The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases.
Open accessAbstract
Bioimpedance analysis is a noninvasive, low cost and a commonly used approach for body composition measurements and assessment of clinical condition. There are a variety of methods applied for interpretation of measured bioimpedance data and a wide range of utilizations of bioimpedance in body composition estimation and evaluation of clinical status. This paper reviews the main concepts of bioimpedance measurement techniques including the frequency based, the allocation based, bioimpedance vector analysis and the real time bioimpedance analysis systems. Commonly used prediction equations for body composition assessment and influence of anthropometric measurements, gender, ethnic groups, postures, measurements protocols and electrode artifacts in estimated values are also discussed. In addition, this paper also contributes to the deliberations of bioimpedance analysis assessment of abnormal loss in lean body mass and unbalanced shift in body fluids and to the summary of diagnostic usage in different kinds of conditions such as cardiac, pulmonary, renal, and neural and infection diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“R of the conductor is expressed by R = ρL2/V, so V = ρL2/R, wherein ρ is the conductor resistivity, L is the length, and V is volume (48, 49).”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [49]
The cited source says what the claim attributes to it.
In the citing paper
“The electrical properties of the human body may explain the use of BIA to estimate FFM by the resistance index.”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [49]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200 · cited 25×
“At high frequencies, the current will pass through the whole TBW which is composed of ECF and ICF [96], so the conducting volume is equal to the ratio between TBW and total body volume.”
BackgroundMethodInfluentialESPEN Guidelines for Nutrition Screening 2002
Kondrup, J. (2003) · Clinical Nutrition · doi:10.1016/s0261-5614(03)00098-0 · Cited by 3,159
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Body mass index as a measure of body fatness: age- and sex-specific prediction formulas
Deurenberg, P., Weststrate, J., & Seidell, J. C. (1991) · British Journal of Nutrition · doi:10.1079/bjn19910073 · Cited by 1,397
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370 · cited 4×
“It was introduced by Hoofer [4] and later revised by Nyboer [3] to decrease the contact impedance between skin and electrodes, and validated by Lukaski [17] in 140 normal adults.”
MethodInfluentialBody composition of reference children from birth to age 10 years
Fomon, S. J., Haschke, F., Ziegler, E., & Nelson, S. (1982) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/35.5.1169 · Cited by 1,264
Bioimpedance and Bioelectricity Basics
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-06951-7 · Cited by 1,175
Norman, K., Stobäus, N., Pirlich, M., & Bosy-Westphal, A. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.05.008 · Cited by 1,049
Flagged first, then by citations
Research works printed but not linked: 3
- Thomasset, 1963, Bio-electrical properties of tissues, Lyon Med., 209, 1325
- Sargent, J.A., and Gotch, F.A. (1989). Replacement of Renal Function by Dialysis, Springer.
- Serrano, M.D.M., de Espinosa, M.G.-M., and Zamorano, E.M. (2012). Handbook of Anthropometry, Springer.
Cited by
Sorted by citations
Items 501–600 of 709
IoT system for non-invasive measurement of physiological parameters in animals
Álvarez, S. M., Casas, Ó., & Serrano‐Finetti, E. (2023) · IEEE International Workshop on Metrology for Industry 4.0 & IoT (MetroInd4.0&IoT) · doi:10.1109/metroind4.0iot57462.2023.10180181 · Cited by 1
Song, Y. R., Bae, M. I., Han, D. W., Park, E. J., Park, S., & Ham, S. Y. (2023) · World Journal of Surgical Oncology · doi:10.1186/s12957-023-03233-0 · Cited by 1
Relaxation differences using EIS through bronchoscopy of healthy and pathological lung tissue
Georgina Company-Se, Nescolarde, L., Pajares, V., Torregó, A., Rafecas, A., Rosell, J., Riu, P. J., & Bragós, R. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10341117 · Cited by 1
Effect of kefir and soy yogurt consumption on serum IGF-1 levels in young healthy women
Aperio, C., Santangelo, C., Pietrangelo, T., Haghshenas, L., Offidani, L. F., & Marotta, F. (2024) · Functional Food Science · doi:10.31989/ffs.v4i1.1268 · Cited by 1
Concealed Simultaneous Measurements of Biopotential and Bioimpedance on Rodents
Álvarez, S. M., Casas, Ó., & Serrano‐Finetti, E. (2024) · IEEE International Instrumentation and Measurement Technology Conference · doi:10.1109/i2mtc60896.2024.10560947 · Cited by 1
Building a quality management system
Lanerolle, G. D., Roberts, E. S., Haroon, A., & Shetty, A. (2024) · Elsevier eBooks · doi:10.1016/b978-0-12-822732-9.00009-6 · Cited by 1
Gutiérrez‐Carretero, E., Campos, A. M., Giménez, L., Rezaei, K., Peña, A., Rossel, J., Praena, J. M., Smani, T., Ordóñez, A., & Medrano, F. J. (2024) · Medicina Clínica (English Edition) · doi:10.1016/j.medcle.2024.02.014 · Cited by 1
Kuljić, B., Vizvári, Z., Győrfi, N., Klincsik, M., Sari, Z., Kovács, F., Juhos, K., Szakáll, T., Odry, Á., Kovács, L., et al. (2024) · Electronics · doi:10.3390/electronics13163300 · Cited by 1
A Method for Predicting Allelic Variants of Single Nucleotide Polymorphisms
Tyagunova, E. E., Захаров, А. С., Pavlova, G. V., Ogarkova, D. A., Жученко, Н. А., & Gushchin, V. А. (2024) · Current Topics in Medicinal Chemistry · doi:10.2174/0115680266328330240828040922 · Cited by 1
Maurencig, S., Palmero, M., Algarín, A., Scagliusi, S. F., Pérez, P., Martín, D., Huertas, G., & Yúfera, A. (2024) · IEEE BioSensors Conference (BioSensors) · doi:10.1109/biosensors61405.2024.10712672 · Cited by 1
Wrist-to-Wrist Bioimpedance Can Reliably Detect Discrete Self-Touch
Forte, M., Vardar, Y., Javot, B., & Kuchenbecker, K. J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3544385 · Cited by 2
Monitoring Sodium Intake With a Salt Meter in Hemodialysis Patients
Akkabut, W., Trakulsuntornchai, W., Junhoaton, S., Kitpermkiat, R., Shantavasinkul, P. C., & Kantachuvesiri, S. (2025) · Kidney International Reports · doi:10.1016/j.ekir.2025.06.027 · Cited by 1
Jiang, H., Wong, J. J., Tan, G. H. M., Teo, L. L., Ewe, S. H., Tan, R., Gao, F., & Koh, A. S.-M. (2025) · JACC Advances · doi:10.1016/j.jacadv.2025.102097 · Cited by 1
Obesity Influence on Insulin Activity and Resting Metabolic Rate in Type 2 Diabetes
Doros, R., Lixandru, D., Petcu, L. M., Picu, A. A., Mitu, M., Tudosoiu, J., & Ionescu-Tirgoviste, C. (2016) · Romanian Journal of Diabetes Nutrition and Metabolic Diseases · doi:10.1515/rjdnmd-2016-0044 · Cited by 1
RenHe, L., & Wongkittisuksa, B. (2017) · International Electrical Engineering Congress (iEECON) · doi:10.1109/ieecon.2017.8075899 · Cited by 1
Electrical impedance mapping for localizing evolving traumatic brain injury
Everitt, A. C., Root, B. K., Bauer, D. F., & Halter, R. J. (2019) · SPIE Medical Imaging: Biomedical Applications in Molecular, Structural, and Functional Imaging · doi:10.1117/12.2512292 · Cited by 1
SEGREGATION OF NORMAL AND CANCER CELLS BASED ON IMPEDANCE CHARACTERISTICS OF SINGLE CELL
Gupta, S., & JOGI, V. (2019) · INTERNATIONAL JOURNAL OF ADVANCED RESEARCH IN ENGINEERING & TECHNOLOGY · doi:10.34218/ijaret.10.3.2019.016 · Cited by 1
Obesity and Arterial Hypertension: Modern View on Pathogenesis, Diagnosis and Treatment
Горопко, О. Ю. (2019) · Family Medicine · doi:10.30841/2307-5112.2.2019.174626 · Cited by 1
BIOIMPEDANCE ANALYSIS OF BODY WATER VOLUMES IN PREGNANT WOMEN WITH HYPERTENSIVE DISORDERS
Ostafiichuk, S. O. (2019) · Bulletin of Problems Biology and Medicine · doi:10.29254/2077-4214-2019-4-1-153-134-138 · Cited by 1
Cesarelli, G., Donisi, L., Caprio, G. D., Scioli, M., Biancardi, A., & D’Addio, G. (2021) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea52024.2021.9478776 · Cited by 1
Bracelet Textile Electrodes for Bioimpedance Measurements
Monti, G., Paiano, E., Raheli, F., & Tarricone, L. (2022) · IEEE MTT-S International Microwave Biomedical Conference (IMBioC) · doi:10.1109/imbioc52515.2022.9790244 · Cited by 1
Nambirajan, M. K., Govindan, D., Patel, N., Roy, G., & Lakshminarayanan, S. (2022) · International Journal of Community Medicine and Public Health · doi:10.18203/2394-6040.ijcmph20221761 · Cited by 1
MRI-Based Body Composition Analysis
Borga, M., Ahlgren, A., & Weston, S. (2022) · Methods and protocols in food science · doi:10.1007/978-1-0716-2345-9_19 · Cited by 1
Nutrition: The Very Old Critically Ill Patients
Berger, M. M., Hurni, C., & Pantet, O. (2022) · Lessons from the ICU · doi:10.1007/978-3-030-94133-8_22 · Cited by 1
Multifaceted Nutritional Disorders in Elderly Patients Undergoing Dialysis
Mori, K., Kurajoh, M., Inaba, M., & Emoto, M. (2022) · Kidney and Dialysis · doi:10.3390/kidneydial3010001 · Cited by 1
An IoT-Based Smart Health Monitoring System
Lakshmi, R., Mridula, M., Gayathri, G., & Srividhyasakthi, V. (2023) · Lecture notes in networks and systems · doi:10.1007/978-981-99-1624-5_27 · Cited by 1
Negesse, A., Gebremariam, B. M., kebede, T., Kifle, A., Alemayehu, D., Negesse, Y., Tesfaye, S., & Fite, A. (2021) · Preprints.org · doi:10.20944/preprints202105.0637.v1 · Cited by 1
Association Between Body Composition with Pulmonary Function TestsPreprint
Pouragha, H., Kazemi, H., Pouryaghoub, G., & Mehrdad, R. (2020) · Research Square · doi:10.21203/rs.3.rs-112097/v1 · Cited by 1
Noninvasive Multimodal Physiological Sensing Systems
Kimball, J. P., Gazi, A. H., Ozmen, G. C., Jung, H., Shandhi, M. M. H., Mabrouk, S. A., Gharehbaghi, S., Ganti, V. G., & Inan, O. T. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00094-7 · Cited by 1
Turkistani, W. M., Azzeh, F. S., Ghaith, M. M., Bahubaish, L. A., Kensara, O. A., Almasmoum, H. A., Aldairi, A. F., Khan, A. A., Al-Ghamdi, A., Shamlan, G. H., et al. (2022) · Preprints.org · doi:10.20944/preprints202204.0217.v1 · Cited by 1
Káňová, M., Petřeková, K., Borzenko, N., Rusková, K., Nytra, I., Dzurňáková, P., & Burda, M. (2023) · Research Square · doi:10.21203/rs.3.rs-3485725/v1 · Cited by 1
Yoshimura, Y., Wakabayashi, H., Nagano, F., Matsumoto, A., Shimazu, S., Shiraishi, A., Kido, Y., Bise, T., Hori, K., & Yoneda, K. (2023) · Clinical Nutrition · doi:10.1016/j.clnu.2023.11.021 · Cited by 1
Cretescu, I., Munteanu, O., Mocanu, V., & Horhat, R. (2026) · Applied Sciences · doi:10.3390/app16021082
Design and Development of Microfluidic Lab-On-Chip Bioimpedance Analyzer
Mohanty, S. (2015)
McFall, S. E. (2017) · University of Birmingham Institutional Research Archive (University of Birmingham)
Sanchez, M. (2017) · Institutional Repository of the University of Granada (University of Granada) · doi:10.30827/digibug.45267
Toxicology Analysis of Tissue-Mimicking Phantom Made From Gelatin
Dolbashid, A. S., Hamzah, N., Zaman, W. S. W. K., & Mokhtar, M. S. (2017) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/210/1/012004
Considering Blood Dilution improves the Precision of Continuous Whole Blood Glucose Measurements
Benesch, C., Kuhlenkötter, M., & Heise, T. (2018) · Journal of Diabetes Science and Technology · doi:10.1177/1932296818803621
Editorial: moving towards a robust definition of sarcopenia in cirrhosis—authors' reply
Engelmann, C., Schob, S., Seehofer, D., & Berg, T. (2019) · Alimentary Pharmacology & Therapeutics · doi:10.1111/apt.15086
Evaluation of Vascular Status and Detection of Diseases Using Non-Invasive Bio-Impedance Analysis
Shash, Y. H., Eldosoky, M. A. A., & El-Wakad, M. T. (2019) · National Radio Science Conference · doi:10.1109/nrsc.2019.8734529
The relationship between overhydration, increased oxidative stress and peritoneal dialysis adequacy
Stepanova, N., Korol, L., Burdeyna, O., & Snisar, L. (2019) · Ukrainian Journal of Nephrology and Dialysis · doi:10.31450/ukrjnd.2(62).2019.02
Bioimpedance Spectroscopy in Subjects with Auricular Vagus Nerve Stimulation
Ülgen, Y., Büyüksaraç, B., Tunç, B., & Solmaz, H. (2019) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2019.8802168
Linear Regression Models for Fat Free Mass Measurement Based on Bioelectrical Impedance Analysis
Fahim, T. A., Anower, M. S., Khatun, M. F., & Zuhori, S. T. (2019) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2019.8861576
Mathematical Models for Fat Free Mass Measurement Based on Bioelectrical Impedance Analysis
Fahim, T. A., & Anower, M. S. (2019) · International Conference on Advances in Science, Engineering and Robotics Technology (ICASERT) · doi:10.1109/icasert.2019.8934477
ДИНАМІКА ВОДНИХ СЕКТОРІВ У ВАГІТНИХ ЖІНОК ІЗ ПАТОЛОГІЧНИМ ГЕСТАЦІЙНИМ ЗБІЛЬШЕННЯМ МАСИ ТІЛА
Ostafiichuk, S. O. (2020) · Актуальні питання педіатрії акушерства та гінекології · doi:10.11603/24116-4944.2019.2.10920
Výživa a dietetika v ošetřovatelské péči 1
Tomanová, J. (2019) · doi:10.5507/fzv.19.24456324
Digital Equalizer Design of Biosensor for Portable Bioimpedance Analyzer
Khoma, Y., & Khoma, V. (2020) · Advanced Information Systems · doi:10.20998/2522-9052.2020.2.15
Evaluation and Management of Nutrition in Chronic Liver Disease
Rogers, M. (2020) · Academic Journal of Gastroenterology & Hepatology · doi:10.33552/ajgh.2020.01.000520
Nutritional challenges in adult patients with cystic fibrosis pre and post lung transplantation
Hollander-Kraaijeveld, F. M. (2020) · doi:10.33540/46
Lin, E., Lin, B., Tsai, L., Chen, W., Wang, Y., Chiang, H., & Chang, C. (2020) · Wound Repair and Regeneration · doi:10.1111/wrr.12866
Cerrato, A., Cocco, M., Zanette, G., Frigo, A. C., & Bacci, C. (2021) · Research Square · doi:10.21203/rs.3.rs-254678/v1
Investigation of Changes in Quality Indicators of Agro-Industry Products During
Novikova, M., Blinov, A., & Konchina, L. V. (2021) · IOP Conference Series Earth and Environmental Science · doi:10.1088/1755-1315/666/2/022092
Experimental Study of Electrode Design and Configuration for Bioimpedance Measurement
Nur’aidha, A. C., & Kumarajati, D. Y. H. (2021) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1823/1/012009
High resolution manometry in esophageal disorders
Ladić, A., Jaklin-Kekez2, A., Rustemović, N., & Krznarić, Ž. (2021) · Liječnički vjesnik · doi:10.26800/lv-143-3-4-7
Hausen, A., Henschel, D., Heuser, R. R., Harnischmacher, M., Kloeß, C., Pröbstl, A., Schmidt‐Wolf, I. G. H., Strassburg, C. P., Kalff, J. C., & von Websky, M. (2021) · Zentralblatt für Chirurgie - Zeitschrift für Allgemeine Viszeral- Thorax- und Gefäßchirurgie · doi:10.1055/a-1481-9227
Fajardo, C. M. (2020) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.9.2020.tde-25062021-154412
Kocherha, Z. R., Nedostup, I. S., Pavlykivska, B. M., Tereshkun, N. M., & Kazimyrchuk, I. V. (2021) · CHILD`S HEALTH · doi:10.22141/2224-0551.16.5.2021.239713
A woven electrode with convex structure for electrical impedance tomography
Zhang, X., Zhong, Y., Wang, Q., & Dou, C. (2021) · Textile Research Journal · doi:10.1177/00405175211047110
BIOIMPEDANCE ANALYSIS IN THE DIAGNOSIS OF SKIN CONDITION
Martynenko, V., & Tereshchenko, M. F. (2021) · Bulletin of Kyiv Polytechnic Institute Series Instrument Making · doi:10.20535/1970.62(2).2021.249150
Nutritional imbalances in a Mexican vegan group: urgent need for country-specific dietary guidelines
Laviada‐Molina, H., Espinosa-Marrón, A., Núñez-Issac, O. A., Moreno-Enríquez, A., Sosa-Crespo, I. F., Araujo‐León, J. A., & Molina-Seguí, F. (2022) · Nutrición Hospitalaria · doi:10.20960/nh.03819
Alkahtani, S. A. (2021) · The International Scientific Journal of Physical Education and Sport Sciences · doi:10.21608/isjpes.2021.78750.1051
Miedany, Y. M. E. (2022) · Springer eBooks · doi:10.1007/978-3-030-87950-1_2
John, J. C., Gipson, G. T., King, C. D., Bunchman, T. E., & Karam, O. (2021) · Nephrology - Open Journal · doi:10.17140/npoj-6-124
Design of Low Cost Bio-impedance Measuring Instrument
Birok, R., & Kapoor, R. (2022) · International Journal of Advanced Computer Science and Applications · doi:10.14569/ijacsa.2022.0130186
Lai, Y. T., Yee, P. H., Kadir, H. B. A., Fan, L. C., Iyer, N. G., Hway, W. T., & An, G. T. C. (2022) · medRxiv · doi:10.1101/2022.01.28.22269997
Modern Methods for Assessing the Trophological Status in Patients with Rheumatic Diseases
Dostanko, N., Зыбалова, Т. С., & Ягур, В. Е. (2021) · Рецепт · doi:10.34883/pi.2021.24.4.010
Frequency Domain Adaptive Learning Algorithm for Thoracic Electrical Bioimpedance Enhancement
Rahman, M. Z. U., Rooban, S., Rohini, P., Ramprasad, M. V. S., & Kodavanti, P. V. (2022) · Computers, materials & continua/Computers, materials & continua (Print) · doi:10.32604/cmc.2022.027672
Minimally Invasive and Non‐Invasive Sensor Technologies for Predicting Heart Failure
Salman, H. E., Al-Ruweidi, M. K. A. A., Ouakad, H. M., & Yalcin, H. C. (2022) · Wiley eBooks · doi:10.1002/9781119813040.ch5
Negesse, A., Gebremariam, B. M., kebede, T., Kifle, A., Alemayehu, D., Negesse, Y., Tesfaye, S., & Fite, A. (2020) · Preprints.org · doi:10.20944/preprints202012.0399.v1
Accardi, A. J., Heywood, T., & Daleiden-Burns, A. (2018) · doi:10.2196/preprints.12939
Krátký, M., Dvorský, J., & Moravec, P. (2020) · Vysoká škola báňská - Technická univerzita eBooks · doi:10.31490/9788024844220
Ward, S., & Noland, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-30730-1_21
Биоимпедансный анализ состояния поверхностных тканей пациента
Rybyanets, A. N., Shvetsov, I. A., Швецова, Н. А., Reznichenko, A. N., & Kolpacheva, N. A. (2022) · Письма в журнал технической физики · doi:10.21883/pjtf.2022.15.53128.19158
Marchetti, B. S., Freitas, J. D. P., & Miola, T. M. (2022) · Research Square · doi:10.21203/rs.3.rs-1782608/v1
APPLICATION OF BIOIMPEDANCE ANALYSIS IN CLINICAL PRACTICE: LITERATURE REVIEW
Самойлов, А. С., Rylova, N. V., Velichko, M. N., Bodrov, A. V., & Валерьевич, Ш. А. (2022) · A I Burnasyan Federal Medical Biophysical Center Clinical Bulletin · doi:10.33266/2782-6430-2022-3-18-21
Latyshevskaya, N. I., Александровна, Д. Л., Васильевна, Б. А., Zub, A. V., & Levchenko, N. V. (2022) · Medical alphabet · doi:10.33667/2078-5631-2022-28-39-45
Cardiopulmonary Exercise Testing Among Adolescents with ObesityPreprint
Nelson, J. E., Sanchez, K. M., Yao, Y., Jin, Z., Zitsman, J. L., Kattan, M., Garofano, R. P., Layton, A. M., & De, A. (2022) · doi:10.22541/au.167240445.51884327/v1
Combinational Bioimpedance and Ultrasonic Diagnostics Method for Prospective Medical Applications
Shvetsov, I. A., Kolpacheva, N. A., Shvetsova, N. A., & Rybyanets, A. N. (2023) · Springer Proceedings in Materials · doi:10.1007/978-3-031-21572-8_40
Lewis, L., Connor, C. O., Koelmeyer, L. A., Forstner, D. F., Thompson, B. M., & Suami, H. (2022) · International Journal of Radiology & Radiation Therapy · doi:10.15406/ijrrt.2022.09.00320
Stone, M., Lukaczer, D., D’Adamo, C. R., Dotson, N., Volkov, A., Minich, D. M., Metti, D., Leary, M., Class, M., Carullo, M., et al. (2023) · Journal of Personalized Medicine · doi:10.3390/jpm13040594
Olmedo, L. (2023) · El Servicio de Difusión de la Creación Intelectual (National University of La Plata) · doi:10.35537/10915/151130
Electronic sensing and ablation needles for medical diagnosis and treatmentPreprint
Hu, Y., Limpabandhu, C., & Tse, Z. T. H. (2023) · Research Square · doi:10.21203/rs.3.rs-2733234/v1
Hofmann, G., Shoumariyeh, T., Domenig, C. M., Skrabal, F., & Kovarik, J. J. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12113726
Difference in Bioimpedance Across the Knee in Un-Injured Young Adults.
Seeley, A. L., Dhillon, S., Atkinson, P. J., Srivastava, A., & Atkinson, T. (2023) · PubMed Central
Body physique rating as a factor to identify at-risk Mexicans for Metabolic Syndrome
Herrera-Fomperosa, O., Bustamante-Villagomez, S. K., Vásquez-Alvarez, S., Vazquez-Marroquin, G., Porchia, L. M., Torres‐Rasgado, E., Pérez-Fuentes, R., & González-Mejía, M. E. (2023) · Human Nutrition & Metabolism · doi:10.1016/j.hnm.2023.200206
Bioelectrical impedance devices in clinical practice: a narrative review
Rodrigues, F. B., & Bertemes-Filho, P. (2023) · Academia Medicine · doi:10.20935/acadmed6112 · Cited by 1
Antonio, P.-J. J., María, N.-D. L. O. D., Antonio, S.-C. J., Antonio, L. V. J., Rodolfo, A.-M. J., Alberto, R.-A. H., Alfonso, L.-V. E., Morales-Portano, J. D., Gómez-Álvarez, E., Juárez, B. S., et al. (2023) · Journal of Visualized Experiments · doi:10.3791/64683
Making Hospital Environment Friendly for People
Patnool, R. B., Mohammad, B. D., Kumar, A. S., & Muhasina, K. M. (2023) · Wiley eBooks · doi:10.1002/9781394200344.ch9
Feng, Q., Bešević, J., Conroy, M. C., Omiyale, W., Lacey, B., & Allen, N. E. (2023) · medRxiv · doi:10.1101/2023.11.01.23297916
Exercício físico moderado e restrição calórica
Gonçalves, R. M. T. (2021) · doi:10.47749/t/unicamp.2021.1167780
Nelson, J. E., Sanchez, K. M., Yao, Y., Jin, Z., Zitsman, J. L., Kattan, M., Garofano, R. P., Layton, A. M., & De, A. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4633028
Metadata
- Authors
- Khalil, S., Mohktar, M., & Ibrahim, F.
- Affiliations
- University of Malaya (MY)
- Corresponding author
- Ibrahim, Fatimah
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-06-19
- Volume
- 14
- Issue
- 6
- Pages
- 10895-10928
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC4118362
- OpenAlex
- W2082211146
- Cited by
- 712
- References
- 149
- Citations by year
- 2026: 64 · 2025: 83 · 2024: 91 · 2023: 86 · 2022: 94 · 2021: 72 · 2020: 74 · 2019: 51 · 2018: 48 · 2017: 25 · 2016: 16 · 2015: 7 · 2014: 1
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- bioelectrical impedance analysis, body composition, bioimpedance vector analysis, prediction equations, anthropometry, lean mass loss, fluid shifts, heart disease, lung disease, kidney disease, neurological disorders, infectious diseases
- MeSH terms
- Body Composition, Diagnosis, Computer-Assisted, Equipment Design, Humans, Models, Biological, Monitoring, Physiologic, Plethysmography, Impedance, Biosensing Techniques, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›