The DOI matches its Crossref record; 149 of the 149 references it cites were found in a registry or an index.
The theory and fundamentals of bioimpedance analysis in clinical status monitoring and diagnosis of diseases.
Open accessAbstract
Bioimpedance analysis is a noninvasive, low cost and a commonly used approach for body composition measurements and assessment of clinical condition. There are a variety of methods applied for interpretation of measured bioimpedance data and a wide range of utilizations of bioimpedance in body composition estimation and evaluation of clinical status. This paper reviews the main concepts of bioimpedance measurement techniques including the frequency based, the allocation based, bioimpedance vector analysis and the real time bioimpedance analysis systems. Commonly used prediction equations for body composition assessment and influence of anthropometric measurements, gender, ethnic groups, postures, measurements protocols and electrode artifacts in estimated values are also discussed. In addition, this paper also contributes to the deliberations of bioimpedance analysis assessment of abnormal loss in lean body mass and unbalanced shift in body fluids and to the summary of diagnostic usage in different kinds of conditions such as cardiac, pulmonary, renal, and neural and infection diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“R of the conductor is expressed by R = ρL2/V, so V = ρL2/R, wherein ρ is the conductor resistivity, L is the length, and V is volume (48, 49).”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [49]
The cited source says what the claim attributes to it.
In the citing paper
“The electrical properties of the human body may explain the use of BIA to estimate FFM by the resistance index.”
From Development and Cross-Validation of a Predictive Equation for Fat-Free Mass in Brazilian Adolescents by Bioelectrical Impedance (2022) · cites this paper as [49]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200 · cited 25×
“At high frequencies, the current will pass through the whole TBW which is composed of ECF and ICF [96], so the conducting volume is equal to the ratio between TBW and total body volume.”
BackgroundMethodInfluentialESPEN Guidelines for Nutrition Screening 2002
Kondrup, J. (2003) · Clinical Nutrition · doi:10.1016/s0261-5614(03)00098-0 · Cited by 3,159
Bioelectrical impedance analysis—part II: utilization in clinical practice
Kyle, U. G., Bosaeus, I., De Lorenzo, A. D., Deurenberg, P., Elia, M., Manuel Gómez, J., Lilienthal Heitmann, B., Kent-Smith, L., Melchior, J.-C., Pirlich, M., et al. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.09.012 · Cited by 2,350
Assessment of fat-free mass using bioelectrical impedance measurements of the human body
Lukaski, H., Johnson, P., Bolonchuk, W., & Lykken, G. (1985) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/41.4.810 · Cited by 1,896
Body mass index as a measure of body fatness: age- and sex-specific prediction formulas
Deurenberg, P., Weststrate, J., & Seidell, J. C. (1991) · British Journal of Nutrition · doi:10.1079/bjn19910073 · Cited by 1,397
Validation of tetrapolar bioelectrical impedance method to assess human body composition
Lukaski, H. C., Bolonchuk, W. W., Hall, C. B., & Siders, W. A. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.4.1327 · Cited by 1,370 · cited 4×
“It was introduced by Hoofer [4] and later revised by Nyboer [3] to decrease the contact impedance between skin and electrodes, and validated by Lukaski [17] in 140 normal adults.”
MethodInfluentialBody composition of reference children from birth to age 10 years
Fomon, S. J., Haschke, F., Ziegler, E., & Nelson, S. (1982) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/35.5.1169 · Cited by 1,264
Bioimpedance and Bioelectricity Basics
(2015) · Elsevier eBooks · doi:10.1016/c2012-0-06951-7 · Cited by 1,175
Norman, K., Stobäus, N., Pirlich, M., & Bosy-Westphal, A. (2012) · Clinical Nutrition · doi:10.1016/j.clnu.2012.05.008 · Cited by 1,049
Flagged first, then by citations
Research works printed but not linked: 3
- Thomasset, 1963, Bio-electrical properties of tissues, Lyon Med., 209, 1325
- Sargent, J.A., and Gotch, F.A. (1989). Replacement of Renal Function by Dialysis, Springer.
- Serrano, M.D.M., de Espinosa, M.G.-M., and Zamorano, E.M. (2012). Handbook of Anthropometry, Springer.
Cited by
Sorted by citations
Items 101–200 of 709
Some clarifications of terminology may facilitate sarcopenia assessment
Lewandowicz, A., Slawinski, P. R., Kądalska, E., & Targowski, T. (2020) · Archives of Medical Science · doi:10.5114/aoms.2020.91293 · Cited by 22
Cheon, S.-I., Kweon, S.-J., Kim, Y.-I., Koo, J., Ha, S., & Je, M. (2022) · Sensors · doi:10.3390/s22041563 · Cited by 22
Stanley, B., Greig, C. A., Jackson, T., Lewis, D., Moorey, H. C., Majid, Z., Masud, T., Pinkney, T. D., & Welch, C. (2023) · BMC Geriatrics · doi:10.1186/s12877-023-04177-6 · Cited by 24
A new six-electrode electrical impedance technique for probing deep organs in the human body
Roy, S. K., Karal, M. A. S., Kadir, M. A., & Rabbani, K. S. E. (2019) · European Biophysics Journal · doi:10.1007/s00249-019-01396-x · Cited by 22
Kumar, G., Kasiviswanathan, U., Mukherjee, S., Mahto, S. K., Sharma, N., & Patnaik, R. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab47ee · Cited by 22
Chang, S., & Chiu, S. (2020) · Journal of Clinical Nursing · doi:10.1111/jocn.15277 · Cited by 23
Więch, P., Bazaliński, D., Sałacińska, I., Binkowska‐Bury, M., Korczowski, B., Mazur, A., Kózka, M., & Dąbrowski, M. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120516 · Cited by 22
Fischer, A., Anwar, M., Hertwig, A., Hahn, R., Pesta, M., Timmermann, I., Siebenrock, T., Liebau, K., & Hiesmayr, M. (2020) · Clinical Nutrition Experimental · doi:10.1016/j.yclnex.2020.06.003 · Cited by 22
Does Body Position Influence Bioelectrical Impedance? An Observational Pilot Study
Więch, P., Wołoszyn, F., Trojnar, P., Skórka, M., & Bazaliński, D. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19169908 · Cited by 23
Robust Method for Mid-Activity Tracking and Evaluation of Ankle Health Post-Injury
Mabrouk, S. A., Whittingslow, D. C., & Inan, O. T. (2020) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2020.3027477 · Cited by 21
Demirbaş, N., & Kutlu, R. (2020) · Metabolic Syndrome and Related Disorders · doi:10.1089/met.2020.0098 · Cited by 21
Sasmita, B. R., Zhao, Y., Gong, M., Luo, S., & Huang, B. (2024) · Global Heart · doi:10.5334/gh.1287 · Cited by 20
A bioimpedance-based monitor for real-time detection and identification of secondary brain injury
Everitt, A., Root, B., Calnan, D., Manwaring, P., Bauer, D. F., & Halter, R. (2021) · Scientific Reports · doi:10.1038/s41598-021-94600-y · Cited by 16
Bertuccioli, A., Sisti, D., Amatori, S., Perroni, F., Rocchi, M., Benelli, P., Trecroci, A., Pierro, F. D., Bongiovanni, T., & Cannataro, R. (2022) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk7040086 · Cited by 22
Nutraceuticals and the Network of Obesity Modulators
Ammendola, S., & d’Abusco, A. S. (2022) · Nutrients · doi:10.3390/nu14235099 · Cited by 21
Malnutrition and cachexia among cancer out-patients in Nairobi, Kenya
Kaduka, L. U., Bukania, Z., Opanga, Y., Mutisya, R., Korir, A., Thuita, V., Nyongesa, C., Mwangi, M., Mbakaya, C. F. L., & Muniu, E. M. (2017) · Journal of Nutritional Science · doi:10.1017/jns.2017.61 · Cited by 20
Więch, P., Sałacińska, I., Bazaliński, D., & Dąbrowski, M. (2018) · Pediatric Rheumatology · doi:10.1186/s12969-018-0297-y · Cited by 20
Grossi, M., Palagano, R., Bendini, A., Riccò, B., Servili, M., García‐González, D. L., & Toschi, T. G. (2019) · Food Control · doi:10.1016/j.foodcont.2019.04.019 · Cited by 20
Stolwijk, J. A., & Wegener, J. (2019) · Bioanalytical reviews · doi:10.1007/11663_2019_7 · Cited by 20
Dorhout, B. G., Overdevest, E., Tieland, M., Nicolaou, M., Weijs, P. J. M., Snijder, M. B., Peters, R. J. G., van Valkengoed, I. G. M., Haveman‐Nies, A., & de Groot, C. P. G. M. (2020) · Ethnicity and Health · doi:10.1080/13557858.2020.1814207 · Cited by 20
Sarcopenia and osteoporosis in Portuguese centenarians
da Silva, A. P., Matos, A., Ribeiro, R. J. T., Gil, Á., Valente, A., Bicho, M., & Clara, J. G. (2016) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2016.174 · Cited by 20
Body Composition and Bioelectrical-Impedance-Analysis-Derived Raw Variables in Pole Dancers
Ballarin, G., Scalfi, L., Monfrecola, F., Alicante, P., Bianco, A., Marra, M., & Sacco, A. M. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph182312638 · Cited by 22
Bell, K., Ramel, S. E., Robinson, D. T., Wagner, C. L., Scottoline, B. P., & Belfort, M. B. (2022) · Journal of Perinatology · doi:10.1038/s41372-022-01529-9 · Cited by 19
Brandl, A., Egner, C., Schwarze, M., Reer, R., Schmidt, T., & Schleip, R. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12031009 · Cited by 20
Fully printed, stretchable and wearable bioimpedance sensor on textiles for tomography
Jose, M., Lemmens, M., Bormans, S., Thoelen, R., & Deferme, W. (2021) · Flexible and Printed Electronics · doi:10.1088/2058-8585/abe51b · Cited by 19
Costa, R. F. D., Silva, A. M., Masset, K. V. D. S. B., Cesário, T. D. M., Cabral, B. G. D. A. T., Ferrari, G., & Dantas, P. M. S. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.820736 · Cited by 21
“R of the conductor is expressed by R = ρL2/V, so V = ρL2/R, wherein ρ is the conductor resistivity, L is the length, and V is volume (48, 49).”
BackgroundBody impedance analyzer and anthropometric indicators; predictors of metabolic syndrome
Pouragha, H., Amiri, M., Saraei, M., Pouryaghoub, G., & Mehrdad, R. (2021) · Journal of Diabetes & Metabolic Disorders · doi:10.1007/s40200-021-00836-w · Cited by 20
Brandner, C. F., Tinsley, G. M., & Graybeal, A. J. (2022) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2022-0301 · Cited by 21
Bianco, A., Russo, F., Franco, I., Riezzo, G., Donghia, R., Curci, R., Bonfiglio, C., Prospero, L., D’Attoma, B., Ignazzi, A., et al. (2023) · Journal of Clinical Medicine · doi:10.3390/jcm12216786 · Cited by 18
Guerrini, A., Siotto, M., Germanotta, M., Cipollini, V., Cortellini, L., Pavan, A., Insalaco, S., Khazrai, Y. M., & Aprile, I. G. (2023) · Clinical Nutrition · doi:10.1016/j.clnu.2023.12.001 · Cited by 18
The effect of vascular diseases on bioimpedance measurements: mathematical modeling
Shash, Y. H., Eldosoky, M. A. A., & El-Wakad, M. T. (2018) · Biomedical Research and Therapy · doi:10.15419/bmrat.v5i6.453 · Cited by 18
Snik, D. A. C., & de Roos, N. M. (2019) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2019.05.003 · Cited by 22
Ahmed, A., Akhter, J., Iqbal, R., Jabbar, A., Mawani, M., Awan, S., Samad, Z. Z., Shaikh, P. A., Salik, M., & Tuomilehto, J. O. (2020) · Metabolic Syndrome and Related Disorders · doi:10.1089/met.2019.0098 · Cited by 17
Costa, R. F. D., Masset, K. V. D. S. B., Silva, A. M., Cabral, B. G. D. A. T., & Dantas, P. M. S. (2022) · European Journal of Clinical Nutrition · doi:10.1038/s41430-021-00946-x · Cited by 16
Mecherques-Carini, M., Albaladejo-Saura, M., Vaquero‐Cristóbal, R., Baglietto, N., & Esparza-Ros, F. (2024) · Frontiers in Nutrition · doi:10.3389/fnut.2024.1421950 · Cited by 20
Sarcopenia Identification during Comprehensive Geriatric Assessment
Pachołek, K., & Sobieszczańska, M. I. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19010032 · Cited by 17
Smart Bio-Impedance-Based Sensor for Guiding Standard Needle Insertion
Александрович, К. И., Shchukin, S. I., Mugeb, A.-H., & Shcherbachev, A. V. (2022) · Sensors · doi:10.3390/s22020665 · Cited by 16
Velázquez-Alva, M. C., Irigoyen‐Camacho, M. E., Zepeda‐Zepeda, M. A., Rangel-Castillo, I., Arrieta‐Cruz, I., Mendoza‐Garcés, L., Castaño-Seiquer, A. L., Fraile, J. F., & Juárez, R. G. (2022) · Frontiers in Nutrition · doi:10.3389/fnut.2022.978971 · Cited by 16
Obesity – Standards, trends and advances
Gołacki, J., & Matyjaszek‐Matuszek, B. (2024) · Advances in Medical Sciences · doi:10.1016/j.advms.2024.04.001 · Cited by 17
Handheld Electrical Impedance Myography Probe for Assessing Carpal Tunnel Syndrome
Li, Z., Chen, L., Zhu, Y., Wei, Q., Liu, W., Tian, D., & Yu, Y. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1819-3 · Cited by 16
Schotman, J. M., van Borren, M. M. G. J., Kooistra, M. P., Doorenbos, C. J., & de Boer, H. (2019) · Clinical Nutrition ESPEN · doi:10.1016/j.clnesp.2019.10.018 · Cited by 16
Synthesis of Dynamic Errors Correcting Algorithm for Auto–Balancing Bridge Methods
Khoma, Y., Khoma, V., Podpora, M., Kawala‐Sterniuk, A., Martínek, R., & Ožana, Š. (2020) · IEEE Access · doi:10.1109/access.2020.3022163 · Cited by 16
Zhang, J., Zhang, N., Du, S., Liu, S., & Ma, G. (2021) · Nutrients · doi:10.3390/nu13020553 · Cited by 16
Tsai, M., Cheng, C., & Wang, Y. (2019) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.19-27044 · Cited by 16
In Search of Clinical Impact: Advanced Monitoring Technologies in Daily Heart Failure Care
Nachman, D., Rahamim, E., Kolben, Y., Mengesha, B., Elbaz‐Greener, G., Amir, O., & Asleh, R. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10204692 · Cited by 15
Noninvasive Monitoring to Detect Dehydration: Are We There Yet?
Gray, M. L., Birkenfeld, J., & Butterworth, I. (2023) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121028 · Cited by 15
Faragli, A., Porta, E. L., Herrmann, A., Muzio, F. P. L., Estienne, L., Nigra, S. G., Bellasi, A., Deferrari, G., Ricevuti, G., Somma, S. D., et al. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13216502 · Cited by 15
Apprey, C., Addae, H. Y., Osei, M.-M., Danquah, I., & Annan, R. A. (2025) · BMC Infectious Diseases · doi:10.1186/s12879-024-10395-z · Cited by 15
Hageman, D. J., Wu, S., Kilbreath, S. L., Rockson, S. G., Wang, C., & Tate, M. L. K. (2018) · Trends in biotechnology · doi:10.1016/j.tibtech.2018.02.013 · Cited by 15
Montalibet, A., & McAdams, E. T. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513656 · Cited by 15
Nutritional Status of Men with Ulcerative Colitis in Remission in a Pair–Matched Case–Control Study
Głąbska, D., Guzek, D., & Lech, G. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7110438 · Cited by 15
Logothetis, I., Bayramol, D. V., Gil, I., Dabnichki, P., & Pirogova, E. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/ab78c3 · Cited by 15
Application of Artificial Neural Network to Somatotype Determination
Drywień, M. E., Górnicki, K., & Górnicka, M. (2021) · Applied Sciences · doi:10.3390/app11041365 · Cited by 16
Metrological characterization of a combined bio-impedance plethysmograph and spectrometer
Pittella, E., Piuzzi, E., Rizzuto, E., Pisa, S., & Prete, Z. D. (2018) · Measurement · doi:10.1016/j.measurement.2018.02.032 · Cited by 16
Chinceşan, M. I., Mărginean, C. O., & Voidăzan, S. T. (2016) · Journal of Pediatric Hematology/Oncology · doi:10.1097/mph.0000000000000586 · Cited by 14
French, W. B., & Scott, M. J. (2022) · Anesthesiology Clinics · doi:10.1016/j.anclin.2021.11.002 · Cited by 14
Implantation of an Impedance Sensor for Early Detection of Gastrointestinal Anastomotic Leaks
David, M. M. B., Carmeli, I., Orgad, R., Nathansohn-Levi, B., Yered, T., Shor, E., & Wasserberg, N. (2022) · Journal of Surgical Research · doi:10.1016/j.jss.2022.04.041 · Cited by 14
Mecherques-Carini, M., Esparza-Ros, F., Albaladejo-Saura, M., & Vaquero‐Cristóbal, R. (2022) · Applied Sciences · doi:10.3390/app122413043 · Cited by 16
Hammoud, A., An, T., Briko, A. N., Volkov, A. K., Karapetyan, A., & Shchukin, S. I. (2023) · Biosensors · doi:10.3390/bios13010096 · Cited by 14
Body Composition Outcomes of a Qigong Intervention Among Community-Dwelling Aging Adults
Chang, M.-Y., & Chen, H. (2016) · Western Journal of Nursing Research · doi:10.1177/0193945916654907 · Cited by 14
Bioimpedance as a measure of fluid status in critically ill patients: A systematic review
Madsen, J. M., Wichmann, S., Bestle, M. H., & Itenov, T. S. (2021) · Acta Anaesthesiologica Scandinavica · doi:10.1111/aas.13924 · Cited by 17
Zemlin, C., Stuhlert, C., Schleicher, J. T., Wörmann, C., Altmayer, L. A., Lang, M., Scherer, L.-S., Thul, I. C., Müller, C., Kaiser, E., et al. (2021) · Frontiers in Oncology · doi:10.3389/fonc.2021.762709 · Cited by 14
Georgina Company-Se, Nescolarde, L., Pajares, V., Torregó, A., Riu, P. J., Rosell, J., & Bragós, R. (2021) · IEEE Access · doi:10.1109/access.2021.3139223 · Cited by 14
Live chicken body fat measurement technology based on bio-electrical impedance
Zuo, J., Liang, J., Cheng, S., Deng, Y., Li, Z., Nie, Q., Zhang, D., Zhang, X., Li, Z., & Li, H. (2024) · Computers and Electronics in Agriculture · doi:10.1016/j.compag.2024.108890 · Cited by 14
Flexible bioimpedance spectroscopy system for wound care monitoring
Mc Caffrey, C., Flak, J., Kiri, K., & Pursula, P. (2019) · 2019 IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2019.8919095 · Cited by 14
Phase angle in bioelectrical impedance analysis for assessing congestion in acute heart failure
Sohn, S., Jeon, J., Lee, J. E., Park, S., Kang, D. O., Park, E. J., Lee, D. I., Choi, J. Y., Roh, S. Y., Na, J. O., et al. (2025) · PLoS ONE · doi:10.1371/journal.pone.0317333 · Cited by 13
Muscle Mass Assessment in Sarcopenia: A Narrative Review
Muraki, I. (2023) · JMA Journal · doi:10.31662/jmaj.2023-0053 · Cited by 16
Corona, J. A. A., Calleja-Núñez, J. J., Moncada‐Jiménez, J., & Fernández, J. A. D. P. (2024) · Nutrients · doi:10.3390/nu16142202 · Cited by 17
Marques, C. G., Quaresma, M. V. L. D. S., Ferracini, C. B. F., Carrilho, F. B. A., Nakamoto, F. P., Lucin, G. A., Magalhães, A. C. O., Mendes, G. L., Alvares, L. A. M., & dos Santos, R. V. T. (2024) · Clinical Nutrition · doi:10.1016/j.clnu.2024.12.031 · Cited by 15
An ingestible bioimpedance sensing device for wireless monitoring of epithelial barriers
Holt, B., Stine, J. M., Beardslee, L. A., Ayansola, H., Jin, Y., Pasricha, P. J., & Reza Ghodssi, A. (2025) · Microsystems & Nanoengineering · doi:10.1038/s41378-025-00877-8 · Cited by 13
Body composition of Slovak midlife women with cardiovascular complications
Drozdová, D., Daňková, Z., Čerňanová, V. C., & Siváková, D. (2016) · Anthropological Review · doi:10.1515/anre-2016-0013 · Cited by 13
Serrano, J. M., Huertas, G., Maldonado-Jacobi, A., Olmo, A., Pérez, P., Martín, M. E., Daza, P., & Yúfera, A. (2018) · Sensors · doi:10.3390/s18072354 · Cited by 13
Emran, S., Hurskainen, M., Tomppo, L., Lappalainen, R., Kullaa, A. M., & Myllymaa, S. (2019) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2019.1692940 · Cited by 13
Ogawa, R., Baidillah, M. R., Akita, S., & Takei, M. (2020) · Journal of Electrical Bioimpedance · doi:10.2478/joeb-2020-0004 · Cited by 13
Design of a drop-in EBI sensor probe for abnormal tissue detection in minimally invasive surgery
Zhu, G., Zhou, L. S., Wang, S., Lin, P., Guo, J., Cai, S., Xiong, X., Jiang, X., & Cheng, Z. (2020) · Journal of Electrical Bioimpedance · doi:10.2478/joeb-2020-0013 · Cited by 13
Zhang, L., Zhang, M., Wang, M., Wang, M., Zhang, R., Wang, H., Zhang, W., Ding, Y., & Wang, J. (2022) · European Journal of Gastroenterology & Hepatology · doi:10.1097/meg.0000000000002399 · Cited by 13
Wang, W., Feng, Y., Long, Q., Chen, F., Chen, Y., Ma, M., & Mao, S. (2022) · Frontiers in Neurology · doi:10.3389/fneur.2022.1034894 · Cited by 14
Noninvasive Urinary Bladder Volume Estimation With Artifact-Suppressed Bioimpedance Measurements
Dheman, K., Walser, S., Mayer, P., Eggimann, M., Kozomara, M., Franke, D., Hermanns, T., Sax, H., Schuerle, S., & Magno, M. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3324819 · Cited by 13
Hollander, F. M., Lindeman, Y., de Roos, N. M., Burghard, M., van de Graaf, E. A., & Heijerman, H. G. M. (2019) · Journal of Cystic Fibrosis · doi:10.1016/j.jcf.2019.05.018 · Cited by 13
Sensors for Neonatal Monitoring
Güler, Ü., Sen, D., Costanzo, I., Tufan, T. B., & Rhein, L. M. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00104-7 · Cited by 13
Electrochemical (bio-)sensors operating in human physiological fluids
Psotta, C. (2023) · doi:10.24834/isbn.9789178773992 · Cited by 12
Pena, D.-L., Ilieșiu, A.-M., Aurelian, J., Grigore, M., Hodorogea, A. S., Ciobanu, A., Weiss, E., Bădilă, E., & Balahura, A.-M. (2025) · Medicina · doi:10.3390/medicina61050816 · Cited by 12
Chien, W., Lee, W., Liang, C., Yen, K.-H., Peng, L., Lin, M., Loh, C., Hsiao, F., & Chen, L. (2025) · Journal of Cachexia Sarcopenia and Muscle · doi:10.1002/jcsm.70078 · Cited by 13
Georgina Company-Se, Nescolarde, L., Pajares, V., Torregó, A., Riu, P. J., Rosell, J., & Bragós, R. (2022) · IEEE Access · doi:10.1109/access.2022.3209809 · Cited by 12
Liu, S.-H., Wu, Y.-R., Chen, W., Su, C.-H., & Chin, C.-L. (2023) · Sensors · doi:10.3390/s23042318 · Cited by 12
Jeong, S., BONNER, R., FIRARI, A., Kurti, S. P., Saunders, M. J., & Womack, C. J. (2023) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.23.14913-9 · Cited by 12
Zawieja, E. E., Durkalec‐Michalski, K., Sadowski, M., Główka, N., & Chmurzyńska, A. (2023) · Journal of the International Society of Sports Nutrition · doi:10.1080/15502783.2023.2231411 · Cited by 12
Tryptophan Prevents the Development of Non-Alcoholic Fatty Liver Disease
Yanko, R. V., Levashov, M. I., Chaka, O. G., Nosar, V. I., Khasabov, S. G., & Khasabova, I. A. (2023) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s444278 · Cited by 12
Clement, D. S. V. M., van Leerdam, M. E., Tesselaar, M. E. T., Cananea, E., Martin, W., Weickert, M. O., Sarker, D., Ramage, J. K., & Srirajaskanthan, R. (2024) · Journal of Neuroendocrinology · doi:10.1111/jne.13376 · Cited by 12
Mecherques-Carini, M., Albaladejo-Saura, M., Esparza-Ros, F., Baglietto, N., & Vaquero‐Cristóbal, R. (2025) · Journal of Translational Medicine · doi:10.1186/s12967-024-06062-1 · Cited by 18
Guerrini, A., Siotto, M., Cocco, C., Germanotta, M., Cipollini, V., Cortellini, L., Pavan, A., Lattanzi, S., Insalaco, S., Khazrai, Y. M., et al. (2025) · Scientific Reports · doi:10.1038/s41598-024-84968-y · Cited by 12
The effect of heart pulsatile on the measurement of artery bioimpedance
Abdelbaset, R., Dosoky, M. E., & El-Wakad, M. T. (2017) · Journal of Electrical Bioimpedance · doi:10.5617/jeb.4677 · Cited by 12
Awad, E. Y. A., Ramji, R., Cirovic, S., Rämgård, M., Kottorp, A., & Shleev, S. (2021) · Scientific Reports · doi:10.1038/s41598-021-03262-3 · Cited by 12
Matsumoto, Y., Tada, M., Yamada, Y., Mandai, K., Hidaka, N., & Koike, T. (2022) · Nutrition · doi:10.1016/j.nut.2022.111729 · Cited by 12
Choi, J. W., Yoo, J., Kim, S. G., & Kim, Y. S. (2022) · Healthcare · doi:10.3390/healthcare10112268 · Cited by 13
Riezzo, G., Prospero, L., Orlando, A., Linsalata, M., D’Attoma, B., Ignazzi, A., Giannelli, G., & Russo, F. (2023) · Nutrients · doi:10.3390/nu15061361 · Cited by 15
Metabolic Syndrome Screening and Nutritional Status of Patients with Psoriasis: A Scoping Review
Haris, N. H. M., Krishnasamy, S., Chin, K., Mariappan, V., & Arumugam, M. (2023) · Nutrients · doi:10.3390/nu15122707 · Cited by 13
Santhosh, S., Juliet, A. V., & Krishnan, G. H. (2020) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-020-02452-7 · Cited by 12
RetractedMenegatti, E., Pagani, A., Avruscio, G., Mucignat, M., & Gianesini, S. (2020) · Diagnostics · doi:10.3390/diagnostics10110889 · Cited by 12
Campa, F., Matias, C. N., Nunes, C. L., Monteiro, C. P., Francisco, R., Jesus, F., Marini, E., Sardinha, L. B., Martins, P., Minderico, C. S., et al. (2021) · Biology · doi:10.3390/biology10060524 · Cited by 12
Metadata
- Authors
- Khalil, S., Mohktar, M., & Ibrahim, F.
- Affiliations
- University of Malaya (MY)
- Corresponding author
- Ibrahim, Fatimah
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-06-19
- Volume
- 14
- Issue
- 6
- Pages
- 10895-10928
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC4118362
- OpenAlex
- W2082211146
- Cited by
- 712
- References
- 149
- Citations by year
- 2026: 64 · 2025: 83 · 2024: 91 · 2023: 86 · 2022: 94 · 2021: 72 · 2020: 74 · 2019: 51 · 2018: 48 · 2017: 25 · 2016: 16 · 2015: 7 · 2014: 1
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Body Composition Measurement Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical and Bioimpedance Tomography
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Keywords
- bioelectrical impedance analysis, body composition, bioimpedance vector analysis, prediction equations, anthropometry, lean mass loss, fluid shifts, heart disease, lung disease, kidney disease, neurological disorders, infectious diseases
- MeSH terms
- Body Composition, Diagnosis, Computer-Assisted, Equipment Design, Humans, Models, Biological, Monitoring, Physiologic, Plethysmography, Impedance, Biosensing Techniques, Equipment Failure Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review