The DOI matches its Crossref record; 149 of the 149 references it cites were found in a registry or an index.
The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases.
Open accessAbstract
Bioimpedance analysis is a noninvasive, low cost and a commonly used approach for body composition measurements and assessment of clinical condition. There are a variety of methods applied for interpretation of measured bioimpedance data and a wide range of utilizations of bioimpedance in body composition estimation and evaluation of clinical status. This paper reviews the main concepts of bioimpedance measurement techniques including the frequency based, the allocation based, bioimpedance vector analysis and the real time bioimpedance analysis systems. Commonly used prediction equations for body composition assessment and influence of anthropometric measurements, gender, ethnic groups, postures, measurements protocols and electrode artifacts in estimated values are also discussed. In addition, this paper also contributes to the deliberations of bioimpedance analysis assessment of abnormal loss in lean body mass and unbalanced shift in body fluids and to the summary of diagnostic usage in different kinds of conditions such as cardiac, pulmonary, renal, and neural and infection diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“R of the conductor is expressed by R = ρL2/V, so V = ρL2/R, wherein ρ is the conductor resistivity, L is the length, and V is volume (48, 49).”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [49]
The cited source says what the claim attributes to it.
In the citing paper
“The electrical properties of the human body may explain the use of BIA to estimate FFM by the resistance index.”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [49]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200 · cited 25×
“At high frequencies, the current will pass through the whole TBW which is composed of ECF and ICF [96], so the conducting volume is equal to the ratio between TBW and total body volume.”
BackgroundMethodInfluentialESPEN Guidelines for Nutrition Screening 2002
Kondrup, J. (2003) · Clinical Nutrition · doi:10.1016/s0261-5614(03)00098-0 · Cited by 3,159
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Body mass index as a measure of body fatness: age- and sex-specific prediction formulas
Deurenberg, P., Weststrate, J., & Seidell, J. C. (1991) · British Journal of Nutrition · doi:10.1079/bjn19910073 · Cited by 1,397
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370 · cited 4×
“It was introduced by Hoofer [4] and later revised by Nyboer [3] to decrease the contact impedance between skin and electrodes, and validated by Lukaski [17] in 140 normal adults.”
MethodInfluentialBody composition of reference children from birth to age 10 years
Fomon, S. J., Haschke, F., Ziegler, E., & Nelson, S. (1982) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/35.5.1169 · Cited by 1,264
Bioimpedance and Bioelectricity Basics
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-06951-7 · Cited by 1,175
Norman, K., Stobäus, N., Pirlich, M., & Bosy-Westphal, A. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.05.008 · Cited by 1,049
Flagged first, then by citations
Research works printed but not linked: 3
- Thomasset, 1963, Bio-electrical properties of tissues, Lyon Med., 209, 1325
- Sargent, J.A., and Gotch, F.A. (1989). Replacement of Renal Function by Dialysis, Springer.
- Serrano, M.D.M., de Espinosa, M.G.-M., and Zamorano, E.M. (2012). Handbook of Anthropometry, Springer.
Cited by
Sorted by citations
Items 201–300 of 709
Textile electrodes for bioimpedance measuring
Meding, J. T., Tuvshinbayar, K., Döpke, C., & Tamoué, F. (2021) · Communications in development and assembling of textile products · doi:10.25367/cdatp.2021.2.p49-60 · Cited by 12
Costa, D., Muzzio, M., Saglietti, L., Budelli, S., González, C. L., Catena, E., Córsico, L., Iturralde, L. G., Esperón, G., Gregorietti, V., et al. (2020) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2020.09.119 · Cited by 11
Schotman, J. M., Rolleman, N., van Borren, M. M. G. J., Wetzels, J. F. M., Kloke, H. J., Reichert, L. J. M., & de Boer, H. (2021) · Journal of Renal Nutrition · doi:10.1053/j.jrn.2021.11.004 · Cited by 11
Delano, M. K., Ganapati, V., Kamal, R., Le, B., Le, J., & Mendoza, R. (2022) · Frontiers in Electronics · doi:10.3389/felec.2021.762442 · Cited by 11
Cleymaet, R., D'Hondt, M., Scheinok, T., Malbrain, L., laet, I. D., Schoonheydt, K., Dits, H., Regenmortel, N. V., Mekeirele, M., Cordemans, C., et al. (2023) · Life · doi:10.3390/life14010027 · Cited by 12
Janwadkar, S., & Dhavse, R. (2024) · Microprocessors and Microsystems · doi:10.1016/j.micpro.2024.105048 · Cited by 11
Assessment of Sarcopenia in Patients with Liver Cirrhosis—A Literature Review
Božić, D., Mamic, B., Perić, I., Božić, I., Žaja, I., Ivanović, T., Ratkovic, A. G., & Grgurević, I. (2025) · Nutrients · doi:10.3390/nu17162589 · Cited by 11
Auclair, A., Piché, M., Biertho, L. D., Marceau, S., & Poirier, P. (2020) · Surgery for Obesity and Related Diseases · doi:10.1016/j.soard.2020.03.012 · Cited by 11
Assessment of Malnutrition Status in Hemodialysis Patients
Zaki, D. S. D., Mohamed, R. R., Mohammed, N. A. G., & Abdel-Zaher, R. B. (2019) · Clinical Medicine and Diagnostics · Cited by 11
A Portable Sensor for Skin Bioimpedance Measurements
Harvey, J. R., & Mendelson, Y. (2019) · International Journal of Sensors and Sensor Networks · doi:10.11648/j.ijssn.20190701.11 · Cited by 11
Wireless Low–Cost Bioimpedance Measurement Device for Lung Capacity Screening
Pino, E. J., Gómez, B., Monsalve, E., & Aqueveque, P. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857387 · Cited by 11
Moura-Fernandes, M. C., Moreira-Marconi, E., de Meirelles, A. G., Reis-Silva, A., Ferreira-Souza, L. F., da Silva, A. L. P., de Oliveira, B. B. M., Gama, M. A. D. S., Coelho-Oliveira, A. C., Batouli-Santos, D., et al. (2020) · Applied Sciences · doi:10.3390/app10175870 · Cited by 11
Body Composition by Bioelectrical Impedance Analysis
González-Correa, C. H. (2018) · Springer eBooks · doi:10.1007/978-3-319-74388-2_11 · Cited by 11
Choi, H.-J., Ko, C.-Y., Chang, Y., Kim, G.-S., Choi, K., & Kim, C.-H. (2021) · PeerJ · doi:10.7717/peerj.10970 · Cited by 10
A Review of Engineering Approaches for Lymphedema Detection
Rincon, K., Shah, P., Ramella‐Roman, J. C., & Bhansali, S. (2016) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2016.2582178 · Cited by 10
Ali, Y., & Ali, T. (2021) · Burns · doi:10.1016/j.burns.2021.04.011 · Cited by 10
New App-Based Dietary and Lifestyle Intervention on Weight Loss and Cardiovascular Health
Martínez‐Rodríguez, A., Martínez-Olcina, M., Mora, J., Navarro, P., Caturla, N., & Jones, J. (2022) · Sensors · doi:10.3390/s22030768 · Cited by 12
Linsalata, M., Riezzo, G., Orlando, A., D’Attoma, B., Prospero, L., Ignazzi, A., Losurdo, G., Leo, A. D., Giannelli, G., & Russo, F. (2023) · Nutrients · doi:10.3390/nu15214683 · Cited by 10
A portable sensor system for bacterial concentration monitoring in metalworking fluids
Grossi, M., Parolin, C., Vitali, B., & Riccò, B. (2018) · Journal of sensors and sensor systems · doi:10.5194/jsss-7-349-2018 · Cited by 10
Невойт, Г. В., Потяженко, М. М., & Mintser, O. P. (2021) · World of Medicine and Biology · doi:10.26724/2079-8334-2021-3-77-132-137 · Cited by 10
Mitkin, N. A., Unguryanu, T. N., Malyutina, S. K., & Kudryavtsev, A. V. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20042905 · Cited by 10
Nescolarde, L., Pajares, V., Torregó, A., Riu, P. J., Rosell, J., & Bragós, R. (2023) · Frontiers in Medicine · doi:10.3389/fmed.2023.1108237 · Cited by 10
Nutritional physiology and body composition changes during a rapid ascent to high altitude
Santangelo, C., Verratti, V., Mrakic‐Sposta, S., Ciampini, F., Bonan, S., Pignatelli, P., Pietrangelo, T., Pilato, S., Moffa, S., Fontana, A., et al. (2024) · Applied Physiology Nutrition and Metabolism · doi:10.1139/apnm-2023-0338 · Cited by 10
Christidis, G., Küppers, F., Karataylı, S. C., Karataylı, E., Weber, S. N., Lammert, F., & Krawczyk, M. J. (2024) · BMC Endocrine Disorders · doi:10.1186/s12902-024-01558-9 · Cited by 10
Phase Angle Bioelectrical Impedance Analysis (BIA) as a Biomarker Tool for Liver Disease
Marroni, C. A., Miranda, D., Boemeke, L., & Fernandes, S. A. (2017) · Biomarkers in disease · doi:10.1007/978-94-007-7675-3_43 · Cited by 10
Mantzorou, M., Tolia, M., Poultsidi, A., Pavlidou, E., Papadopoulou, S. Κ., Papandreou, D., & Giaginis, C. (2020) · Cancers · doi:10.3390/cancers12030557 · Cited by 10
Prevalence of Overweight and Obesity among Primary Healthcare Workers In Perak, Malaysia
Kit, L. P., Saad, H. A., Jamaluddin, R., & Phing, C. H. (2020) · IIUM Medical Journal Malaysia · doi:10.31436/imjm.v19i1.1327 · Cited by 10
This Whole Thing Smacks of Gender
Albert, K., & Delano, M. K. (2021) · ACM Conference on Fairness, Accountability, and Transparency (FAccT) · doi:10.1145/3442188.3445898 · Cited by 14
Análisis de impedancia bioeléctrica (AIB) en la producción animal. Revisión
Schumacher, L. L., Viégas, J., Cardoso, G. D. S., Moro, A. B., Tonin, T. J., Pereira, S. N., da Rocha, L. T., Caeneghen, A. L. V., & Teixeira, J. V. (2021) · Revista Mexicana de Ciencias Pecuarias · doi:10.22319/rmcp.v12i2.5821 · Cited by 10
Majeed, M., Siddiqui, M., & Lessan, N. G. (2023) · BMC Endocrine Disorders · doi:10.1186/s12902-023-01405-3 · Cited by 9
Liu, S.-H., Sun, Y., Wu, B.-Y., Chen, W., & Zhu, X. (2025) · Frontiers in Digital Health · doi:10.3389/fdgth.2025.1511667 · Cited by 9
Niu, C., Zhang, P., Zhang, C., Dong, J., Liang, H., Xiao, D., Liu, B., Lan, W., Lai, H., Ye, J., et al. (2025) · Journal of the International Society of Sports Nutrition · doi:10.1080/15502783.2025.2523381 · Cited by 9
Sepulveda, R. A. Y., Vasquez-Bonilla, A. A., Olivares, R., Olivares, P., Zavala-Crichton, J. P., Hinojosa-Torres, C., Muñoz-Strale, C., Giakoni-Ramírez, F., de Souza-Lima, J., Páez‐Herrera, J., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-15264-6 · Cited by 12
Association of Bioimpedance Parameters with Increases in Blood Pressure during Hemodialysis
Elsayed, E., Farag, Y. M. K., Ravi, K. S., Chertow, G. M., & McCausland, F. R. (2023) · American Society of Nephrology. Clinical Journal · doi:10.2215/cjn.0000000000000356 · Cited by 10
Lee, S., Battumur, B., Lee, J. E., Park, S., Choi, Y., Kang, D. O., Park, E. J., Lee, D. I., Choi, J. Y., Roh, S. Y., et al. (2024) · International Journal of Cardiology · doi:10.1016/j.ijcard.2024.132205 · Cited by 9
David, M., Berkovich, U., & Pracca, F. (2017) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2017.8325053 · Cited by 9
Body composition measurements in paediatrics – a review. Part 1
Dobroch, J., Cieśluk, K., Sawicka-Żukowska, M., & Krawczuk‐Rybak, M. (2018) · Pediatric Endocrinology Diabetes and Metabolism · doi:10.5114/pedm.2018.83365 · Cited by 9
Roy, S., & Majumder, A. (2019) · Cureus · doi:10.7759/cureus.4674 · Cited by 9
Gaubert, V., Gidik, H., & Končar, V. (2020) · Sensors · doi:10.3390/s20143980 · Cited by 9
Muscle Mass Measurement Using Machine Learning Algorithms with Electrical Impedance Myography
Cheng, K., Su, Y., Kuo, L., Yang, T., Lee, C.-L., Chen, W., & Liu, S.-H. (2022) · Sensors · doi:10.3390/s22083087 · Cited by 9
Segmental Bioimpedance Variables in Association With Mild Cognitive Impairment
Doan, D. N. T., Ku, B. U., Kim, K., Jun, M., Choi, K. Y., Lee, K. H., & Kim, J. U. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.873623 · Cited by 10
Estimation of fluid status using three multifrequency bioimpedance methods in hemodialysis patients
Wang, L., Raimann, J. G., Tao, X., Preciado, P., Thwin, O., Rosales, L. M., Thijssen, S., Kotanko, P., & Zhu, F. (2022) · Hemodialysis International · doi:10.1111/hdi.13034 · Cited by 9
Electrical Impedance Analysis for Lung Cancer: A Prospective, Multicenter, Blind Validation Study
Yang, D., Gu, C., Gu, Y., Zhang, X., Ge, D., Zhang, Y., Wang, N., Zheng, X., Wang, H., Yang, L., et al. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.900110 · Cited by 9
Farokhi, F. R., Kalateh, E., Shafaghi, S., Schneider, A. G., Mortazavi, S. M., Jamaati, H., & Hashemian, S. M. R. (2022) · Journal of Critical Care · doi:10.1016/j.jcrc.2022.154146 · Cited by 9
Mondal, H., Mondal, S., & Baidya, C. (2019) · Journal of Education and Health Promotion · doi:10.4103/jehp.jehp_358_18 · Cited by 9
Timing, velocity, and magnitude of pubertal changes in body composition: a longitudinal study
Chun, D., Kim, S. J., Suh, J., & Kim, J. (2024) · Pediatric Research · doi:10.1038/s41390-024-03299-w · Cited by 8
Chun, D., Kim, S. J., Suh, J., & Kim, J. (2024) · BMC Pediatrics · doi:10.1186/s12887-024-05166-3 · Cited by 8
Bello, S. D., Ceccarelli, L., Tereshko, Y., Gigli, G. L., D’Anna, L., Valente, M., & Merlino, G. (2025) · Nutrients · doi:10.3390/nu17050919 · Cited by 8
Iftime, A., Scheau, C., Babeș, R.-M., Ionescu, D., Periferakis, A., & Călinescu, O. (2025) · Bioengineering · doi:10.3390/bioengineering12090926 · Cited by 9
Advancing physical activity monitoring through bioimpedance measurement: a review
Jacobs, I., Lowe, A., García, L., & Zhang, H. (2026) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae3671 · Cited by 8
Migdanis, A., Koukoulis, G., Mamaloudis, I., Baloyiannis, I., Migdanis, I., Vagena, X., Malissiova, E., & Tzovaras, G. (2020) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2020.08.002 · Cited by 8
Wells, A. D., Bellovary, B. N., Houck, J. M., Ducharme, J. B., Masoud, A. A., Gibson, A. L., & Mermier, C. M. (2020) · International journal of exercise science · doi:10.70252/dxjn8781 · Cited by 9
Assessment of uremic sarcopenia in dialysis patients
Lin, Y., & Hsu, B. (2022) · Tzu Chi Medical Journal · doi:10.4103/tcmj.tcmj_254_20 · Cited by 9
Analysis of tissue electrical properties on bio-impedance variation of upper limps
Salkım, E. (2022) · TURKISH JOURNAL OF ELECTRICAL ENGINEERING & COMPUTER SCIENCES · doi:10.55730/1300-0632.3908 · Cited by 8
Barry, V. G., Martin, S. L., Chandler-Laney, P. C., Carter, E. B., & Schneider, C. R. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192013636 · Cited by 8
Albano, D., Gitto, S., Vitale, J. A., Bernareggi, S., Aliprandi, A., Sconfienza, L. M., & Messina, C. (2022) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-022-05902-9 · Cited by 9
Considerations of the Genetic Background of Obesity among Patients with Psoriasis
Czarnecka, A., Purzycka-Bohdan, D., Zabłotna, M., Bohdan, M., Nowicki, R. J., & Szczerkowska‐Dobosz, A. (2023) · Genes · doi:10.3390/genes14030594 · Cited by 8
Guerrini, A., Siotto, M., Germanotta, M., Schirru, M., Pavan, A., Cipollini, V., Insalaco, S., & Aprile, I. G. (2023) · Applied Sciences · doi:10.3390/app13063965 · Cited by 8
Low, S. K., Pek, S. L. T., Moh, A. M. C., Khoo, J., Ang, K., Tang, W. E., Lim, Z., Subramaniam, T., Sum, C. F., & Lim, S. C. (2023) · Annals of the Academy of Medicine Singapore · doi:10.47102/annals-acadmedsg.2022350 · Cited by 8
Collaborative active learning: bioimpedance and anthropometry in higher education
Bravo, R., Ugartemendia, L., Juánez, J. C., Uguz, C., & Rodríguez, A. B. (2018) · AJP Advances in Physiology Education · doi:10.1152/advan.00106.2017 · Cited by 8
Neuls, F., Botek, M., Krejčí, J., Panská, S., Vyhnánek, J., & McKune, A. J. (2019) · Sport Sciences for Health · doi:10.1007/s11332-019-00539-z · Cited by 8
Howe, C. A., Corrigan, R. J., Djalali, M. A., McManaway, C., Grbcich, A., & Aidoo, G. S. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph181910094 · Cited by 8
Abboud, T., Mielke, D., & Rohde, V. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2021.825012 · Cited by 8
Poncumhak, P., Wiyanad, A., Siriyakul, C., Kosura, N., Amatachaya, P., & Amatachaya, S. (2022) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2021.2023931 · Cited by 8
Noninvasive health monitoring using bioelectrical impedance analysis
Aldobali, M., Pal, K., & Chhabra, H. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-99031-8.00008-9 · Cited by 11
Kerzérho, V., Azais, F., Bernard, S., Bonhommeau, S., Brisset, B., Knyff, L. D., Julien, M., Renovell, M., Rouyer, T., Saraux, C., et al. (2023) · Fishes · doi:10.3390/fishes8020088 · Cited by 8
Bioimpedance Vector Analysis in Diagnosing Severe and Non-Severe Dengue Patients
Khalil, S. F., Mohktar, M. S., & Ibrahim, F. (2016) · Sensors · doi:10.3390/s16060911 · Cited by 8
Chung, W., Silverio, A. A., Tsai, V. F. S., Cheng, C., Chang, S.-Y., Zhou, M.-Y., Chen, S., Kao, C.-Y., Rustia, D. J. A., & Lo, Y.-W. (2016) · Microelectronics Journal · doi:10.1016/j.mejo.2016.08.011 · Cited by 8
Development of Thermal Sensor by Reinforced Graphene Nanoplatelets Thermoplastic Blends
Sharma, A. K., Pandey, M., Khutia, M., Joshi, G. M., & Cuberes, M. T. (2016) · Polymer-Plastics Technology and Engineering · doi:10.1080/03602559.2016.1233272 · Cited by 8
Głąbska, D., Cackowska, K., & Guzek, D. (2018) · Medicina · doi:10.3390/medicina54060104 · Cited by 8
Phenotypic Aspects of Longevity
Accardi, G., Ligotti, M. E., & Candore, G. (2019) · Springer eBooks · doi:10.1007/978-3-030-20762-5_2 · Cited by 8
Yang, J., Yu, J., Kim, J., & Park, E. (2024) · Nutrients · doi:10.3390/nu16132136 · Cited by 7
Comparing Device-Generated and Calculated Bioimpedance Variables in Community-Dwelling Older Adults
Lafontant, K., Sterner, D. A., Fukuda, D. H., Stout, J. R., Park, J., & Thiamwong, L. (2024) · Sensors · doi:10.3390/s24175626 · Cited by 7
Wang, C., Zhang, Y., Lin, F., Li, Z., Ping, Z., Shi, Y., Chen, Y., Yu, M., Qin, W., Rong, Y., et al. (2025) · Scientific Reports · doi:10.1038/s41598-025-01166-0 · Cited by 7
Lee, D., Won, C. W., & Kim, M. (2025) · Aging Clinical and Experimental Research · doi:10.1007/s40520-025-03130-4 · Cited by 7
Wearable technologies in clinical trials for drug development: trends and emerging opportunities
Fayad, Z. A., Hirten, R. P., Nadkarni, G. N., & Kim, Y. (2026) · Nature Reviews Drug Discovery · doi:10.1038/s41573-026-01403-9 · Cited by 8
Ogawa, R., Akita, S., & Takei, M. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3220282 · Cited by 7
Bianco, A., Russo, F., Prospero, L., Riezzo, G., Franco, I., D’Attoma, B., Ignazzi, A., Verrelli, N., Bagnato, C. B., Goscilo, F., et al. (2024) · Nutrients · doi:10.3390/nu16234181 · Cited by 7
Noddeland, H., Bremnes, F., Thorud, A., Rolid, K., Kværness, J., Jaatun, E. A. A., & Aas, S. N. (2024) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-024-01245-z · Cited by 7
Monitoring breathing rate using bio-impedance technique
Potdar, S. V., Panditrao, A. M., & Khambete, N. D. (2016) · International Conference on Computing Communication Control and automation · doi:10.1109/iccubea.2016.7860143 · Cited by 7
Cavezzi, A., Urso, S. U., Paccasassi, S., Mosti, G. B., Campana, F., & Colucci, R. (2020) · Phlebology The Journal of Venous Disease · doi:10.1177/0268355520938578 · Cited by 7
Martín, P. B. P., Rodríguez, G. M. H., González-Martín, J. M., Perez‐Valera, M., & de Pablos-Velasco, P. L. (2020) · Academic Radiology · doi:10.1016/j.acra.2020.02.029 · Cited by 7
Pajek, M., Sember, V., Čuk, I., Šimenko, J., & Pajek, J. (2021) · Symmetry · doi:10.3390/sym13010150 · Cited by 7
de Melo, V. X., Mezzomo, T. R., Dall'igna, A. L. A., Dengo, V. D. A. M., Stangarlin‐Fiori, L., Schieferdecker, M. E. M., & Ferreira, S. M. R. (2022) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2022.03.042 · Cited by 7
Bertuccioli, A., Cardinali, M., & Benelli, P. (2022) · Life · doi:10.3390/life12071062 · Cited by 8
Design and Manufacturing of Equipment for Investigation of Low Frequency Bioimpedance
Pîslaru‐Dănescu, L., Zarnescu, G., Telipan, G., & Stoica, V. (2022) · Micromachines · doi:10.3390/mi13111858 · Cited by 7
Detection of stenosis in blood vessel by using bio-impedance analysis
Shash, Y. H., Eldosoky, M. A. A., & El-Wakad, M. T. (2018) · National Radio Science Conference · doi:10.1109/nrsc.2018.8354409 · Cited by 7
Jeong, I. S., Lee, E., Kim, J. H., Kim, G. H., Hwang, Y. J., & Jeon, G. R. (2019) · PLoS ONE · doi:10.1371/journal.pone.0213585 · Cited by 7
Li, Y., Ma, R., Wang, X., Jin, J., Wang, H., Liu, Z., & Yin, T. (2019) · Journal of Applied Biomedicine · doi:10.1016/j.bbe.2019.08.003 · Cited by 7
Non-invasive biomedical analysis
Cirovic, S. (2024) · doi:10.24834/isbn.9789178774562 · Cited by 7
Bernal-Contreras, K. D., Berrospe-Alfaro, M., de Cárdenas-Rojo, R. L., Ramos-Ostos, M. H., Uribe, M., López-Méndez, I., & Juárez-Hernández, E. (2024) · Frontiers in Nutrition · doi:10.3389/fnut.2024.1490277 · Cited by 7
Longo, S., Cè, E., Michielon, G., Rampichini, S., Coratella, G., & Esposito, F. (2024) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2024.102972 · Cited by 6
Predicting anorexia nervosa treatment efficacy: an explainable machine learning approach
Brizzi, G., Pupillo, C., Sajno, E., Boltri, M., Brusa, F., Scarpina, F., Mendolicchio, L., & Riva, G. (2025) · Journal of Eating Disorders · doi:10.1186/s40337-025-01265-3 · Cited by 7
Bioimpedance Measurement for Monitoring Chronic Wounds: A Systematic Review
Antoszewska, M., Połomska, K., Spychalski, P., Kekonen, A., Viik, J., & Barańska‐Rybak, W. (2025) · International Wound Journal · doi:10.1111/iwj.70707 · Cited by 6
Alibrandi, M. T. S., Pisoni, M. B., Rivera, R. F., Catania, M., Vespa, M., Rosa, L. I. D., Bucci, R., Kola, K., Farinone, S., Citterio, L., et al. (2025) · Journal of Nephrology · doi:10.1007/s40620-025-02327-0 · Cited by 6
Carrier, B., Melvin, A. C., Outwin, J. R., Wasserman, M. G., Audet, A. P., Soldes, K. C., Kozloff, K. M., & Lepley, A. S. (2025) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2025.1644082 · Cited by 6
Pi, Y.-Y., Hu, W., Jiao, Z.-M., Hou, P.-Y., Zhang, Y., Zhao, Y., Li, X., Yu, J., Chen, F., Jing, J., et al. (2023) · Scientific Reports · doi:10.1038/s41598-023-44486-9 · Cited by 7
Determinants of Visfatin/NAMPT Serum Concentration and its Leukocyte Expression in Hyperthyroidism
Sawicka‐Gutaj, N., Zybek‐Kocik, A., Kloska, M., Czarnywojtek, A., Sowiński, J., Budny, B., Woliński, K., Ziemnicka, K., Mańkowska‐Wierzbicka, D., & Ruchała, M. (2018) · Hormone and Metabolic Research · doi:10.1055/a-0669-1584 · Cited by 6
Yoon, S. L., Grundmann, O., Williams, J. J., Wu, S. S., Leeuwenburgh, C., Huo, Z., & George, T. J. (2019) · Acupuncture in Medicine · doi:10.1177/0964528419873670 · Cited by 6
Courville, A. B., Yang, S. B., Andrus, S., Hayat, N., Kuemmerle, A. M., Leahy, E., BRIKER, S. M., Zambell, K. L., Chung, S. T., & Sumner, A. E. (2020) · Nutrition · doi:10.1016/j.nut.2020.110733 · Cited by 7
Metadata
- Authors
- Khalil, S., Mohktar, M., & Ibrahim, F.
- Affiliations
- University of Malaya (MY)
- Corresponding author
- Ibrahim, Fatimah
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-06-19
- Volume
- 14
- Issue
- 6
- Pages
- 10895-10928
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC4118362
- OpenAlex
- W2082211146
- Cited by
- 712
- References
- 149
- Citations by year
- 2026: 64 · 2025: 83 · 2024: 91 · 2023: 86 · 2022: 94 · 2021: 72 · 2020: 74 · 2019: 51 · 2018: 48 · 2017: 25 · 2016: 16 · 2015: 7 · 2014: 1
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- bioelectrical impedance analysis, body composition, bioimpedance vector analysis, prediction equations, anthropometry, lean mass loss, fluid shifts, heart disease, lung disease, kidney disease, neurological disorders, infectious diseases
- MeSH terms
- Body Composition, Diagnosis, Computer-Assisted, Equipment Design, Humans, Models, Biological, Monitoring, Physiologic, Plethysmography, Impedance, Biosensing Techniques, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review