The DOI matches its Crossref record; 140 of the 140 references it cites were found in a registry or an index.
Wearable Sensor-Based Real-Time Gait Detection: A Systematic Review
Open accessAbstract
Gait analysis has traditionally been carried out in a laboratory environment using expensive equipment, but, recently, reliable, affordable, and wearable sensors have enabled integration into clinical applications as well as use during activities of daily living. Real-time gait analysis is key to the development of gait rehabilitation techniques and assistive devices such as neuroprostheses. This article presents a systematic review of wearable sensors and techniques used in real-time gait analysis, and their application to pathological gait. From four major scientific databases, we identified 1262 articles of which 113 were analyzed in full-text. We found that heel strike and toe off are the most sought-after gait events. Inertial measurement units (IMU) are the most widely used wearable sensors and the shank and foot are the preferred placements. Insole pressure sensors are the most common sensors for ground-truth validation for IMU-based gait detection. Rule-based techniques relying on threshold or peak detection are the most widely used gait detection method. The heterogeneity of evaluation criteria prevented quantitative performance comparison of all methods. Although most studies predicted that the proposed methods would work on pathological gait, less than one third were validated on such data. Clinical applications of gait detection algorithms were considered, and we recommend a combination of IMU and rule-based methods as an optimal solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


![Figure 1 Word cloud showing most frequently occurring keywords present in search results for a search query in Scopus (for instance, see Table 2), visualized by the software VOS-Viewer [35]. The size of each node indicates the relative relevance (based on the frequency of occurrence of keywords) of that topic among the list of articles returned by the search query. Connections between nodes were not used in refining the search terms.](https://figures.cochat.ai/paper-figures/8276573029d14706b8534ad4cde594cf/wearable-sensor-based-real-time-gait-detection-a-systematic-review-figure-1.jpg)





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The first is methodological heterogeneity in sensor placement, feature extraction, and analysis pipelines across studies, compounded by the absence of task-optimized sensor configurations (Prasanth et al., 2021; Niswander et al., 2020).”
From Multimodal neuroimaging and AI integration in cognitive disorders: advances, challenges, and future directions for precision medicine (2026) · cites this paper as Prasanth et al., 2021
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PRISMA-P Group, Moher, D., Shamseer, L., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., & Stewart, L. A. (2015) · Systematic Reviews · doi:10.1186/2046-4053-4-1 · Cited by 26,223 · cited 1×
“We therefore performed a systematic review and meta-analysis across the four major scientific databases mentioned earlier, following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) standard [21], covering 1262 articles, as will be discussed in the next sections.”
MethodSoftware survey: VOSviewer, a computer program for bibliometric mapping
van Eck, N. J., & Waltman, L. (2010) · Scientometrics · doi:10.1007/s11192-009-0146-3 · Cited by 21,484
Wavelets and signal processing
Rioul, O., & Vetterli, M. (1991) · IEEE Signal Processing Magazine · doi:10.1109/79.91217 · Cited by 2,786
The role of google scholar in evidence reviews and its applicability to grey literature searching
Haddaway, N. R., Collins, A. M., Coughlin, D., & Kirk, S. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138237 · Cited by 2,387 · cited 1×
“[28] classified scientific literature databases into two categories: Academic Citation Database (ACDB) and Academic Citation Search Engine (ACSE).”
BackgroundEstimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068
Nonlinear Complementary Filters on the Special Orthogonal Group
Mahony, R., Hamel, T., & Pflimlin, J.-M. (2008) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2008.923738 · Cited by 1,751
Targeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087 · cited 7×
“We categorized the target impairments into two classes based on how they were presented in the respective studies—first, generally diminished ambulatory function, where gait is impaired due to general degeneration of the locomotor system, such as with Parkinson’s disease, osteoarthritis, Huntington’s disease, diplegic…”
BackgroundInfluentialSelf-citationSpatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814 · cited 1×
“[80] reported that TO and HS events consist of combined features that can be well resolved in the time-frequency domain.”
BackgroundAssessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
VOS: A New Method for Visualizing Similarities between Objects
van Eck, N. J., & Waltman, L. (2006) · RePub (Erasmus University Rotterdam) · Cited by 633
Research works printed but not linked: 1
- Lee, 1994, Wavelet analysis: Theory and applications, Hewlett Packard J., 45, 44
Cited by
Items 101–200 of 348
Inertial Measurement of Head Tilt in Rodents: Principles and Applications to Vestibular Research
Fayat, R., Betancourt, V. D., Goyallon, T., Petremann, M., Liaudet, P., Descossy, V., Revéret, L., & Dugué, G. P. (2021) · Sensors · doi:10.3390/s21186318 · Cited by 9
de Miguel-Fernández, J., Lobo-Prat, J., Prinsen, E. C., Font-Llagunes, J. M., & Marchal–Crespo, L. (2022) · Research Square · doi:10.21203/rs.3.rs-1195778/v1 · Cited by 10
Gait Pattern Identification Using Gait Features
Kim, M., Han, J.-H., Shin, W.-C., & Hong, Y.-S. (2024) · Electronics · doi:10.3390/electronics13101956 · Cited by 8
Ettema, S., Pennink, G. H., Buurke, T. J. W., David, S., van Bennekom, C. A. M., & Houdijk, H. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01389-8 · Cited by 8
“Rehabilitation technology is widely used to assess gait quality and behavior [3], and to improve gait function through the use of supportive training devices [1].”
BackgroundMethodShin, J., Kweon, H.-J., & Choi, J. (2024) · JMIR Formative Research · doi:10.2196/63928 · Cited by 9
Gait Event Detection and Gait Parameter Estimation from a Single Waist-Worn IMU Sensor
Stenger, R., Pour, H. H., Teich, J., Hein, A., & Fudickar, S. (2025) · Sensors · doi:10.3390/s25206463 · Cited by 11
“Rule-based techniques, typically relying on thresholds or peak detection, are still widely used for gait event detection, particularly for HS and TO [14].”
InfluentialLatsch, B., Herbst, F., Suppelt, M., Seiler, J., Schaumann, S., Suppelt, S., Altmann, A. A., Grimmer, M., & Kupnik, M. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3638124 · Cited by 13
“Prasanth et al. [44] present wearable sensors capable of real-time gait analysis, while Subramaniam et al. [45] provide an overview of insole systems that also extend to heart-rate and general health monitoring.”
Performance Index for in Home Assessment of Motion Abilities in Ataxia Telangiectasia: A Pilot Study
Arayshi, M. E., Verrelli, C. M., Saggio, G., Iosa, M., Gentile, A. E., Chessa, L., Ruggieri, M., & Polizzi, A. (2022) · Applied Sciences · doi:10.3390/app12084093 · Cited by 8
Bergamo, G., Swaminathan, K., Kim, D., Chin, A., Siviy, C., Novillo, I., Baker, T. C., Wendel, N. C., Ellis, T. D., & Walsh, C. J. (2023) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr58425.2023.10304695 · Cited by 9
“Nonlinear machine learning approaches have been shown to be effective in other areas of biomechanics and force estimation [19]–[21], and thus there is an opportunity to investigate their integration for 3D GRF estimation.”
BackgroundEvaluation of Smartphone Technology on Spatiotemporal Gait in Older and Diseased Adult Populations
Contreras, C., Stanley, E. C., Deschamps-Prescott, C., Burnap, S., Hopkins, M., Browning, B., & Christensen, J. C. (2024) · Sensors · doi:10.3390/s24175839 · Cited by 9
“However, these methods can be relatively expensive, unreliable and require a skilled operator for data interpretation [12,13].”
BackgroundMacLean, M. K., Rehman, R. Z. U., Kerse, N. M., Taylor, L. M., Rochester, L., & Din, S. D. (2023) · Sensors · doi:10.3390/s23218973 · Cited by 9
“Many gait identification algorithms have been developed for wearable sensors such as accelerometers and inertial measurement units (IMU) to isolate walking bouts in the real-world [15,19,20].”
BackgroundDang, M., Liu, B., Chen, Y., & Zhang, Z. (2026) · Psychoradiology · doi:10.1093/psyrad/kkag007 · Cited by 10
Siew, S. K. H., Yu, J., Teo, T. L., Chua, K. C., Mahendran, R., & Rawtaer, I. (2024) · PLoS ONE · doi:10.1371/journal.pone.0293340 · Cited by 9
Continuous Gait Phase Estimation by Muscle Deformations With Speed and Ramp Adaptability
Guo, C., Li, Y., Liu, Z., Liu, Y., Yi, J., Wang, Q., Xiong, C., & Guo, J. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3404633 · Cited by 7
“While joint angles are predominantly measured using optical motion capture systems or inertial measurement unit (IMU) [27], [31], [32], these methods are limited by experimental environment, and IMU measurements are susceptible to drift over prolonged periods of use.”
BackgroundIoT-Based Wireless System for Gait Kinetics Monitoring in Multi-Device Therapeutic Interventions
Rathke, C. L., Pimentel, V. C. D. A., Alsina, P. J., Santo, C. C. D. E., & Dantas, A. F. O. D. A. (2024) · Sensors · doi:10.3390/s24175799 · Cited by 7
Multi-Modal Sensing for Propulsion Estimation in People Post-Stroke Across Speeds
Swaminathan, K., Choe, D. K., Kim, D., Barde, F., Baker, T. C., Wendel, N. C., Chin, A., Bergamo, G., Siviy, C., Lee, C., et al. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3577961 · Cited by 11
“In literature, two commonly used wearable sensors for estimating AP GRF during gait are inertial measurement units (IMUs) and pressure insoles [14], [15], [16].”
Gianzina, E., Yiannakopoulos, C. K., Armenis, E., & Chronopoulos, E. (2025) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk10030288 · Cited by 7
“These sensors allow for detailed gait analysis, enabling clinicians to track gait abnormalities over time and develop targeted prehabilitation and rehabilitation strategies to improve functional outcomes before surgery [20,21].”
Jin, H., Wang, W., Zhang, G., Chen, S., Tong, Y., Lu, D., Li, J., He, L., & Tang, X. (2026) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2026.101084 · Cited by 15
“The development of flexible wearable pressure/strain sensors and portable analysis systems has moved gait analysis from the laboratory to the sports field and clinical rehabilitation settings [139].”
Accuracy of the fully integrated Insole3’s estimates of spatiotemporal parameters during walking
Ganguly, A., Olmanson, B. A., Knowlton, C. B., Wimmer, M. A., & Ferrigno, C. (2022) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2022.103925 · Cited by 9
“The most sought-after gait events in the portable assessment of STPs are the temporal parameters of heel-strike and toe-off [28].”
BackgroundA Machine Learning Pipeline for Gait Analysis in a Semi Free-Living Environment
Jung, S., de l′Escalopier, N., Oudre, L., Truong, C., Dorveaux, É., Gorintin, L., & Ricard, D. (2023) · Sensors · doi:10.3390/s23084000 · Cited by 9
“The first two approaches are peak detection [31] and step detection methods [32].”
MethodDemel, J., Plánka, L., Štichhauer, R., Vrtková, A., Bajor, G., Havlíček, M., & Pleva, L. (2023) · Acta chirurgiae orthopaedicae et traumatologiae Cechoslovaca · doi:10.55095/achot2023/008 · Cited by 7
A Review on the Developments in the Field of AI-Based Gait Analysis
Wankhede, V., Verma, P., & Gahane, S. (2024) · DMIHER International Conference on Artificial Intelligence in Healthcare, Education and Industry (IDICAIHEI) · doi:10.1109/idicaiei61867.2024.10842709 · Cited by 7
“Wearable sensor-based gait analysis integrates AI approaches to daily gait analysis, allowing the diagnosis of disorders such as sarcopenia and osteopenia via continuous monitoring [12, 18].”
Ground Contact Time Estimating Wearable Sensor to Measure Spatio-Temporal Aspects of Gait
Bernhart, S., Kranzinger, S., Berger, A., & Peternell, G. (2022) · Sensors · doi:10.3390/s22093132 · Cited by 7
“[20] note that systems combining insole pressure sensors and an IMU, e.”
BackgroundInfluentialYamamoto, A., Fujita, K., Yamada, E., Ibara, T., Nihey, F., Inai, T., Tsukamoto, K., Kobayashi, Y., Nakahara, K., & Okawa, A. (2023) · Gait & Posture · doi:10.1016/j.gaitpost.2023.10.023 · Cited by 7
Fary, C., Cholewa, J. M., Abshagen, S., Andel, D. V., Ren, A. N., Anderson, M. B., & Tripuraneni, K. R. (2023) · Sensors · doi:10.3390/s23146538 · Cited by 8
“, step length, walking speed, double support time, and asymmetry percentage) during activities of daily living [32].”
BackgroundSerial kinematic analysis using inertial measurement units in growing dogs at risk of hip dysplasia
Blättler, P., Altermatt, M., Röhrich, M., & Grütter, N. (2024) · Veterinary and Animal Science · doi:10.1016/j.vas.2024.100385 · Cited by 6
“According to former studies (Marreiros et al., 2017; Mobbs et al., 2022; Park & Yoon, 2021; Prasanth et al., 2021; Yoon et al., 2024) our findings indicate accuracy of IMU systems for detection of traditional metrics as well as the demonstrated clinical relevance of IMU measures.”
ResultAndres, A., Roland, M., Orth, M., & Diebels, S. (2025) · Sensors · doi:10.3390/s25133853 · Cited by 6
Nascimento, D. H. A., Magalhães, F. A., Sabino, G. S., Resende, R. A., Duarte, M. L. M., & Vimieiro, C. B. S. (2022) · Inventions · doi:10.3390/inventions7040098 · Cited by 9
Do we still need to screen our patients?—Orthopaedic scoring based on motion tracking
Raab, D., Heitzer, F., Liaw, J. C., Müller, K., Weber, L., Flores, F. G., Kecskeméthy, A., Mayer, C. U., & Jäger, M. (2023) · International Orthopaedics · doi:10.1007/s00264-022-05670-0 · Cited by 6
Breitman, N., Yona, T., & Fischer, A. G. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3294306 · Cited by 6
“sensors into a single, reliable, low-cost component [2].”
BackgroundRobust and adaptive terrain classification and gait event detection system
Shaikh, U. Q., Shahzaib, M., Shakil, S., Bhatti, F. A., & Malik, A. S. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e21720 · Cited by 6
“Recent research indicates that measuring human movement in real world environments is an active area of interest [9].”
BackgroundFlexible Machine Learning Algorithms for Clinical Gait Assessment Tools
Greve, C., Tam, H., Grabherr, M. G., Ramesh, A., Scheerder, B., & Hijmans, J. M. (2022) · Sensors · doi:10.3390/s22134957 · Cited by 6
“Therefore, the proposed ML workflow provides a new methodology to significantly reduce the burden associated with algorithm training as compared with previous ML-based methods for gait partitioning [8,15].”
BackgroundMethodDong, H., Hou, J., Song, Z., Xu, R., Meng, L., & Ming, D. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.944291 · Cited by 5
“The reliability and feasibility of the combination of the FSRs and IMU in gait phase detection have been proved in previous studies (Prasanth et al., 2021).”
ResultYamamoto, A., Fujita, K., Yamada, E., Ibara, T., Nihey, F., Inai, T., Tsukamoto, K., Kobayashi, Y., Nakahara, K., & Okawa, A. (2023) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-023-06845-5 · Cited by 6
“Among the numerous wearable sensors, inertial measurement units (IMU) are widely used to assess gait in free-living conditions because of their low cost, accuracy, and small size [19, 20].”
BackgroundWearable Devices for Gait Measurement - A Case for Textile-Based Devices
Raji, R. K., Wang, W., Han, J., & Li, N. (2023) · Textile & Leather Review · doi:10.31881/tlr.2023.070 · Cited by 5
Relationship Between Lower-Extremity Co-Contraction and Jerk During Gait
Miyashita, T., Kawanishi, K., & Kudo, S. (2025) · Sensors · doi:10.3390/s25072327 · Cited by 5
Karaman, O., Kömür, A. İ., & Karaman, C. (2026) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2026.118648 · Cited by 7
Huang, J., Wang, X., Jiang, J., Liu, F., Yang, M., Wang, S., Ma, X., & Chen, W. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3664483 · Cited by 6
“However, IMUs alone cannot accurately detect zero velocity moments, particularly in patients with gait disorders [28].”
Challenges and future aspects of sensor technology
Luxton, R. W. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-90222-9.00005-4 · Cited by 5
Development of a new low-cost computer vision system for human gait analysis: A case study
Bernal-Torres, M. G., Medellín-Castillo, H. I., & Arellano-González, J. C. (2023) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119231163634 · Cited by 5
Raza, A., Sekiguchi, Y., Yaguchi, H., HONDA, K., Fukushi, K., Huang, C., Ihara, K., Nozaki, Y., Nakahara, K., Izumi, S., et al. (2024) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2024.106285 · Cited by 5
Qiu, Y., He, Y., Ying, Y., Ma, X., Zhou, H., & Liang, K. (2025) · Applied Intelligence · doi:10.1007/s10489-024-06193-4 · Cited by 5
“For example, Hari [4] demonstrated that wearable sensing devices are instrumental in effectively studying human gait balance issues, crucial for fall detection.”
Slucock, T., Howells, G., Hoque, S., & Sirlantzis, K. (2025) · Journal of Intelligent & Robotic Systems · doi:10.1007/s10846-025-02226-3 · Cited by 6
“Common use cases were determining Gait Events such as heel strikes and toe off as well as swing/stance positions, Spatiotemporal Parameters such as Stride and Step/Step/ Stance Times as well as Gait Velocity and Cadence, and Joint Angles which are most relevant to this paper [12].”
Farra, F. D., Castiglia, S. F., Buzzi, M. G., Brasiliano, P., Angelis, S. D., Paolocci, G., Vasta, S., Marangon, G., Bustos, A. O. O., Bergamini, E., et al. (2025) · Italian National Conference on Sensors · doi:10.3390/s25061764 · Cited by 5
“Wearable inertial measurement units (IMUs) have enhanced gait assessment by providing objective, portable, and accessible alternatives to traditional methods [16,17].”
Liu, X., Zhang, S., Yao, B., Yu, Y., Wang, Y., & Fan, J. (2021) · Review of Scientific Instruments · doi:10.1063/5.0056893 · Cited by 5
Yamamoto, A., Yamada, E., Ibara, T., Nihey, F., Inai, T., Tsukamoto, K., Waki, T., Yoshii, T., Kobayashi, Y., Nakahara, K., et al. (2024) · JMIR mhealth and uhealth · doi:10.2196/55178 · Cited by 5
“The shank and foot are the preferred placements [8,9], and foot kinematics is an important factor related to falls and physical ability [4].”
BackgroundFink, S., Suppanz, M., Oberzaucher, J., Castro, M. A., Fernandes, O., & Alves, I. (2024) · Gait & Posture · doi:10.1016/j.gaitpost.2024.05.033 · Cited by 5
Generation of Gait Events with a FSR Based Cane Handle
Trujillo-León, A., de Guzmán-Manzano, A., Velázquez, R., & Vidal‐Verdú, F. (2021) · Sensors · doi:10.3390/s21165632 · Cited by 5
“The anticipation of gait events may be critical to achieve timely stimulation in real time control or neuroprostheses or functional electrical stimulation [26] and real-time gait analysis is a key issue to control assistive devices such as prostheses and exoskeletons [3].”
BackgroundInfluentialWearable Sensory Apparatus for Real-Time Feedback in Wearable Robotics
Munih, M., Ivanić, Z., & Kamnik, R. (2021) · Applied Sciences · doi:10.3390/app112311487 · Cited by 5
Balasubramaniam, A., Reidsma, D., & Heylen, D. (2023) · International Conference on Human-Agent Interaction (HAI) · doi:10.1145/3623809.3623831 · Cited by 5
“…on this, for example works where someone other than the user (such as a spectator) interacts with the data [66], works where the user interacts with information that is not a running parameter [15, 117, 125, 134], or works where data was collected as part of clinical testing were excluded [75, 98].”
BackgroundBenchmarking of IMU-Based Gait Event Detection Algorithms Across Diverse Terrain Conditions
Trigo, C., Vecchia, P. D., Crenna, F., Torres-Pardo, A., Gómez-García, J. A., Ratto, G., Millán, T. R., de la Torre, R. M. S., Tornero, J., Moreno, J. C., et al. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3596319 · Cited by 4
“Several efforts have been made to automate this procedure using signal processing [18], [19] and machine learning methodologies [20], [21], [22].”
Gait assessment using wearable technologies in neurological disorders: a rapid umbrella
Masurkar, P. P., & Rikame, S. (2025) · Neurodegenerative Disease Management · doi:10.1080/17582024.2025.2560775 · Cited by 7
Ng, G., Gouda, A., & Andrysek, J. (2024) · Sensors · doi:10.3390/s24196431 · Cited by 7
“However, in gait event detection, the upper and lower legs are two of the most common locations [59], suggesting that these locations may be beneficial for identifying gait features relevant to assess changes in gait patterns.”
BackgroundMachine-Learning-Based Validation of Microsoft Azure Kinect in Measuring Gait Profiles
Ferraris, C., Amprimo, G., Cerfoglio, S., Masi, G., Vismara, L., & Cimolin, V. (2024) · Electronics · doi:10.3390/electronics13234739 · Cited by 4
“However, only a few of the proposed solutions have been validated against a gold standard [45–47].”
Deep Learning for Frailty Classification Using IMU Sensor Data: Insights From FRAILPOL Database
Amjad, A., Szczęsna, A., Błaszczyszyn, M., Sacha, J., Sacha, M., Feusette, P., Wolański, W., Konieczny, M., Borysiuk, Z., & Khan, B. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3510626 · Cited by 4
A Multi-IMU System for Assessing Human Walking Dynamics Balance Using the Compass Gait Model
Fan, B., Zhang, L., Wang, Z., Du, M., Cai, S., & Jiang, T. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3563479 · Cited by 4
“The inertial motion capture method offers excellent environmental adaptability and cost-effectiveness while avoiding the time-consuming processes of marker placements and camera calibration [26], [27], [28].”
Onorati, C. R., Sengupta, D., Gomes, N. M., & Kottapalli, A. G. P. (2025) · ACS Applied Engineering Materials · doi:10.1021/acsaenm.5c00834 · Cited by 4
Huang, S., Hou, X., Liu, Y., Shang, P., Luo, J., Lv, Z., Zhang, W., Lin, B., Huang, Q., Tao, S., et al. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.911607 · Cited by 4
“Additionally, with the inertial-sensor gait analysis system integrated into applications, more spatial-temporal gait parameters were available (Prasanth et al., 2021).”
BackgroundMethodDeep Learning-Based Gait Event Prediction through a Single Waist-worn Wearable Sensor
Arshad, M. Z., Lee, D.-H., Jung, D., Jamsrandorj, A., Kim, J., & Mun, K.-R. (2023) · International Conference on Consumer Electronics · doi:10.1109/icce56470.2023.10043541 · Cited by 4
“The inertial measurement unit (IMU) sensors, the most widely used wearable sensors [11], are typically attached to various parts of the subject while he walks and movement trajectories are recorded and analyzed to detect gait events [12]–[14].”
BackgroundHuman activity tracking using wearable sensors in loose-fitting clothes: survey
Fadhil, M. A., & Shareef, W. F. (2023) · TELKOMNIKA (Telecommunication Computing Electronics and Control) · doi:10.12928/telkomnika.v21i6.24196 · Cited by 5
Vavasour, G., Giggins, O. M., Flood, M. W., Doyle, J., Doheny, E. P., & Kelly, D. (2023) · PLoS ONE · doi:10.1371/journal.pone.0286707 · Cited by 5
“As acceleration signals increase in magnitude from the head to the ankle, highest activity recognition accuracy is anticipated from a sensor positioned at the ankle [30] and as a body-location for sensor-positioning the ankle is the most frequently recommended [36].”
BackgroundCross-step detection using center-of-pressure based algorithm for real-time applications
Zadravec, M., & Matjačić, Z. (2024) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-024-01460-4 · Cited by 4
“Conventionally, online gait event detection algorithms rely on various sensors (Inertial Measurement Units – IMU, pressure insoles, angular sensors or optical tracking systems) attached to the lower limbs or body to capture the kinematics of movement [4–7].”
BackgroundComparative assessment of heel rise detection for consistent gait phase separation
Salminen, M., Perttunen, J., Avela, J., & Vehkaoja, A. T. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e33546 · Cited by 3
“Among the various methods of measuring gait using IMU ’ s, the utilization of a single shank-mounted sensor has gained prominence [3].”
MethodLucot, Q., Beurienne, E., & Behr, M. (2024) · Sensors · doi:10.3390/s24216927 · Cited by 6
“The gait information was shown to be more stable and more accurate with foot-mounted sensors rather than trunk or shank-mounted ones [31–33].”
BackgroundVacheva, D. E., & Drumev, A. (2025) · Sensors · doi:10.3390/s25144435 · Cited by 3
“By enabling objective measurement and longitudinal monitoring, WS support data-driven clinical decisions and personalized therapeutic interventions [20].”
Descollonges, M., Moreau, B., Feppon, N., Abdoun, O., Séguin, P., Popović‐Maneski, L., Marco, J. D., & Metani, A. (2025) · Bioengineering · doi:10.3390/bioengineering12090960 · Cited by 3
“However, non-wearable systems such as GAITRite ® are restricted to controlled research environments and do not allow gait analysis during regular daily activities [1,6].”
Fu, Z., Lin, Y., Xu, G., & Zhang, M. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3623132 · Cited by 3
“Currentresearchonlocomotionmodesprediction mainlyreliesonhumankinematicsinformationorneuromuscu-larinformation,focusingonimprovingtheaccuracyandfluency oflocomotionmodespredictionalgorithms[13].”
Hong, S., Choi, H., & Kweon, H. (2025) · JMIR Rehabilitation and Assistive Technologies · doi:10.2196/80748 · Cited by 5
“Such systems have the potential to make gait analysis more portable, cost-effective, and clinically scalable [6,10,13].”
Kumar, V., Parvin, N., Joo, S. W., Mandal, T. K., & Park, S. (2026) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2026.103870 · Cited by 3
Gong, J., Li, Z., Chen, M., Wang, H., & Hu, D. (2023) · Sensors · doi:10.3390/s23125417 · Cited by 3
“Due to the uniformity of the foot morphology, it is common to use the judgment method of plantar pressure [34] net value for a quick moment-to-moment judgment of whether there is a touchdown.”
Uchaipichat, N., Tangjirachaipoka, A., & Chamninavakul, C. (2024) · International Conference on Biomedical Imaging, Signal Processing (ICBSP) · doi:10.1145/3707172.3707195 · Cited by 3
“A systematic review of wearable sensor-based gait detection systems has affirmed their applicability in continuous monitoring and early PD detection 9.”
Dong, D., Zhu, N., Wang, J., & Li, Y. (2025) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2025.110286 · Cited by 3
Real-Time Estimation of Lower Limb Posture and Joint Angles Using Wearable IMUs:
Kanega, S., & Muraoka, Y. (2025) · Japanese Journal of Comprehensive Rehabilitation Science · doi:10.11336/jjcrs.16.19 · Cited by 3
Simplified Markerless Stride Detection Pipeline (sMaSDP) for Surface EMG Segmentation
Aguiar, R. C., Raj, E. J. S. J., & Chakrabarty, S. (2023) · Sensors · doi:10.3390/s23094340 · Cited by 3
“[5], [6], [7]), this technology is widely employed today and used as a benchmark for other motion capture systems (see [8] for an up-to-date review).”
BackgroundInfluentialSun, W., Lu, G., Zhao, Z., Guo, T., Qin, Z., & Yu, H. (2023) · Entropy · doi:10.3390/e25060837 · Cited by 3
Smart Gait Healthcare Applications: Walking Status and Gait Biometrics
Chen, T., & Lee, Y. (2024) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-031-59443-4_4 · Cited by 4
Tamburella, F., Lorusso, M., Merone, M., Bacco, L., Molinari, M., Tramontano, M., Scivoletto, G., & Tagliamonte, N. L. (2024) · Healthcare · doi:10.3390/healthcare12181840 · Cited by 3
“…last decades, due to the technological developments in rehabilitation bioengi-neering, which leverages continuously evolving fields such as robotics [16], wearable and environmental sensors [17–19], virtual reality [20,21], and many others, new devices have been introduced in the clinical setting.”
BackgroundTextile Pressure Sensors: Innovations and Intellectual Property Landscape
Barbieri, M., & Andreoni, G. (2024) · International Electronic Conference on Sensors and Applications (ECSA) · doi:10.3390/ecsa-11-20512 · Cited by 3
“The multifunctionality of these textiles is particularly beneficial in healthcare where they ca be used for patient monitoring, in sports where they ca be employed for performance tracking, and in ergonomic studies, where they ca be used to assess body posture and movement [2–7].”
Do the gait domains change in PD patients with freezing of gait during their ‘interictal’ period?
Zhao, J., Liu, C., Wan, Y., Zhu, X., Song, L., Liu, Z., & Gan, J. (2025) · BMC Geriatrics · doi:10.1186/s12877-024-05673-z · Cited by 4
A Miniaturized Flexible Surface Electromyography Sensor With an Integrated Localization Concept
Balbach, S., Kolpak, J., Dorn, C., Brückner, S., Schlechtweg, N., Gambietz, M., Koelewijn, A. D., Vossiek, M., & Hagelauer, A. (2025) · IEEE Microwave Magazine · doi:10.1109/mmm.2024.3494717 · Cited by 5
“This encompasses, in particular, the neural processes that give rise to mechanical muscle contraction as these are [17], [30], [31], [32], [33], [34] Proposed HEKF-based system • Enables additional measurements (e.g., sEMG) • sEMG sensors with integrated RF transmitters can be worn under clothing •…”
A Reliability Study of Small, Portable, Easy-to-Use, and IMU-Based Sensors for Gait Assessment
Kochman, M. T., Kielar, A., Kasprzak, M., Kasperek, W., Dutko, M., Vellender, A., Przysada, G., & Drużbicki, M. (2025) · Sensors · doi:10.3390/s25216597 · Cited by 3
Experimental analysis of quaternion-based attitude estimation algorithms
Du, Q., Ding, B., & Wei, Y. (2024) · Chinese Control and Decision Conference (CCDC) · doi:10.1109/ccdc62350.2024.10587760 · Cited by 2
“Its application in wearable devices is also becoming increasingly widespread [1].”
BackgroundMituniewicz, A., Hong, W., Lewek, M. D., & Huang, H. (2024) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob60516.2024.10719818 · Cited by 3
“These requirements can add both computational, physical, and financial costs [4] and may cause gait cycles to be over or under estimation [9], [11].”
BackgroundInfluentialManni, A., Rescio, G., Carluccio, A. M., Caroppo, A., & Leone, A. (2025) · Sensors · doi:10.3390/s25051305 · Cited by 2
“Wearable sensors, such as accelerometers, gyroscopes, and Inertial Measurement Units (IMUs), have emerged as a portable alternative [7,8].”
Huang, B., Lv, J., & Qiang, L.-G. (2025) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255842.2025.2495251 · Cited by 3
“In healthy individuals, a complete gait cycle consists of heel strike, toe strike, heel off, toe off, and the swing phase (Prasanth et al. 2021).”
Gait Phase Recognition Based on Wearable Inertial Sensing Technology
Lin, C. (2024) · International Conference on Sports Technology and Performance Analysis (ICSTPA) · doi:10.1145/3723936.3723946 · Cited by 2
“The sensors are usually worn on key frame elements, including the lower limbs and waist, to as it should be seize the dynamic traits of human gait [5].”
Sarathi, T., Dinakar, B., Venkataraman, K. K., & Bhattacharyya, A. (2025) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2025.112813 · Cited by 2
BHIS: A Bayesian–Heuristic Inference System for Recognition of Walking Gait Phases
Mohamed, S. A., & Martínez-Hernández, U. (2025) · IEEE Transactions on Systems Man and Cybernetics Systems · doi:10.1109/tsmc.2025.3601893 · Cited by 2
“The early approaches to gait phase recognition involved simple, rule-based methods [18], which were largely based on kinematic and kinetic data.”
Wearable AI-Driven Smart Insole for Long-Term Monitoring of Lower-Limb Joint Mobility: A Pilot Study
Zhang, D., Huang, Y., Liu, Y., Ding, Z., Guo, L., & Zhou, D. (2025) · Lecture notes in computer science · doi:10.1007/978-981-95-2098-5_46 · Cited by 3
Precision of an Inertial System to Evaluate the Finger Tapping Test in Women with Fibromyalgia
Brígida, N., Catela, D. P. R., Mercê, C., & Branco, M. (2025) · Sports · doi:10.3390/sports13110373 · Cited by 3
“Adaptive filtering, machine learning-based threshold adjustment, and calibration routines tailored to individual motor profiles may enhance the robustness and generalizability of IMU-based assessments, which have been applied not only in FTT but also to other tasks, namely, walking gait [35,67].”
Gait Parameters of Women Before Knee Joint Arthritis—Analysis Using the MoKA System
Kuś, M., Wasiuk-Zowada, D., Herman, K., Cholewiński, J., & Knapik, A. (2025) · Sensors · doi:10.3390/s26010136 · Cited by 2
“…sensors are as accurate as those using optical sensors, and their advantages include the absence of the aforementioned limitations related to laboratory testing, low cost, and ease of use (transferability) [19,26], which makes IMUs currently the most commonly used sensors for gait analysis [27–29].”
Yang, S., Yu, K., Zhang, L., Pan, M., Pan, H., Chen, L., & Guo, X. (2026) · Biomimetics · doi:10.3390/biomimetics11010026 · Cited by 2
“These approaches are attractive for their robustness and conceptual simplicity: transitions are triggered using foot-switch signals, force thresholds, or characteristic angular patterns, often detected from kinematic or kinetic features [19–21].”
InfluentialSmart self-powered insoles for real-time fall risk detection
Zhang, Y., Yan, Y., Wallis, N., Sheng, W., Zhu, B., Zhang, Z., Chen, Q., & Zhang, F. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.173190 · Cited by 2
Paolo, S. D., Mendicino, M., Santos, J., Nijmeijer, E. M., Heuvelmans, P., Villa, F. D., Gokeler, A., Benjaminse, A., & Zaffagnini, S. (2026) · Sensors · doi:10.3390/s26030988 · Cited by 2
Huang, X., Xu, J., & Chen, L. (2026) · Digital Health · doi:10.1177/20552076261462645 · Cited by 2
“29,30 The external responsiveness and metrological validity of wearable sensors in continuous monitoring scenarios represent an important practical consideration; recent work has examined the responsiveness of wearable devices to exercise-induced physiological changes, 31 underscoring that…”
Smart Gait Detection and Analysis
Chen, T., & Lee, Y. (2024) · SpringerBriefs in applied sciences and technology · doi:10.1007/978-3-031-59443-4_3 · Cited by 2
Metrological Characterization of a Wearable Device for the Assessment of Gait Parameters
Panni, L., Cosoli, G., Arnesano, M., Citarelli, F., Antognoli, L., & Scalise, L. (2024) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea60663.2024.10596895 · Cited by 2
“However, recently reliable, affordable, and wearable sensors have enabled data collection in real-life conditions [15], [16].”
BackgroundA Machine Learning Model for Predicting Critical Minimum Foot Clearance (MFC) Heights
Asogwa, C. O., Prokofieva, M., Sarashina, E., Sarashina, E., & Sankai, Y. (2024) · Applied Sciences · doi:10.3390/app14156705 · Cited by 3
Shafi, S., Priya, R. P., Reddy, R. N., Bhuvanesh, R., Jennifer, M., & Adhil, M. (2024) · International Conference on Intelligent Technologies (CONIT) · doi:10.1109/conit61985.2024.10626258 · Cited by 3
“Authors in [8] have presented a systematic review on gait detection models using Wearable devices equipped with accelerometers, gyroscopes, and other sensors have been widely used for gait analysis.”
BackgroundRentz, C., Kaiser, V., Jung, N., Turlach, B. A., Far, M. S., Peterburs, J., Boltes, M., Schnitzler, A., Amunts, K., Dukart, J., et al. (2024) · Sensors · doi:10.3390/s24175598 · Cited by 3
“In systematic reviews [8,35], pelvis, shank, and feet have been named as the preferred segments for wearable sensor placement.”
BackgroundResult
Metadata
- Authors
- Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J.
- Affiliations
- Delft University of Technology (NL)
- École Polytechnique Fédérale de Lausanne (CH)
- Centre Hospitalier Universitaire Vaudois (CH)
- Erasmus MC (NL)
- ONWARD, EPFL Innovation Park Building C, 1015 Lausanne, Switzerland
- Corresponding author
- Vallery, Heike
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-04-13
- Volume
- 21
- Issue
- 8
- Pages
- 2727
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC8069962
- OpenAlex
- W3154710845
- Cited by
- 348
- References
- 140
- Citations by year
- 2026: 79 · 2025: 83 · 2024: 79 · 2023: 50 · 2022: 40 · 2021: 17
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (publishedVersion, cc-by)
- SERVAL (Université de Lausanne) (publishedVersion, cc-by)
- IRIS (submittedVersion, cc-by)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Research Repository (Delft University of Technology) (submittedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Funders
- Horizon 2020 Framework Programme (779963)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- wearable sensors, gait analysis, inertial measurement unit, insole pressure sensors, heel strike detection, toe-off detection, pathological gait, gait rehabilitation, neural prostheses, rule-based detection, sensor placement
- MeSH terms
- Wearable Electronic Devices, Gait Analysis, Activities of Daily Living, Biomechanical Phenomena, Gait, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.