Wearable Devices Suitable for Monitoring Twenty Four Hour Heart Rate Variability in Military Populations
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Heart rate variability (HRV) measurements provide information on the autonomic nervous system and the balance between parasympathetic and sympathetic activity. A high HRV can be advantageous, reflecting the ability of the autonomic nervous system to adapt, whereas a low HRV can be indicative of fatigue, overtraining or health issues. There has been a surge in wearable devices that claim to measure HRV. Some of these include spot measurements, whilst others only record during periods of rest and/or sleep. Few are capable of continuously measuring HRV (≥24 h). We undertook a narrative review of the literature with the aim to determine which currently available wearable devices are capable of measuring continuous, precise HRV measures. The review also aims to evaluate which devices would be suitable in a field setting specific to military populations. The Polar H10 appears to be the most accurate wearable device when compared to criterion measures and even appears to supersede traditional methods during exercise. However, currently, the H10 must be paired with a watch to enable the raw data to be extracted for HRV analysis if users need to avoid using an app (for security or data ownership reasons) which incurs additional cost.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
An overview of heart rate variability metrics and norms
Shaffer, F., & Ginsberg, J. P. (2017) · Frontiers in Public Health · doi:10.3389/fpubh.2017.00258 · Cited by 7,185
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130 · cited 1×
“The ratio of LF:HF was originally deemed to reflect the balance between parasympathetic and sympathetic activity with a low LF:HF reflecting parasympathetic dominance and a high LF:HF indicating sympathetic influence [12] more recently, however, this model has come under scrutiny [13].”
BackgroundStress and Heart Rate Variability: A Meta-Analysis and Review of the Literature
Kim, H.-G., Cheon, E.-J., Bai, D.-S., Lee, Y. H., & Koo, B.-H. (2018) · Psychiatry Investigation · doi:10.30773/pi.2017.08.17 · Cited by 2,308
The LF/HF ratio does not accurately measure cardiac sympatho-vagal balance
Billman, G. E. (2013) · Frontiers in Physiology · doi:10.3389/fphys.2013.00026 · Cited by 1,401
Vagal influence on working memory and attention
Hansen, A. L., Johnsen, B. H., & Thayer, J. F. (2003) · International Journal of Psychophysiology · doi:10.1016/s0167-8760(03)00073-4 · Cited by 759 · cited 1×
“If a cognitive task requires executive functioning, then vagal withdrawal is deemed maladaptive [20].”
BackgroundSassi, R., Cerutti, S., Lombardi, F., Malik, M., Huikuri, H. V., Peng, C.-K., Schmidt, G., Yamamoto, Y., Reviewers:, D., Gorenek, B., et al. (2015) · Europace · doi:10.1093/europace/euv015 · Cited by 727
Investigating sources of inaccuracy in wearable optical heart rate sensors
Bent, B., Goldstein, B. A., Kibbe, W. A., & Dunn, J. P. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0226-6 · Cited by 673
Heart rate variability and cognitive function: a systematic review
Forte, G., Favieri, F., & Casagrande, M. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00710 · Cited by 587 · cited 2×
“This response then reduces the range of possible options and limits an individual’s ability to produce suitable responses and prevent inappropriate ones [18].”
BackgroundRR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise
Gilgen-Ammann, R., Schweizer, T., & Wyss, T. (2019) · European Journal of Applied Physiology · doi:10.1007/s00421-019-04142-5 · Cited by 438 · cited 5×
“[3] is the first and only investigation to validate the Polar H10 at rest and during exercise.”
BackgroundInfluentialCan Wearable Devices Accurately Measure Heart Rate Variability? A Systematic Review
Georgiou, K., Larentzakis, A. V., Khamis, N. N., Alsuhaibani, G. I., Alaska, Y. A., & Giallafos, E. J. (2018) · Folia Medica · doi:10.2478/folmed-2018-0012 · Cited by 244
Kinnunen, H., Rantanen, A., Kenttä, T., & Koskimäki, H. (2020) · Physiological Measurement · doi:10.1088/1361-6579/ab840a · Cited by 184
Validation of the Hexoskin wearable vest during lying, sitting, standing, and walking activities
Villar, R., Beltrame, T., & Hughson, R. L. (2015) · Applied Physiology Nutrition and Metabolism · doi:10.1139/apnm-2015-0140 · Cited by 178 · cited 1×
“Whilst the Hexoskin has been shown to be a valid method to measure and monitor HR [41] even in field conditions [39,42], results for HRV are not so promising.”
MethodBrage, S., Westgate, K., Franks, P. W., Stegle, O., Wright, A., Ekelund, U., & Wareham, N. J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0137206 · Cited by 151 · cited 2×
“The Actiheart has been used in a number of validation studies, but most have involved HR only [33].”
MethodEvaluating the accuracy of heart rate sensors based on photoplethysmography for in-the-wild analysis
Barrios, L., Oldrati, P., Santini, S., & Lutterotti, A. (2019) · Proceedings of the 13th EAI International Conference on Pervasive Computing Technologies for Healthcare · doi:10.1145/3329189.3329215 · Cited by 43 · cited 3×
“In addition, due to the nature of PPG being susceptible to motion noise, there is also gr ater i accuracy during periods of activity [54].”
BackgroundMethodInfluentialAcceptability and usability of an ambulatory health monitoring system for use by military personnel
Tharion, W. J., Buller, M. J., Potter, A. W., Karis, A. J., Goetz, V., & Hoyt, R. W. (2013) · IIE Transactions on Occupational Ergonomics and Human Factors · doi:10.1080/21577323.2013.838195 · Cited by 27 · cited 2×
“When comparing the EQ-01 to the EQ-02, the findings of a survey of 39 US Infantry dismounted soldiers suggest d that the Equivital EQ-02 system provided a better fit (~51%), easier donning (~10%), more comfort (~45%), reduced impact on military performance (~45%), reduced impact on the body (~17%) and was generally mo…”
Result
Cited by
Li, K., Cardoso, C., Moctezuma-Ramirez, A., Elgalad, A., & Perin, E. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20247146 · Cited by 160
“In a study of 38 healthy subjects, vibration treatment (a type of low-frequency sound wave felt as a soothing vibration) from a wearable device improved HRV within 3 min under stress [78].”
BackgroundMethodPalantzas, A., & Anagnostouli, M. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26178217 · Cited by 11
Metadata
- Authors
- Hinde, K., White, G., & Armstrong, N.
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-02-04
- Volume
- 21
- Issue
- 4
- Pages
- 1061
- ISSN
- 1424-8220 (ISSN-L)
- OpenAlex
- W3127340163
- Cited by
- 171
- References
- 16
- FWCI
- 17.41
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.