Electroenchephalography (EEG) recordings collected with developmental populations present particular challenges from a data processing perspective. These EEGs have a high degree of artifact contamination and often short recording lengths. As both sample sizes and EEG channel densities increase, traditional processing approaches like manual data rejection are becoming unsustainable. Moreover, such subjective approaches preclude standardized metrics of data quality, despite the heightened importance of such measures for EEGs with high rates of initial artifact contamination. There is presently a paucity of automated resources for processing these EEG data and no consistent reporting of data quality measures. To address these challenges, we propose the Harvard Automated Processing Pipeline for EEG (HAPPE) as a standardized, automated pipeline compatible with EEG recordings of variable lengths and artifact contamination levels, including high-artifact and short EEG recordings from young children or those with neurodevelopmental disorders. HAPPE processes event-related and resting-state EEG data from raw files through a series of filtering, artifact rejection, and re-referencing steps to processed EEG suitable for time-frequency-domain analyses. HAPPE also includes a post-processing report of data quality metrics to facilitate the evaluation and reporting of data quality in a standardized manner. Here, we describe each processing step in HAPPE, perform an example analysis with EEG files we have made freely available, and show that HAPPE outperforms seven alternative, widely-used processing approaches. HAPPE removes more artifact than all alternative approaches while simultaneously preserving greater or equivalent amounts of EEG signal in almost all instances. We also provide distributions of HAPPE's data quality metrics in an 867 file dataset as a reference distribution and in support of HAPPE's performance across EEG data with variable artifact contamination and recording lengths. HAPPE software is freely available under the terms of the GNU General Public License at https://github.com/lcnhappe/happe.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371
De-noising by soft-thresholding
Donoho, D. L. (1995) · IEEE Transactions on Information Theory · doi:10.1109/18.382009 · Cited by 9,619
Ideal spatial adaptation by wavelet shrinkage
Donoho, D. L., & Johnstone, I. M. (1994) · Biometrika · doi:10.1093/biomet/81.3.425 · Cited by 8,760
Delorme, A., Sejnowski, T., & Makeig, S. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.004 · Cited by 1,759 · cited 2×
“This combination has previously been used with developmental EEG data (Delorme et al., 2007; Piazza et al., 2016).”
MethodThe PREP pipeline: standardized preprocessing for large-scale EEG analysis
Bigdely-Shamlo, N., Mullen, T., Kothe, C., Su, K.-M., & Robbins, K. A. (2015) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2015.00016 · Cited by 1,351
ADJUST: An automatic EEG artifact detector based on the joint use of spatial and temporal features
Mognon, A., Jovicich, J., Bruzzone, L., & Buiatti, M. (2011) · Psychophysiology · doi:10.1111/j.1469-8986.2010.01061.x · Cited by 1,290
FASTER: Fully Automated Statistical Thresholding for EEG artifact Rejection
Nolan, H., Whelan, R., & Reilly, R. B. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.07.015 · Cited by 1,077
Analysis of Dynamic Brain Imaging Data
Mitra, P. P., & Pesaran, B. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77236-x · Cited by 955
Analysis of Dynamic Brain Imaging Data
Mitra, P. P., & Pesaran, B. (1998) · Cold Spring Harbor Laboratory Institutional Repository (Cold Spring Harbor Laboratory) · Cited by 898
Chaumon, M., Bishop, D. V. M., & Busch, N. A. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.02.025 · Cited by 833
Real-time neuroimaging and cognitive monitoring using wearable dry EEG
Mullen, T. R., Kothe, C. A. E., Chi, Y. M., Ojeda, A., Kerth, T., Makeig, S., Jung, T.-P., & Cauwenberghs, G. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2481482 · Cited by 795
Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals
Winkler, I., Haufe, S., & Tangermann, M. (2011) · Behavioral and Brain Functions · doi:10.1186/1744-9081-7-30 · Cited by 778
Keil, A., Debener, S., Gratton, G., Junghöfer, M., Kappenman, E. S., Luck, S. J., Luu, P., Miller, G. A., & Yee, C. M. (2014) · Psychophysiology · doi:10.1111/psyp.12147 · Cited by 699
Castellanos, N. P., & Makarov, V. A. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.05.033 · Cited by 569
BCILAB: a platform for brain–computer interface development
Kothe, C. A., & Makeig, S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056014 · Cited by 412
On the influence of high-pass filtering on ICA-based artifact reduction in EEG-ERP
Winkler, I., Debener, S., Muller, K.-R., & Tangermann, M. (2015) · 2015 37th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319296 · Cited by 407
Real-time modeling and 3D visualization of source dynamics and connectivity using wearable EEG
Mullen, T., Kothe, C., Chi, Y. M., Ojeda, A., Kerth, T., Makeig, S., Cauwenberghs, G., & Jung, T.-P. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609968 · Cited by 390
Information-based modeling of event-related brain dynamics
Onton, J., & Makeig, S. (2006) · Progress in Brain Research · doi:10.1016/s0079-6123(06)59007-7 · Cited by 386
(1963) · Progress in Brain Research · doi:10.1016/s0079-6123(08)62051-8 · Cited by 334
Robust artifactual independent component classification for BCI practitioners
Winkler, I., Brandl, S., Horn, F., Waldburger, E., Allefeld, C., & Tangermann, M. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/3/035013 · Cited by 327
A comparative study of wavelet families for EEG signal classification
Gandhi, T., Panigrahi, B. K., & Anand, S. (2011) · Neurocomputing · doi:10.1016/j.neucom.2011.04.029 · Cited by 319
Stroganova, T. A., Orekhova, E. V., & Posikera, I. N. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00009-1 · Cited by 229
Developmental Trajectories of Resting EEG Power: An Endophenotype of Autism Spectrum Disorder
Tierney, A. L., Gabard-Durnam, L., Vogel-Farley, V., Tager-Flusberg, H., & Nelson, C. A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0039127 · Cited by 226
Self-citationGrin-Yatsenko, V. A., Baas, I., Ponomarev, V. A., & Kropotov, J. D. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.11.015 · Cited by 211
Lansbergen, M. M., Arns, M., van Dongen-Boomsma, M., Spronk, D., & Buitelaar, J. K. (2011) · Progress in Neuro-Psychopharmacology and Biological Psychiatry · doi:10.1016/j.pnpbp.2010.08.004 · Cited by 209
Systematic biases in early ERP and ERF components as a result of high-pass filtering
Acunzo, D. J., MacKenzie, G., & van Rossum, M. C. W. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.06.011 · Cited by 190
The infant EEG mu rhythm: Methodological considerations and best practices
Cuevas, K., Cannon, E. N., Yoo, K. H., & Fox, N. A. (2014) · Developmental Review · doi:10.1016/j.dr.2013.12.001 · Cited by 168
Arnaud Delorme, A., Makeig, S., B, T. J. S. A., & Pines, N. T. (2001) · Cited by 154
ICA-Based EEG denoising: a comparative analysis of fifteen methods
Albera, L., Kachenoura, A., Comon, P., Karfoul, A., Wendling, F., Senhadji, L., & Merlet, I. (2012) · Bulletin of the Polish Academy of Sciences Technical Sciences · doi:10.2478/v10175-012-0052-3 · Cited by 133
Anatomical correlations of the international 10–20 sensor placement system in infants
Kabdebon, C., Leroy, F., Simmonet, H., Perrot, M., Dubois, J., & Dehaene‐Lambertz, G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.05.046 · Cited by 114
Al-Qazzaz, N. K., Ali, S. H. M., Ahmad, S. A., Islam, M., & Escudero, J. (2017) · Sensors · doi:10.3390/s17061326 · Cited by 101
Alpha Asymmetry in Infants at Risk for Autism Spectrum Disorders
Gabard-Durnam, L., Tierney, A. L., Vogel-Farley, V., Tager-Flusberg, H., & Nelson, C. A. (2015) · Journal of Autism and Developmental Disorders · doi:10.1007/s10803-013-1926-4 · Cited by 85
Self-citationTran, Y., Craig, A. R., Boord, P., & Craig, D. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02347544 · Cited by 62
Hatz, F., Hardmeier, M., Bousleiman, H., Rüegg, S. J., Schindler, C., & Fuhr, P. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.05.014 · Cited by 57
Zima, M., Tichavský, P., Paul, K., & Krajča, V. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/8/n39 · Cited by 49
Piazza, C., Cantiani, C., Akalin-Acar, Z., Miyakoshi, M., BENASICH, A. A., Reni, G., Bianchi, A. M., & Makeig, S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.02.060 · Cited by 40
Stability of ICA decomposition across within-subject EEG datasets
Grandchamp, R., Braboszcz, C., Makeig, S., & Arnaud Delorme, A. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347540 · Cited by 31
Grummett, T. S., Fitzgibbon, S. P., Lewis, T. W., DeLosAngeles, D., Whitham, E. M., Pope, K. J., & Willoughby, J. O. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00927 · Cited by 17
Cited by
Chang, C.-Y., Hsu, S.-H., Pion-Tonachini, L., & Jung, T.-P. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2930186 · Cited by 544
Automagic: Standardized preprocessing of big EEG data
Pedroni, A., Bahreini, A., & Langer, N. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.046 · Cited by 292
Delorme, A. (2023) · Scientific Reports · doi:10.1038/s41598-023-27528-0 · Cited by 260
Longitudinal EEG power in the first postnatal year differentiates autism outcomes
Gabard-Durnam, L. J., Wilkinson, C., Kapur, K., Tager-Flusberg, H., Levin, A. R., & Nelson, C. A. (2019) · Nature Communications · doi:10.1038/s41467-019-12202-9 · Cited by 179
Self-citationThe self and its prolonged intrinsic neural timescale in schizophrenia
Northoff, G., Sandsten, K. E., Nordgaard, J., Kjaer, T. W., & Parnas, J. (2021) · Schizophrenia Bulletin · doi:10.1093/schbul/sbaa083 · Cited by 91
Metadata
- Authors
- Gabard-Durnam, L. J., Mendez Leal, A. S., Wilkinson, C. L., & Levin, A. R.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2018-02-27
- Volume
- 12
- Pages
- 97-97
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W2792847701
- Cited by
- 535
- References
- 38
- FWCI
- 18.95
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.