The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Dry EEG Electrodes
Open accessAbstract
Electroencephalography (EEG) emerged in the second decade of the 20th century as a technique for recording the neurophysiological response. Since then, there has been little variation in the physical principles that sustain the signal acquisition probes, otherwise called electrodes. Currently, new advances in technology have brought new unexpected fields of applications apart from the clinical, for which new aspects such as usability and gel-free operation are first order priorities. Thanks to new advances in materials and integrated electronic systems technologies, a new generation of dry electrodes has been developed to fulfill the need. In this manuscript, we review current approaches to develop dry EEG electrodes for clinical and other applications, including information about measurement methods and evaluation reports. We conclude that, although a broad and non-homogeneous diversity of approaches has been evaluated without a consensus in procedures and methodology, their performances are not far from those obtained with wet electrodes, which are considered the gold standard, thus enabling the former to be a useful tool in a variety of novel applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Über das Elektrenkephalogramm des Menschen
Berger, H. (1929) · Archiv für Psychiatrie und Nervenkrankheiten · doi:10.1007/bf01797193 · Cited by 4,235
Thermal Agitation of Electric Charge in Conductors
Nyquist, H. (1928) · Physical Review · doi:10.1103/physrev.32.110 · Cited by 3,115
Nunez, P. L., & Srinivasan, R. (2006) · doi:10.1093/acprof:oso/9780195050387.001.0001 · Cited by 2,531
Thermal Agitation of Electricity in Conductors
Johnson, J. B. (1928) · Physical Review · doi:10.1103/physrev.32.97 · Cited by 1,811
Dry-Contact and Noncontact Biopotential Electrodes: Methodological Review
Chi, Y. M., Jung, T.-P., & Cauwenberghs, G. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084078 · Cited by 1,061
Scalp electrode impedance, infection risk, and EEG data quality
Ferree, T. C., Luu, P., Russell, G. S., & Tucker, D. M. (2001) · Clinical Neurophysiology · doi:10.1016/s1388-2457(00)00533-2 · Cited by 1,005
Novel Dry Polymer Foam Electrodes for Long-Term EEG Measurement
Lin, C.-T., Liao, L.-D., Liu, Y.-H., Wang, I.-J., Lin, B.-S., & Chang, J.-Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2102353 · Cited by 336
A 3D printed dry electrode for ECG/EEG recording
Salvo, P., Raedt, R., Carrette, E., Schaubroeck, D., Vanfleteren, J., & Cardon, L. (2012) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2011.12.017 · Cited by 264
Bristle-sensors—low-cost flexible passive dry EEG electrodes for neurofeedback and BCI applications
Grozea, C., Voinescu, C. D., & Fazli, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025008 · Cited by 256
Micromachined electrodes for biopotential measurements
Griss, P., Enoksson, P., Tolvanen-Laakso, H. K., Merilainen, P., Ollmar, S., & Stemme, G. (2001) · Journal of Microelectromechanical Systems · doi:10.1109/84.911086 · Cited by 239
Prutchi, D., & Norris, M. (2004) · Wiley eBooks · doi:10.1002/0471681849 · Cited by 215
Liao, L.-D., Wang, I.-J., Chen, S.-F., Chang, J.-Y., & Lin, C.-T. (2011) · Sensors · doi:10.3390/s110605819 · Cited by 181
A Dry EEG-System for Scientific Research and Brain–Computer Interfaces
Zander, T. O., Lehne, M., Ihme, K. A., Jatzev, S., Correia, J., Kothe, C. A., Picht, B., & Nijboer, F. (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00053 · Cited by 177
van Gerven, M. A. J., & Jensen, O. B. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.01.016 · Cited by 175
A new EEG recording system for passive dry electrodes
Gargiulo, G., Calvo, R. A., Bifulco, P., Cesarelli, M., Jin, C., Mohamed, A., & van Schaik, A. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.12.025 · Cited by 165
BCI meeting 2005-workshop on clinical issues and applications
Kübler, A., Mushahwar, V. K., Hochberg, L. R., & Donoghue, J. P. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875585 · Cited by 158
Characterization of micromachined spiked biopotential electrodes
Griss, P., Tolvanen-Laakso, H., Meriläinen, P., & Stemme, G. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.1001974 · Cited by 149
Non-contact Low Power EEG/ECG Electrode for High Density Wearable Biopotential Sensor Networks
Yu, M., Deiss, S. R., & Cauwenberghs, G. (2009) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2009.52 · Cited by 126
First human trials of a dry electrophysiology sensor using a carbon nanotube array interface
Ruffini, G., Dunne, S., Fuentemilla, L., Grau, C., Farrés, E., Marco‐Pallarés, J., Watts, P. C. P., & Silva, S. R. P. (2008) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2008.03.007 · Cited by 113
Development of a quasi-dry electrode for EEG recording
Mota, A., Duarte, L., Rodrigues, D., Martins, A. C., Machado, A. V., Vaz, F., Fiedler, P., Haueisen, J., Nóbrega, J. M., & Fonseca, C. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.06.013 · Cited by 111
Forvi, E., Bedoni, M., Carabalona, R., Soncini, M., Mazzoleni, P., Rizzo, F., O’Mahony, C., Morasso, C., Cassarà, D. G., & Gramatica, F. (2012) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2012.04.019 · Cited by 91
Dias, N. S., Carmo, J. P., da Silva, A. F., Mendes, P. M., & Correia, J. H. (2010) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2010.09.016 · Cited by 85
Real time workload classification from an ambulatory wireless EEG system using hybrid EEG electrodes
Matthews, R., Turner, P. J., McDonald, N. J., Ermolaev, K., McManus, T., Shelby, R. A., & Steindorf, M. A. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650550 · Cited by 63
RF-sputtering of iridium oxide to be used as stimulation material in functional medical implants
Wessling, B., Mokwa, W., & Schnakenberg, U. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/6/s21 · Cited by 60
Validation of a Dry Electrode System for EEG
Estepp, J. R., Christensen, J. C., Monnin, J. W., Davis, I. M., & Wilson, G. F. (2009) · Proceedings of the Human Factors and Ergonomics Society Annual Meeting · doi:10.1177/154193120905301802 · Cited by 55
Extraction of SSVEP signals of a capacitive EEG helmet for Human Machine Interface
Oehler, M., Neumann, P., Becker, M., Curio, G., & Schilling, M. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650211 · Cited by 43
Effects of electrode properties on EEG measurements and a related inverse problem
Ollikainen, J. O., Vauhkonen, M. J., Karjalainen, P. A., & Kaipio, J. P. (2000) · Medical Engineering & Physics · doi:10.1016/s1350-4533(00)00070-9 · Cited by 38
SSVEP-BCI implementation for 37–40 Hz frequency range
Müller, S. M. T., Díez, P., Bastos-Filho, T., Sarcinelli-Filho, M., Mut, V. A., & Laciar, E. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091568 · Cited by 25
A high performance SSVEP-BCI without gazing
López-Gordo, M. A., Pelayo, F. J., & Prieto, A. (2010) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2010.5596325 · Cited by 19
Auditory Brain-Computer Interfaces for Complete Locked-In Patients
López-Gordo, M. A., Ron-Angevín, R., & Valle, F. P. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-21501-8_47 · Cited by 13
Self-citationPhotrodes for physiological sensing
Kingsley, S. A., Sriram, S., Pollick, A., & Marsh, J. H. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.529473 · Cited by 13
Cited by
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Arnal, P. J., Thorey, V., Debellemaniere, E., Ballard, M. E., Bou Hernandez, A., Guillot, A., Jourde, H., Harris, M., Guillard, M., Van Beers, P., et al. (2020) · SLEEP · doi:10.1093/sleep/zsaa097 · Cited by 394
Norton, J. J. S., Lee, D. S., Lee, J. W., Lee, W., Kwon, O., Won, P., Jung, S.-Y., Cheng, H., Jeong, J.-W., Akce, A., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1424875112 · Cited by 387
Casson, A. J. (2019) · Biomedical Engineering Letters · doi:10.1007/s13534-018-00093-6 · Cited by 340
Metadata
- Authors
- Lopez-Gordo, M., Sanchez-Morillo, D., & Valle, F.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2014-07-18
- Volume
- 14
- Issue
- 7
- Pages
- 12847-12870
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W2061778814
- Cited by
- 410
- References
- 31
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.