The DOI matches its Crossref record; 158 of the 158 references it cites were found in a registry or an index.
A Review of Non-Invasive Techniques to Detect and Predict Localised Muscle Fatigue
Open accessAbstract
Muscle fatigue is an established area of research and various types of muscle fatigue have been investigated in order to fully understand the condition. This paper gives an overview of the various non-invasive techniques available for use in automated fatigue detection, such as mechanomyography, electromyography, near-infrared spectroscopy and ultrasound for both isometric and non-isometric contractions. Various signal analysis methods are compared by illustrating their applicability in real-time settings. This paper will be of interest to researchers who wish to select the most appropriate methodology for research on muscle fatigue detection or prediction, or for the development of devices that can be used in, e.g., sports scenarios to improve performance or prevent injury. To date, research on localised muscle fatigue focuses mainly on the clinical side. There is very little research carried out on the implementation of detecting/predicting fatigue using an autonomous system, although recent research on automating the process of localised muscle fatigue detection/prediction shows promising results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Holland, J. H. (1992) · The MIT Press eBooks · doi:10.7551/mitpress/1090.001.0001 · Cited by 47,002
Fuzzy identification of systems and its applications to modeling and control
Takagi, T., & Sugeno, M. (1985) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1985.6313399 · Cited by 19,592
Genetic Algorithms + Data Structures = Evolution Programs
Michalewicz, Z. (1992) · Artificial Intelligence · doi:10.1007/978-3-662-02830-8 · Cited by 11,553
Genetic Algorithms + Data Structures = Evolution Programs
Michalewicz, Z. (1996) · Springer eBooks · doi:10.1007/978-3-662-03315-9 · Cited by 5,095
A Practical Guide to Support Vector Classication
Hsu, C., Chang, C.-C., & Lin, C. (2008) · Cited by 5,046
Perceived exertion as an indicator of somatic stress
Borg, G. (1970) · Journal of Rehabilitation Medicine · doi:10.2340/1650197719702239298 · Cited by 4,707
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268
(2009) · Encyclopedia of Neuroscience · doi:10.1007/978-3-540-29678-2_6014 · Cited by 2,850
Support Vector Machines for Classification and Regression
Gunn, S. R. (1998) · Cited by 2,820
Muscles Alive—their functions revealed by electromyography
(1963) · Postgraduate Medical Journal · doi:10.1136/pgmj.39.449.162-b · Cited by 1,772
Davis, H. S. (1966) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1966.03100200106038 · Cited by 1,719
Techniques of EMG signal analysis: detection, processing, classification and applications
Reaz, M. B. I., Hussain, M. S., & Mohd-Yasin, F. (2006) · Biological Procedures Online · doi:10.1251/bpo115 · Cited by 1,629
The extraction of neural strategies from the surface EMG
Farina, D., Merletti, R., & Enoka, R. M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01070.2003 · Cited by 1,573
Neurobiology of muscle fatigue
Enoka, R. M., & Stuart, D. G. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.72.5.1631 · Cited by 1,429
Electromyography: Physiology, Engineering, and Noninvasive Applications
(2004) · Wiley eBooks · doi:10.1002/0471678384 · Cited by 1,151
Some new indexes of cluster validity
Bezdek, J. C., & Pal, N. R. (1998) · IEEE Transactions on Systems, Man and Cybernetics, Part B (Cybernetics) · doi:10.1109/3477.678624 · Cited by 1,132
Changes in muscle contractile properties and neural control during human muscular fatigue
Bigland‐Ritchie, B., & Woods, J. J. (1984) · Muscle & Nerve · doi:10.1002/mus.880070902 · Cited by 1,050
AGE‐RELATED CHANGES IN THE STRUCTURE AND FUNCTION OF SKELETAL MUSCLES
Faulkner, J. A., Larkin, L. M., Claflin, D. R., & Brooks, S. V. (2007) · Clinical and Experimental Pharmacology and Physiology · doi:10.1111/j.1440-1681.2007.04752.x · Cited by 759
Physiology and Mathematics of Myoelectric Signals
De Luca, C. J. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326534 · Cited by 684
Validation of near-infrared spectroscopy in humans
Mancini, D. M., Bolinger, L., Li, H., Kendrick, K., Chance, B., & Wilson, J. R. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2740 · Cited by 669
A method for positioning electrodes during surface EMG recordings in lower limb muscles
Rainoldi, A., Melchiorri, G., & Caruso, I. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.014 · Cited by 610
Kaplan, E. (1962) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-196244060-00031 · Cited by 589
Fatigue of intermittent submaximal voluntary contractions: central and peripheral factors
Bigland-Ritchie, B., Furbush, F., & Woods, J. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.2.421 · Cited by 544
A Primer on Wavelets and Their Scientific Applications
Walker, J. S. (2021) · CRC Press eBooks · doi:10.1201/9781420050011 · Cited by 524
Muscle sound: bases for the introduction of a mechanomyographic signal in muscle studies.
Orizio, C. (1993) · PubMed · Cited by 523
EMG frequency spectrum, muscle structure, and fatigue during dynamic contractions in man
Komi, P. V., & Tesch, P. (1979) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421103 · Cited by 461
Muscle blood flow during isometric activity and its relation to muscle fatigue
Sj�gaard, G., Savard, G., & Juel, C. (1988) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00635992 · Cited by 422
Evaluation of the forearm EMG signal features for the control of a prosthetic hand
Boostani, R., & Moradi, M. H. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/307 · Cited by 391
Motor unit physiology: Some unresolved issues
Enoka, R. M., & Fuglevand, A. J. (2001) · Muscle & Nerve · doi:10.1002/1097-4598(200101)24:1<4::aid-mus13>3.0.co;2-f · Cited by 390
Influence of amplitude cancellation on the simulated surface electromyogram
Keenan, K. G., Farina, D., Maluf, K. S., Merletti, R., & Enoka, R. M. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00894.2004 · Cited by 389
Fuzzy EMG classification for prosthesis control
Chan, F. H. Y., Yang, Y.-S., Lam, F. K., Zhang, Y.-T., & Parker, P. A. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.867872 · Cited by 376
Changes in surface EMG parameters during static and dynamic fatiguing contractions
Masuda, K., Masuda, T., Sadoyama, T., Inaki, M., & Katsuta, S. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00021-2 · Cited by 375
Time-frequency analysis of myoelectric signals during dynamic contractions: a comparative study
Karlsson, S., Yu, J., & Akay, M. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.821766 · Cited by 358
Functional Separation of EMG Signals via ARMA Identification Methods for Prosthesis Control Purposes
Graupe, D., & Cline, W. K. (1975) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1975.5408479 · Cited by 354
The Role of Fatigue in Susceptibility to Acute Muscle Strain Injury
Mair, S. D., Seaber, A. V., Glisson, R. R., & Garrett, W. E. (1996) · The American Journal of Sports Medicine · doi:10.1177/036354659602400203 · Cited by 352
Localized muscle fatigue--definiton and measurement.
Chaffin, D. B. (1973) · PubMed · Cited by 330
Surface Electromyography for Noninvasive Characterization of Muscle
Merletti, R., Rainoldi, A., & Farina, D. (2001) · Exercise and Sport Sciences Reviews · doi:10.1097/00003677-200101000-00005 · Cited by 325
Interpretation of the Surface Electromyogram in Dynamic Contractions
Farina, D. (2006) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-200607000-00006 · Cited by 324
The Effect of Lumbar Fatigue on the Ability to Sense a Change in Lumbar Position: A Controlled Study
Taimela, S., Kankaanpää, M., & Luoto, S. (1999) · Spine · doi:10.1097/00007632-199907010-00009 · Cited by 310
Signal characteristics of EMG during fatigue
Viitasalo, J. H. T., & Komi, P. V. (1977) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421697 · Cited by 295
The linear electrode array: a useful tool with many applications
Merletti, R., Farina, D., & Gazzoni, M. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00082-2 · Cited by 285
Cramer, J. T., Housh, T. J., Weir, J. P., Johnson, G. O., Coburn, J. W., & Beck, T. W. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1199-x · Cited by 285
Differences in quadriceps muscle strength and fatigue between lean and obese subjects
Maffiuletti, N. A., Jubeau, M., Munzinger, U., Bizzini, M., Agosti, F., De Col, A., Lafortuna, C. L., & Sartorio, A. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0471-2 · Cited by 284
Bonato, P., Roy, S. H., Knaflitz, M., & de Luca, C. J. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.930899 · Cited by 284
Extra- and intracellular water spaces in muscles of man at rest and with dynamic exercise
Sjogaard, G., & Saltin, B. (1982) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1982.243.3.r271 · Cited by 275
Orizio, C., Gobbo, M., Diemont, B., Esposito, F., & Veicsteinas, A. (2003) · European Journal of Applied Physiology · doi:10.1007/s00421-003-0924-1 · Cited by 260
Effects of electrode location on myoelectric conduction velocity and median frequency estimates
Roy, S. H., De Luca, C. J., & Schneider, J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.4.1510 · Cited by 260
Oxidative metabolism in muscle
Ferrari, M., Binzoni, T., & Quaresima, V. (1997) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1997.0049 · Cited by 247
Supraspinal fatigue during intermittent maximal voluntary contractions of the human elbow flexors
Taylor, J. L., Allen, G. M., Butler, J. E., & Gandevia, S. C. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.89.1.305 · Cited by 246
Jensen, C., Vasseljen, O., & Westgaard, R. H. (1993) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00864227 · Cited by 240
EMG signal classification for human computer interaction: a review
Ahsan, M. R., Ibrahimy, M. I., & Khalifa, O. O. (2009) · Cited by 238
Yoshitake, Y., Ue, H., Miyazaki, M., & Moritani, T. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210170001 · Cited by 213
The neurobiology of muscle fatigue: 15 years later
Barry, B. K., & Enoka, R. M. (2007) · Integrative and Comparative Biology · doi:10.1093/icb/icm047 · Cited by 212
Acoustic myography: A noninvasive monitor of motor unit fatigue
Barry, D. T., Geiringer, S. R., & Ball, R. D. (1985) · Muscle & Nerve · doi:10.1002/mus.880080303 · Cited by 208
PETROFSKY, J. S., GLASER, R. M., PHILLIPS, C. A., LIND, A. R., & WILLIAMS, C. (1982) · Ergonomics · doi:10.1080/00140138208924942 · Cited by 207
Evidence for neuromuscular fatigue during high-intensity cycling in warm, humid conditions
Kay, D., Marino, F. E., Cannon, J., St Clair Gibson, A., Lambert, M. I., & Noakes, T. D. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210000340 · Cited by 206
The effect of training on strength and endurance of the diaphragm in quadriplegia
Gross, D., Ladd, H. W., Riley, E. J., Macklem, P. T., & Grassino, A. (1980) · The American Journal of Medicine · doi:10.1016/0002-9343(80)90157-6 · Cited by 203
The sounds from single motor units in a contracting muscle
Gordon, G., & Holbourn, A. H. S. (1948) · The Journal of Physiology · doi:10.1113/jphysiol.1948.sp004290 · Cited by 199
Is independence good for combining classifiers?
Kuncheva, L. I., Whitaker, C. J., Shipp, C. A., & Duin, R. P. W. (2002) · Proceedings 15th International Conference on Pattern Recognition. ICPR-2000 · doi:10.1109/icpr.2000.906041 · Cited by 194
Geometrical factors in surface EMG of the vastus medialis and lateralis muscles
Rainoldi, A., Nazzaro, M., Merletti, R., Farina, D., Caruso, I., & Gaudenti, S. (2000) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00024-9 · Cited by 192 · cited 1×
“The area where nerve terminations and muscles connect is known as the innervation zone (IZ) [44].”
BackgroundBeck, T. W., Housh, T. J., Cramer, J. T., Weir, J. P., Johnson, G. O., Coburn, J. W., Malek, M. H., & Mielke, M. (2005) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-4-67 · Cited by 192
Work load and fatigue in repetitive arm elevations
HAGBERG, M. (1981) · Ergonomics · doi:10.1080/00140138108924875 · Cited by 183
Zheng, Y. P., Chan, M. M. F., Shi, J., Chen, X., & Huang, Q. H. (2006) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2005.07.012 · Cited by 181
Wavelet analysis of surface electromyography
Kumar, D., Pah, N. D., & Bradley, A. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.819901 · Cited by 180
Muscle Fatigue during Dynamic Contractions Assessed by New Spectral Indices
DIMITROV, G. V., ARABADZHIEV, T. I., MILEVA, K. N., BOWTELL, J. L., CRICHTON, N., & DIMITROVA, N. A. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000233794.31659.6d · Cited by 174
Farina, D., Madeleine, P., Graven-Nielsen, T., Merletti, R., & Arendt-Nielsen, L. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-001-0574-0 · Cited by 168
Real-time intelligent pattern recognition algorithm for surface EMG signals
Khezri, M., & Jahed, M. (2007) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-6-45 · Cited by 166
Development of a myoelectric discrimination system for a multi-degree prosthetic hand
Huang, H.-P., & Chen, C.-Y. (2003) · Proceedings 1999 IEEE International Conference on Robotics and Automation (Cat. No.99CH36288C) · doi:10.1109/robot.1999.770463 · Cited by 162
Subjective and objective evaluation of shoulder muscle fatigue
Öberg, T., SANDSJö, L., & KADEFORS, R. (1994) · Ergonomics · doi:10.1080/00140139408964911 · Cited by 158
Reliability of surface electromyographic measurements
Kollmitzer, J., Ebenbichler, G. R., & Kopf, A. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00050-9 · Cited by 158
Electromyography in ergonomics
Kumar, S. (2017) · Routledge eBooks · doi:10.1201/9780203758670-1 · Cited by 155
Nordlund, M. M., Thorstensson, A., & Cresswell, A. G. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00650.2003 · Cited by 154
Duchêne, J., & Goubel, F. (1993) · PubMed · Cited by 149
Dedering, Å., Németh, G., & Harms‐Ringdahl, K. (1999) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00053-9 · Cited by 148
Electromyography in the biomechanical analysis of human movement and its clinical application
Kleissen, R. F. M., Buurke, J. H., Harlaar, J., & Zilvold, G. (1998) · Gait & Posture · doi:10.1016/s0966-6362(98)00025-3 · Cited by 142
Gamet, D., & Maton, B. (1989) · European Journal of Applied Physiology · doi:10.1007/bf00643510 · Cited by 140
Akataki, K., Mita, K., Watakabe, M., & Itoh, K. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210000321 · Cited by 135
Maton, B., & Gamet, D. (1989) · European Journal of Applied Physiology · doi:10.1007/bf00643511 · Cited by 135
The mussel pump: properties and modeling
Jørgensen, C., Larsen, P. S., Møhlenberg, F., & Riisgård, H. U. (1988) · Marine Ecology Progress Series · doi:10.3354/meps045205 · Cited by 131
Kanosue, K., Yoshida, M., Akazawa, K., & FUJII, K. (1979) · The Japanese Journal of Physiology · doi:10.2170/jjphysiol.29.427 · Cited by 130
Assessment of low back muscle fatigue by surface EMG signal analysis: methodological aspects
Farina, D., Gazzoni, M., & Merletti, R. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(03)00040-3 · Cited by 126
Beck, T. W., Housh, T. J., Johnson, G. O., Weir, J. P., Cramer, J. T., Coburn, J. W., & Malek, M. H. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.03.001 · Cited by 124
Karlsson, S., Yu, J., & Akay, M. (1999) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.764944 · Cited by 122
Hefftner, G., Zucchini, W., & Jaros, G. G. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.1370 · Cited by 120
Arm positioning in manual tasks An electromyographic study of localized muscle fatigue
Herberts, P., Kadefors, R., & Broman, H. (1980) · Ergonomics · doi:10.1080/00140138008924780 · Cited by 116
A Discrete-Time Model of Electrcally Stimulated Muscle
Bernotas, L. A., Crago, P. E., & Chizeck, H. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325776 · Cited by 114
Biomechanical Evaluation of Movement in Sport and Exercise
(2007) · Routledge eBooks · doi:10.4324/9780203935750 · Cited by 111
Neurobiology of Muscle Fatigue
Gandevia, S. C., Enoka, R. M., McComas, A. J., Stuart, D. G., & Thomas, C. K. (1995) · Advances in experimental medicine and biology · doi:10.1007/978-1-4899-1016-5_39 · Cited by 106
EMG assessment of back muscle function during cyclical lifting
Roy, S. H., Bonato, P., & Knaflitz, M. (1998) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00010-8 · Cited by 105
Muscle oxygen consumption, determined by NIRS, in relation to external force and EMG
Praagman, M., Veeger, H. E. J., Chadwick, E. K., Colier, W. N. J. M., & van der Helm, F. C. T. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00081-2 · Cited by 105
Mechanical behaviour of condenser microphone in mechanomyography
Watakabe, M., Mita, K., Akataki, K., & Itoh, Y. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344804 · Cited by 101
MMG and EMG responses during fatiguing isokinetic muscle contractions at different velocities
Perry‐Rana, S. R., Housh, T. J., Johnson, G. O., Bull, A. J., Berning, J. M., & Cramer, J. T. (2002) · Muscle & Nerve · doi:10.1002/mus.10214 · Cited by 101
Biceps brachii myoelectric and oxygenation changes during static and sinusoidal isometric exercises
Felici, F., Quaresima, V., Fattorini, L., Sbriccoli, P., Filligoi, G. C., & Ferrari, M. (2007) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.07.010 · Cited by 100
Skeletal muscle properties and fatigue resistance in relation to smoking history
Wüst, R. C. I., Morse, C. I., de Haan, A., Rittweger, J., Jones, D. A., & Degens, H. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0792-9 · Cited by 100
Carbohydrates, Branched-Chain Amino Acids, and Endurances: The Central Fatigue Hypothesis
Davis, J. M. (1995) · International Journal of Sport Nutrition · doi:10.1123/ijsn.5.s1.s29 · Cited by 97
Kankaanp, M. J., TAIMELA, S. P., Webber, C. L., Airaksinen, O., & H�nninen, O. (1997) · European Journal of Applied Physiology · doi:10.1007/s004210050242 · Cited by 97
Madeleine, P., Jørgensen, V., Søgaard, K., Arendt‐Nielsen, L., & Sjøgaard, G. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0578-4 · Cited by 95
Acquisition, Processing and Analysis of the Surface Electromyogram
Gerdle, B. U. C., Karlsson, S. J., Day, S. J., & Djupsjöbacka, M. (1999) · Springer eBooks · doi:10.1007/978-3-642-58552-4_26 · Cited by 92
Blind Separation of Linear Instantaneous Mixtures of Nonstationary Surface Myoelectric Signals
Farina, D., Févotte, C., Doncarli, C., & Merletti, R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.828048 · Cited by 88
Cheron, G. A., Draye, J.-P., Bourgeios, M., & Libert, G. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.488803 · Cited by 86
EMG analysis of shoulder muscle fatigue during resisted isometric shoulder elevation
Minning, S., Eliot, C. A., Uhl, T. L., & Malone, T. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.01.008 · Cited by 83
Firing rates of motor units during strong dynamic contractions
del Valle, A., & Thomas, C. K. (2005) · Muscle & Nerve · doi:10.1002/mus.20371 · Cited by 79
Loss of power during fatigue of human leg muscles.
James, C.-A., Sacco, P., & Jones, D. A. (1995) · The Journal of Physiology · doi:10.1113/jphysiol.1995.sp020661 · Cited by 77
Perry, S. R., Housh, T. J., Weir, J. P., Johnson, G. O., Bull, A. J., & Ebersole, K. T. (2001) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(00)00057-2 · Cited by 76
Adapting k-means for supervised clustering
Al-Harbi, S. H., & Rayward-Smith, V. J. (2006) · Applied Intelligence · doi:10.1007/s10489-006-8513-8 · Cited by 76
Dynamic monitoring of forearm muscles using one-dimensional sonomyography system
Guo, J., Zheng, Y.-P., Huang, Q.-H., & Chen, X. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.02.0026 · Cited by 74
Mechanomyography of the human quadriceps muscle during incremental cycle ergometry
Shinohara, M., Kouzaki, M., Yoshihisa, T., & Fukunaga, T. (1997) · European Journal of Applied Physiology · doi:10.1007/s004210050254 · Cited by 74
Ravier, P., Buttelli, O., Jennane, R., & Couratier, P. (2004) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2004.08.008 · Cited by 74
Age‐related muscle fatigue after a low‐force fatiguing contraction is explained by central fatigue
Yoon, T., Schlinder-Delap, B., Griffith, E. E., & Hunter, S. K. (2008) · Muscle & Nerve · doi:10.1002/mus.20969 · Cited by 72
Muthalib, M., Millet, G. Y., Quaresima, V., & Nosaka, K. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3309746 · Cited by 71
Dimitrov, G. V., Dißelhorst-Klug, C., Dimitrova, N. A., et al. (2003) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(02)00095-0 · Cited by 69
Dalton, P. A., & Stokes, M. J. (1991) · European Journal of Applied Physiology · doi:10.1007/bf00868071 · Cited by 67
Vibrations and sounds from evoked muscle twitches.
Barry, D. T. (1992) · PubMed · Cited by 65
Vedsted, P., Blangsted, A. K., Søgaard, K., Orizio, C., & Sjøgaard, G. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1216-0 · Cited by 62
Raikova, R., & Aladjov, H. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00031-3 · Cited by 62
Dimitrova, N. A., Arabadzhiev, T. I., Hogrel, J., & Dimitrov, G. V. (2007) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.08.007 · Cited by 61
Evetovich, T. K., Housh, T. J., Johnson, G. O., Smith, D. B., Ebersole, K. T., & Perry, S. R. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199812000-00007 · Cited by 60
Dalton, P. A., & Stokes, M. J. (1993) · Muscle & Nerve · doi:10.1002/mus.880160303 · Cited by 58
Calder, K. M., Stashuk, D. W., & McLean, L. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.08.012 · Cited by 56
Technical aspects of mechnomyography recording with piezoelectric contact sensor
Watakabe, M., Itoh, Y., Mita, K., & Akataki, K. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02524423 · Cited by 54
sEMG wavelet-based indices predicts muscle power loss during dynamic contractions
González‐Izal, M., Rodríguez, I., Malanda, A., Mallor, F., Navarro-Amézqueta, I., Gorostiaga, E. M., & Izquierdo, M. (2010) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2010.05.010 · Cited by 54
Rudroff, T., Staudenmann, D., & Enoka, R. M. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01058.2007 · Cited by 53
Morana, C., Ramdani, S., Perrey, S., & Varray, A. L. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.09.023 · Cited by 51
Effects of muscle perfusion pressure on fatigue and systemic arterial pressure in human subjects
Wright, J. R., McCloskey, D. I., & Fitzpatrick, R. C. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.3.845 · Cited by 51
Shi, J., Chang, Q., & Zheng, Y. (2010) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2009.03.0031 · Cited by 51
Mechanomyography and oxygen consumption during incremental cycle ergometry
Stout, J. R., Housh, T. J., Johnson, G. O., Evetovich, T. K., & Smith, D. B. (1997) · European Journal of Applied Physiology · doi:10.1007/s004210050262 · Cited by 50
Time-frequency analysis of skeletal muscle and cardiac vibrations
Wood, J. C., & Barry, D. T. (1996) · Proceedings of the IEEE · doi:10.1109/5.535246 · Cited by 50
Effects of postural muscle fatigue on the relation between segmental posture and movement
Chabran, E., Maton, B., & Fourment, A. (2002) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(01)00027-x · Cited by 49
Dynamic muscle fatigue detection using self-organizing maps
Moshou, D., Hostens, I., Papaioannou, G., & Ramón, H. (2004) · Applied Soft Computing · doi:10.1016/j.asoc.2004.09.001 · Cited by 49
Multifractal analysis of surface EMG signals for assessing muscle fatigue during static contractions
Wang, G., Ren, X., Li, L., & Zhi-zhong, W. (2007) · Journal of Zhejiang University. Science A · doi:10.1631/jzus.2007.a0910 · Cited by 47
Surface mechanomyogram amplitude is not attenuated by intramuscular pressure
Søgaard, K., Orizio, C., & Sjøgaard, G. (2004) · European Journal of Applied Physiology · doi:10.1007/s00421-004-1211-5 · Cited by 46
EMG-based measures of fatigue during a repetitive squat exercise
Bonato, P., Heng, M. S. S., González-Cueto, J. A., et al. (2001) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.982285 · Cited by 45
Oskoei, M. A., Hu, H., & Gan, J. Q. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649153 · Cited by 45
Tw, B., Housh, T. J., Johnson, G. O., Weir, J. P., Cramer, J. T., Coburn, J. W., & Malek, M. H. (2004) · PubMed · Cited by 45
MMG and EMG Responses during 25 Maximal, Eccentric, Isokinetic Muscle Actions
Perry‐Rana, S. R., Housh, T. J., Johnson, G. O., Bull, A. J., & Cramer, J. T. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000099090.73560.77 · Cited by 44
Zhang, Z. G., Liu, H. T., Chan, S. C., Luk, K. D. K., & Hu, Y. S. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2008.09.007 · Cited by 42
Acoustic myography compared to electromyography during isometric fatigue and recovery
Rodriquez, A. A., Agre, J. C., Knudtson, E. R., Cota, Franke, T. M., & Ng, A. V. (1993) · Muscle & Nerve · doi:10.1002/mus.880160212 · Cited by 42
AlZahrani, E. M., Gunasekaran, C., Callaghan, M. J., Gaydecki, P. A., Benítez, D. S., & Oldham, J. A. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.12.007 · Cited by 41
Kawczyński, A., Nie, H., Jaskólska, A., Jaskólski, A., Arendt‐Nielsen, L., & Madeleine, P. (2006) · Scandinavian Journal of Medicine and Science in Sports · doi:10.1111/j.1600-0838.2006.00551.x · Cited by 39
Cramer, J. T., Housh, T. J., Evetovich, T. K., et al. (2001) · European Journal of Applied Physiology · doi:10.1007/s00421-001-0529-5 · Cited by 38
Coorevits, P. L., Danneels, L. A., Cambier, D. C., et al. (2008) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2007.01.006 · Cited by 37
Perry, S. R., Housh, T. J., Johnson, G. O., Ebersole, K. T., Bull, A. J., Evetovich, T. K., & Smith, D. B. (2001) · PubMed · Cited by 33
Jaskólska, A., Madeleine, P., Jaskólski, A., Kisiel‐Sajewicz, K., & Arendt‐Nielsen, L. (2006) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2006.04.002 · Cited by 32
Electromyographic Analysis of Muscle Fatigue in Anterior Cruciate Ligament Deficient Knees
Tho, K. S., meth, G. N., Lamontagne, M., & Eriksson, E. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199707000-00018 · Cited by 30
Avaliação da fadiga muscular pela mecanomiografia durante a aplicação de um protocolo de EENM
Faller, L., Neto, G. N. N., Button, V. L. S. N., & Nohama, P. (2009) · Brazilian Journal of Physical Therapy · doi:10.1590/s1413-35552009005000057 · Cited by 29
Strategies to identify changes in SEMG due to muscle fatigue during cycling
Singh, V. P., Kumar, D., Polus, B., & Fraser, S. F. (2007) · Journal of Medical Engineering & Technology · doi:10.1080/03091900500444281 · Cited by 29
Effect of innervation‐zone distribution on estimates of average muscle‐fiber conduction velocity
Nielsen, M., Graven‐Nielsen, T., & Farina, D. (2007) · Muscle & Nerve · doi:10.1002/mus.20895 · Cited by 24
Surface electromyography and mechanomyography recording: A new differential composite probe
Gregori, B., Galiè, E., & Accornero, N. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02349974 · Cited by 23
Kim, J.-Y., Jung, M., & Haight, J. M. (2004) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2004.08.011 · Cited by 22
Time‐frequency analysis of mechanomyogram during sustained contractions with muscle fatigue
Itoh, Y., Akataki, K., Mita, K., Watakabe, M., & Itoh, K. (2003) · Systems and Computers in Japan · doi:10.1002/scj.10528 · Cited by 22
Relationships between muscle fatigue characteristics and markers of endurance performance.
Morris, M. G., Dawes, H., Howells, K., Scott, O. M., & Cramp, M. (2008) · Europe PMC (PubMed Central) · Cited by 22
Investigation on parametric analysis of dynamic EMG signals by a muscle-structured simulation model
Kiryu, T., Saitoh, Y., & Ishioka, K. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.125013 · Cited by 21
Real-time measurement of muscle fatigue related changes in surface EMG
Kramer, C. G. S., Hagg, T., & Kemp, B. (1987) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447329 · Cited by 20
A Finite-Element Analysis of the Effect of Muscle Insulation and Shielding on the Surface EMG Signal
Stoykov, N. S., Lowery, M. M., & Kuiken, T. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.834280 · Cited by 20
Hermans, V., Spaepen, A. J., & Wouters, M. (1999) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(98)00047-9 · Cited by 15
Gender differences in spectral and entropic measures of erector spinae muscle fatigue.
Sung, P. S., Zürcher, U., & Kaufman, M. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.11.0196 · Cited by 14
Mechanomyogram and electromyogram analyses during isometric contraction in human masseter muscle
Ioi, H., Kawakatsu, M., Nakata, S., Nakasima, A., & Counts, A. L. (2008) · Australasian Orthodontic Journal · doi:10.2478/aoj-2008-0017 · Cited by 14
Gender Difference in Subjective Muscle-fatigue Sensation during Sustained Muscle Force Exertion
Demura, S., Nakada, M., & Nagasawa, Y. (2008) · The Tohoku Journal of Experimental Medicine · doi:10.1620/tjem.215.287 · Cited by 10
Cited by
Surface Electromyography Signal Processing and Classification Techniques
Chowdhury, R., Reaz, M., Ali, M., Bakar, A., Chellappan, K., & Chang, T. (2013) · Sensors · doi:10.3390/s130912431 · Cited by 1,000
Deep Learning for EMG-based Human-Machine Interaction: A Review
Xiong, D., Zhang, D., Zhao, X., & Zhao, Y. (2021) · IEEE/CAA Journal of Automatica Sinica · doi:10.1109/jas.2021.1003865 · Cited by 395
A Review of Classification Techniques of EMG Signals during Isotonic and Isometric Contractions
Nazmi, N., Abdul Rahman, M., Yamamoto, S.-I., Ahmad, S., Zamzuri, H., & Mazlan, S. (2016) · Sensors · doi:10.3390/s16081304 · Cited by 377
Fatigue in Healthy and Diseased Individuals
Finsterer, J., & Mahjoub, S. Z. (2014) · American Journal of Hospice and Palliative Medicine® · doi:10.1177/1049909113494748 · Cited by 363
Wearable and Flexible Textile Electrodes for Biopotential Signal Monitoring: A review
Acar, G., Ozturk, O., Golparvar, A. J., Elboshra, T. A., Böhringer, K., & Yapici, M. K. (2019) · Electronics · doi:10.3390/electronics8050479 · Cited by 315
Metadata
- Authors
- Al-Mulla, M. R., Sepulveda, F., & Colley, M.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2011-03-24
- Volume
- 11
- Issue
- 4
- Pages
- 3545-3594
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2139354825
- Cited by
- 310
- References
- 158
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.