Wearable Sensor-Based Real-Time Gait Detection: A Systematic Review
Open accessThe DOI matches its Crossref record; 140 of the 140 references it cites were found in a registry or an index.
Abstract
Gait analysis has traditionally been carried out in a laboratory environment using expensive equipment, but, recently, reliable, affordable, and wearable sensors have enabled integration into clinical applications as well as use during activities of daily living. Real-time gait analysis is key to the development of gait rehabilitation techniques and assistive devices such as neuroprostheses. This article presents a systematic review of wearable sensors and techniques used in real-time gait analysis, and their application to pathological gait. From four major scientific databases, we identified 1262 articles of which 113 were analyzed in full-text. We found that heel strike and toe off are the most sought-after gait events. Inertial measurement units (IMU) are the most widely used wearable sensors and the shank and foot are the preferred placements. Insole pressure sensors are the most common sensors for ground-truth validation for IMU-based gait detection. Rule-based techniques relying on threshold or peak detection are the most widely used gait detection method. The heterogeneity of evaluation criteria prevented quantitative performance comparison of all methods. Although most studies predicted that the proposed methods would work on pathological gait, less than one third were validated on such data. Clinical applications of gait detection algorithms were considered, and we recommend a combination of IMU and rule-based methods as an optimal solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


![Figure 1 Word cloud showing most frequently occurring keywords present in search results for a search query in Scopus (for instance, see Table 2), visualized by the software VOS-Viewer [35]. The size of each node indicates the relative relevance (based on the frequency of occurrence of keywords) of that topic among the list of articles returned by the search query. Connections between nodes were not used in refining the search terms.](https://figures.cochat.ai/paper-figures/8276573029d14706b8534ad4cde594cf/wearable-sensor-based-real-time-gait-detection-a-systematic-review-figure-1.jpg)





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The first is methodological heterogeneity in sensor placement, feature extraction, and analysis pipelines across studies, compounded by the absence of task-optimized sensor configurations (Prasanth et al., 2021; Niswander et al., 2020).”
From Multimodal neuroimaging and AI integration in cognitive disorders: advances, challenges, and future directions for precision medicine (2026) · cites this paper as Prasanth et al., 2021
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PRISMA-P Group, Moher, D., Shamseer, L., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., & Stewart, L. A. (2015) · Systematic Reviews · doi:10.1186/2046-4053-4-1 · Cited by 26,223 · cited 1×
“We therefore performed a systematic review and meta-analysis across the four major scientific databases mentioned earlier, following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) standard [21], covering 1262 articles, as will be discussed in the next sections.”
MethodSoftware survey: VOSviewer, a computer program for bibliometric mapping
van Eck, N. J., & Waltman, L. (2010) · Scientometrics · doi:10.1007/s11192-009-0146-3 · Cited by 21,484
Wavelets and signal processing
Rioul, O., & Vetterli, M. (1991) · IEEE Signal Processing Magazine · doi:10.1109/79.91217 · Cited by 2,786
The role of google scholar in evidence reviews and its applicability to grey literature searching
Haddaway, N. R., Collins, A. M., Coughlin, D., & Kirk, S. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138237 · Cited by 2,387 · cited 1×
“[28] classified scientific literature databases into two categories: Academic Citation Database (ACDB) and Academic Citation Search Engine (ACSE).”
BackgroundEstimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068
Nonlinear Complementary Filters on the Special Orthogonal Group
Mahony, R., Hamel, T., & Pflimlin, J.-M. (2008) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2008.923738 · Cited by 1,751
Targeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087 · cited 7×
“We categorized the target impairments into two classes based on how they were presented in the respective studies—first, generally diminished ambulatory function, where gait is impaired due to general degeneration of the locomotor system, such as with Parkinson’s disease, osteoarthritis, Huntington’s disease, diplegic…”
BackgroundInfluentialSelf-citationSpatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814 · cited 1×
“[80] reported that TO and HS events consist of combined features that can be well resolved in the time-frequency domain.”
BackgroundAssessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
VOS: A New Method for Visualizing Similarities between Objects
van Eck, N. J., & Waltman, L. (2006) · RePub (Erasmus University Rotterdam) · Cited by 633
Research works printed but not linked: 1
- Lee, 1994, Wavelet analysis: Theory and applications, Hewlett Packard J., 45, 44
Cited by
Wearable sensors for activity monitoring and motion control: A review
Wang, X., Yu, H., Kold, S., Rahbek, O., & Bai, S. (2023) · Biomimetic Intelligence and Robotics · doi:10.1016/j.birob.2023.100089 · Cited by 213
de Miguel-Fernández, J., Lobo-Prat, J., Prinsen, E. C., Font-Llagunes, J. M., & Marchal–Crespo, L. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01144-5 · Cited by 164
A Survey of Human Gait-Based Artificial Intelligence Applications
Harris, E., Khoo, I., & Demircan, E. (2022) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.749274 · Cited by 165
“, 2018), gait event detection and gait phase recognition (Prasanth et al., 2021), clinical gait diagnostics of knee osteoarthritis (Parisi et al.”
BackgroundSensor-Based Wearable Systems for Monitoring Human Motion and Posture: A Review
Huang, X., Xue, Y., Ren, S., & Wang, F. (2023) · Sensors · doi:10.3390/s23229047 · Cited by 166
Huang, T.-H., Zhang, S., Yu, S., MacLean, M. K., Zhu, J., Lallo, A. D., Jiao, C., Bulea, T. C., Zheng, M., & Su, H. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3170287 · Cited by 95
“Traditional high-level exoskeleton controllers cannot accurately produce biological joint moment patterns and adapt to changes in walking patterns [20], [31].”
BackgroundWei, S., & Wu, Z. (2023) · Sensors · doi:10.3390/s23187667 · Cited by 142
“Wearable sensors are an important technology for gait analysis, diagnosing walking disorders in patients with gait disorders, and gait analysis is very important for the clinical assessment of patient rehabilitation [4].”
BackgroundAn IMU-Based Real-Time Gait Detection Method for Intelligent Control of Knee Assistive Devices
Lu, Y., Zhu, J., Chen, W., & Ma, X. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3329222 · Cited by 99
“However, given that machine learning approaches often run large amounts of iterative steps (i.e., testing process), this will cause a time delay and instability of gait detection [20], [21], especially for portable platforms with limited computing performance.”
BackgroundA spinal cord neuroprosthesis for locomotor deficits due to Parkinson’s disease
Milekovic, T., Moraud, E. M., Macellari, N., Moerman, C., Raschellà, F., Sun, S., Perich, M. G., Varescon, C., Demesmaeker, R., Bruel, A., et al. (2023) · Nature Medicine · doi:10.1038/s41591-023-02584-1 · Cited by 98
“Unlike NHPs, people tolerate wearable sensors attached to their limbs 48 .”
BackgroundSelf-citationToward Gait Symmetry Enhancement via a Cable-Driven Exoskeleton Powered by Series Elastic Actuators
Zhong, B., Guo, K., Yu, H., & Zhang, M. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3130639 · Cited by 89
Information-Aided Inertial Navigation: A Review
Engelsman, D., & Klein, I. (2023) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2023.3303496 · Cited by 104
A Novel Tool for Gait Analysis: Validation Study of the Smart Insole PODOSmart®
Ziagkas, E., Loukovitis, A., Zekakos, D. X., Chau, T. D.-P., Petrelis, A., & Grouios, G. (2021) · Sensors · doi:10.3390/s21175972 · Cited by 59
“Additionally, gait events such as heel strike or toe off may be computed using technics such as rule-based methods, machine learning or wavelet transform [13].”
BackgroundMethodInteractive Control of Lower Limb Exoskeleton Robots: A Review
Zhang, Y.-P., Cao, G.-Z., Li, L.-L., & Diao, D.-F. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3352005 · Cited by 58
“One is to use biomechanical signals [47], [55], [56], [57], [58], [59], such as by using acceleration signals to identify human gait patterns [60], [61], [62], [63] or by using plantar pressure signals [64], [65], [66], force myography (FMG) [67], or mechanomyography (MMG) [68], [69] to identify…”
MethodA Systematic Review of Insole Sensor Technology: Recent Studies and Future Directions
Santos, V. M., Gomes, B. B., Neto, M. A., & Amaro, A. M. (2024) · Applied Sciences · doi:10.3390/app14146085 · Cited by 51
Gait analysis to monitor fracture healing of the lower leg
Warmerdam, E., Orth, M., Pohlemann, T., & Ganse, B. (2023) · Bioengineering · doi:10.3390/bioengineering10020255 · Cited by 47
“These have already been used frequently in other patient groups for continuous measurements [75].”
A 3D-Printed Capacitive Smart Insole for Plantar Pressure Monitoring
Samarentsis, A. G., Makris, G., Spinthaki, S., Christodoulakis, G., Tsiknakis, M., & Pantazis, A. K. (2022) · Sensors · doi:10.3390/s22249725 · Cited by 49
“Most often, they are used to measure the plantar pressure distribution, despite the fact that other gate features can also be obtained, including the center-of-pressure (CoP), step count, duration of gait cycle, swing and stance duration [19].”
BackgroundEvaluating Gait Impairment in Parkinson’s Disease from Instrumented Insole and IMU Sensor Data
Tsakanikas, V., Ntanis, A., Rigas, G., Androutsos, C., Boucharas, D. G., Tachos, N. S., Skaramagkas, V., Chatzaki, C., Kefalopoulou, Z. M., Tsiknakis, M., et al. (2023) · Sensors · doi:10.3390/s23083902 · Cited by 58
“The latter approach provides even richer motion data by combining the strength of both sensors [15].”
BackgroundMethodDeep Learning Approaches for Enhanced Lower-Limb Exoskeleton Control: A Review
Belal, M., Alsheikh, N., Aljarah, A., & Hussain, I. (2024) · IEEE Access · doi:10.1109/access.2024.3414175 · Cited by 42
“Restrictions apply. efficiently and accurately [42], [167], [168].”
BackgroundEnergy-aware human activity recognition for wearable devices: A comprehensive review
Contoli, C., Freschi, V., & Lattanzi, E. (2024) · Pervasive and Mobile Computing · doi:10.1016/j.pmcj.2024.101976 · Cited by 55
Accuracy validation of a wearable IMU-based gait analysis in healthy female
He, Y., Chen, Y., Tang, L., Chen, J., Tang, J., Yang, X., Su, S., Zhao, C., & Xiao, N. (2024) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-023-00792-3 · Cited by 49
IMU-Based Monitoring for Assistive Diagnosis and Management of IoHT: A Review
Bo, F., Yerebakan, M., Dai, Y., Wang, W., Li, J., Hu, B., & Gao, S. (2022) · Healthcare · doi:10.3390/healthcare10071210 · Cited by 35
“Similar to the categorization of the disorders in [26,27], the articles included in this review Similar to the categorization of the disorders in [26,27], the articles included in this review can be classified into four main categories based on movement-related medical conditions in regard to…”
Voisard, C., de l′Escalopier, N., Ricard, D., & Oudre, L. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01405-x · Cited by 35
Jacobs, D., Farid, L., Ferré, S., Herraez, K., Graciès, J., & Hutin, É. (2021) · Sensors · doi:10.3390/s21196543 · Cited by 39
“This is supported by the fact that the majority of devices with IMU were compared to pressure sensors for the validation of temporal gait events [19].”
Brognara, L., Mazzotti, A., Martino, A. C. D., Faldini, C., & Cauli, O. (2021) · Medicina · doi:10.3390/medicina57111145 · Cited by 36
Current State of Data and Analytics Research in Baseball
Mizels, J., Erickson, B. J., & Chalmers, P. N. (2022) · Current Reviews in Musculoskeletal Medicine · doi:10.1007/s12178-022-09763-6 · Cited by 34
“IMUs have already demonstrated utility in gait analysis [53 – 55] and are currently being used to analyze pitching mechanics [50, 52, 53, 56 – 61].”
MethodReal-Time Gait Phase Detection on Wearable Devices for Real-World Free-Living Gait
Wu, J., Becsek, B. E. M., Schaer, A., Maurenbrecher, H., Chatzipirpiridis, G., Ergeneman, O., Pané, S., Torun, H., & Nelson, B. J. (2022) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2022.3228329 · Cited by 41
“rising and falling signal edges have appeared, which may cause a significant delay, on the order of hundreds of milliseconds [7].”
BackgroundAdvances in Functionalized Applications of Graphene‐Based Wearable Sensors in Healthcare
Akter, M., Anik, H. R., Tushar, S. I., Tania, I. S., Chowdhury, M. K. H., Hasan, M., & Bristy, B. F. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202300120 · Cited by 38
Gait Pattern Recognition Based on Plantar Pressure Signals and Acceleration Signals
Zhang, M., Liu, D., Wang, Q., Zhao, B., Bai, O., & Sun, J. (2022) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2022.3204088 · Cited by 33
“In addition, wavelets are considered 410 to be more suitable for rapid motion transitions [32] (for 411 instance, examining unsteady signals such as sitting–rising 412 pattern [33]) as well as accurately detecting falls and ADL 413 of the elderly [34].”
BackgroundSzabo, D. A., Neagu, N. E., Teodorescu, S., Apostu, M., Predescu, C., Pârvu, C., & Veres, C. (2023) · Sensors · doi:10.3390/s23218950 · Cited by 46
“Prasanth et al. (2021) [74] conducted a comprehensive study to investigate the sensor-based methodologies that were used for real-time gait analysis.”
Background3D-Printed Piezoelectric PLA-Based Insole for Event Detection in Gait Analysis
Latsch, B., Schäfer, N., Grimmer, M., Dali, O. B., Mohseni, O., Bleichner, N., Altmann, A. A., Schaumann, S., Wolf, S. I., Seyfarth, A., et al. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3416847 · Cited by 36
“Regardless of improvements in the read-out and the design of piezoresistive sensors [21], [47], [48], the general quality compared to other sensor technologies regarding creep, accuracy, and repeatability is low [49], [50], [51].”
BackgroundElectromyography Signal Acquisition, Filtering, and Data Analysis for Exoskeleton Development
Sul, J.-H., Piyathilaka, L., Moratuwage, D., Arachchige, S. D., Jayawardena, A., Kahandawa, G. C., & Preethichandra, D. M. G. (2025) · Sensors · doi:10.3390/s25134004 · Cited by 55
“Moreover, communication delays, particularly in wireless setups, must be minimized using protocols like BLE or Wi-Fi Direct, which require tight synchronization between sensor nodes and processing units [119].”
Machine Learning Based Abnormal Gait Classification with IMU Considering Joint Impairment
Hwang, S., Kim, J., Yang, S., Moon, H.-J., Cho, K., Youn, I., Sung, J.-K., & Han, S. (2024) · Sensors · doi:10.3390/s24175571 · Cited by 32
“To overcome these issues, numerous studies utilizing wearable sensors have been proposed, among which research employing inertial measurement unit (IMU) has reported high usability and excellent performance [13,14].”
BackgroundCo-simulation of human digital twins and wearable inertial sensors to analyse gait event estimation
Uhlenberg, L., Derungs, A., & Amft, O. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1104000 · Cited by 36
“Indeed, recent publications show that rule-based algorithms with parameterised thresholds are actively deployed for gait phase detection (Vu et al., 2020; Prasanth et al., 2021).”
BackgroundXu, S., Li, C., Wei, C., Kang, X., Shu, S., Liu, G., Xu, Z., Han, M., Luo, J., & Tang, W. (2024) · Advanced Science · doi:10.1002/advs.202304763 · Cited by 30
Salminen, M., Perttunen, J., Avela, J., & Vehkaoja, A. T. (2024) · Gait & Posture · doi:10.1016/j.gaitpost.2024.04.006 · Cited by 27
Deep Learning for Quantified Gait Analysis: A Systematic Literature Review
Khan, A., C., O. A. G., Garcia-Salicetti, S., & Vigneron, V. (2024) · IEEE Access · doi:10.1109/access.2024.3434513 · Cited by 40
“It is now feasible to evaluate gait outside of the lab using wearable sensor systems because of recent significant advancements in sensor systems and computational techniques [16], [17].”
BackgroundMethodRevi, D. A., Rossi, S., Walsh, C. J., & Awad, L. N. (2021) · Sensors · doi:10.3390/s21216976 · Cited by 26
Gait Alterations in Adults after Ankle Fracture: A Systematic Review
Mirando, M., Conti, C., Zeni, F., Pedicini, F., Nardone, A., & Pavese, C. (2022) · Diagnostics · doi:10.3390/diagnostics12010199 · Cited by 26
“IMUs have opened the way to clinical applications in different diseases as well as measurement of activities of daily living [21].”
BackgroundMethodIslam, M. S., Tabassum, M., Nishat, M. M., Faisal, F., & Hasan, M. S. (2022) · International Conference on Business and Industrial Research (ICBIR) · doi:10.1109/icbir54589.2022.9786472 · Cited by 26
Biomechanics Parameters of Gait Analysis to Characterize Parkinson’s Disease: A Scoping Review
Russo, M., Amboni, M., Pisani, N., Volzone, A., Calderone, D., Barone, P., Amato, F., Ricciardi, C., & Romano, M. (2025) · Sensors · doi:10.3390/s25020338 · Cited by 37
Validation of portable in-clinic video-based gait analysis for prosthesis users
Cimorelli, A., Patel, A., Karakostas, T. E., & Cotton, R. J. (2024) · Scientific Reports · doi:10.1038/s41598-024-53217-7 · Cited by 41
Adaptive neural fuzzy reasoning method for recognizing human movement gait phase
Song, J., Zhu, A., Tu, Y., Mao, H., & Zhang, X. (2022) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2022.104087 · Cited by 23
Evaluation of Hemiplegic Gait Based on Plantar Pressure and Inertial Sensors
Pan, Z., Gao, H., Chen, Y., Xie, Z., & Xie, L. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3268669 · Cited by 23
Zhou, C., Feng, D., Chen, S., Ban, N., & Pan, J. (2023) · Expert Systems with Applications · doi:10.1016/j.eswa.2023.122074 · Cited by 28
Sonification for Personalised Gait Intervention
Wall, C., McMeekin, P. J., Walker, R. W., Hetherington, V., Graham, L., & Godfrey, A. (2023) · Sensors · doi:10.3390/s24010065 · Cited by 24
“Real-time sensing offers clinicians and patients valuable insights into the efficacy of rehabilitation strategies which could then be immediately adjusted to optimize gait [25].”
BackgroundKumar, R. R., Sporn, K., Paladugu, P., Khanna, A., Gowda, C., Ngo, A., Waisberg, E., Ong, J., Jagadeesan, R., & Tavakkoli, A. (2025) · Diagnostics · doi:10.3390/diagnostics15131648 · Cited by 32
“Objective assessment of gait using inertial measurement units (IMUs), wearable sensors combining accelerometers, gyroscopes, and magnetometers, has shown great promise for functional evaluations in individuals with knee osteoarthritis [135].”
Fary, C., Cholewa, J. M., Abshagen, S., Andel, D. V., Ren, A. N., Anderson, M. B., & Tripuraneni, K. R. (2023) · Sensors · doi:10.3390/s23125588 · Cited by 24
“The use of commercially available sensor-based technologies allows for gait analysis during activities of daily living [34] and has the potential to allow for clinician monitoring, timely feedback, and the identification of poor recovery prognosis in the early post-operative period.”
A Review of Gait Analysis Using Gyroscopes and Inertial Measurement Units
Lin, S., Evans, K. A., Hartley, D., Morrison, S., McDonald, S., Veidt, M., & Wang, G. (2025) · Sensors · doi:10.3390/s25113481 · Cited by 20
“Several reviews have addressed gait events or gait phases using wearable sensors for different purposes [28,29,31,33,34].”
Lora-Millán, J. S., Hidalgo, A. F., & Rocón, E. (2021) · IEEE Access · doi:10.1109/access.2021.3122160 · Cited by 20
“Several authors have worked on gait event detection and gait segmentation [42], [43], and Prasanth et al. presented an extensive review of these methods in [44]; however, some of them have not been validated as controllers for robotic wearable devices, so they are out of the scope of this work.”
BackgroundLanotte, F., Shin, S. Y., O’Brien, M. K., & Jayaraman, A. (2023) · Physiological Measurement · doi:10.1088/1361-6579/aceecf · Cited by 24
Cai, S., Shao, M., Du, M., Bao, G., & Fan, B. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3229384 · Cited by 20
“In addition, as a wearable sensor, compared with the optical motion capture (OMC), IMC has the advantage of portability and low cost, which has the potential to be used outdoors [4], [9], [10], [11], [12].”
BackgroundWearable Movement Sensors for Rehabilitation: From Technology to Clinical Practice
Regterschot, G. R. H., Ribbers, G. M., & Bussmann, J. B. J. (2021) · Sensors · doi:10.3390/s21144744 · Cited by 20
“(2021) [10] performed a systematic review of sensor-based methods applied for real-time gait analysis.”
BackgroundJabri, S., Carender, W. J., Wiens, J., & Sienko, K. H. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01099-z · Cited by 20
“The choice of IMU placement on different body segments was shown to have an effect on model performance in the context of gait-based classification of stroke and other neurological disorders [36], and the choice of IMU placement on a given body segment was shown to affect the accuracy of estimated spatio-temporal gait…”
BackgroundJacobsen, N. S. J., Blum, S., Scanlon, J. E. M., Witt, K., & Debener, S. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.945341 · Cited by 21
Hendriks, M. M. S., der Hulst, M. V.-V., Weijs, R. W. J., van Lotringen, J. H., Geurts, A. C. H., & Keijsers, N. (2022) · Sensors · doi:10.3390/s22218387 · Cited by 26
“Because measuring pathological gait with IMUs in daily life remains challenging [25,32], our first aim was to validate our IMU-based gait algorithm in rehabilitation inpatients with stroke or iSCI.”
BackgroundMethodInfluentialMeng, W., Zhu, C. J., Liu, H., Liu, Q., & Xie, S. Q. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3385798 · Cited by 22
“Human-robot state information mainly includes kinematic information, kinetic information, and physiological information, which can be obtained from the pressure-sensitive insole, FSR [82], [83], [84], encoder, IMU [85], [86], load cell [87], [88], and EMG sensor [89], [90], [91], [92].”
BackgroundMethodMoon, J., Lee, D., Jung, H., Choi, A., & Mun, J. H. (2022) · Sensors · doi:10.3390/s22093499 · Cited by 22
“Inertial measurement units (IMU) and smart insole systems are representative wearable sensor devices that have the advantage of being able to analyze human body motion using realtime temporal information [15].”
BackgroundÖzden, F. (2022) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2022.107579 · Cited by 20
Enhancing Intelligent Shoes with Gait Analysis: A Review on the Spatiotemporal Estimation Techniques
Joseph, A. M., Kian, A., & Begg, R. K. (2024) · Sensors · doi:10.3390/s24247880 · Cited by 22
“For upper limb motion analysis, sensors are typically attached to the trunk, back, scapula, lumbar region, upper arm, forearm, and hand, while for lower limb motion, they are placed on the trunk, lower back, sacrum, hip, pelvis, thigh, shank, and feet [13].”
InfluentialLiu, X., Chen, M., Liang, T., Lou, C., Wang, H., & Liu, X. (2021) · Mathematical Biosciences & Engineering · doi:10.3934/mbe.2022055 · Cited by 20
Bissenov, A., Zhubi, E., Engh, M. A., Gresits, O., Tóth, R., & Terebessy, T. (2025) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-025-06322-w · Cited by 22
Strick, J. A., Farris, R. J., & Sawicki, J. T. (2024) · Journal of Biomechanical Engineering · doi:10.1115/1.4064435 · Cited by 17
Brognara, L., Mazzotti, A., Zielli, S. O., Arceri, A., Artioli, E., Traina, F., & Faldini, C. (2024) · Sensors · doi:10.3390/s24217059 · Cited by 24
“Several authors have shown good to excellent validity and reliability of measurements such as step length, stance time, and stride length across various sensor placements (e.g., back, shank, foot) [64,65].”
BackgroundA Comparative Evaluation of Inertial Sensors for Gait and Jump Analysis
Andrenacci, I., Boccaccini, R., Bolzoni, A., Colavolpe, G., Costantino, C., Federico, M., Ugolini, A., & Vannucci, A. (2021) · Sensors · doi:10.3390/s21185990 · Cited by 15
“We refer the reader to the papers [2,3] and the references therein for a review of the most recent results on the use of inertial sensor for motion analysis.”
MethodLencioni, T., Meloni, M., Bowman, T., Marzegan, A., Caronni, A., Carpinella, I., Castagna, A., Gower, V., Ferrarin, M., & Pelosin, E. (2022) · Sensors · doi:10.3390/s22072668 · Cited by 18
“Moreover, it is worth considering that recently, IMUs have been used for evaluating GI and the APA with a fair success [14,15].”
MethodInfluentialEnhanced gait tracking measures for individuals with stroke using leg-worn inertial sensors
Lanotte, F., Okita, S., O’Brien, M. K., & Jayaraman, A. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01521-8 · Cited by 24
“Various measurement systems have been proposed for this purpose, including plantar pressure measurement [38], optical motion capture systems [39], camera-based computer vision systems [40], and IMUs [23, 41].”
Dvorani, A., Waldheim, V., Jochner, M. C. E., Salchow-Hömmen, C., Meyer-Ohle, J., Kühn, A. A., Wenger, N., & Schauer, T. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.720516 · Cited by 16
“A review of methods for gait phase detection can be found in (20).”
MethodReal-Time Gait Event Detection with Adaptive Frequency Oscillators From a Single Head-Mounted IMU
Tomc, M., & Matjačić, Z. (2023) · Sensors · doi:10.3390/s23125500 · Cited by 20
“This is comparable to the average number of participants in other studies in the field [6].”
BackgroundResultInfluentialPlaza-Bravo, J. M., Mateo‐March, M., Sanchís-Sanchís, R., Pérez‐Soriano, P., Zabala, M., & Martínez, A. E. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19148375 · Cited by 16
“At present, this type of technology is widely used, and currently, this type of device is becoming more and more frequent in the analysis of different joint angles [7] applied to human gait [8], especially to analyze heel strike and toe off [9], in the running analysis [10,11], in weightlifting to measure barbell spee…”
BackgroundCui, G., & Wang, C. (2025) · PLoS ONE · doi:10.1371/journal.pone.0317414 · Cited by 18
Validation of Running Gait Event Detection Algorithms in a Semi-Uncontrolled Environment
Donahue, S. R., & Hahn, M. E. (2022) · Sensors · doi:10.3390/s22093452 · Cited by 13
“Previous studies have shown the efficacy of utilizing mobile sensing units for the detection of gait events inside and outside the laboratory, as the baseline information needed for biomechanical analysis [6,7].”
BackgroundBrasiliano, P., Mascia, G., Feo, P. D., Stanislao, E. D., Alvini, M., Vannozzi, G., & Camomilla, V. (2023) · Micromachines · doi:10.3390/mi14020277 · Cited by 14
“Although most studies hypothesized that the proposed methods would work on pathological gait, less than one third were validated on such data [27] and only two considered a pediatric population presenting toe walking [30,31].”
BackgroundWei, J. Z., Cheung, B. K. C., Chu, S. L. H., Tsang, P. Y. L., To, M. K.-T., Lau, J. Y. N., & Cheung, K. (2023) · Spine Deformity · doi:10.1007/s43390-023-00737-3 · Cited by 14
“1), which are motion sensors that have been widely used in different electronics like smartphone and wearables, and medical device for gait analysis and rehabilitation [20, 21].”
BackgroundGait Event Detection Based on Fuzzy Logic Model by Using IMU Signals of Lower Limbs
Liu, Y., Liu, Y., Song, Q., Wu, D., & Jin, D. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3406596 · Cited by 13
“G AIT event recognition was useful for adjusting the motion control strategies of the wearable exoskeleton robots to achieve more precise and effective assistance [1].”
MethodBach, M. M., Dominici, N., & Daffertshofer, A. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.1037438 · Cited by 20
Olsen, S., Rashid, U., Barbado, D., Suresh, P., Alder, G., Niazi, I. K., & Taylor, D. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111899 · Cited by 12
Promsri, A., Pitiwattanakulchai, P., Saodan, S., & Thiwan, S. (2024) · Sensors · doi:10.3390/s24216846 · Cited by 17
“Measuring body acceleration can, thus, effectively analyze human movements such as gait [23] and postural control [24,25].”
BackgroundGait Spatio-Temporal Parameters Vary Significantly Between Indoor, Outdoor and Different Surfaces
Brognara, L., Arceri, A., Zironi, M., Traina, F., Faldini, C., & Mazzotti, A. (2025) · Sensors · doi:10.3390/s25051314 · Cited by 12
“Recent technological advancements have led to affordable, wearable sensors for gait analysis in everyday settings [16].”
Bandara, A., Shimizu, H., Watanabe, D., Misa, T., Suzuki, S., Tanigawa, K., Nagai‐Tanima, M., & Aoyama, T. (2025) · Scientific Reports · doi:10.1038/s41598-025-91617-5 · Cited by 14
Ng, G., & Andrysek, J. (2023) · Sensors · doi:10.3390/s23031412 · Cited by 17
“Inertial sensors are highly flexible in their placement and configuration [6,45], and developing algorithms to leverage the data from these can support the design of compact wearable systems for gait monitoring.”
BackgroundEffect of Walking Speed on the Reliability of a Smartphone-Based Markerless Gait Analysis System
de Borba, E. F., Storniolo, J. L., Cerfoglio, S., Capodaglio, P., Cimolin, V., Peyré‐Tartaruga, L. A., Tartaruga, M. P., & Cavallari, P. (2025) · Sensors · doi:10.3390/s25206474 · Cited by 12
“Although new devices have been introduced to the market in recent years to address this issue, utilizing simple mechanisms such as accelerometers [5], they still require costly options for use in daily clinical settings.”
Effects of Mobile Phone Use on Gait and Balance Control in Young Adults: A Hip–Ankle Strategy
Lu, Z., Zhang, X., Mao, C., Liu, T., Li, X., Zhu, W., Wang, C., & Sun, Y. L. (2023) · Bioengineering · doi:10.3390/bioengineering10060665 · Cited by 11
Bao, T., Gao, J., Wang, J., Yang, C., Xu, F., Qiao, G., & Li, F. (2023) · Frontiers in Robotics and AI · doi:10.3389/frobt.2023.1265543 · Cited by 20
Jiang, X., Li, J., Zhu, Z., Liu, X., Yuan, Y., Chou, C.-H., Yan, S., Dai, C., & Jia, F. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3429637 · Cited by 11
“The insole pressure is an acceptable modality used as gold standard in wearable sensing [17].”
MethodSmartCare—A comprehensive wearable sensor-based remote health monitoring and rehabilitation system
Raja, G. B. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-21505-6.00011-6 · Cited by 13
Bradley, M., O’Loughlin, S., Donlon, E., Gallagher, A., O’Keeffe, C., Inocentes, J., Ruggieri, F., Reilly, R. B., Walsh, R. A., Lynch, T., et al. (2025) · Sensors · doi:10.3390/s25134071 · Cited by 11
“Inertial measurement units (IMUs) typically consist of an accelerometer (measures acceleration), a magnetometer (orientation), and a gyroscope (angle and angular velocity) [13].”
A Smart Walking Stick for Gait Analysis of Elderly and People With Disabilities
Zhou, J., Li, W., Zhang, Q., Xie, F., & Wang, Q. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3161992 · Cited by 13
Physiological and Biomechanical Monitoring in American Football Players: A Scoping Review
Nocera, A., Sbrollini, A., Romagnoli, S., Morettini, M., Gambi, E., & Burattini, L. (2023) · Sensors · doi:10.3390/s23073538 · Cited by 12
“Wearables could solve this issue, and foot-mounted or shoe-mounted wearable devices are already available to provide valuable information regarding running gait mechanics [169,170].”
BackgroundGait Synergy Analysis and Modeling on Amputees and Stroke Patients for Lower Limb Assistive Devices
Liang, F., Gao, F., Cao, J., Law, S. W., & Liao, W. (2022) · Sensors · doi:10.3390/s22134814 · Cited by 13
Portable in-clinic video-based gait analysis: validation study on prosthetic usersPreprint
Cimorelli, A., Patel, A., Karakostas, T. E., & Cotton, R. J. (2022) · medRxiv · doi:10.1101/2022.11.10.22282089 · Cited by 11
“(3) Then we perform top-down 2D keypoints detection in each frame using the MMPose toolbox (31), specifically using an HRNet (32) trained on the COCO dataset (33) using distribution aware relative keypoints (34), (4) the 2D keypoint trajectories are then lifted to 3D joint locations (35).”
MethodDeep learning for human locomotion analysis in lower-limb exoskeletons: a comparative study
Coser, O., Tamantini, C., Tortora, M., Furia, L., Sicilia, R., Zollo, L., & Soda, P. (2025) · Frontiers in Computer Science · doi:10.3389/fcomp.2025.1597143 · Cited by 15
“These insights underscore the critical role of foot sensors in capturing essential gyroscope and acceleration data during gait [28].”
Automatic gait EVENT detection in older adults during perturbed walking
Wang, S., Omar, K. S., Miranda, F., & Bhatt, T. S. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01560-9 · Cited by 12
“Gait event detection is a fundamental component of gait analysis, crucial for the quantitative assessment of spatiotemporal characteristics during both regular and perturbed walking [1, 2].”
Analysis of Human Gait Cycle With Body Equilibrium Based on Leg Orientation
Asif, M., Tayyab, M. A., Shahid, M. H., Arif, U., Tiwana, M. I., Khan, U. S., & Qureshi, W. S. (2022) · IEEE Access · doi:10.1109/access.2022.3222859 · Cited by 14
“Both IMUs (inertial measurement unit) and rule-based methods are the optimal choices for gait analysis [1].”
MethodMethods for Spatiotemporal Analysis of Human Gait Based on Data from Depth Sensors
Wagner, J., Szymański, M., Błażkiewicz, M., & Kaczmarczyk, K. (2023) · Sensors · doi:10.3390/s23031218 · Cited by 10
“Wearable sensors—such as inertial measurement units or pressure-sensing foot insoles—have also been used in commercially available gait-analysis systems and research studies [17].”
BackgroundMethodWang, Z., Pang, J., Tao, P., Ji, Z., Chen, J., Meng, L., Xu, R., & Ming, D. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.106105 · Cited by 12
Analysis of Gait Pattern Related to Cerebral Small Vessel Disease Using Wearable Sensors
Xu, K., Wang, Y., Jiang, Y., Wang, Y., Li, P., Lu, H., Suo, C., Yuan, Z., Yang, Q., Dong, Q., et al. (2022) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108162 · Cited by 12
Lozano‐García, M., Doheny, E. P., Mann, E., Morgan-Jones, P., Drew, C. J. G., Busse, M. E., & Lowery, M. M. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3407887 · Cited by 11
“These methods use either heuristically defined thresholds or peak detection techniques on the acceleration or angular velocity signal to detect gait events [23].”
BackgroundMethodInfluentialAlgorithm for Gait Parameters Estimation Based on Heel-Mounted Inertial Sensors
Luo, B., Wang, Z., Wang, D., Chen, L., & Ma, X. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3410402 · Cited by 9
“Our algorithm employed the peak detection method, a common technique for gait event detection and segmentation [34], to detect stride segments and gait events.”
MethodCotrobaș-Dascălu, V.-T., Bădău, D., Stoica, M., Dreve, A., Predescu, C. M. L., Gherghel, C. L., Bratu, M., Popescu, R., Oltean, A., & Bădău, A. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11144108 · Cited by 9
Izmailova, E. S., Middleton, D., Yunis, R., Lakeland, J., Sowalsky, K. L., Kling, J., Ritchie, A., Guo, C. C., Byrom, B., & Kern, S. (2024) · Clinical and Translational Science · doi:10.1111/cts.70054 · Cited by 11
“…assessed using body-worn sensors, and there are multiple options available in terms of the number of sensors deployed, 59 body placement, and form factors 60 either for passive monitoring in free living settings or during performance of active tasks in the clinic or in a controlled remote setting.”
MethodDetecting Gait Events from Accelerations Using Reservoir Computing
Chiasson-Poirier, L., Younesian, H., Turcot, K., & Sylvestre, J. (2022) · Sensors · doi:10.3390/s22197180 · Cited by 9
“In addition, affordable IMU sensors and force-sensitive resistors (FSR) enable an easier large-scale gait data collection to apply ANN directly for GED [28].”
Method
Metadata
- Authors
- Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J.
- Affiliations
- Delft University of Technology (NL)
- École Polytechnique Fédérale de Lausanne (CH)
- Centre Hospitalier Universitaire Vaudois (CH)
- Erasmus MC (NL)
- ONWARD, EPFL Innovation Park Building C, 1015 Lausanne, Switzerland
- Corresponding author
- Vallery, Heike
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-04-13
- Volume
- 21
- Issue
- 8
- Pages
- 2727
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC8069962
- OpenAlex
- W3154710845
- Cited by
- 348
- References
- 140
- Citations by year
- 2026: 79 · 2025: 83 · 2024: 79 · 2023: 50 · 2022: 40 · 2021: 17
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (publishedVersion, cc-by)
- SERVAL (Université de Lausanne) (publishedVersion, cc-by)
- IRIS (submittedVersion, cc-by)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Research Repository (Delft University of Technology) (submittedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Funders
- Horizon 2020 Framework Programme (779963)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- wearable sensors, gait analysis, inertial measurement unit, insole pressure sensors, heel strike detection, toe-off detection, pathological gait, gait rehabilitation, neural prostheses, rule-based detection, sensor placement
- MeSH terms
- Wearable Electronic Devices, Gait Analysis, Activities of Daily Living, Biomechanical Phenomena, Gait, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.