Immobilized Enzymes in Biosensor Applications

Open access
Nguyen, Hoang Hiep, Lee, Sun Hyeok, Lee, Ui Jin, Fermin, Cesar D., Kim, Moonil · 2019 · Materials

Abstract

Enzyme-based biosensing devices have been extensively developed over the last few decades, and have proven to be innovative techniques in the qualitative and quantitative analysis of a variety of target substrates over a wide range of applications. Distinct advantages that enzyme-based biosensors provide, such as high sensitivity and specificity, portability, cost-effectiveness, and the possibilities for miniaturization and point-of-care diagnostic testing make them more and more attractive for research focused on clinical analysis, food safety control, or disease monitoring purposes. Therefore, this review article investigates the operating principle of enzymatic biosensors utilizing electrochemical, optical, thermistor, and piezoelectric measurement techniques and their applications in the literature, as well as approaches in improving the use of enzymes for biosensors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/ma12010121

Cites

98 of 98 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 91

  1. 2014, Malate quinone oxidoreductase biosensors based on tetrathiafulvalene and gold nanoparticles modified screen-printed carbon electrodes for malic acid determination in wine, Sens. Actuators B Chem., 202, 971, 10.1016/j.snb.2014.06.057 · doi:10.1016/j.snb.2014.06.057
  2. Kurbanoglu, 2018, Amperometric flow injection analysis of glucose and galactose based on engineered pyranose 2-oxidases and osmium polymers for biosensor applications, Electroanalysis, 30, 1496, 10.1002/elan.201800096 · doi:10.1002/elan.201800096
  3. Fernández, H., Arévalo, F.J., Granero, A.M., Robledo, S.N., Nieto, C.H.D., Riberi, W.I., and Zon, M.A. (2017). Electrochemical biosensors for the determination of toxic substances related to food safety developed in South America: Mycotoxins and herbicides. Chemosensors, 5. · doi:10.3390/chemosensors5030023
  4. Tseng, 2009, Thermally stable improved first-generation glucose biosensors based on nafion/glucose-oxidase modified heated electrodes, Electrochem. Commun., 11, 1819, 10.1016/j.elecom.2009.07.030 · doi:10.1016/j.elecom.2009.07.030
  5. Tasca, 2013, Determination of lactose by a novel third generation biosensor based on a cellobiose dehydrogenase and aryl diazonium modified single wall carbon nanotubes electrode, Sens. Actuators B Chem., 177, 64, 10.1016/j.snb.2012.10.114 · doi:10.1016/j.snb.2012.10.114
  6. Hassan, 2017, Tetracaine—selective electrodes with polymer membranes and their application in pharmaceutical formulation control, Arab. J. Chem., 10, S1484, 10.1016/j.arabjc.2013.04.029 · doi:10.1016/j.arabjc.2013.04.029
  7. Gupta, 2010, Drug selective poly(vinyl chloride)-based sensor of desipramine hydrochloride, Electrochim. Acta, 55, 1061, 10.1016/j.electacta.2009.09.061 · doi:10.1016/j.electacta.2009.09.061
  8. Rebriiev, 2004, Enzymatic biosensor based on the ISFET and photopolymeric membrane for the determination of urea, Electroanalysis, 16, 1891, 10.1002/elan.200403077 · doi:10.1002/elan.200403077
  9. Dzyadevych, 2002, Development of enzyme biosensor based on pH-sensitive field-effect transistors for detection of phenolic compounds, Bioelectrochemistry, 55, 79, 10.1016/S1567-5394(01)00165-7 · doi:10.1016/s1567-5394(01)00165-7
  10. Soldatkin, 2005, Analysis of the potato glycoalkaloids by using of enzyme biosensor based on pH-ISFETs, Talanta, 66, 28, 10.1016/j.talanta.2004.11.006 · doi:10.1016/j.talanta.2004.11.006
  11. Rogers, 1991, Light addressable potentiometric biosensor for the detection of anticholinesterases, Anal. Lett., 24, 191, 10.1080/00032719108052896 · doi:10.1080/00032719108052896
  12. Fernando, 1993, Rapid detection of anticholinesterase insecticides by a reusable light addressable potentiometric biosensor, J. Agric. Food Chem., 41, 511, 10.1021/jf00027a031 · doi:10.1021/jf00027a031
  13. Wu, 2009, A novel biomimetic olfactory-based biosensor for single olfactory sensory neuron monitoring, Biosens. Bioelectron., 24, 1498, 10.1016/j.bios.2008.07.065 · doi:10.1016/j.bios.2008.07.065
  14. Yu, 2009, A novel design of multifunctional integrated cell-based biosensors for simultaneously detecting cell acidification and extracellular potential, Biosens. Bioelectron., 24, 1462, 10.1016/j.bios.2008.08.045 · doi:10.1016/j.bios.2008.08.045
  15. Wu, 2016, Sensing of double-stranded DNA molecules by their intrinsic molecular charge using the light-addressable potentiometric sensor, Sens. Actuators B Chem., 229, 506, 10.1016/j.snb.2016.02.004 · doi:10.1016/j.snb.2016.02.004
  16. Du, 2018, Dual functional extracellular recording using a light-addressable potentiometric sensor for bitter signal transduction, Anal. Chim. Acta, 1022, 106, 10.1016/j.aca.2018.03.012 · doi:10.1016/j.aca.2018.03.012
  17. Soldatkin, 1994, Glucose sensitive conductometric biosensor with additional Nafion membrane: reduction of influence of buffer capacity on the sensor response and extension of its dynamic range, Anal. Chim. Acta, 288, 197, 10.1016/0003-2670(93)E0627-J · doi:10.1016/0003-2670(93)e0627-j
  18. Lee, 2000, Sol–gel-derived thick-film conductometric biosensor for urea determination in serum, Anal. Chim. Acta, 404, 195, 10.1016/S0003-2670(99)00699-6 · doi:10.1016/s0003-2670(99)00699-6
  19. Mikkelsen, 1989, Conductometric transducers for enzyme-based biosensors, Anal. Chem., 61, 1737, 10.1021/ac00190a029 · doi:10.1021/ac00190a029
  20. Bilitewski, 1992, Thick film biosensors for urea, Sens. Actuators B Chem., 7, 321, 10.1016/0925-4005(92)80317-Q · doi:10.1016/0925-4005(92)80317-q
  21. Soldatkin, 1994, Thin-film conductometric biosensors for glucose and urea determination, Biosens. Bioelectron., 9, 217, 10.1016/0956-5663(94)80124-X · doi:10.1016/0956-5663(94)80124-x
  22. Kirdeciler, 2011, A novel urea conductometric biosensor based on zeolite immobilized urease, Talanta, 85, 1435, 10.1016/j.talanta.2011.06.034 · doi:10.1016/j.talanta.2011.06.034
  23. Ho, 1999, Electrochemical sensor for measurement of urea and creatinine in serum based on ac impedance measurement of enzyme-catalyzed polymer transformation, Anal. Chem., 71, 1940, 10.1021/ac981367d · doi:10.1021/ac981367d
  24. Jin, 2001, Glucose sensing based on interdigitated array microelectrode, Anal. Sci., 17, 841, 10.2116/analsci.17.841 · doi:10.2116/analsci.17.841
  25. Marrakchi, 2008, Conductometric biosensor based on glucose oxidase and β-galactosidase for specific lactose determination in milk, Mater. Sci. Eng. C, 28, 872, 10.1016/j.msec.2007.10.046 · doi:10.1016/j.msec.2007.10.046
  26. Sergeyeva, 1999, Hydrogen peroxide–Sensitive enzyme sensor based on phthalocyanine thin film, Anal. Chim. Acta, 391, 289, 10.1016/S0003-2670(99)00203-2 · doi:10.1016/s0003-2670(99)00203-2
  27. Dzyadevych, 2002, Assessment of the toxicity of methyl parathion and its photodegradation products in water samples using conductometric enzyme biosensors, Anal. Chim. Acta, 459, 33, 10.1016/S0003-2670(02)00083-1 · doi:10.1016/s0003-2670(02)00083-1
  28. Dzyadevych, 2002, A comparative photodegradation studies of methyl parathion by using Lumistox test and conductometric biosensor technique, Mater. Sci. Eng. C, 21, 55, 10.1016/S0928-4931(02)00058-9 · doi:10.1016/s0928-4931(02)00058-9
  29. Martelet, 1994, Enzyme biosensor based on a micromachined interdigitated conductometric transducer: application to the detection of urea, glucose, acetyl- and butyrylcholine chlordes, Sens. Actuators B Chem., 21, 123, 10.1016/0925-4005(94)80013-8 · doi:10.1016/0925-4005(94)80013-8
  30. Dzydevich, 1994, Conductometric biosensors based on cholinesterases for sensitive detection of pesticides, Electroanalysis, 6, 752, 10.1002/elan.1140060907 · doi:10.1002/elan.1140060907
  31. Arkhypova, 2001, Multibiosensor based on enzyme inhibition analysis for determination of different toxic substances, Talanta, 55, 919, 10.1016/S0039-9140(01)00495-7 · doi:10.1016/s0039-9140(01)00495-7
  32. Rodriguez, 2002, Conductometric uric acid and urea biosensor prepared from electroconductive polyaniline–poly(n-butyl methacrylate) composites, Sens. Actuators B Chem., 85, 19, 10.1016/S0925-4005(02)00045-X · doi:10.1016/s0925-4005(02)00045-x
  33. Dzyadevych, 2001, Conductometric formaldehyde sensitive biosensor with specifically adapted analytical characteristics, Anal. Chim. Acta, 445, 47, 10.1016/S0003-2670(01)01249-1 · doi:10.1016/s0003-2670(01)01249-1
  34. Anh, 2004, Conductometric tyrosinase biosensor for the detection of diuron, atrazine and its main metabolites, Talanta, 63, 365, 10.1016/j.talanta.2003.11.008 · doi:10.1016/j.talanta.2003.11.008
  35. Zehani, 2014, Sensitive impedimetric biosensor for direct detection of diazinon based on lipases, Front. Chem., 2, 1, 10.3389/fchem.2014.00044 · doi:10.3389/fchem.2014.00044
  36. Chan, 2017, l-lactate selective impedimetric bienzymatic biosensor based on lactate dehydrogenase and pyruvate oxidase, Electrochim. Acta, 231, 209, 10.1016/j.electacta.2017.02.050 · doi:10.1016/j.electacta.2017.02.050
  37. Shamsipur, 2012, A novel impedimetric nanobiosensor for low level determination of hydrogen peroxide based on biocatalysis of catalase, Bioelectrochemistry, 83, 31, 10.1016/j.bioelechem.2011.08.003 · doi:10.1016/j.bioelechem.2011.08.003
  38. Zane, 2011, An impedimetric glucose biosensor based on overoxidized polypyrrole thin film, Electroanalysis, 23, 1134, 10.1002/elan.201000576 · doi:10.1002/elan.201000576
  39. Myler, 2005, Sonochemically fabricated microelectrode arrays for biosensors: Part III. AC impedimetric study of aerobic and anaerobic response of alcohol oxidase within polyaniline, Biosens. Bioelectron., 21, 666, 10.1016/j.bios.2004.12.012 · doi:10.1016/j.bios.2004.12.012
  40. Bouyahia, 2011, Impedance spectroscopy and conductometric biosensing for probing catalase reaction with cyanide as ligand and inhibitor, Bioelectrochemistry, 80, 155, 10.1016/j.bioelechem.2010.07.006 · doi:10.1016/j.bioelechem.2010.07.006
  41. Cortina, 2006, Urea impedimetric biosensor based on polymer degradation onto interdigitated electrodes, Sens. Actuators B Chem., 118, 84, 10.1016/j.snb.2006.04.062 · doi:10.1016/j.snb.2006.04.062
  42. Sanz, 2007, A reagentless optical biosensor based on the intrinsic absorption properties of peroxidase, Biosens. Bioelectron., 22, 956, 10.1016/j.bios.2006.04.008 · doi:10.1016/j.bios.2006.04.008
  43. Sanz, 2007, Direct glucose determination in blood using a reagentless optical biosensor, Biosens. Bioelectron., 22, 2876, 10.1016/j.bios.2006.12.015 · doi:10.1016/j.bios.2006.12.015
  44. Lan, 2012, Development of a novel optical biosensor for detection of organophoshorus pesticides based on methyl parathion hydrolase immobilized by metal-chelate affinity, Sensors, 12, 8477, 10.3390/s120708477 · doi:10.3390/s120708477
  45. Choi, 2001, Optical organophosphorus biosensor consisting of acetylcholinesterase/viologen hetero Langmuir-Blodgett film, Biosens. Bioelectron., 16, 937, 10.1016/S0956-5663(01)00213-5 · doi:10.1016/s0956-5663(01)00213-5
  46. Andreu, 2001, Intrinsic fluorescence of enzymes and fluorescence of chemically modified enzymes for analytical purposes: A review, Luminescence, 16, 199, 10.1002/bio.633 · doi:10.1002/bio.633
  47. Sierra, 1998, Fluorimetric-enzymatic determination of glucose based on labelled glucose oxidase, Anal. Chim. Acta, 368, 97, 10.1016/S0003-2670(98)00197-4 · doi:10.1016/s0003-2670(98)00197-4
  48. Sierra, 2000, Direct fluorometric determination of total cholesterol in serum using derivatized cholesterol oxidase, Appl. Spectrosc., 54, 1157, 10.1366/0003702001950968 · doi:10.1366/0003702001950968
  49. Andreu, 2002, Study of a fluorometric-enzymatic method for bilirubin based on chemically modified bilirubin-oxidase and multivariate calibration, Talanta, 57, 343, 10.1016/S0039-9140(02)00023-1 · doi:10.1016/s0039-9140(02)00023-1
  50. Gessei, 2015, A fiber-optic sorbitol biosensor based on NADH fluorescence detection toward rapid diagnosis of diabetic complications, Analyst, 140, 6335, 10.1039/C4AN01593B · doi:10.1039/c4an01593b
  51. Yang, V.C., and Ngo, T.T. (2000). Luminescent biosensors. Biosensors and Their Applications, Springer. · doi:10.1007/978-1-4615-4181-3
  52. Klimant, 1994, Novel metal-organic ruthenium(II) diimin complexes for use as longwave excitable luminescent oxygen probes, Talanta, 41, 985, 10.1016/0039-9140(94)E0051-R · doi:10.1016/0039-9140(94)e0051-r
  53. Papkovsky, 1998, Biosensors on the basis of luminescent oxygen sensor: The use of microporous light-scattering support materials, Sens. Actuators B Chem., 51, 137, 10.1016/S0925-4005(98)00171-3 · doi:10.1016/s0925-4005(98)00171-3
  54. Scully, 2007, Optical fibre biosensors using enzymatic transducers to monitor glucose, Meas. Sci. Technol., 18, 3177, 10.1088/0957-0233/18/10/S20 · doi:10.1088/0957-0233/18/10/s20
  55. Gautier, 1990, Fibre-optic biosensor based on luminescence and immobilized enzymes: Microdetermination of sorbitol, ethanol and oxaloacetate, J. Biolumin. Chemilumin., 5, 57, 10.1002/bio.1170050112 · doi:10.1002/bio.1170050112
  56. Li, 2008, Chemiluminescence flow-through biosensor for glucose with eggshell membrane as enzyme immobilization platform, Anal. Biochem., 374, 64, 10.1016/j.ab.2007.10.036 · doi:10.1016/j.ab.2007.10.036
  57. Milkani, 2011, Direct detection of acetylcholinesterase inhibitor binding with an enzyme-based surface plasmon resonance sensor, Anal. Biochem., 408, 212, 10.1016/j.ab.2010.09.009 · doi:10.1016/j.ab.2010.09.009
  58. Miyazaki, 2017, Surface plasmon resonance biosensor for enzymatic detection of small analytes, Nanotechnology, 28, 145501, 10.1088/1361-6528/aa6284 · doi:10.1088/1361-6528/aa6284
  59. Arya, 2007, Poly-(3-hexylthiophene) self-assembled monolayer based cholesterol biosensor using surface plasmon resonance technique, Biosens. Bioelectron., 22, 2516, 10.1016/j.bios.2006.10.011 · doi:10.1016/j.bios.2006.10.011
  60. Geitmann, 2004, Studies of substrate-induced conformational changes in human cytomegalovirus protease using optical biosensor technology, Anal. Biochem., 332, 203, 10.1016/j.ab.2004.06.008 · doi:10.1016/j.ab.2004.06.008
  61. Mattiasson, 1977, Thermometric enzyme linked immunosorbent assay: TELISA, Biochim. Biophys. Acta, 483, 221, 10.1016/0005-2744(77)90050-X · doi:10.1016/0005-2744(77)90050-x
  62. Yang, 2007, Piezoelectric urea biosensor based on immobilization of urease onto nanoporous alumina membranes, Biosens. Bioelectron., 22, 3283, 10.1016/j.bios.2007.03.006 · doi:10.1016/j.bios.2007.03.006
  63. Seker, 2010, Electrospun nanofibrous PLGA/fullerene-C60 coated quartz crystal microbalance for real-time gluconic acid monitoring, IEEE Sens. J., 10, 1342, 10.1109/JSEN.2010.2043670 · doi:10.1109/jsen.2010.2043670
  64. Alfonta, 2000, Sensing of acetylcholine by a tricomponent-enzyme layered electrode using faradaic impedance spectroscopy, cyclic voltammetry, and microgravimetric quartz crystal microbalance transduction methods, Anal. Chem., 72, 927, 10.1021/ac990439d · doi:10.1021/ac990439d
  65. Karousos, 2002, Quartz crystal microbalance determination of organophosphorus and carbamate pesticides, Anal. Chim. Acta, 469, 189, 10.1016/S0003-2670(02)00668-2 · doi:10.1016/s0003-2670(02)00668-2
  66. 2015, Detection of hydrogen peroxide and glucose by enzyme product precipitation on sensor surface, Chem. Pap., 69, 167
  67. Martin, 2003, Enzyme-based determination of cholesterol using the quartz crystal acoustic wave sensor, Anal. Chim. Acta, 487, 91, 10.1016/S0003-2670(03)00504-X · doi:10.1016/s0003-2670(03)00504-x
  68. Marty, 2009, A review of the use of genetically engineered enzymes in electrochemical biosensors, Semin. Cell Dev. Biol., 20, 3, 10.1016/j.semcdb.2009.01.009 · doi:10.1016/j.semcdb.2009.01.009
  69. Istamboulie, 2007, Highly sensitive detection of organophosphorus insecticides using magnetic microbeads and genetically engineered acetylcholinesterase, Biosens. Bioelectron., 23, 506, 10.1016/j.bios.2007.06.022 · doi:10.1016/j.bios.2007.06.022
  70. Sotiropoulou, 2005, Genetically engineered acetylcholinesterase-based biosensor for attomolar detection of dichlorvos, Biosens. Bioelectron., 20, 2347, 10.1016/j.bios.2004.08.026 · doi:10.1016/j.bios.2004.08.026
  71. Moore, 1996, Electrocatalytic reduction of organic peroxides in organic solvents by microperoxidase-11 immobilized as a monolayer on a gold electrode, J. Electroanal. Chem., 417, 189, 10.1016/S0022-0728(96)04736-5 · doi:10.1016/s0022-0728(96)04736-5
  72. Behera, 2007, Mercaptoethylpyrazine promoted electrochemistry of redox protein and amperometric biosensing of uric acid, Biosens. Bioelectron., 23, 556, 10.1016/j.bios.2007.06.012 · doi:10.1016/j.bios.2007.06.012
  73. Andreescu, 2001, Immobilization of enzymes on screen-printed sensors via an histidine tail. Application to the detection of pesticides using modified cholinesterase, Anal. Lett., 34, 529, 10.1081/AL-100002593 · doi:10.1081/al-100002593
  74. Kapp, 2006, Electrochemical and sensorial behavior of SOD mutants immobilized on gold electrodes in aqueous/organic solvent mixtures, Electroanalysis, 18, 1909, 10.1002/elan.200603620 · doi:10.1002/elan.200603620
  75. Uematsu, 2014, Promotion and suppression effects of cationic polymer ε-poly-L-lysine on the glucose oxidase reaction with ferrocene derivatives as oxidants with different charges, Anal. Sci., 30, 299, 10.2116/analsci.30.299 · doi:10.2116/analsci.30.299
  76. Zhou, 2001, Construction of a fusion enzyme system by gene splicing as a new molecular recognition element for a sequence biosensor, Bioconjug. Chem., 12, 924, 10.1021/bc015509d · doi:10.1021/bc015509d
  77. Groups, 1975, Chemical modification of amino groups and guanidino groups of trypsin, Biochem. J., 147, 71, 10.1042/bj1470071 · doi:10.1042/bj1470071
  78. Palomo, 2007, Modulation of immobilized lipase enantioselectivity via chemical amination, Adv. Synth. Catal., 349, 1119, 10.1002/adsc.200600555 · doi:10.1002/adsc.200600555
  79. Khajeh, 2001, Chemical modification of lysine residues in Bacillus a-amylases: effect on activity and stability, Enzyme Microb. Technol., 28, 543, 10.1016/S0141-0229(01)00296-4 · doi:10.1016/s0141-0229(01)00296-4
  80. Torchilin, 1979, Principles of enzyme stabilization V. The possibility of enzyme selfstabilization under the action of potentially reversible intramolecular cross-linkages of different length, Biochim. Biophys. Acta–Enzymol., 568, 1, 10.1016/0005-2744(79)90267-5 · doi:10.1016/0005-2744(79)90267-5
  81. Reiner, 1977, Chemical modification of enzymes II. Conformational stability of cross-linked bovine pancreatic ribonuclease, J. Mol. Catal., 1, 3, 10.1016/0304-5102(75)80002-2 · doi:10.1016/0304-5102(75)80002-2
  82. Herzig, 1964, Bifunctional reagents and protein structure determination. The reaction of phenolic disulfonyl chlorides with lysozyme, Biopolymers, 2, 349, 10.1002/bip.1964.360020406 · doi:10.1002/bip.1964.360020406
  83. Torchilin, 1984, Stabilization of subunit enzymes by intramolecular crosslinking with bifunctional reagents, Ann. N. Y. Acad. Sci., 434, 27, 10.1111/j.1749-6632.1984.tb29795.x · doi:10.1111/j.1749-6632.1984.tb29795.x
  84. Kim, 2003, Stability and activity of cross-linked enzyme crystals of cyclodextrin glucanotransferase isolated from Bacillus macerans, J. Mol. Catal. B Enzym., 26, 287, 10.1016/j.molcatb.2003.07.007 · doi:10.1016/j.molcatb.2003.07.007
  85. Cui, J.D., Li, L.L., and Bian, H.J. (2013). Immobilization of cross-linked phenylalanine ammonia lyase aggregates in microporous silica gel. PLoS One, 8. · doi:10.1371/journal.pone.0080581
  86. Romero, 2012, Semisynthetic peptide–lipase conjugates for improved biotransformations, Chem. Commun., 48, 9053, 10.1039/c2cc34816k · doi:10.1039/c2cc34816k
  87. Takahashi, 1984, Polyethylene glycol-modified enzymes trap water on their surface and exert enzymic activity in organic solvents, Biotechnol. Lett., 6, 765, 10.1007/BF00134715 · doi:10.1007/bf00134715
  88. Wollenberger, 1993, Enhancing biosensor performance using multienzyme systems, Trends Biotechnol., 11, 255, 10.1016/0167-7799(93)90137-X · doi:10.1016/0167-7799(93)90137-x
  89. Fang, 2016, A novel bi-enzyme electrochemical biosensor for selective and sensitive determination of methyl salicylate, Biosens. Bioelectron., 81, 39, 10.1016/j.bios.2016.01.095 · doi:10.1016/j.bios.2016.01.095
  90. Mansor, N.N.N., Leong, T.T., Safitri, E., Futra, D., Ahmad, N.S., Nasuruddin, D.N., Itnin, A., Zaini, I.Z., Arifin, K.T., and Heng, L.Y. (2018). An amperometric biosensor for the determination of bacterial sepsis biomarker, secretory phospholipase group 2-IIA using a tri-enzyme system. Sensors, 18. · doi:10.3390/s18030686
  91. Hamid, 1989, Flow-through multi-enzyme electrodes for the determination of lactose, Analyst, 114, 1587, 10.1039/an9891401587 · doi:10.1039/an9891401587

Cited by

See all 606

Metadata

Authors
Nguyen, H. H., Lee, S. H., Lee, U. J., Fermin, C. D., & Kim, M.
Venue
Materials
Publisher
MDPI AG
Published
2019-01-02
Volume
12
Issue
1
Pages
121
ISSN
1996-1944 (ISSN-L)
OpenAlex
W2906905739
Cited by
606
References
98
FWCI
23.62
Type
journal article
Language
en
Open access
gold
Funders
Korea Research Institute of Bioscience and Biotechnology (KRIBB Initiative Program)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.