The DOI matches its Crossref record; 149 of the 149 references it cites were found in a registry or an index.
The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases.
Open accessAbstract
Bioimpedance analysis is a noninvasive, low cost and a commonly used approach for body composition measurements and assessment of clinical condition. There are a variety of methods applied for interpretation of measured bioimpedance data and a wide range of utilizations of bioimpedance in body composition estimation and evaluation of clinical status. This paper reviews the main concepts of bioimpedance measurement techniques including the frequency based, the allocation based, bioimpedance vector analysis and the real time bioimpedance analysis systems. Commonly used prediction equations for body composition assessment and influence of anthropometric measurements, gender, ethnic groups, postures, measurements protocols and electrode artifacts in estimated values are also discussed. In addition, this paper also contributes to the deliberations of bioimpedance analysis assessment of abnormal loss in lean body mass and unbalanced shift in body fluids and to the summary of diagnostic usage in different kinds of conditions such as cardiac, pulmonary, renal, and neural and infection diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“R of the conductor is expressed by R = ρL2/V, so V = ρL2/R, wherein ρ is the conductor resistivity, L is the length, and V is volume (48, 49).”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [49]
The cited source says what the claim attributes to it.
In the citing paper
“The electrical properties of the human body may explain the use of BIA to estimate FFM by the resistance index.”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [49]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200 · cited 25×
“At high frequencies, the current will pass through the whole TBW which is composed of ECF and ICF [96], so the conducting volume is equal to the ratio between TBW and total body volume.”
BackgroundMethodInfluentialESPEN Guidelines for Nutrition Screening 2002
Kondrup, J. (2003) · Clinical Nutrition · doi:10.1016/s0261-5614(03)00098-0 · Cited by 3,159
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Body mass index as a measure of body fatness: age- and sex-specific prediction formulas
Deurenberg, P., Weststrate, J., & Seidell, J. C. (1991) · British Journal of Nutrition · doi:10.1079/bjn19910073 · Cited by 1,397
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370 · cited 4×
“It was introduced by Hoofer [4] and later revised by Nyboer [3] to decrease the contact impedance between skin and electrodes, and validated by Lukaski [17] in 140 normal adults.”
MethodInfluentialBody composition of reference children from birth to age 10 years
Fomon, S. J., Haschke, F., Ziegler, E., & Nelson, S. (1982) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/35.5.1169 · Cited by 1,264
Bioimpedance and Bioelectricity Basics
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-06951-7 · Cited by 1,175
Norman, K., Stobäus, N., Pirlich, M., & Bosy-Westphal, A. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.05.008 · Cited by 1,049
Flagged first, then by citations
Research works printed but not linked: 3
- Thomasset, 1963, Bio-electrical properties of tissues, Lyon Med., 209, 1325
- Sargent, J.A., and Gotch, F.A. (1989). Replacement of Renal Function by Dialysis, Springer.
- Serrano, M.D.M., de Espinosa, M.G.-M., and Zamorano, E.M. (2012). Handbook of Anthropometry, Springer.
Cited by
Sorted by citations
Items 301–400 of 709
Alsowaid, L., Perna, S., Peroni, G., Gasparri, C., Alalwan, T. A., & Rondanelli, M. (2021) · Arab Journal of Basic and Applied Sciences · doi:10.1080/25765299.2021.1975403 · Cited by 6
Vongchaiudomchoke, W., Sathitkarnmanee, B., Thanakiattiwibun, C., Jarungjitaree, S., & Chaiwat, O. (2021) · Asian Journal of Surgery · doi:10.1016/j.asjsur.2021.09.012 · Cited by 6
Towards Continuous Plant Bioimpedance Fitting and Parameter Estimation
Martin, D., Reynolds, J., Daniele, M. A.-A., Lobaton, E. J., & Bozkurt, A. Y. (2021) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors47087.2021.9639492 · Cited by 6
Jauregi, A. P., Quinn, T. D., Coca, A., Mejuto, G., & Cámara, J. (2022) · Applied Ergonomics · doi:10.1016/j.apergo.2022.103784 · Cited by 8
Wang, W., Wang, C.-S., Wang, C., Yang, A., & Lin, C. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19126964 · Cited by 6
Gasser, B. A., Wagner, J., Schoch, R., & Schmidt‐Trucksäss, A. (2023) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2023.05.029 · Cited by 6
Towards Real-time Multiplexed Bioimpedance Tumour-Tissue Margin Analysis
Wong, S. S., Malik, A., Ekanayake, J., & Constandinou, T. G. (2023) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc40787.2023.10340781 · Cited by 6
Sarcopenia and Neuroendocrine Neoplasms
Clement, D., Brown, S. S., van Leerdam, M. E., Tesselaar, M. E. T., Ramage, J. K., & Srirajaskanthan, R. (2024) · Current Oncology Reports · doi:10.1007/s11912-024-01494-w · Cited by 6
Bioimpedance Analysis: Basic Concepts
Zachariah, V. K., & Priyamvada, P. S. (2023) · Journal of Renal Nutrition and Metabolism · doi:10.4103/jrnm.jrnm_9_23 · Cited by 6
Hoppe, J. E., Sjoberg, J., Hong, G., Poch, K. R., Zemanick, E. T., Thee, S. A., Edmondson, C. L., Patel, D. R., Sathe, M., Borowitz, D., et al. (2024) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2024.02.011 · Cited by 7
EFFECT OF BODY POSTURE ON SEGMENTAL MULTIFREQUENCY BIOIMPEDANCE VARIABLES
Kim, K., Jun, M., Hong, S., Kim, S., Yu, S., & Kim, J. U. (2022) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s021951942240053x · Cited by 6
Farr, B. J., Bechard, L. J., Rice‐Townsend, S. E., & Mehta, N. M. (2022) · Journal of Pediatric Surgery · doi:10.1016/j.jpedsurg.2022.07.014 · Cited by 5
Barry, V. G., Chiang, J. L., Bowman, K. G., Johnson, K. D., & Gower, B. A. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20010686 · Cited by 5
Jack, S., Andritsch, E., Joaquim, A. V., Kreissl, M. C., Locati, L. D., Netea-Maier, R. T., Reverter, J. L., & Elisei, R. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e30723 · Cited by 5
Bioimpedance Sensing and Ablation Needles for Image-Guided Therapy
Hu, Y., Limpabandhu, C., Barrett, T., & Tse, Z. T. H. (2024) · IEEE Access · doi:10.1109/access.2024.3410547 · Cited by 5
Clinician’s Guide for Pediatric Anti-obesity Medications
Dutton, W. P., Paddu, N. U., Braddock, A. S., & Sweeney, B. R. (2024) · Pediatric Clinics of North America · doi:10.1016/j.pcl.2024.07.006 · Cited by 5
A glossary for social-to-biological research
Robertson, T., Benzeval, M., Betzer, M., Booker, C. L., Castagné, R., Delpierre, C., Gallagher, I. J., Kelly‐Irving, M., McCrory, C., Morris, T., et al. (2024) · Longitudinal and Life Course Studies · doi:10.1332/17579597y2024d000000032 · Cited by 6
Bioelectrical Impedance Analysis of Body Composition in Male Childhood Brain Tumor Survivors
Romano, A., Sollazzo, F., Corbo, F., Attinà, G., Mastrangelo, S., Cordaro, S., Modica, G., Zovatto, I. C., Monti, R., Bianco, M., et al. (2024) · Diseases · doi:10.3390/diseases12120306 · Cited by 6
Exploring the significance of phase angle in diabetes management: a narrative review
Rahbardar, M. G., Ferns, G. A., & Ghayour‐Mobarhan, M. (2025) · Diabetology International · doi:10.1007/s13340-024-00790-x · Cited by 5
Panchal, J., Singh, M. I., Singh, M., & Sandha, K. S. (2025) · Sensors · doi:10.3390/s25123688 · Cited by 5
Skjærvø, Ø., Brandtzaeg, O. K., Lausund, K. B., Pabst, O., Martinsen, Ø. G., Lundanes, E., & Wilson, S. R. (2017) · Journal of Chromatography A · doi:10.1016/j.chroma.2017.12.060 · Cited by 5
Bronk, T. S., Everitt, A. C., Murphy, E. K., & Halter, R. J. (2021) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2021.3129734 · Cited by 5
Lopes, M. M. G. D., de Sousa, I. M., Queiroz, S. A., Bezerra, M. R. D. O., González, M. C., & Fayh, A. P. T. (2023) · Nutrition in Clinical Practice · doi:10.1002/ncp.11074 · Cited by 5
Body Composition Analysis using Karada Scan in Indian Collegiate Population: An Observational Study
Singh, A., Dangat, D. P., Shenoy, S., & Sandhu, J. S. (2023) · Medical Journal of Dr D Y Patil Vidyapeeth · doi:10.4103/mjdrdypu.mjdrdypu_248_21 · Cited by 5
A 3 MHz Low-Error Adaptive Howland Current Source for High-Frequency Bioimpedance Applications
Nwokoye, I. I., & Triantis, I. F. (2024) · Sensors · doi:10.3390/s24134357 · Cited by 5
Ouypornkochagorn, T., Ngamdi, N., Sillaparaya, A., Silalertdetkul, S., & Ouypornkochagorn, S. (2024) · Measurement · doi:10.1016/j.measurement.2024.115248 · Cited by 5
Santos, S. F., & Bertemes-Filho, P. (2017) · Review of Scientific Instruments · doi:10.1063/1.4991829 · Cited by 5
Electrical Impedance Signal Analysis for Medical Diagnosis
Vargas-Luna, M., Balleza, M., Franco, M. R. H., & Riu, P. J. (2018) · Springer eBooks · doi:10.1007/978-3-319-74388-2_5 · Cited by 5
Design and Development of Device to measure Body Fat using Multi-frequency Bio-impedance Method
Ain, K., Soelistiono, S., Wibowo, R. A., Muniroh, L., Anggono, T., & Sari, W. W. P. (2018) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1120/1/012043 · Cited by 5
Leg electrical resistance predicts venous blood viscosity and hematocrit
Varlet‐Marie, E., Vachoud, L., Marion, B., Roques, C., Fidani, T., Chevalier, C., Mercier, J. G., de Mauverger, É. R., & Brun, J. ‐. (2019) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-199003 · Cited by 5
BIOELECTRICAL VECTOR ANALYSIS IN OBESE ADOLESCENTS
Filho, J. M. D. O., Bernardes, P. S., Serpa, G. H. C., Siqueira, G., Noll, M. A., Venâncio, P. E. M., & Soares, V. (2020) · Revista Paulista de Pediatria · doi:10.1590/1984-0462/2020/38/2019017 · Cited by 7
Noh, H. W., Sim, J. Y., Ahn, C.-G., & Ku, Y. (2021) · Biosensors · doi:10.3390/bios11100398 · Cited by 5
Chang, C., Jan, W.-L., Juan, C.-H., Meng, N., Lin, B., & Chen, H. (2021) · Sensors · doi:10.3390/s21248187 · Cited by 5
Use of Diuretics is Associated with Higher Risk of Sarcopenia in Older Adults with Hypertension
Júnior, F. D. A. D. M., Mateo, D. P. A., Silva, F. J. D. M., de Moura, S. S., de Oliveira, E. C., Coelho, D. B., Bearzoti, E., Pinto, K. M. D. C., & Becker, L. K. (2022) · International Journal of Cardiovascular Sciences · doi:10.36660/ijcs.20200279 · Cited by 5
Golec, M., Zembala-John, J., Fronczek, M., Konka, A., Bochenek, A., Wystyrk, K., Botor, H., Zalewska−Ziob, M., Chrapiec, M., Kasperczyk, S., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0287128 · Cited by 6
An improved device for bioimpedance deviation measurements based on 4-electrode half bridge
Liu, Y., Qiao, X., Li, G., & Lin, L. (2016) · Review of Scientific Instruments · doi:10.1063/1.4963658 · Cited by 5
Kshatriya, G. K., Kumari, A., & Acharya, S. K. (2018) · Diabetes & Metabolic Syndrome Clinical Research & Reviews · doi:10.1016/j.dsx.2018.11.038 · Cited by 5
Weight status and body composition analysis among Polish boys with autism spectrum disorders
Trambacz-Oleszak, S. (2021) · Anthropological Review · doi:10.2478/anre-2021-0015 · Cited by 5
Costa, R. F., Masset, K. B., Sousa, E. C., Cabral, B. T., & Dantas, P. S. (2018) · Motricidade · doi:10.6063/motricidade.16232 · Cited by 4
Kulapatana, S., Urechie, V., Rigo, S., Mohr, A., Vance, Y. A., Okamoto, L. E., Gamboa, A. C., Shibao, C. A., Biaggioni, I., Furlan, R., et al. (2024) · Clinical Autonomic Research · doi:10.1007/s10286-024-01091-8 · Cited by 4
Borges, J., Monteiro, D., Silva, F. M., Jacinto, M., Pastilha, T., & Duarte‐Mendes, P. (2025) · PLoS ONE · doi:10.1371/journal.pone.0320858 · Cited by 4
Wireless arm-worn bioimpedance sensor for continuous assessment of whole-body hydration
Jankovic, M., Kang, S.-M., Bhattacharya, S., Kashanchi, J., Wang, J., Deoli, K., Huang, T., Johnson, A., Ambani, K., Kim, S., et al. (2025) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2504278122 · Cited by 4
Asano, Y., Yoshida, T., Tsunoda, K., Yokoyama, K., Watanabe, Y., Yoshinaka, Y., Okura, T., Kimura, M., & Yamada, Y. (2025) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2025.09.030 · Cited by 4
Rafn, B. S., Andersen, M. F., Sørensen, V., Bjerre, E., Baandrup, L., Vernal, D., Mors, O., Knop, F., Wolf, R., Tolver, A., et al. (2023) · BMC Psychiatry · doi:10.1186/s12888-023-05086-z · Cited by 4
Bioimpedance measurement: a non-invasive diagnosis of limb compartment syndrome
Novák, M., Ječmínek, V., Pleva, L., Penhaker, M., Schmidt, M., Mimra, T., Kubíček, J., & Augustýnek, M. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1433284 · Cited by 4
Alfadhli, E. M., Darandari, I., Altaweel, M., Alharbi, S., Jadw, A., Aljohani, G. A., & Mohammad, S. (2025) · Frontiers in Endocrinology · doi:10.3389/fendo.2025.1494452 · Cited by 4
Deshpande, P., Bele, V., Joshi, K. S., & Thakurdesai, P. A. (2020) · Journal of Applied Pharmaceutical Science · doi:10.7324/japs.2020.101008 · Cited by 4
Knee Muscles Composition Using Electrical Impedance Myography and Magnetic Resonance Imaging
Albano, D., Gitto, S., Vitale, J. A., Bernareggi, S., Lamorte, S., Aliprandi, A., Sconfienza, L. M., & Messina, C. (2022) · Diagnostics · doi:10.3390/diagnostics12092217 · Cited by 4
Improvement of Non-invasive Blood Sugar and Cholesterol Meter with IoT Technology
Islamudin, A. F., Rahmawati, T., Triwiyanto, T., & Abudlayev, V. (2024) · Jurnal Teknokes · doi:10.35882/teknokes.v17i1.666 · Cited by 4
Nisini, N., Corda, A., Birettoni, F., Miglio, A., & Antognoni, M. T. (2024) · Veterinary Research Communications · doi:10.1007/s11259-024-10555-1 · Cited by 4
Wojteczek, A., Chmielewski, M., & Zdrojewski, Z. (2024) · Reumatologia/Rheumatology · doi:10.5114/reum/194035 · Cited by 4
Ferri‐Morales, A., Ando-Lafuente, S., Lírio-Romero, C., Marzetti, E., & Bravo-Esteban, E. (2024) · Sensors · doi:10.3390/s24227343 · Cited by 5
A comprehensive review of computational diagnostic techniques for lymphedema
R, J. K., Vijayakumar, D. K., Sugumaran, V., & Pathinarupothi, R. K. (2025) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ada85a · Cited by 4
Devarasu, N., & Sudha, G. F. (2019) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2018-0203 · Cited by 4
Changes in Body Adiposity in Women Undergoing Breast Cancer Treatment: A Scoping Review
Poltronieri, T. S., Pérsico, R. S., Falcetta, F. S., & Viana, L. V. (2022) · Nutrition and Cancer · doi:10.1080/01635581.2022.2081341 · Cited by 4
Metrological characterization of instruments for body impedance analysis
Marcotuli, V., Zago, M., Moorhead, A. P., Vespasiani, M., Vespasiani, G., & Tarabini, M. (2022) · ACTA IMEKO · doi:10.21014/acta_imeko.v11i3.1179 · Cited by 4
Polak-Szczybyło, E., Stępień, A. E., Zielińska, M., & Dąbrowski, M. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm12010056 · Cited by 4
Predictive Cell Culture Time Evolution Based on Electric Models
Serrano, J. M., Pérez, P., Daza, P., Huertas, G., & Yúfera, A. (2023) · Biosensors · doi:10.3390/bios13060668 · Cited by 4
Ouni, C., Ammar, N., Kallel, A. Y., Nouri, H., Atitallah, B. B., Fakhfakh, A., & Kanoun, O. (2023) · International Workshop on Impedance Spectroscopy (IWIS) · doi:10.1109/iwis61214.2023.10302819 · Cited by 4
Hammoud, A., latypova, A., An, T., Safronova, T., Briko, A. N., & Евгеньевна, П. А. (2023) · Systems and Technologies of the Digital HealthCare (STDH) · doi:10.1109/stdh59314.2023.10490638 · Cited by 4
Cosoli, G., Scalise, L., Cerri, G., Russo, P., Tricarico, G., & Tomasini, E. P. (2017) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2017.1291804 · Cited by 4
A real-time 4-bit imaging electrical impedance sensing biopsy needle for prostate cancer detection
Everitt, A. C., Halter, R. J., & Manwaring, P. K. (2018) · SPIE Medical Imaging: Biomedical Applications in Molecular, Structural, and Functional Imaging · doi:10.1117/12.2293799 · Cited by 4
Kowalczuk, K., Puchalska, L., Palonek, H., Sobotnicki, A., Janewicz, M., Wyleżoł, M., & Gazdzinski, S. P. (2018) · The Polish Journal of Aviation Medicine Bioengineering and Psychology · doi:10.13174/pjambp.16.07.2018.01 · Cited by 4
Orjuela, N. G., Barrera, M. D. P., Gutiérrez-Sepúlveda, M. P., Merchán-Chaverra, R. A., León-Avendaño, A. C., Caicedo-Torres, L. M., Hernández-Rodríguez, M. X., & Montaña-Palma, A. A. (2019) · Revista de la Facultad de Medicina · doi:10.15446/revfacmed.v67n3.68897 · Cited by 5
Bahouth, M. N., Negoita, S., Tenberg, A., Zink, E. K., Saylor, M. A., Davidson, P. M., Suárez, J. I., Szanton, S. L., & Gottesman, R. F. (2022) · Journal of the Neurological Sciences · doi:10.1016/j.jns.2022.120413 · Cited by 4
Bioelectrical Impedance Analysis in Critical Care
Formenti, P., Bolgiaghi, L., & Chiumello, D. (2018) · Annual update in intensive care and emergency medicine · doi:10.1007/978-3-319-73670-9_22 · Cited by 4
Feasibility of Assessing Sodium-Associated Body Fluid Composition in End-Stage Renal Disease
Clark‐Cutaia, M. N., Reisinger, N. C., Anache, M. R., Ramos, K., Sommers, M. S., Townsend, R. R., Yu, G., & Fargo, J. D. (2019) · Nursing Research · doi:10.1097/nnr.0000000000000320 · Cited by 4
Serum Fatty Acids Chemical Characterization after Prolonged Exposure to a Vegan Diet
Espinosa-Marrón, A., Laviada‐Molina, H., Moreno-Enríquez, A., Sosa-Crespo, I. F., Molina-Seguí, F., Villaseñor-Espinosa, M. F., Ciau-Mendoza, J. A., & Araujo‐León, J. A. (2019) · Journal of Food and Nutrition Research · doi:10.12691/jfnr-7-10-8 · Cited by 5
Raschka, C. J., Koch, H. J., & Käsebieter, J. (2020) · Papers on Anthropology · doi:10.12697/poa.2020.29.1.03 · Cited by 4
Understanding Body Composition Analysis in Obesity Management
Agarwal, K., Manoharan, F., & Kapoor, N. (2025) · Journal of the Association of Physicians of India · doi:10.59556/japi.73.0846 · Cited by 3
Lafontant, K., Fukuda, D. H., Chovatia, D., Latta, C., Banarjee, C., Stout, J. R., Xie, R., Lopez, J., & Thiamwong, L. (2025) · Sensors · doi:10.3390/s25134181 · Cited by 3
Wearable battery-free chip-less patch for bioimpedance measurement of cutaneous lesions
Imtiaz, H., Ray, E., Lim, E., Tahernezhadi, M., & Moghimi, M. J. (2025) · npj Biomedical Innovations. · doi:10.1038/s44385-025-00037-7 · Cited by 3
Camacho‐Barcia, L., Sánchez-Salido, L. T., del Toro, J. J., Granero, R., Sánchez, I., Supit, K., Micali, N., Giel, K. E., Jiménez‐Múrcia, S., Zipfel, S., et al. (2025) · European Eating Disorders Review · doi:10.1002/erv.70034 · Cited by 4
Höld, E., Rathmanner, T., & Heller, M. (2025) · JMIR Formative Research · doi:10.2196/70964 · Cited by 3
New Insights on Hydration Monitoring in Elderly Patients by Interdigitated Wearable Sensors
Sebar, L. E., Bonaldo, S., Cristaldi, L., Franchin, L., Grassini, S., Iannucci, L., Lombardo, L., Mineo, C., Neviani, A., Restelli, L., et al. (2025) · Sensors · doi:10.3390/s25227081 · Cited by 3
Ahmed, A., Ahmed, S., Shah, W. H., Iqbal, R., Akhter, J., Jabbar, A., Azam, I., Awan, S., & Tuomilehto, J. (2025) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2025.113019 · Cited by 3
Boukabache, A., Maruthainar, N., Manhas, V., & Player, D. J. (2026) · JMIR Perioperative Medicine · doi:10.2196/84011 · Cited by 3
Huynh, D. N., Tran, T. N., Tran, K. T., Le, N. K., Le, C. D., Mai, H. X., Huynh, Q. L., & Nguyen, T.-H. (2026) · Scientific Reports · doi:10.1038/s41598-026-38782-3 · Cited by 3
Practical Characterization of Cell-Electrode Electrical Models in Bio-Impedance Assays
Serrano, J. M., Pérez, P., Maldonado, A., Martín, M. E., Olmo, A., Daza, P., Huertas, G., & Yúfera, A. (2018) · International Joint Conference on Biomedical Engineering Systems and Technologies (BIOSTEC) · doi:10.5220/0006712601000108 · Cited by 3
A novel method for measuring body bioimpedance and its FPGA implementation
Salarabedi, H., Chabok, S. J. S. M., Sarraf, M. J., & Kobravi, H.-R. (2023) · Microprocessors and Microsystems · doi:10.1016/j.micpro.2023.104817 · Cited by 3
Elastic Textile Wristband for Bioimpedance Measurements
Monti, G., Raheli, F., Recupero, A., & Tarricone, L. (2023) · Sensors · doi:10.3390/s23063351 · Cited by 3
Bostan, M. S. (2023) · Turkish Journal of Trauma and Emergency Surgery · doi:10.14744/tjtes.2023.94034 · Cited by 3
A testösszetétel meghatározásának módszerei a klinikai gyakorlatban
Leel-Őssy, T., Babity, M., Zámodics, M., Szigeti, E., Hájer, A., Kiss, O., Horváth, C., & Mészáros, S. (2025) · Orvosi Hetilap · doi:10.1556/650.2025.33154 · Cited by 3
Mendes, G. L., Oliveira, H. A., dos Reis, A. S., Nakamoto, F. P., Staibano, A., Alvares, L. A. M., Ferreira, R. E. S., dos Santos, R. V. T., & Quaresma, M. V. L. D. S. (2025) · Nutrition and Health · doi:10.1177/02601060241307981 · Cited by 4
The Prospective Applications of Bioelectrical Impedance Analysis in Postpartum Women
Siek, J., Masiarz, A., Obuchowska, K., Kopeć, M., Małysza, Z., & Kimber-Trojnar, Ż. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14041126 · Cited by 3
Body composition monitoring through bioelectrical impedance analysis
Chetan, M. (2015) · International Symposium on Advanced Topics in Electrical Engineering · doi:10.1109/atee.2015.7133826 · Cited by 3
Devarasu, N., & Sudha, G. F. (2018) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2017-0174 · Cited by 3
Schotman, J. M., van Borren, M. M. G. J., Wetzels, J. F. M., Kloke, H. J., Reichert, L. J. M., & de Boer, H. (2020) · European Journal of Clinical Nutrition · doi:10.1038/s41430-020-0655-y · Cited by 3
Бочарин, И., & Guryanov, M. (2021) · KARELIAN SCIENTIFIC JOURNAL · doi:10.26140/knz4-2021-1002-0002 · Cited by 3
Validation of non-empirical fat-free mass estimation model for a wrist-worn device
Полохин, А. А., Pronina, E. A., Boev, A., & Gorbunov, S. (2022) · Journal of Electrical Bioimpedance · doi:10.2478/joeb-2022-0006 · Cited by 4
A Standardized Protocol for Measuring Bioelectrical Impedance in Green Turtles (Chelonia mydas)
Kophamel, S., Ward, L. C., Ariel, E., Méndez, D., O’Brien, L. M., Burchell, L., & Munns, S. L. (2022) · Physiological and Biochemical Zoology · doi:10.1086/722451 · Cited by 3
Segmental bioelectrical impedance analysis for Korean older population with cold pattern
Doan, D. N. T., Kim, K., Kim, S. G., Lee, S., Lee, K. H., & Kim, J. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.975464 · Cited by 3
WEARABLE MULTIPARAMETRIC DEVICE FOR REMOTE MONITORING OF CARDIORESPIRATORY FUNCTION
Spadotto, A., Moscato, S., Massaro, G., Spagni, S., Chiari, L., & Diemberger, I. (2023) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519423400298 · Cited by 3
Gyergyek, A., Kozjek, N. R., & Klen, J. (2023) · Radiology and Oncology · doi:10.2478/raon-2023-0028 · Cited by 3
Anakmeteeprugsa, S., Fiol, A. G., Vychodil, R., Shelley, K. H., & Alian, A. A. (2023) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-023-01098-y · Cited by 3
Whole-body phase angle correlates with pre-operative markers in total joint arthroplasty
Marinier, M. C., Ogunsola, A. S., & Elkins, J. M. (2023) · Journal of Electrical Bioimpedance · doi:10.2478/joeb-2023-0008 · Cited by 3
Davico, G., Labanca, L., Gennarelli, I., Benedetti, M. G., & Viceconti, M. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1356417 · Cited by 3
Kadhim, I. F., Banarjee, C., Fu, J., Choudhury, R., Mangum, L. C., Fukuda, D. H., Stout, J. R., Cramer, J. T., & Park, J. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3435798 · Cited by 6
Shin, Y., Kim, M. S., Yang, Y. A., Jeon, G. R., Kim, J. H., Choi, Y. J., Choi, W. C., & Kim, J. H. (2024) · Biomedicines · doi:10.3390/biomedicines12102392 · Cited by 3
Franco, I., Bianco, A., Prospero, L., Riezzo, G., Bonfiglio, C., Bagnato, C. B., Verrelli, N., Goscilo, F., D’Attoma, B., Ignazzi, A., et al. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13226684 · Cited by 4
Metadata
- Authors
- Khalil, S., Mohktar, M., & Ibrahim, F.
- Affiliations
- University of Malaya (MY)
- Corresponding author
- Ibrahim, Fatimah
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-06-19
- Volume
- 14
- Issue
- 6
- Pages
- 10895-10928
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC4118362
- OpenAlex
- W2082211146
- Cited by
- 712
- References
- 149
- Citations by year
- 2026: 64 · 2025: 83 · 2024: 91 · 2023: 86 · 2022: 94 · 2021: 72 · 2020: 74 · 2019: 51 · 2018: 48 · 2017: 25 · 2016: 16 · 2015: 7 · 2014: 1
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- bioelectrical impedance analysis, body composition, bioimpedance vector analysis, prediction equations, anthropometry, lean mass loss, fluid shifts, heart disease, lung disease, kidney disease, neurological disorders, infectious diseases
- MeSH terms
- Body Composition, Diagnosis, Computer-Assisted, Equipment Design, Humans, Models, Biological, Monitoring, Physiologic, Plethysmography, Impedance, Biosensing Techniques, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review