The DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Design Strategies for Aptamer-Based Biosensors
Open accessAbstract
Aptamers have been widely used as recognition elements for biosensor construction, especially in the detection of proteins or small molecule targets, and regarded as promising alternatives for antibodies in bioassay areas. In this review, we present an overview of reported design strategies for the fabrication of biosensors and classify them into four basic modes: target-induced structure switching mode, sandwich or sandwich-like mode, target-induced dissociation/displacement mode and competitive replacement mode. In view of the unprecedented advantages brought about by aptamers and smart design strategies, aptamer-based biosensors are expected to be one of the most promising devices in bioassay related applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vitro selection of RNA molecules that bind specific ligands
Ellington, A. D., & Szostak, J. W. (1990) · Nature · doi:10.1038/346818a0 · Cited by 9,812
Selection of single-stranded DNA molecules that bind and inhibit human thrombin
Bock, L. C., Griffin, L. C., Latham, J. A., Vermaas, E. H., & Toole, J. J. (1992) · Nature · doi:10.1038/355564a0 · Cited by 2,469
Aptamers evolved from live cells as effective molecular probes for cancer study
Shangguan, D., Li, Y., Tang, Z., Cao, Z. C., Chen, H. W., Mallikaratchy, P., Sefah, K., Yang, C. J., & Tan, W. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602615103 · Cited by 1,516
Song, S., Wang, L., Li, J., Fan, C., & Zhao, J. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2007.12.004 · Cited by 1,434
Li, H., & Rothberg, L. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406115101 · Cited by 1,342
Liu, J., & Lu, Y. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200502589 · Cited by 956
Label‐Free Electronic Detection of Thrombin in Blood Serum by Using an Aptamer‐Based Sensor
Xiao, Y., Lubin, A. A., Heeger, A. J., & Plaxco, K. W. (2005) · Angewandte Chemie International Edition · doi:10.1002/anie.200500989 · Cited by 812
DNAzymes for sensing, nanobiotechnology and logic gate applications
Willner, I., Shlyahovsky, B., Zayats, M., & Willner, B. (2008) · Chemical Society Reviews · doi:10.1039/b718428j · Cited by 791
Li, & Rothberg, L. J. (2004) · Journal of the American Chemical Society · doi:10.1021/ja048749n · Cited by 663
Quantum-Dot/Aptamer-Based Ultrasensitive Multi-Analyte Electrochemical Biosensor
Hansen, J. A., Wang, J., Kawde, A.-N., Xiang, Y., Gothelf, K. V., & Collins, G. (2006) · Journal of the American Chemical Society · doi:10.1021/ja060005h · Cited by 538
Xiao, Y., Piorek, B. D., Plaxco, K. W., & Heeger, A. J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja056555h · Cited by 527
Aptamer-Conjugated Nanoparticles for Selective Collection and Detection of Cancer Cells
Herr, J. K., Smith, J. E., Medley, C. D., Shangguan, D., & Tan, W. (2006) · Analytical Chemistry · doi:10.1021/ac052015r · Cited by 431
Aptamer-Based Detection of Plasma Proteins by an Electrochemical Assay Coupled to Magnetic Beads
Centi, S., Tombelli, S., Minunni, M., & Mascini, M. (2007) · Analytical Chemistry · doi:10.1021/ac061879p · Cited by 409
A Gold Nanoparticle‐Based Aptamer Target Binding Readout for ATP Assay
Wang, J., Wang, L., Liu, X., Liang, Z., Song, S., Li, W., Li, G., & Fan, C. (2007) · Advanced Materials · doi:10.1002/adma.200602256 · Cited by 394
Self-citationDNA Aptamer Folding on Gold Nanoparticles: From Colloid Chemistry to Biosensors
Zhao, W., Chiuman, W., Lam, J. C. F., McManus, S. A., Chen, W., Cui, Y., Pelton, R., Brook, M. A., & Li, Y. (2008) · Journal of the American Chemical Society · doi:10.1021/ja710241b · Cited by 376
An RNA Aptamer-Based Electrochemical Biosensor for Detection of Theophylline in Serum
Ferapontova, E. E., Olsen, E. M., & Gothelf, K. V. (2008) · Journal of the American Chemical Society · doi:10.1021/ja711326b · Cited by 364
Aptamer-Conjugated Nanoparticles for the Collection and Detection of Multiple Cancer Cells
Smith, J. E., Medley, C. D., Tang, Z., Shangguan, D., Lofton, C., & Tan, W. (2007) · Analytical Chemistry · doi:10.1021/ac062151b · Cited by 343
Light-switching excimer probes for rapid protein monitoring in complex biological fluids
Yang, C. J., Jockusch, S., Vicens, M., Turro, N. J., & Tan, W. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508821102 · Cited by 337
Li, D., Shlyahovsky, B., Elbaz, J., & Willner, I. (2007) · Journal of the American Chemical Society · doi:10.1021/ja070180d · Cited by 334
Yang, R., Tang, Z., Yan, J., Kang, H., Kim, Y., Zhu, Z., & Tan, W. (2008) · Analytical Chemistry · doi:10.1021/ac801118p · Cited by 304
Aptamers as molecular recognition elements for electrical nanobiosensors
Lee, J.-O., So, H.-M., Jeon, E.-K., Chang, H., Won, K., & Kim, Y. H. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1643-y · Cited by 277
Biomolecule-nanoparticle hybrids for electrochemical biosensors
GUO, S., & DONG, S. (2009) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.10.014 · Cited by 274
Irvine, D., Tuerk, C., & Gold, L. (1991) · Journal of Molecular Biology · doi:10.1016/0022-2836(91)90509-5 · Cited by 266
Protein Detection with Aptamer Biosensors
Strehlitz, B., Nikolaus, N., & Stoltenburg, R. (2008) · Sensors · doi:10.3390/s8074296 · Cited by 237
Gene therapy progress and prospects: RNA aptamers
Que-Gewirth, N. S., & Sullenger, B. A. (2007) · Gene Therapy · doi:10.1038/sj.gt.3302900 · Cited by 227
Zhao, W., Chiuman, W., Brook, M. A., & Li, Y. (2007) · ChemBioChem · doi:10.1002/cbic.200700014 · Cited by 225
Aptamer-Based SERRS Sensor for Thrombin Detection
Cho, H., Baker, B. R., Wachsmann-Hogiu, S., Pagba, C. V., Laurence, T. A., Lane, S. M., Lee, L. P., & Tok, J. B.-H. (2008) · Nano Letters · doi:10.1021/nl802245w · Cited by 200
Nucleic acid aptamers for biosensors and bio-analytical applications
Sefah, K., Phillips, J. A., Xiong, X., Meng, L., Van Simaeys, D., Chen, H., Martin, J., & Tan, W. (2009) · The Analyst · doi:10.1039/b905609m · Cited by 194
Lee, J. F. (2004) · Nucleic Acids Research · doi:10.1093/nar/gkh094 · Cited by 188
Zhang, S., Xia, J., & Li, X. (2008) · Analytical Chemistry · doi:10.1021/ac800857p · Cited by 186
Aptamer-Based Au Nanoparticles-Enhanced Surface Plasmon Resonance Detection of Small Molecules
Wang, J., & Zhou, H. S. (2008) · Analytical Chemistry · doi:10.1021/ac801281c · Cited by 185
Recent Progress in Nucleic Acid Aptamer-Based Biosensors and Bioassays
Mok, W. W. K., & Li, Y. (2008) · Sensors · doi:10.3390/s8117050 · Cited by 142
Yoshida, W., Mochizuki, E., Takase, M., et al. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.06.016 · Cited by 141
A New Aptameric Biosensor for Cocaine Based on Surface‐Enhanced Raman Scattering Spectroscopy
Chen, J., Jiang, J., Gao, X. G., Liu, G., Shen, G., & Yu, R. (2008) · Chemistry - A European Journal · doi:10.1002/chem.200701307 · Cited by 139
Chen, J., Liu, X., Feng, K., Liang, Y., Jiang, J., Shen, G., & Yu, R. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.03.013 · Cited by 132
Wang, J., Meng, W., Zheng, X., Liu, S., & Li, G. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.08.030 · Cited by 130
A simple and direct electrochemical detection of interferon-γ using its RNA and DNA aptamers
Min, K., Cho, M., Han, S.-Y., Shim, Y., Ku, J., & Ban, C. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.02.021 · Cited by 111
Vicéns, M. C., Sen, A., Vanderlaan, A., Drake, T. J., & Tan, W. (2005) · ChemBioChem · doi:10.1002/cbic.200400308 · Cited by 76
Yoshizumi, J., Kumamoto, S., Nakamura, M., & Yamana, K. (2008) · The Analyst · doi:10.1039/b719089c · Cited by 61
Cited by
Aptamers and Their Biological Applications
Song, K.-M., Lee, S., & Ban, C. (2012) · Sensors · doi:10.3390/s120100612 · Cited by 821
Yu, H., Alkhamis, O., Canoura, J., Liu, Y., & Xiao, Y. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202008663 · Cited by 492
Noble metal nanoparticles in biosensors: recent studies and applications
Malekzad, H., Sahandi Zangabad, P., Mirshekari, H., Karimi, M., & Hamblin, M. R. (2017) · Nanotechnology Reviews · doi:10.1515/ntrev-2016-0014 · Cited by 375
Electrochemical biosensors for the detection of lung cancer biomarkers: A review
Khanmohammadi, A., Aghaie, A., Vahedi, E., Qazvini, A., Ghanei, M., Afkhami, A., Hajian, A., & Bagheri, H. (2020) · Talanta · doi:10.1016/j.talanta.2019.120251 · Cited by 358
Upconversion nanoparticles based FRET aptasensor for rapid and ultrasenstive bacteria detection
Jin, B., Wang, S., Lin, M., Jin, Y., Zhang, S., Cui, X., Gong, Y., Li, A., Xu, F., & Lu, T. J. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.10.029 · Cited by 341
Metadata
- Authors
- Han, K., Liang, Z., & Zhou, N.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2010-05-04
- Volume
- 10
- Issue
- 5
- Pages
- 4541-4557
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W1983054997
- Cited by
- 264
- References
- 39
- FWCI
- 3.31
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.