Wearable Sensor-Based Real-Time Gait Detection: A Systematic Review
Open accessThe DOI matches its Crossref record; 140 of the 140 references it cites were found in a registry or an index.
Abstract
Gait analysis has traditionally been carried out in a laboratory environment using expensive equipment, but, recently, reliable, affordable, and wearable sensors have enabled integration into clinical applications as well as use during activities of daily living. Real-time gait analysis is key to the development of gait rehabilitation techniques and assistive devices such as neuroprostheses. This article presents a systematic review of wearable sensors and techniques used in real-time gait analysis, and their application to pathological gait. From four major scientific databases, we identified 1262 articles of which 113 were analyzed in full-text. We found that heel strike and toe off are the most sought-after gait events. Inertial measurement units (IMU) are the most widely used wearable sensors and the shank and foot are the preferred placements. Insole pressure sensors are the most common sensors for ground-truth validation for IMU-based gait detection. Rule-based techniques relying on threshold or peak detection are the most widely used gait detection method. The heterogeneity of evaluation criteria prevented quantitative performance comparison of all methods. Although most studies predicted that the proposed methods would work on pathological gait, less than one third were validated on such data. Clinical applications of gait detection algorithms were considered, and we recommend a combination of IMU and rule-based methods as an optimal solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


![Figure 1 Word cloud showing most frequently occurring keywords present in search results for a search query in Scopus (for instance, see Table 2), visualized by the software VOS-Viewer [35]. The size of each node indicates the relative relevance (based on the frequency of occurrence of keywords) of that topic among the list of articles returned by the search query. Connections between nodes were not used in refining the search terms.](https://figures.cochat.ai/paper-figures/8276573029d14706b8534ad4cde594cf/wearable-sensor-based-real-time-gait-detection-a-systematic-review-figure-1.jpg)





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The first is methodological heterogeneity in sensor placement, feature extraction, and analysis pipelines across studies, compounded by the absence of task-optimized sensor configurations (Prasanth et al., 2021; Niswander et al., 2020).”
From Multimodal neuroimaging and AI integration in cognitive disorders: advances, challenges, and future directions for precision medicine (2026) · cites this paper as Prasanth et al., 2021
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PRISMA-P Group, Moher, D., Shamseer, L., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., & Stewart, L. A. (2015) · Systematic Reviews · doi:10.1186/2046-4053-4-1 · Cited by 26,223 · cited 1×
“We therefore performed a systematic review and meta-analysis across the four major scientific databases mentioned earlier, following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) standard [21], covering 1262 articles, as will be discussed in the next sections.”
MethodSoftware survey: VOSviewer, a computer program for bibliometric mapping
van Eck, N. J., & Waltman, L. (2010) · Scientometrics · doi:10.1007/s11192-009-0146-3 · Cited by 21,484
Wavelets and signal processing
Rioul, O., & Vetterli, M. (1991) · IEEE Signal Processing Magazine · doi:10.1109/79.91217 · Cited by 2,786
The role of google scholar in evidence reviews and its applicability to grey literature searching
Haddaway, N. R., Collins, A. M., Coughlin, D., & Kirk, S. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138237 · Cited by 2,387 · cited 1×
“[28] classified scientific literature databases into two categories: Academic Citation Database (ACDB) and Academic Citation Search Engine (ACSE).”
BackgroundEstimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068
Nonlinear Complementary Filters on the Special Orthogonal Group
Mahony, R., Hamel, T., & Pflimlin, J.-M. (2008) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2008.923738 · Cited by 1,751
Targeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087 · cited 7×
“We categorized the target impairments into two classes based on how they were presented in the respective studies—first, generally diminished ambulatory function, where gait is impaired due to general degeneration of the locomotor system, such as with Parkinson’s disease, osteoarthritis, Huntington’s disease, diplegic…”
BackgroundInfluentialSelf-citationSpatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814 · cited 1×
“[80] reported that TO and HS events consist of combined features that can be well resolved in the time-frequency domain.”
BackgroundAssessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
VOS: A New Method for Visualizing Similarities between Objects
van Eck, N. J., & Waltman, L. (2006) · RePub (Erasmus University Rotterdam) · Cited by 633
A reliable gait phase detection system
Pappas, I. P. I., Popovic, M. R., Keller, T., Dietz, V., & Morari, M. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.928571 · Cited by 495 · cited 4×
“Furthermore, a direct quantitative comparison between [57] and [72] would be questionable since the data-set used by the former involved both unimpaired and impaired gait while the one used by the latter only involved unimpaired subjects walking on treadmill.”
BackgroundMethodInfluentialToward Pervasive Gait Analysis With Wearable Sensors: A Systematic Review
Chen, S., Lach, J., Lo, B., & Yang, G.-Z. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2016.2608720 · Cited by 443 · cited 2×
“[20] performed a systematic review focusing particularly on quantifiable gait measures and tangible evaluation techniques that are based on wearable sensors, particularly inertial measurement units (IMU).”
BackgroundA Human--Exoskeleton Interface Utilizing Electromyography
Fleischer, C., & Hommel, G. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.926860 · Cited by 412 · cited 2×
“Evaluation of EMG patterns are mostly done using classification algorithms and less often using physiological models [65].”
BackgroundMethodShull, P. B., Jirattigalachote, W., Hunt, M. A., Cutkosky, M. R., & Delp, S. L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.03.189 · Cited by 388 · cited 1×
“[22] Clinical impact of wearable sensing MEDLINE, Science Citation Index Expanded, CINAHL, Cochrane Not a systematic review, no review of gait detection methods 76”
BackgroundJasiewicz, J. M., Allum, J. H. J., Middleton, J. W., Barriskill, A., Condie, P., Purcell, B., & Li, R. C. T. (2006) · Gait & Posture · doi:10.1016/j.gaitpost.2005.12.017 · Cited by 371 · cited 1×
“[44] report that, upon comparison of three rule-based gait event detection methods, the method based on foot angular velocity and linear acceleration was significantly more accurate than that of the method based on the shank for spinal cord injured (SCI) subjects.”
MethodDynamic Hebbian learning in adaptive frequency oscillators
Righetti, L., Buchli, J., & Ijspeert, A. J. (2006) · Physica D: Nonlinear Phenomena · doi:10.1016/j.physd.2006.02.009 · Cited by 361 · cited 1×
“An adaptive oscillator (AO) is a frequency domain method that can synchronize to any periodic or pseudo-periodic input signal without any preprocessing [78].”
MethodSelf-citationGait Partitioning Methods: A Systematic Review
Taborri, J., Palermo, E., Rossi, S., & Cappa, P. (2016) · Sensors · doi:10.3390/s16010066 · Cited by 361
VOS: A New Method for Visualizing Similarities Between Objects
van Eck, N. J., & Waltman, L. (2007) · Studies in classification, data analysis, and knowledge organization · doi:10.1007/978-3-540-70981-7_34 · Cited by 361
Methods for gait event detection and analysis in ambulatory systems
Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.007 · Cited by 350 · cited 1×
“[26] Review of sensor configurations and placements, and a brief review of gait detection methods Not specified Not a systematic review, gait detection methods were reviewed very briefly -”
BackgroundA Comparison of Complementary and Kalman Filtering
Higgins, W. (1975) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/taes.1975.308081 · Cited by 299 · cited 1×
“Overall, Kalman filterbased methods are known to be more accurate but computationally demanding, while complementary filter-based methods are known to be computationally light and fairly accurate [52].”
MethodA systematic review of gait analysis methods based on inertial sensors and adaptive algorithms
Caldas, R., Mundt, M., Potthast, W., Buarque de Lima Neto, F., & Markert, B. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.06.019 · Cited by 297 · cited 2×
“[19] performed a systematic review across major databases such as Web of Science, ScienceDirect, IEEE, PubMed/MEDLINE, SCOPUS, CINAHL, and Cochrane, thereby ensuring an exhaustive coverage.”
BackgroundMethodThe expansion of Google Scholar versus Web of Science: a longitudinal study
de Winter, J. C. F., Zadpoor, A. A., & Dodou, D. (2014) · Scientometrics · doi:10.1007/s11192-013-1089-2 · Cited by 270
Smart Insole: A Wearable Sensor Device for Unobtrusive Gait Monitoring in Daily Life
Lin, F., Wang, A., Zhuang, Y., Tomita, M. R., & Xu, W. (2016) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2585643 · Cited by 265 · cited 2×
“[62] reported robustness against this offset, caused by the size mismatch of the IPS with the foot, by using the derivative of pressure signals.”
BackgroundMethodWearable Inertial Sensors for Human Motion Analysis: A Review
Lopez-Nava, I. H., & Munoz-Melendez, A. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2609392 · Cited by 263 · cited 1×
“López-Nava and Muñoz-Meléndez [23] Review on inertial sensors and sensor fusion methods for human motion analysis, ACM Digital Library, IEEE Xplore, PubMed, ScienceDirect, Scopus, Taylor Francis Online, Web of Science, Wiley Online Library Not a systematic review, no review of gait detection methods, review limited to…”
MethodA survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252 · cited 1×
“Novak and Riener [24] Sensor fusion methods in wearable robotics Not specified Not a systematic review, no review of gait detection methods -”
MethodOnline Detection of Freezing of Gait with Smartphones and Machine Learning Techniques
Mazilu, S., Hardegger, M., Zhu, Z., Roggen, D., Troester, G., Plotnik, M., & Hausdorff, J. (2012) · Proceedings of the 6th International Conference on Pervasive Computing Technologies for Healthcare · doi:10.4108/icst.pervasivehealth.2012.248680 · Cited by 231 · cited 1×
“[12], in the context of freezing of gait, reports 98% or more detection performance for all three body segments, suggesting that the question of optimal sensor placement is irrelevant in the context of freezing of gait.”
BackgroundBoeker, M., Vach, W., & Motschall, E. (2013) · BMC Medical Research Methodology · doi:10.1186/1471-2288-13-131 · Cited by 225
Evaluation of zero-velocity detectors for foot-mounted inertial navigation systems
Skog, I., Nilsson, J.-O., & Handel, P. (2010) · 2010 International Conference on Indoor Positioning and Indoor Navigation · doi:10.1109/ipin.2010.5646936 · Cited by 213 · cited 1×
“[54] compared four different detectors to identify the zero velocity interval—”acceleration moving variance detector, the acceleration magnitude detector, the angular rate energy (ARE) detector, and a generalized likelihood ratio test detector, referred to as the SHOE”—and concluded that both ARE and SHOE performed wi…”
BackgroundWenger, N., Moraud, E. M., Raspopovic, S., Bonizzato, M., DiGiovanna, J., Musienko, P., Morari, M., Micera, S., & Courtine, G. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008325 · Cited by 209 · cited 5×
“Similarly, with active neuroprostheses such as EES, the stimulation itself can substantially modify the gait pattern [16].”
BackgroundResultInfluentialBramer, W. M., Giustini, D., & Kramer, B. M. R. (2016) · Systematic Reviews · doi:10.1186/s13643-016-0215-7 · Cited by 202
Tober, M. (2011) · Medical Laser Application · doi:10.1016/j.mla.2011.05.006 · Cited by 189 · cited 1×
“However, this should not impact the comprehensiveness of our study since Science Direct and Scopus share the same database [29] and come from the same parent company (Elsevier).”
BackgroundPacini Panebianco, G., Bisi, M. C., Stagni, R., & Fantozzi, S. (2018) · Gait & Posture · doi:10.1016/j.gaitpost.2018.08.025 · Cited by 188
Real-time gait event detection using wearable sensors
Hanlon, M., & Anderson, R. (2009) · Gait & Posture · doi:10.1016/j.gaitpost.2009.07.128 · Cited by 187 · cited 1×
“[71] used a similar approach of setting a threshold on the derivative of the pressure sensor while additionally using a threshold on the accelerometer data along with its first and second derivative.”
MethodAnwary, A. R., Yu, H., & Vassallo, M. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2786587 · Cited by 175 · cited 1×
“[47] suggests that the optimal location for IMU placement on the foot is the medial arch followed by the Achilles tendon.”
BackgroundGait Event Detection on Level Ground and Incline Walking Using a Rate Gyroscope
Catalfamo, P., Ghoussayni, S., & Ewins, D. (2010) · Sensors · doi:10.3390/s100605683 · Cited by 159
A Soft Wearable Robotic Ankle-Foot-Orthosis for Post-Stroke Patients
Kwon, J., Park, J.-H., Ku, S., Jeong, Y., Paik, N.-J., & Park, Y.-L. (2019) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2019.2908491 · Cited by 158
Real-time gait event detection for paraplegic FES walking
Skelly, M. M., & Chizeck, H. J. (2001) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/7333.918277 · Cited by 157 · cited 3×
“A similar two-level approach using FIS with a supervisory function was also implemented by [13].”
BackgroundMethodKotiadis, D., Hermens, H. J., & Veltink, P. H. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.10.014 · Cited by 150
Towards Inertial Sensor Based Mobile Gait Analysis: Event-Detection and Spatio-Temporal Parameters
Teufl, W., Lorenz, M., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2018) · Sensors · doi:10.3390/s19010038 · Cited by 150
Comparison of Step Length Estimators from Weareable Accelerometer Devices
Álvarez, D., González, R. C., López, A. M., & Alvarez, J. C. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.259593 · Cited by 146
An oscillator-based smooth real-time estimate of gait phase for wearable robotics
Yan, T., Parri, A., Garate, V. R., Cempini, M., Ronsse, R., & Vitiello, N. (2016) · Autonomous Robots · doi:10.1007/s10514-016-9566-0 · Cited by 146 · cited 1×
“[79] used peak detection to identify a gait event, based on the occurrence of a desired bio-mechanical event (e.”
MethodTaborri, J., Rossi, S., Palermo, E., Patanè, F., & Cappa, P. (2014) · Sensors · doi:10.3390/s140916212 · Cited by 140
Ferrari, A., Ginis, P., Hardegger, M., Casamassima, F., Rocchi, L., & Chiari, L. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2457511 · Cited by 140 · cited 1×
“[48,55] used a threshold on the ARE to estimate the ZUPT interval by hypothesizing that the IMU is stationary when ARE is below the threshold.”
MethodA Real-Time Gait Event Detection for Lower Limb Prosthesis Control and Evaluation
Maqbool, H. F., Husman, M. A. B., Awad, M. I., Abouhossein, A., Iqbal, N., & Dehghani-Sanij, A. A. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2636367 · Cited by 138
STÖGGL, T. L., & Martiner, A. (2016) · Journal of Sports Sciences · doi:10.1080/02640414.2016.1161205 · Cited by 137 · cited 1×
“It is the only wearable sensor to be used in validation studies, which arguably makes it the gold standard in wearable sensing [61].”
MethodSeel, T., Werner, C., Raisch, J., & Schauer, T. (2016) · Control Engineering Practice · doi:10.1016/j.conengprac.2015.11.007 · Cited by 134
A wearable system for gait training in subjects with Parkinson's disease
Casamassima, F., Ferrari, A., Milosevic, B., Ginis, P., Farella, E., & Rocchi, L. (2014) · Sensors · doi:10.3390/s140406229 · Cited by 131 · cited 2×
“[48] compared these two methods based on accuracy, computational cost, and energy efficiency and concluded that the Kalman filter-based method was their preferred choice.”
MethodA Review of Gait Phase Detection Algorithms for Lower Limb Prostheses
Vu, H. T. T., Dong, D., Cao, H.-L., Verstraten, T., Lefeber, D., Vanderborght, B., & Geeroms, J. (2020) · Sensors · doi:10.3390/s20143972 · Cited by 130 · cited 1×
“[25] Gait event detection methods applicable specifically for prosthetic devices Scopus, ScienceDirect, Google Scholar Not a systematic review, review restricted to one category of rehabilitation devices 87”
MethodA Novel Adaptive, Real-Time Algorithm to Detect Gait Events From Wearable Sensors
Bejarano, N. C., Ambrosini, E., Pedrocchi, A., Ferrigno, G., Monticone, M., & Ferrante, S. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2337914 · Cited by 128
A Robust Parameterization of Human Gait Patterns Across Phase-Shifting Perturbations
Villarreal, D. J., Poonawala, H. A., & Gregg, R. D. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2569019 · Cited by 125 · cited 2×
“Although the method performed well in unimpaired subjects [76] and the offline analysis reported robustness to perturbations [77], it remains to be seen how the method would work with pathological gait in real-time.”
MethodIntelligent shoes for abnormal gait detection
Chen, M., Huang, B., & Xu, Y. (2008) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2008.4543503 · Cited by 122
Online Phase Detection Using Wearable Sensors for Walking with a Robotic Prosthesis
Goršič, M., Kamnik, R., Ambrožič, L., Vitiello, N., Lefeber, D., Pasquini, G., & Munih, M. (2014) · Sensors · doi:10.3390/s140202776 · Cited by 121
Quasi real-time gait event detection using shank-attached gyroscopes
Lee, J. K., & Park, E. J. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0736-0 · Cited by 120
Online Decoding of Hidden Markov Models for Gait Event Detection Using Foot-Mounted Gyroscopes
Mannini, A., Genovese, V., & Sabatin, A. M. (2014) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2293887 · Cited by 114
Gouwanda, D., & Gopalai, A. A. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.12.004 · Cited by 109
Gait and activity recognition using commercial phones
Derawi, M. O., & Bours, P. (2013) · Computers & Security · doi:10.1016/j.cose.2013.07.004 · Cited by 109
Chang, H.-C., Hsu, Y., Yang, S.-C., Lin, J.-C., & Wu, Z.-H. (2016) · IEEE Access · doi:10.1109/access.2016.2633304 · Cited by 109
An Ambulatory System for Gait Monitoring Based on Wireless Sensorized Insoles
Gónzalez, I., Fontecha, J., Hervás, R., & Bravo, J. (2015) · Sensors · doi:10.3390/s150716589 · Cited by 103 · cited 1×
“[73] fuzzified the input from pressure sensors placed at the heel, the hallux, and the first and fifth metatarsals into fuzzy variables and defined a rule base whose outputs are gait phases.”
BackgroundGait Detection in Children with and without Hemiplegia Using Single-Axis Wearable Gyroscopes
Abaid, N., Cappa, P., Palermo, E., Petrarca, M., & Porfiri, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0073152 · Cited by 89 · cited 1×
“[3] used angular velocity of the foot in the sagittal plane as input to the HMM, while Ref.”
MethodSimultaneous Bayesian Recognition of Locomotion and Gait Phases With Wearable Sensors
Martínez-Hernández, U., Mahmood, I., & Dehghani-Sanij, A. A. (2017) · IEEE Sensors Journal · doi:10.1109/jsen.2017.2782181 · Cited by 88
ED-FNN: A New Deep Learning Algorithm to Detect Percentage of the Gait Cycle for Powered Prostheses
Vu, H. T. T., Gomez, F., Cherelle, P., Lefeber, D., Nowé, A., & Vanderborght, B. (2018) · Sensors · doi:10.3390/s18072389 · Cited by 86
Lauer, R. T., Smith, B. T., & Betz, R. R. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851527 · Cited by 85 · cited 2×
“One disadvantage of FIS is that it requires the state membership functions to be set by the user [74] and then be adapted each time to a new subject or data set for optimal performance, similarly to what is done with thresholds as discussed in Section 3.”
MethodTaborri, J., Scalona, E., Palermo, E., Rossi, S., & Cappa, P. (2015) · Sensors · doi:10.3390/s150924514 · Cited by 84
Computational Intelligent Gait-Phase Detection System to Identify Pathological Gait
Senanayake, C., & Senanayake, S. M. N. A. (2010) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2058813 · Cited by 83 · cited 3×
“IPSs are typically placed inside the shoe and are thus subject to pressure between it and the foot, which can lead to non-zero pressure readings even when the foot is in swing phase [42,59].”
BackgroundMethodGait event detection for use in FES rehabilitation by radial and tangential foot accelerations
Rüterbories, J., Spaich, E. G., & Andersen, O. K. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.10.004 · Cited by 81 · cited 2×
“More specifically, real-time gait analysis has proven essential in applications necessitating real-time control such as exoskeletons and prostheses, as well as gait rehabilitation involving Functional Electrical Stimulation (FES) [13,14] or Epidural Electrical Stimulation (EES) [15].”
BackgroundAllseits, E., Lučarević, J., GAILEY, R. S., Agrawal, V., GAUNAURD, I. A., & Bennett, C. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.02.016 · Cited by 80
Real-Time continuous gait phase and speed estimation from a single sensor
Quintero, D., Lambert, D. J., Villarreal, D. J., & Gregg, R. D. (2017) · IEEE Conference on Control Technology and Applications (CCTA) · doi:10.1109/ccta.2017.8062565 · Cited by 80 · cited 2×
“Although the method performed well in unimpaired subjects [76] and the offline analysis reported robustness to perturbations [77], it remains to be seen how the method would work with pathological gait in real-time.”
BackgroundMethodTeufl, W., Taetz, B., Miezal, M., Lorenz, M., Pietschmann, J., Jöllenbeck, T., Fröhlich, M., & Bleser, G. (2019) · Sensors · doi:10.3390/s19225006 · Cited by 77
A powered prosthetic ankle joint for walking and running
Grimmer, M., Holgate, M. A., Holgate, R., Boehler, A., Ward, J. A., Hollander, K. W., Sugar, T. G., & Andre Seyfarth, A. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0286-7 · Cited by 74
Automated Accelerometer-Based Gait Event Detection During Multiple Running Conditions
Benson, L. C., Clermont, C. A., Watari, R., Exley, T., & Ferber, R. (2019) · Sensors · doi:10.3390/s19071483 · Cited by 69
Gong, C., Qi, P., Guo, Z., & Yu, H. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2604340 · Cited by 67 · cited 2×
“its primary uses has been in diagnosing walking impairment in people with gait disabilities [1–4] and inspires control mechanisms of exoskeletons [5,6] and prostheses [7], among other applications [8–12].”
BackgroundEstimation of Step Length and Gait Asymmetry Using Wearable Inertial Sensors
Wang, L., Sun, Y. T., Li, Q., & Liu, T. (2018) · IEEE Sensors Journal · doi:10.1109/jsen.2018.2815700 · Cited by 65
Zhou, H. D., Ji, N., Samuel, O. W., Cao, Y., Zhao, Z., Chen, S., & Li, G. (2016) · Sensors · doi:10.3390/s16101634 · Cited by 64
Real-Time Identification of Gait Events in Impaired Subjects Using a Single-IMU Foot-Mounted Device
Perez-Ibarra, J. C., Siqueira, A. A. G., & Krebs, H. I. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2951923 · Cited by 61 · cited 2×
“[27] that not many real-time gait detection algorithms are validated on populations with gait impairments.”
BackgroundMethodReal-Time Gait Analysis Using a Single Head-Worn Inertial Measurement Unit
Hwang, T., Reh, J., Effenberg, A. O., & Blume, H. (2018) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2018.2843289 · Cited by 59
Development of gait segmentation methods for wearable foot pressure sensors
Crea, S., Rossi, S., Donati, M., Reberšek, P., Novak, D., Vitiello, N., Lenzi, T., Podobnik, J., Munih, M., & Carrozza, M. C. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6347120 · Cited by 55 · cited 1×
“The authors of [63,64] followed a similar approach using a pressure signal from the IPS and its first derivative while using an IPS with 64 optoelectronic sensors.”
MethodGait Event Detection in Controlled and Real-Life Situations: Repeated Measures From Healthy Subjects
Figueiredo, J., Felix, P., Costa, L., Moreno, J. C., & Santos, C. P. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2868094 · Cited by 55
3D Human Gait Reconstruction and Monitoring Using Body-Worn Inertial Sensors and Kinematic Modeling
Ahmadi, A., Destelle, F., Unzueta, L., Monaghan, D. S., Linaza, M. T., Moran, K., & O'Connor, N. E. (2016) · IEEE Sensors Journal · doi:10.1109/jsen.2016.2593011 · Cited by 54
Real-Time Detection of Seven Phases of Gait in Children with Cerebral Palsy Using Two Gyroscopes
Behboodi, A., Zahradka, N., Wright, H., Alesi, J. F., & Lee, S. C. K. (2019) · Sensors · doi:10.3390/s19112517 · Cited by 53
Farmer, S., Silver-Thorn, B., Voglewede, P. A., & Beardsley, S. A. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056027 · Cited by 44 · cited 1×
“[66] presented an auto-correlation model that takes EMG signals as input to predict the ankle angle, which is claimed to predict around 100 ms in advance.”
MethodReal-Time Gait Event Detection Based on Kinematic Data Coupled to a Biomechanical Model †
Lambrecht, S., Harutyunyan, A., Tanghe, K., Afschrift, M., Schutter, J. D., & Jonkers, I. (2017) · Sensors · doi:10.3390/s17040671 · Cited by 42
Real-time gait event detection for lower limb amputees using a single wearable sensor
Maqbool, H. F., Husman, M. A. B., Awad, M. I., Abouhossein, A., Mehryar, P., Iqbal, N., & Dehghani-Sanij, A. A. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591866 · Cited by 40
Aich, S., Pradhan, P. M., Chakraborty, S., Kim, H., Kim, H.-T., Lee, H.-G., Kim, I. H., Joo, M.-I., Seong, S. J., & Park, J. (2020) · Journal of Healthcare Engineering · doi:10.1155/2020/1823268 · Cited by 40
Controlling a Robotic Hip Exoskeleton With Noncontact Capacitive Sensors
Crea, S., Manca, S., Parri, A., Zheng, E., Mai, J., Lova, R. M., Vitiello, N., & Wang, Q. (2019) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2019.2929826 · Cited by 39
Kinematic Analysis of Human Gait Based on Wearable Sensor System for Gait Rehabilitation
Chen, W., Xu, Y., Wang, J., & Zhang, J. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0179-z · Cited by 38 · cited 1×
“[75] used inputs from both IPSs and accelerometers and used a third order fast Fourier transform followed by a principal component analysis for feature generation which was then fed to a support vector machine classifier to identify the gait phases.”
MethodReal-Time Human Foot Motion Localization Algorithm With Dynamic Speed
Nguyen, L. V., & La, H. M. (2016) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2016.2586741 · Cited by 36 · cited 2×
“[58] proposed an adaptive thresholdbased method which automatically computes and updates the threshold in real-time.”
BackgroundMethodFagan, J. C. (2017) · Information Technology and Libraries · doi:10.6017/ital.v36i2.9718 · Cited by 36
Monitoring Insole (MONI): A Low Power Solution Toward Daily Gait Monitoring and Analysis
Hua, R., & Wang, Y. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2910105 · Cited by 36
A Novel CPS System for Evaluating a Neural-Machine Interface for Artificial Legs
Zhang, F., DiSanto, W., Jin, R., Dou, Z., Yang, Q., & Huang, H. (2011) · ACM/IEEE International Conference on Cyber-Physical Systems (ICCPS) · doi:10.1109/iccps.2011.13 · Cited by 35
Mannini, A., Trojaniello, D., Croce, U. D., & Sabatini, A. M. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319558 · Cited by 35 · cited 1×
“The authors of [63,64] followed a similar approach using a pressure signal from the IPS and its first derivative while using an IPS with 64 optoelectronic sensors.”
MethodAutomatic virtual impedance adaptation of a knee exoskeleton for personalized walking assistance
Chinimilli, P. T., Qiao, Z., Sorkhabadi, S. M. R., Jhawar, V., Fong, I. H., & Zhang, W. (2019) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2019.01.013 · Cited by 35
Towards real-time profiling of sprints using wearable pressure sensors
Harle, R. K., Taherian, S., Pias, M. R., Coulouris, G., Hopper, A., Cameron, J., Lasenby, J., Kuntze, G., BEZODIS, I. N., Irwin, G., et al. (2011) · Computer Communications · doi:10.1016/j.comcom.2011.03.019 · Cited by 34
Meng, L., Martínez-Hernández, U., Childs, C. R., Dehghani-Sanij, A. A., & Buis, A. W. P. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2938764 · Cited by 34
Health sensing by wearable sensors and mobile phones: A survey
Song, L., Wang, Y., Yang, J., & Li, J. (2014) · IEEE International Conference on e-Health Networking, Applications and Services (Healthcom) · doi:10.1109/healthcom.2014.7001885 · Cited by 33 · cited 1×
“[8] Health sensing techniques with a particular focus on smartphone sensing Not specified Not a systematic review, no review of gait detection methods -”
BackgroundSeven phases of gait detected in real-time using shank attached gyroscopes
Behboodi, A., Wright, H., Zahradka, N., & Lee, S. C. K. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319644 · Cited by 33 · cited 1×
“Gyroscopes are invariant to translation in position [39] since the angular velocity of a rigid body is the same at any point along the body (assuming the orientation of the sensor remains the same with respect to the body segment).”
BackgroundMachine Learning Based Adaptive Gait Phase Estimation Using Inertial Measurement Sensors
Yang, J., Huang, T.-H., Yu, S., Yang, X., Su, H., Spungen, A. M., & Tsai, C. (2019) · Design of Medical Devices Conference (DMD) · doi:10.1115/dmd2019-3266 · Cited by 33
Real-time gait analysis with accelerometer-based smart shoes
Delgado-Gonzalo, R., Hubbard, J., Renevey, P., Lemkaddem, A., Vellinga, Q., Ashby, D., Willardson, J., & Bertschi, M. (2017) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2017.8036783 · Cited by 30 · cited 1×
“[60] report that IPSs have a short lifespan, although the claim is not adequately validated.”
BackgroundReal-time biofeedback device for gait rehabilitation of post-stroke patients
Khoo, I., Marayong, P., Krishnan, V., Balagtas, M. N., Rojas, O., & Leyba, K. A. (2017) · Biomedical Engineering Letters · doi:10.1007/s13534-017-0036-1 · Cited by 27
Real-time gait event detection for transfemoral amputees during ramp ascending and descending
Maqbool, H. F., Husman, M. A., Awad, M. I., Abouhossein, A., & Dehghani-Sanij, A. A. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319464 · Cited by 22
Schneider, O., MacLean, K. E., Altun, K., Karuei, I., & Wu, M. (2013) · ACM International Conference on Intelligent User Interfaces (IUI) · doi:10.1145/2449396.2449418 · Cited by 21
Freezing of Gait (FoG) detection for Parkinson Disease
Tay, A. E., Yen, S., Lee, P. Y., Wang, C. Y., Neo, A., Phan, S. W., Yogaprakash, K., Liew, S. G., & Au, W. (2015) · Asian Control Conference (ASCC) · doi:10.1109/ascc.2015.7244608 · Cited by 20
Smart wearable device for real time gait event detection during running
Alahakone, A. U., Senanayake, S. M. N. A., & Senanayake, C. (2010) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas.2010.5774975 · Cited by 20
Regression Models for Estimating Kinematic Gait Parameters with Instrumented Footwear
Zhang, H., Tay, M. O., Suar, Z. M., Kurt, M., & Zanotto, D. (2018) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2018.8487972 · Cited by 20
Classification and Kinetic Analysis of Healthy Gait using Multiple Accelerometer Sensors
Nutakki, C. S., Mathew, R. J., Suresh, A., Vijay, A. R., Krishna, S., Babu, A. S., & Diwakar, S. (2020) · Procedia Computer Science · doi:10.1016/j.procs.2020.04.041 · Cited by 19
Smartphone based gait analysis using STFT and wavelet transform for indoor navigation
Han, D., Renaudin, V., & Ortiz, M. (2014) · International Conference on Indoor Positioning and Indoor Navigation · doi:10.1109/ipin.2014.7275480 · Cited by 16
Gait quantification and visualization for digital healthcare
Anwary, A. R., Yu, H., & Vassallo, M. (2019) · Health Policy and Technology · doi:10.1016/j.hlpt.2019.12.004 · Cited by 16
Online Gait Detection with an Automatic Mobile Trainer Inspired by Neuro-Developmental Treatment
Wang, F., Li, Y.-C., Wu, K., Chen, P.-Y., & Fu, L. (2020) · Sensors · doi:10.3390/s20123389 · Cited by 16
Luo, J., Tang, J., & Xiao, X. (2016) · Journal of Sensors · doi:10.1155/2016/5869238 · Cited by 15
Real-time gait event recognition for wearable assistive device using an IMU on thigh
Piriyakulkit, S., Hirata, Y., & Ozawa, H. (2017) · IEEE International Conference on Cyborg and Bionic Systems (CBS) · doi:10.1109/cbs.2017.8266123 · Cited by 15
Localization system for pedestrians based on sensor and information fusion
Anacleto, R., Figueiredo, L., Almeida, A. M. L., & Nováis, P. (2014) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 13
A novel gait phase-based control strategy for a portable knee-ankle-foot robot
Gong, C., Salim, V., & Yu, H. (2015) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2015.7281261 · Cited by 13
Development of an augmented feedback system for training of gait improvement using vibrotactile cues
Afzal, M. R., Lee, H., Yoon, J., Oh, M.-K., & Lee, C.-H. (2017) · International Conference on Ubiquitous Robots and Ambient Intelligence · doi:10.1109/urai.2017.7992833 · Cited by 13
Li, F., Liu, G., Liu, J., Chen, X., & Ma, X. (2016) · Sensors · doi:10.3390/s16111809 · Cited by 12 · cited 1×
“[43] compares IMU signals from the thigh, the”
BackgroundLi, H., Derrode, S., & Wojciech Pieczynski, E. (2019) · Sensors · doi:10.3390/s19194242 · Cited by 12
Pitale, J. T., & Bolte, J. H. (2018) · Pilot and Feasibility Studies · doi:10.1186/s40814-018-0229-0 · Cited by 12
Online Learning of Gait Models From Older Adult Data
Waugh, J. L. S., Huang, E., Fraser, J., Beyer, K. B., Trinh, A., McIlroy, W. E., & Kulić, D. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2904477 · Cited by 11
Implementation of Omnidirectional Lower Limbs Rehabilitation Training Robot
Yang, J., Chen, X., Guo, H., & Zhang, Q. (2007) · International Conference on Electrical Machines and Systems (ICEMS) · doi:10.1109/icems12746.2007.4412267 · Cited by 10
Bio-Inspired Real-Time Prediction of Human Locomotion for Exoskeletal Robot Control
Duan, P., Li, S., Duan, Z., & Chen, Y. (2017) · Applied Sciences · doi:10.3390/app7111130 · Cited by 10
A Novel Control Method of A Soft Exosuit with Plantar Pressure Sensors
Hu, H., Fang, K., Guan, H., Wu, X., & Chen, C. (2019) · International Conference on Advanced Robotics and Mechatronics (ICARM) · doi:10.1109/icarm.2019.8833934 · Cited by 10
AN FES-ASSISTED GAIT TRAINING SYSTEM FOR HEMIPLEGIC STROKE PATIENTS BASED ON INERTIAL SENSORS
Negård, N.-O., Schauer, T., Kauert, R., & Raisch, J. (2006) · IFAC Proceedings Volumes · doi:10.3182/20060920-3-fr-2912.00058 · Cited by 9
Real-time motion artifact detection and removal for ambulatory BCI
Kim, B. H., & Jo, S. (2015) · doi:10.1109/iww-bci.2015.7073050 · Cited by 9
ADAPTIVE REAL-TIME TOOL FOR HUMAN GAIT EVENT DETECTION USING A WEARABLE GYROSCOPE
FÉLIX, P., Figueiredo, J., Santos, C. P., & Moreno, J. C. (2017) · doi:10.1142/9789813231047_0079 · Cited by 9
Real-Time Tool for Human Gait Detection from Lower Trunk Acceleration
Gonçalves, H. R., Moreira, R., Rodrigues, M., Minas, G. M. H., Reis, L. P., & Santos, C. P. (2018) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-77700-9_2 · Cited by 9
A Comparison of Multisensor Attitude Estimation Algorithms
Cirillo, A., Cirillo, P., Maria, G. D., Natale, C., & Pirozzi, S. (2016) · doi:10.1201/9781315368795-32 · Cited by 9
Cai, V. A. D., Ibanez, A., Granata, C., Nguyen, V. T., & Nguyen, M. T. (2016) · Meccanica · doi:10.1007/s11012-016-0575-z · Cited by 8
Instrumented insole system for ambulatory and robotic walking assistance: First advances
Figueiredo, J., Ferreira, C., Costa, L., Sepúlveda, J., Reis, L. P., Moreno, J. C., & Santos, C. P. (2017) · IEEE International Conference on Autonomous Robot Systems and Competitions · doi:10.1109/icarsc.2017.7964062 · Cited by 8
Ji, Q., Yang, L., Li, W., Zhou, C., & Ye, X. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aae7ee · Cited by 8
An Adaptive Real-Time Algorithm to Detect Gait Events Using Inertial Sensors
Bejarano, N. C., Ambrosini, E., Pedrocchi, A., Ferrigno, G., Monticone, M., & Ferrante, S. (2013) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-319-00846-2_444 · Cited by 7 · cited 1×
“[46] analyzed four signals—linear acceleration in forward and vertical direction, angular velocity, and segment angle normal to the sagittal plane—for the thigh, the shank, and the foot.”
BackgroundWireless gait event detection system based on single gyroscope
Kang, D. W., Choi, J. S., Kim, H. S., Oh, H. S., Seo, J. W., Lee, J., & Tack, G. (2012) · International Conference on Ubiquitous Information Management and Communication (IMCOM) · doi:10.1145/2184751.2184855 · Cited by 7
Indoor Localization with Particle Filter in Multiple Motion Patterns
Li, Q., Liao, X., & Gao, Z. (2020) · IEEE Wireless Communications and Networking Conference · doi:10.1109/wcnc45663.2020.9120637 · Cited by 6
Aguirre-Ollinger, G., Narayan, A., Reyes, F. A., Cheng, H.-J., & Yu, H. (2018) · Biosystems & biorobotics · doi:10.1007/978-3-030-01845-0_85 · Cited by 4
Intention Detection and Gait Recognition (IDGR) System for Gait Assessment: A Pilot Study
Singh, Y., Kher, M., & Vashista, V. (2019) · IEEE International Conference on Robot and Human Interactive Communication (RO-MAN) · doi:10.1109/ro-man46459.2019.8956299 · Cited by 4
Real-time gait phase detection using wearable sensors
Mazhar, O., Bari, A. Z., & Faudzi, A. A. M. (2015) · Asian Control Conference (ASCC) · doi:10.1109/ascc.2015.7244853 · Cited by 3
INERTIAL GAIT PHASE DETECTION: POLYNOMIAL NULLSPACE APPROACH
Šprdlík, O., & Hurák, Z. (2006) · IFAC Proceedings Volumes · doi:10.3182/20060920-3-fr-2912.00068 · Cited by 3
Stance Sub-phases Gait Event Detection in Real-Time for Ramp Ascent and Descent
Maqbool, H. F., Husman, M. A., Awad, M. I., Abouhossein, A., Iqbal, N., & Dehghani-Sanij, A. A. (2016) · Biosystems & biorobotics · doi:10.1007/978-3-319-46669-9_34 · Cited by 3 · cited 1×
“[37] additionally used accelerometer signals.”
Efficient Transfer of Human Motion Data over a Wireless Delay Tolerant Network
Klingbeil, L., Wark, T., & Bidargaddi, N. P. (2007) · International Conference on Intelligent Sensors, Sensor Networks and Information Processing · doi:10.1109/issnip.2007.4496908 · Cited by 3
An error-based micro-sensor capture system for real-time motion estimation
Yang, L., Ye, S., Wang, Z., Huang, Z., Wu, J., Kong, Y., & Zhang, L. (2017) · Journal of Semiconductors · doi:10.1088/1674-4926/38/10/105004 · Cited by 3 · cited 1×
“[53] estimated the stance duration from thresholds set on both angular velocity and acceleration, which helped in correctly applying the ZUPT.”
MethodWearable sensors for realtime accurate hip angle estimation
Zhang, Z., Wu, J., & Huang, Z. (2008) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/icsmc.2008.4811743 · Cited by 2
A REAL-TIME GAIT PHASE DETECTION METHOD FOR PROSTHESIS CONTROL
Li, J., Zhou, X., Li, C., Li, W., Zhang, H., & GU, H. (2015) · doi:10.1142/9789814725248_0070 · Cited by 2
Erratum to: Stance Sub-phases Gait Event Detection in Real-Time for Ramp Ascent and Descent
Maqbool, H. F., Husman, M. A., Awad, M. I., Abouhossein, A., Iqbal, N., & Dehghani-Sanij, A. A. (2017) · Biosystems & biorobotics · doi:10.1007/978-3-319-46669-9_247 · Cited by 1
Research works printed but not linked: 1
- Lee, 1994, Wavelet analysis: Theory and applications, Hewlett Packard J., 45, 44
Cited by
Wearable sensors for activity monitoring and motion control: A review
Wang, X., Yu, H., Kold, S., Rahbek, O., & Bai, S. (2023) · Biomimetic Intelligence and Robotics · doi:10.1016/j.birob.2023.100089 · Cited by 213
de Miguel-Fernández, J., Lobo-Prat, J., Prinsen, E. C., Font-Llagunes, J. M., & Marchal–Crespo, L. (2023) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-023-01144-5 · Cited by 164
A Survey of Human Gait-Based Artificial Intelligence Applications
Harris, E., Khoo, I., & Demircan, E. (2022) · Frontiers in Robotics and AI · doi:10.3389/frobt.2021.749274 · Cited by 165
“, 2018), gait event detection and gait phase recognition (Prasanth et al., 2021), clinical gait diagnostics of knee osteoarthritis (Parisi et al.”
BackgroundSensor-Based Wearable Systems for Monitoring Human Motion and Posture: A Review
Huang, X., Xue, Y., Ren, S., & Wang, F. (2023) · Sensors · doi:10.3390/s23229047 · Cited by 166
Huang, T.-H., Zhang, S., Yu, S., MacLean, M. K., Zhu, J., Lallo, A. D., Jiao, C., Bulea, T. C., Zheng, M., & Su, H. (2022) · IEEE Transactions on Robotics · doi:10.1109/tro.2022.3170287 · Cited by 95
“Traditional high-level exoskeleton controllers cannot accurately produce biological joint moment patterns and adapt to changes in walking patterns [20], [31].”
Background
Metadata
- Authors
- Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J.
- Affiliations
- Delft University of Technology (NL)
- École Polytechnique Fédérale de Lausanne (CH)
- Centre Hospitalier Universitaire Vaudois (CH)
- Erasmus MC (NL)
- ONWARD, EPFL Innovation Park Building C, 1015 Lausanne, Switzerland
- Corresponding author
- Vallery, Heike
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-04-13
- Volume
- 21
- Issue
- 8
- Pages
- 2727
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC8069962
- OpenAlex
- W3154710845
- Cited by
- 348
- References
- 140
- Citations by year
- 2026: 79 · 2025: 83 · 2024: 79 · 2023: 50 · 2022: 40 · 2021: 17
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (publishedVersion, cc-by)
- SERVAL (Université de Lausanne) (publishedVersion, cc-by)
- IRIS (submittedVersion, cc-by)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Research Repository (Delft University of Technology) (submittedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Funders
- Horizon 2020 Framework Programme (779963)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- wearable sensors, gait analysis, inertial measurement unit, insole pressure sensors, heel strike detection, toe-off detection, pathological gait, gait rehabilitation, neural prostheses, rule-based detection, sensor placement
- MeSH terms
- Wearable Electronic Devices, Gait Analysis, Activities of Daily Living, Biomechanical Phenomena, Gait, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.