the correct use and interpretation of this analysis, such as smooth and empirical ROC curves, parametric and nonparametric methods, the area under the ROC curve and its 95% confidence interval, the sensitivity at a particular FPR, and the use of a partial area under the ROC curve are discussed.Various considerations concerning the collection of data in radiological ROC studies are briefly discussed.An introduction to the software frequently used for performing ROC analyses is also presented.he receiver operating characteristic (ROC) curve, which is defined as a plot of test sensitivity as the y coordinate versus its 1-specificity or false positive rate (FPR) as the x coordinate, is an effective method of evaluating the quality or performance of diagnostic tests, and is widely used in radiology to evaluate the performance of many radiological tests.Although one does not necessarily need to understand the complicated mathematical equations and theories of ROC analysis, understanding the key concepts of ROC analysis is a prerequisite for the correct use and interpretation of the results that it provides.This article is a nonmathematical introduction to ROC analysis for radiologists who are not mathematicians or statisticians.Important concepts are discussed along with a brief discussion of the methods of data collection to use in radiological ROC studies.An introduction to the software programs frequently used for performing ROC analyses is also presented. What is the ROC Curve?Sensitivity and specificity, which are defined as the number of true positive decisions/the number of actually positive cases and the number of true negative decisions/the number of actually negative cases, respectively, constitute the basic measures of performance of diagnostic tests (Table 1).When the results of a test fall into one of two obviously defined categories, such as either the presence or absence of a disease, then the test has only one pair of sensitivity and specificity values.However, in many diagnostic situations, making a decision in a binary mode is both difficult and impractical.Image findings may not be obvious or clean-cut.There may be a considerable variation in the diagnostic confidence levels between the radiologists who interpret the findings.As a result, a single pair of sensitivity and specificity values is
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DeLong, E. R., DeLong, D. M., & Clarke-Pearson, D. L. (1988) · Biometrics · doi:10.2307/2531595 · Cited by 22,649
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016 · cited 2×
“It provides the empirical ROC curve and nonparametric estimate of the area under the empirical ROC curve with its 95% CI, based on the method developed by Hanley et al. (7).”
Basic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
Statistical Methods in Diagnostic Medicine
Zhou, X., Obuchowski, N. A., & McClish, D. K. (2011) · Wiley Series in Probability and Statistics · doi:10.1002/9780470906514 · Cited by 1,784
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
Bamber, D. (1975) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(75)90001-2 · Cited by 1,439
Some Practical Issues of Experimental Design and Data Analysis in Radiological ROC Studies
METZ, C. E. (1989) · Investigative Radiology · doi:10.1097/00004424-198903000-00012 · Cited by 859
Receiver Operating Characteristic Curves and Their Use in Radiology
Obuchowski, N. A. (2003) · Radiology · doi:10.1148/radiol.2291010898 · Cited by 843
Brown, R. A., & Motulsky, H. (1997) · Biometrics · doi:10.2307/2533525 · Cited by 800
Cited by
Ahuja, C. S., Wilson, J. R., Nori, S., Kotter, M. R. N., Druschel, C., Curt, A., & Fehlings, M. G. (2017) · Nature Reviews Disease Primers · doi:10.1038/nrdp.2017.18 · Cited by 2,441
Park, S. H., & Han, K. (2018) · Radiology · doi:10.1148/radiol.2017171920 · Cited by 894
Self-citationTranslation of proteomic biomarkers into FDA approved cancer diagnostics: issues and challenges
Füzéry, A. K., Levin, J., Chan, M. M., & Chan, D. W. (2013) · Clinical Proteomics · doi:10.1186/1559-0275-10-13 · Cited by 428
Kirchmair, J., Markt, P., Distinto, S., Wolber, G., & Langer, T. (2008) · Journal of Computer-Aided Molecular Design · doi:10.1007/s10822-007-9163-6 · Cited by 421
Michener, L. A., Walsworth, M. K., Doukas, W. C., & Murphy, K. P. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.05.015 · Cited by 403
Smart Detection: An Online Approach for DoS/DDoS Attack Detection Using Machine Learning
Lima Filho, F. S. D., Silveira, F. A. F., de Medeiros Brito Junior, A., Vargas-Solar, G., & Silveira, L. F. (2019) · Security and Communication Networks · doi:10.1155/2019/1574749 · Cited by 293
Halligan, S., Altman, D. G., & Mallett, S. (2015) · European Radiology · doi:10.1007/s00330-014-3487-0 · Cited by 255
“Baltimore: Johns Hopkins University 2006 and drawn using GraphPad Prism 6·0, La Jolla, USA) diagnostic thresholds [9].”
Predicting the thermodynamic stability of perovskite oxides using machine learning models
Li, W., Jacobs, R., & Morgan, D. (2018) · Computational Materials Science · doi:10.1016/j.commatsci.2018.04.033 · Cited by 255
Decision tree classifiers for automated medical diagnosis
Azar, A. T., & El-Metwally, S. M. (2013) · Neural Computing and Applications · doi:10.1007/s00521-012-1196-7 · Cited by 242
“Receiver operating characteristic, ROC, curves are also used to evaluate the performance of a diagnostic test [45, 67].”
Breast thermography from an image processing viewpoint: A survey
Borchartt, T. B., Conci, A., Lima, R. C. F., Resmini, R., & Sanchez, A. (2013) · Signal Processing · doi:10.1016/j.sigpro.2012.08.012 · Cited by 200
“Most work on the analysis of breast thermal images provide classification results using the accuracy, specificity and sensitivity measures or/and also present the corresponding ROC curves of their methods [83].”
InfluentialEstimation of sex from sternal measurements in a Western Australian population
Franklin, D., Flavel, A., Kuliukas, A., Cardini, A., Marks, M. K., Oxnard, C., & O’Higgins, P. (2012) · Forensic Science International · doi:10.1016/j.forsciint.2011.11.008 · Cited by 164
“The CI of AUC were used to provide indications [20] on the potential significance of relative differences in the predictive performances of the various sets of predictors, taking into account not only accuracy (percentages of correct classifications), but also confidence (e.”
Han, K., Song, K., & Choi, B. W. (2016) · Korean Journal of Radiology · doi:10.3348/kjr.2016.17.3.339 · Cited by 162
“The concordance statistic (c-index), which is mathematically identical to the AUC for a binary outcome, is the most widely used measure to indicate discriminatory ability.”
Influential(2012) · PubMed · Cited by 111
Diler, R. S., Birmaher, B., Axelson, D., Goldstein, B., Gill, M., Strober, M., Kolko, D. J., Goldstein, T. R., Hunt, J., Yang, M., et al. (2009) · Journal of Child and Adolescent Psychopharmacology · doi:10.1089/cap.2008.067 · Cited by 99
“The AUC score is an overall summary of diagnostic accuracy and provides useful information about how a test performs across different cutting scores (Park et al. 2004; Zou et al. 2007).”
Liu, S.-L., Li, S., Guo, Y.-T., Zhou, Y.-P., Zhang, Z.-D., Li, S., & Lu, Y. (2019) · Chinese Medical Journal · doi:10.1097/cm9.0000000000000544 · Cited by 80
Koethe, D., Kranaster, L., Hoyer, C., Gross, S., Neatby, M. A., Schultze-Lutter, F., Ruhrmann, S., Klosterkötter, J., Hellmich, M., & Leweke, F. M. (2009) · European Archives of Psychiatry and Clinical Neuroscience · doi:10.1007/s00406-008-0851-6 · Cited by 56
A machine learning model for screening thermodynamic stable lead-free halide double perovskites
Liang, G.-Q., & Zhang, J. (2022) · Computational Materials Science · doi:10.1016/j.commatsci.2021.111172 · Cited by 44
Abeyasinghe, D. R. R., Tennakoon, S., & Rajapakse, T. N. (2012) · Journal of Affective Disorders · doi:10.1016/j.jad.2012.04.019 · Cited by 32
de Castro, J., MD, Rodríguez, M. C., Martínez-Zorzano, V. S., Sánchez-Rodríguez, P., & Sánchez-Yagüe, J. (2014) · American Journal of Clinical Pathology · doi:10.1309/ajcp1quqqllt8bli · Cited by 26
Finnanger, T. G., Andersson, S., Chevignard, M., Johansen, G. O., Brandt, A. E., Hypher, R. E., Risnes, K., Rø, T. B., & Stubberud, J. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.761755 · Cited by 19
Xu, J., Hu, S., Chen, Q., Shu, L., Wang, P., & Wang, J. (2023) · Scientific Reports · doi:10.1038/s41598-023-41444-3 · Cited by 6
“The accuracy of the nomograms was evaluated using receiver operating characteristic curve (ROC) analysis and calibration 81 .”
Metadata
- Authors
- Park, S. H., Goo, J. M., & Jo, C.-H.
- Venue
- Korean Journal of Radiology
- Publisher
- The Korean Society of Radiology
- Published
- 2004
- Volume
- 5
- Issue
- 1
- Pages
- 11
- ISSN
- 1229-6929 (ISSN-L)
- OpenAlex
- W2129882004
- Cited by
- 907
- References
- 13
- FWCI
- 8.02
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.