Wearable Cardiorespiratory Monitoring Employing a Multimodal Digital Patch Stethoscope: Estimation of ECG, PEP, LVET and Respiration Using a 55 mm Single-Lead ECG and Phonocardiogram
Open accessThe DOI matches its Crossref record; 56 of the 57 references it cites were found in a registry or an index.
Abstract
Cardiovascular diseases are the main cause of death worldwide, with sleep disordered breathing being a further aggravating factor. Respiratory illnesses are the third leading cause of death amongst the noncommunicable diseases. The current COVID-19 pandemic, however, also highlights the impact of communicable respiratory syndromes. In the clinical routine, prolonged postanesthetic respiratory instability worsens the patient outcome. Even though early and continuous, long-term cardiorespiratory monitoring has been proposed or even proven to be beneficial in several situations, implementations thereof are sparse. We employed our recently presented, multimodal patch stethoscope to estimate Einthoven electrocardiogram (ECG) Lead I and II from a single 55 mm ECG lead. Using the stethoscope and ECG subsystems, the pre-ejection period (PEP) and left ventricular ejection time (LVET) were estimated. ECG-derived respiration techniques were used in conjunction with a novel, phonocardiogram-derived respiration approach to extract respiratory parameters. Medical-grade references were the SOMNOmedics SOMNO HDTM and Osypka ICON-CoreTM. In a study including 10 healthy subjects, we analyzed the performances in the supine, lateral, and prone position. Einthoven I and II estimations yielded correlations exceeding 0.97. LVET and PEP estimation errors were 10% and 21%, respectively. Respiratory rates were estimated with mean absolute errors below 1.2 bpm, and the respiratory signal yielded a correlation of 0.66. We conclude that the estimation of ECG, PEP, LVET, and respiratory parameters is feasible using a wearable, multimodal acquisition device and encourage further research in multimodal signal fusion for respiratory signal estimation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures














Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“It is interesting to note that telehealth has been complemented by the use of wearable devices and selfcare equipment, such as glucometers, handheld blood pressure monitors, pulse oximeters, and digital stethoscopes [35,36].”
From Use of Telehealth During the COVID-19 Pandemic: Scoping Review (2020) · cites this paper as [36]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“The ECG R-peak was then detected using the Pan-Tompkins ECG peak detection algorithm [52] .”
MethodBenjafield, A. V., Ayas, N. T., Eastwood, P. R., Heinzer, R., Ip, M. S. M., Morrell, M. J., Nunez, C. M., Patel, S. R., Penzel, T., Pépin, J.-L., et al. (2019) · The Lancet Respiratory Medicine · doi:10.1016/s2213-2600(19)30198-5 · Cited by 4,326 · cited 1×
“At the same time, OSA is one of the most common sleep disorders with an estimated 936 million people affected worldwide [4] .”
BackgroundKapur, V. K., Auckley, D. H., Chowdhuri, S., Kuhlmann, D. C., Mehra, R., Ramar, K., & Harrod, C. G. (2017) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.6506 · Cited by 3,253 · cited 1×
“While the development of an unobtrusive home sleep test system took important steps forward, the expert opinion remains that further research regarding the minimum number of parameters and methods of signal acquisitions is required [34].”
BackgroundCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Fiber‐Based Wearable Electronics: A Review of Materials, Fabrication, Devices, and Applications
Zeng, W., Shu, L., Li, Q., Chen, S., Wang, F., & Tao, X. (2014) · Advanced Materials · doi:10.1002/adma.201400633 · Cited by 2,019
Writing Committee Members, Greenland, P., Alpert, J. S., Beller, G. A., Benjamin, E. J., Budoff, M. J., Fayad, Z. A., Foster, E., Hlatky, M. A., Hodgson, J. M., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3182051b4c · Cited by 1,873
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408 · cited 1×
“Due to a variety of materials available ranging from standard printed circuit boards (PCB) and flexible PCBs to textile integrated electronics [12], implementations of wearable biosignal acquisition systems usually range from sensor shirts over chest straps, wrist-bands, and necklaces, to small adhesive patches implem…”
BackgroundWearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
2010 ACCF/AHA Guideline for Assessment of Cardiovascular Risk in Asymptomatic Adults
Greenland, P., Alpert, J. S., Beller, G. A., Benjamin, E. J., Budoff, M. J., Fayad, Z. A., Foster, E., Hlatky, M. A., Hodgson, J. M., Kushner, F. G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.09.001 · Cited by 1,324
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
The AASM Manual for the Scoring of Sleep and Associated Events : Rules
Iber, C. (2007) · Medical Entomology and Zoology · Cited by 929
Wearable health devices-vital sign monitoring, systems and technologies
Dias, D., & Paulo Silva Cunha, J. (2018) · Sensors · doi:10.3390/s18082414 · Cited by 919 · cited 1×
“Current generations of wearable, noninvasive biosignal acquisition systems can be roughly categorized by their runtime and the physiological parameters of interest [10], as well as their implementation, biosignal selection, and whether or not they are organized into networks [11].”
BackgroundAssociation Between Treated and Untreated Obstructive Sleep Apnea and Risk of Hypertension
Marin, J. M., Agusti, A., Villar, I., Forner, M., Nieto, D., Carrizo, S. J., Barbé, F., Vicente, E., Wei, Y., Nieto, F. J., et al. (2012) · JAMA · doi:10.1001/jama.2012.3418 · Cited by 781
Fernandez-Bustamante, A., Frendl, G., Sprung, J., Kor, D. J., Subramaniam, B., Martinez Ruiz, R., Lee, J.-W., Henderson, W. G., Moss, A., Mehdiratta, N., et al. (2017) · JAMA Surgery · doi:10.1001/jamasurg.2016.4065 · Cited by 653 · cited 1×
“Outbreaks of respiratory syndromes such as severe acute respiratory syndrome (SARS), Middle East respiratory syndrome (MERS), and the currently ongoing COVID-19 pandemic [8] further emphasize the importance of tools for an early diagnosis [9] .”
BackgroundAmsterdam, E. A., Kirk, J. D., Bluemke, D. A., Diercks, D., Farkouh, M. E., Garvey, J. L., Kontos, M. C., McCord, J., Miller, T. D., Morise, A., et al. (2010) · Circulation · doi:10.1161/cir.0b013e3181ec61df · Cited by 609
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
Postoperative Hypoxemia Is Common and Persistent: A Prospective Blinded Observational Study
Sun, Z., Sessler, D. I., Dalton, J. E., Devereaux, P., Shahinyan, A., Naylor, A. J., Hutcherson, M. T., Finnegan, P. S., Tandon, V., Darvish-Kazem, S., et al. (2015) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000000836 · Cited by 341
Ensemble of Feature:based and Deep learning:based Classifiers for Detection of Abnormal Heart Sounds
Potes, C., Parvaneh, S., Rahman, A., & Conroy, B. (2016) · 2016 Computing in Cardiology Conference (CinC) · doi:10.22489/cinc.2016.182-399 · Cited by 314
Recent Advances in Seismocardiography
Taebi, A., Solar, B. E., Bomar, A. J., Sandler, R. H., & Mansy, H. A. (2019) · Vibration · doi:10.3390/vibration2010005 · Cited by 276
Harmon, K. G., Zigman, M., & Drezner, J. A. (2015) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2015.02.001 · Cited by 270
Recent development of respiratory rate measurement technologies
Liu, H., Allen, J., Zheng, D., & Chen, F. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab299e · Cited by 266
Bai, L., Yang, D., Wang, X., Tong, L., Zhu, X., Zhong, N., Bai, C., Powell, C. A., Chen, R., Zhou, J., et al. (2020) · Clinical eHealth · doi:10.1016/j.ceh.2020.03.001 · Cited by 220
Heart sound analysis for symptom detection and computer-aided diagnosis
Reed, T. R., Reed, N. E., & Fritzson, P. (2004) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2003.11.005 · Cited by 192
Cadby, G., McArdle, N., Briffa, T., Hillman, D. R., Simpson, L., Knuiman, M., & Hung, J. (2015) · Chest · doi:10.1378/chest.15-0229 · Cited by 184 · cited 1×
“Especially in the case of obstructive sleep apnea (OSA), close relations to increased CVD such as hypertension [2] and atrial fibrillation [3] have been reported.”
BackgroundLam, T., Nagappa, M., Wong, J., Singh, M., Wong, D., & Chung, F. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002557 · Cited by 182
Langley, P., Bowers, E. J., & Murray, A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2018297 · Cited by 178
Di Rienzo, M., Vaini, E., Castiglioni, P., Merati, G., Meriggi, P., Parati, G., Faini, A., & Rizzo, F. (2013) · Autonomic Neuroscience · doi:10.1016/j.autneu.2013.04.005 · Cited by 163 · cited 1×
“SCG and PCG are closely related [46] , with differences mostly defined by their frequency ranges [47] .”
BackgroundNivitha Varghees, V., & Ramachandran, K. I. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2694970 · Cited by 159
Seismocardiography: Past, present and future
Zanetti, J. M., & Tavakolian, K. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611170 · Cited by 152
Diagnosis of Obstructive Sleep Apnea Syndrome and Its Outcomes With Home Portable Monitoring
de Oliveira, A. C. T., Martinez, D., Vasconcelos, L. F. T., Cadaval Gonçalves, S., do Carmo Lenz, M., Costa Fuchs, S., Gus, M., de Abreu-Silva, E. O., Beltrami Moreira, L., & Danni Fuchs, F. (2009) · Chest · doi:10.1378/chest.08-1859 · Cited by 129
Digital stethoscope: technology update
Swarup, S., & Makaryus, A. (2018) · Medical Devices: Evidence and Research · doi:10.2147/mder.s135882 · Cited by 116
Electrocardiographic Systems With Reduced Numbers of Leads—Synthesis of the 12-Lead ECG
Tomašić, I., & Trobec, R. (2013) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2013.2264282 · Cited by 106
Dehkordi, P., Khosrow-Khavar, F., Rienzo, M. D., Inan, O. T., Schmidt, S. E., Blaber, A. P., Sørensen, K., Struijk, J. J., Zakeri, V., Lombardi, P., et al. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01057 · Cited by 88
Systolic Time Intervals and New Measurement Methods
Tavakolian, K. (2016) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-016-0262-1 · Cited by 75
Analyzing Seismocardiogram Cycles to Identify the Respiratory Phases
Zakeri, V., Akhbardeh, A., Alamdari, N., Fazel-Rezai, R., Paukkunen, M., & Tavakolian, K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2621037 · Cited by 62
Long-term remote monitoring of vital signs using a wireless patch sensor
Selvaraj, N. (2014) · IEEE Healthcare Innovation Conference (HIC) · doi:10.1109/hic.2014.7038880 · Cited by 54
Grouping similar seismocardiographic signals using respiratory information
Taebi, A., & Mansy, H. A. (2017) · IEEE Signal Processing in Medicine and Biology Symposium · doi:10.1109/spmb.2017.8257053 · Cited by 46
Gavrovska, A. M., Zajic, G. J., Reljin, I. S., & Reljin, B. D. (2013) · Computational and Mathematical Methods in Medicine · doi:10.1155/2013/376152 · Cited by 45
Comparison of systolic time interval measurement modalities for portable devices
Carvalho, P., Paiva, R. P., Couceiro, R., Henriques, J. M. O., Antunes, M., Quintal, I., Muehlsteff, J., & Aubert, X. L. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626642 · Cited by 40
Beat-to-beat systolic time-interval measurement from heart sounds and ECG
Paiva, R. P., Carvalho, P., Couceiro, R., Henriques, J. M. O., Antunes, M., Quintal, I., & Muehlsteff, J. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/177 · Cited by 40
Wearable Multimodal Stethoscope Patch for Wireless Biosignal Acquisition and Long-Term Auscultation
Klum, M., Leib, F., Oberschelp, C., Martens, D., Pielmuş, A.-G., Tigges, T., Penzel, T., & Orglmeister, R. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857210 · Cited by 36
Self-citationA comparative study of electronic stethoscopes for cardiac auscultation
Pinto, C., Pereira, D., Ferreira‐Coimbra, J., Português, J., Gama, V., & Coimbra, M. T. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8037392 · Cited by 35
Reconstruction of 12-lead ECG Using a Single-patch Device
Lee, H. J., Lee, D., Kwon, H. B., Kim, D. Y., & Park, K. S. (2017) · Methods of Information in Medicine · doi:10.3414/me16-01-0067 · Cited by 31
Long-term monitoring after surgical ablation for atrial fibrillation: How much is enough?
Edgerton, J. R., Mahoney, C., Mack, M. J., Roper, K. L., & Herbert, M. A. (2011) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2011.01.050 · Cited by 28
A morphological approach to detect respiratory phases of seismocardiogram
Alamdari, N., Tavakolian, K., Zakeri, V., Fazel-Rezai, R., & Akhbardeh, A. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591671 · Cited by 20
Frequent respiratory events in postoperative patients aged 60 years and above
Broens, S. J. L., He, X., Evley, R., Olofsen, E., Niesters, M., Mahajan, R. P., Dahan, A., & van Velzen, M. (2017) · Therapeutics and Clinical Risk Management · doi:10.2147/tcrm.s135923 · Cited by 17
Identification of Human Breathing-States Using Cardiac-Vibrational Signal for m-Health Applications
Choudhary, T., Sharma, L. N., Bhuyan, M. K., & Bora, K. (2020) · IEEE Sensors Journal · doi:10.1109/jsen.2020.3025384 · Cited by 16
Comparing twelve-lead electrocardiography with close-to-heart patch based electrocardiography
Hansen, I. H., Hoppe, K., Gjerde, A., Kanters, J. K., & Sørensen, H. B. D. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318366 · Cited by 15
Effect of Static Respiratory Volume on the Waveform of Cardiac-induced Sternal Vibrations
Skoric, J., D’Mello, Y., Lortie, M. A., Gagnon, S., & Plant, D. V. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8857505 · Cited by 15
Klum, M., Minn, T., Tigges, T., Pielmuş, A.-G., & Orglmeister, R. (2016) · Current Directions in Biomedical Engineering · doi:10.1515/cdbme-2016-0151 · Cited by 10
Self-citationWearable Sensing of Left Ventricular Function
Inan, O. T. (2017) · Springer eBooks · doi:10.1007/978-3-319-51394-2_14 · Cited by 7
Effect of Respiratory Effort Levels on SCG Signals
Choudhary, T., Bhuyan, M. K., & Sharma, L. N. (2019) · IEEE Region 10 Symposium (TENSYMP) · doi:10.1109/tensymp46218.2019.8971092 · Cited by 7
The Implications of the Lead Theory on the Patch ECG Devices Positioning and Measurement
Tomašić, I., Rashkovska, A., Trobec, R., & Lindén, M. (2018) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-9035-6_128 · Cited by 4
PEP and LVET Detection from PCG and ECG
Yang, Y., Chou, Y.-S., & Wang, J. (2019) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-030-30636-6_50 · Cited by 2
Research works printed but not linked: 2
- Choudhary, T., Bhuyan, M., Bora, K., and Sharma, L. (2020). Design of Breathing-states Detector for m-Health Platform using Seismocardiographic Signal. arXiv.
- Klum, 2019, Impedance Plethysmography for Respiratory Flow and Rate Estimation using Multilayer Perceptrons, Int. J. Bioelectromagn., 21, 34
Cited by
Use of Telehealth During the COVID-19 Pandemic: Scoping Review
Doraiswamy, S., Abraham, A., Mamtani, R., & Cheema, S. (2020) · Journal of Medical Internet Research · doi:10.2196/24087 · Cited by 698
Golinelli, D., Boetto, E., Carullo, G., Nuzzolese, A. G., Landini, M. P., & Fantini, M. P. (2020) · Journal of Medical Internet Research · doi:10.2196/22280 · Cited by 574
A Survey on Wearable Technology: History, State-of-the-Art and Current Challenges
Ometov, A., Shubina, V., Klus, L., Skibińska, J., Saafi, S., Pascacio, P., Flueratoru, L., Gaibor, D. Q., Chukhno, N., Chukhno, O., et al. (2021) · Computer Networks · doi:10.1016/j.comnet.2021.108074 · Cited by 506
Wearable Sensing and Telehealth Technology with Potential Applications in the Coronavirus Pandemic
Ding, X., Clifton, D., Ji, N., Lovell, N. H., Bonato, P., Chen, W., Yu, X., Xue, Z., Xiang, T., Long, X., et al. (2021) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2020.2992838 · Cited by 281
“different places of the body [59], [60].”
Recent development of respiratory rate measurement technologies
Liu, H., Allen, J., Zheng, D., & Chen, F. (2019) · Physiological Measurement · doi:10.1088/1361-6579/ab299e · Cited by 266
Metadata
- Authors
- Klum, M., Urban, M., Tigges, T., Pielmus, A.-G., Feldheiser, A., Schmitt, T., & Orglmeister, R.
- Affiliations
- Technische Universität Berlin (DE)
- Department of Electronics and Medical Signal Processing, Technische Universität Berlin, Einsteinufer 17, 10587 Berlin, Germany
- Kliniken Essen-Mitte (DE)
- Corresponding author
- Klum, Michael
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2020-04-04
- Volume
- 20
- Issue
- 7
- Pages
- 2033
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC7180963
- OpenAlex
- W3014676120
- Cited by
- 75
- References
- 57
- Citations by year
- 2026: 5 · 2025: 13 · 2024: 8 · 2023: 13 · 2022: 15 · 2021: 10 · 2020: 10
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DepositOnce (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Informationszentrum Lebenswissenschaften (ZB MED) (submittedVersion, cc-by)
- Technische Universität Berlin – Universitätsbibliothek (cc-by)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Phonocardiography and Auscultation Techniques
- Keywords
- single-lead ECG, ECG-derived respiration, respiratory rate estimation, multimodal signal fusion, sleep-disordered breathing, posture effects
- MeSH terms
- Wearable Electronic Devices, Electrocardiography, Heart Ventricles, Humans, Phonocardiography, Ventricular Function, Respiratory Rate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.