The DOI matches its Crossref record; 140 of the 140 references it cites were found in a registry or an index.
Wearable Sensor-Based Real-Time Gait Detection: A Systematic Review
Open accessAbstract
Gait analysis has traditionally been carried out in a laboratory environment using expensive equipment, but, recently, reliable, affordable, and wearable sensors have enabled integration into clinical applications as well as use during activities of daily living. Real-time gait analysis is key to the development of gait rehabilitation techniques and assistive devices such as neuroprostheses. This article presents a systematic review of wearable sensors and techniques used in real-time gait analysis, and their application to pathological gait. From four major scientific databases, we identified 1262 articles of which 113 were analyzed in full-text. We found that heel strike and toe off are the most sought-after gait events. Inertial measurement units (IMU) are the most widely used wearable sensors and the shank and foot are the preferred placements. Insole pressure sensors are the most common sensors for ground-truth validation for IMU-based gait detection. Rule-based techniques relying on threshold or peak detection are the most widely used gait detection method. The heterogeneity of evaluation criteria prevented quantitative performance comparison of all methods. Although most studies predicted that the proposed methods would work on pathological gait, less than one third were validated on such data. Clinical applications of gait detection algorithms were considered, and we recommend a combination of IMU and rule-based methods as an optimal solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


![Figure 1 Word cloud showing most frequently occurring keywords present in search results for a search query in Scopus (for instance, see Table 2), visualized by the software VOS-Viewer [35]. The size of each node indicates the relative relevance (based on the frequency of occurrence of keywords) of that topic among the list of articles returned by the search query. Connections between nodes were not used in refining the search terms.](https://figures.cochat.ai/paper-figures/8276573029d14706b8534ad4cde594cf/wearable-sensor-based-real-time-gait-detection-a-systematic-review-figure-1.jpg)





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The first is methodological heterogeneity in sensor placement, feature extraction, and analysis pipelines across studies, compounded by the absence of task-optimized sensor configurations (Prasanth et al., 2021; Niswander et al., 2020).”
From Multimodal neuroimaging and AI integration in cognitive disorders: advances, challenges, and future directions for precision medicine (2026) · cites this paper as Prasanth et al., 2021
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PRISMA-P Group, Moher, D., Shamseer, L., Clarke, M., Ghersi, D., Liberati, A., Petticrew, M., Shekelle, P., & Stewart, L. A. (2015) · Systematic Reviews · doi:10.1186/2046-4053-4-1 · Cited by 26,223 · cited 1×
“We therefore performed a systematic review and meta-analysis across the four major scientific databases mentioned earlier, following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) standard [21], covering 1262 articles, as will be discussed in the next sections.”
MethodSoftware survey: VOSviewer, a computer program for bibliometric mapping
van Eck, N. J., & Waltman, L. (2010) · Scientometrics · doi:10.1007/s11192-009-0146-3 · Cited by 21,484
Wavelets and signal processing
Rioul, O., & Vetterli, M. (1991) · IEEE Signal Processing Magazine · doi:10.1109/79.91217 · Cited by 2,786
The role of google scholar in evidence reviews and its applicability to grey literature searching
Haddaway, N. R., Collins, A. M., Coughlin, D., & Kirk, S. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138237 · Cited by 2,387 · cited 1×
“[28] classified scientific literature databases into two categories: Academic Citation Database (ACDB) and Academic Citation Search Engine (ACSE).”
BackgroundEstimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068
Nonlinear Complementary Filters on the Special Orthogonal Group
Mahony, R., Hamel, T., & Pflimlin, J.-M. (2008) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2008.923738 · Cited by 1,751
Targeted neurotechnology restores walking in humans with spinal cord injury
Wagner, F. B., Mignardot, J.-B., Le Goff-Mignardot, C. G., Demesmaeker, R., Komi, S., Capogrosso, M., Rowald, A., Seáñez, I., Caban, M., Pirondini, E., et al. (2018) · Nature · doi:10.1038/s41586-018-0649-2 · Cited by 1,087 · cited 7×
“We categorized the target impairments into two classes based on how they were presented in the respective studies—first, generally diminished ambulatory function, where gait is impaired due to general degeneration of the locomotor system, such as with Parkinson’s disease, osteoarthritis, Huntington’s disease, diplegic…”
BackgroundInfluentialSelf-citationSpatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P.-F., & Robert, P. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 814 · cited 1×
“[80] reported that TO and HS events consist of combined features that can be well resolved in the time-frequency domain.”
BackgroundAssessment of Walking Features From Foot Inertial Sensing
Sabatini, A. M., Martelloni, C., Scapellato, S., & Cavallo, F. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.840727 · Cited by 650
VOS: A New Method for Visualizing Similarities between Objects
van Eck, N. J., & Waltman, L. (2006) · RePub (Erasmus University Rotterdam) · Cited by 633
Research works printed but not linked: 1
- Lee, 1994, Wavelet analysis: Theory and applications, Hewlett Packard J., 45, 44
Cited by
Items 301–348 of 348
Li, H., Ma, J., Cao, B., Ren, X., Chen, Y., Guo, Q., Li, B., Baryskievic, I. A., Baryskievic, A., & Tsviatkou, V. (2026) · Fractal and Fractional · doi:10.3390/fractalfract10050297 · Cited by 2
Manjunath, M., Shankar, T. A. G., Shiraguppi, N., & Gupta, S. (2026) · IEEE International Conference on Communication Systems and Network Technologies (CSNT) · doi:10.1109/csnt69054.2026.11502324
“The classification is obtained by each of the trees and the majority decision leads to the final answers [19-21].”
A Low-Cost Wearable Insole System Using FSR for Real-Time Gait Analysis
Chotara, P., Pathak, Y., & Semwal, V. B. (2025) · IEEE International Conference on Recent Trends in Computing and Smart Mobility (RCSM) · doi:10.1109/rcsm67767.2025.11506874
“It is key to developing control systems for prosthetics, exoskeletons, and Functional Electrical Stimulation (FES) devices, allowing them to move naturally in sync with the user [5, 6, 7].”
Marciniak, P., & Zubert, M. (2026) · Sensors · doi:10.3390/s26103038
“From a sensor configuration perspective, recent literature indicates a shift from highly instrumented laboratory setups to more transferable, consumer-grade sensing solutions [14,15,21,23].”
Chamorro-Atalaya, O. (2026) · Sensors · doi:10.3390/s26103164
“…of wearable systems identified in the present review reflects broader patterns in gait analysis, in which inertial measurement units (IMUs) have been widely used in real-time gait detection and monitoring frameworks and are commonly positioned on lower-limb segments such as the shank or foot [92].”
Integrated IMU-EMG Wearable System for Real-Time Gait Analysis and an Audio Feedback System
Ponnibala, M., Divija, N., Gokulanand, C. K., & Dharani, R. (2026) · International Conference on Multidisciplinary Innovations for Smart & Sustainable Future (MISSF) · doi:10.1109/missf68264.2026.11522072
“Prasanth et al. (2021), in "Wearable sensor-based real-time gait detection: A systematic review," offered an in-depth review of the current techniques of RWHTs for the detection of walking events and phases and the associated methods using IMU, pressure sensors, and EMG.”
Zwicky, E., Nedergaard, N. J., Alkjær, T., Linnebjerg, C., Nikolajsen, M. M., Lauridsen, H. B., & Zebis, M. K. (2026) · Sensors · doi:10.3390/s26113539
“With the rapid development of wearable technologies [17,18], several studies have explored the use of inertial measurement units (IMUs) for in-field IC detecting during running, e.g., [19–22].”
Advanced Machine Learning Approaches in Human-Machine Interaction for Rehabilitation Exoskeleton
Albrethen, A. K., Majmaie, S. A., & Amsaad, F. (2026) · IEEE International Conference on Secure IoT, Assured and Trusted Computing (SATC) · doi:10.1109/satc69565.2026.11542534
SmartPant: A Pediatric Wearable for Real-Time Gait and Mobility Assessment
Sarkar, S., Vuong, L., Phung, S., Ritchie, H., Aguilar-Herrera, A. J., Morshedzadeh, E., Willson, P. A., & Contreras-Vidal, J. L. (2026) · IEEE Dallas Circuits and Systems Conference (DCAS) · doi:10.1109/dcas69364.2026.11544658
“Recent gait analysis studies using wearable sensors primarily focus on the Inertial Measurement Unit (IMU), with a few incorporating surface electromyography (sEMG) [7].”
Evaluating the Accuracy of Monocular 3D Pose Estimation for Gait Analysis
Xing, X., Moro, M., & Odone, F. (2026) · ACM Symposium on Applied Computing · doi:10.1145/3748522.3779919 · Cited by 1
“To overcome these limitations, recent research has explored wearable devices such as inertial measurement units (IMUs) and pressure sensors, enabling real-time monitoring of gait events and extraction of spatiotemporal parameters using machine learning techniques [17].”
Cheng, J., & Li, Z. (2026) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-026-01792-9 · Cited by 1
“Liang et al. [13] demonstrated IMU breakthroughs in motion capture precision; Donisi et al. [14] and Kobsar et al. [15] systematically reviewed IMU validity and reliability in gait analysis, confirming centi-metre-level accuracy across diverse populations [16, 17].”
Clinical Implementation of Gait Monitoring in Orthopaedic Rehabilitation
Chaudhry, A., Fullara, M., & Pandey, M. (2026) · Biomedical engineering · doi:10.5772/intechopen.1016298
Martínez-Pozo, V., Barbado, D., Díaz-Marín, C., Campos, J. G., Blasco‐Peris, C., Ros‐Arlanzón, P., Moreno-Navarro, L., Popivanov, I. D., Mehrabian-Spasova, S., Traykov, L., et al. (2026) · Brain Sciences · doi:10.3390/brainsci16070662
“From the authors’ perspective, the observation of high relative reliability (i.e., high ICC values), despite the large absolute test–retest error (i.e., high MDC), may be explained by the fact that ICC estimates depend on the ratio between-subject and within-subject variability [53].”
Blandeau, M., Mathieu, E., Kubiak, R., Wallard, L., & Persine, S. (2026) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2026.113444
Medhir, A. (2026) · Research Square · doi:10.21203/rs.3.rs-10110508/v1
Comparison of digital gait study methods (non-systematic review)
Александрович, Ч. А., Fedoseev, A. V., Kulakova, A. V., Kiseleva, P. A., Alpatov, A. V., & Ashapkina, M. S. (2026) · I P Pavlov Russian Medical Biological Herald · doi:10.17816/pavlovj636274
Macq, L., Dehem, S., Lejeune, T. M., & Otlet, V. (2026) · Neurorehabilitation · doi:10.1177/10538135261463255
“By measuring plantar pressure distribution, these devices allow the estimation of step count as well as gait parameters such as gait cycle duration, swing and stance durations, and foot-ground interaction events including heel strike and toe-off (Ngueleu et al., 2019; Prasanth et al., 2021).”
CAGAID: Context-Aware Gait Anomaly-Based Intrusion Detection
Yamout, Y., Iqbal, S., & Zulkernine, M. (2026) · Lecture notes in computer science · doi:10.1007/978-3-032-20732-6_8
Wearable Instrumented Insoles for Continuous Gait Monitoring for Daily-Life Rehabilitation Support
Comai, S., Bettola, M., Varisco, A., Vignati, G., & Salice, F. (2026) · Lecture notes in computer science · doi:10.1007/978-3-032-31285-3_26
Ruscelli, M., Fetta, A., Benvenuti, E., Bisi, M. C., Stagni, R., Zardi, E., Sansavini, A., Corvaglia, L., Cordelli, D. M., & Aceti, A. (2026) · European Journal of Pediatrics · doi:10.1007/s00431-026-07252-3
“…used as a reliable method for real-time gait analysis in adults and adolescents with gait impairments (amputees, people with neurological diseases or traumatic brain or spinal cord lesions), their application in the paediatric field is limited and mainly related to research activities [38, 50].”
Wang, J., Li, J., Xiao, Q., Li, J., Wang, H., Liang, X., Wu, S., Wang, Y., Cui, M., Chen, X., et al. (2026) · GeroScience · doi:10.1007/s11357-026-02428-z
A Sensor-Data–Driven Computational Approach for Gait Phase Detection in Foot Drop Assist Devices
Divya, B., Nithya, R., Anupam Bhaskarbhatta, B., & Swaminathan, A. (2026) · International Conference on Computer Networks, Big Data and IoT (ICCBI) · doi:10.1109/iccbi68589.2026.11619875
Yang, Q., & Zhang, T. (2026) · Digital Health · doi:10.1177/20552076261474014
“The patient-focused segment is the most prominent, encompassing disease prediction and diagnosis (e.g., AF detection 70 ), therapeutic intervention (e.g., smart wound dressings 71–73 ), and long-term physiological tracking (e.g., heart rate, gait analysis 74 ).”
Shenoy, A., Beyer, K. B., McIlroy, W. E., Ooteghem, K. V., Weber, K. S., Eng, J. J., Yao, J., Dukelow, S. P., Leung, G., Hill, M. D., et al. (2026) · Sensors · doi:10.3390/s26154881
“Consequently, the current recommendation for accurate accelerometer-based gait detection in individuals with slower gait speeds is to place sensors on the lower limb, as this provides more precise measurements of gait cycle kinematics (e.g., heel strike, toe-off) [32,33].”
Zhou, Z., & Liang, K. (2026) · Applied Sciences · doi:10.3390/app16157661
Haas, D., Vogel, C., Meierhofer, C. N., Hofmann, K., Maisenbacher, T. C., Menger, M. M., Herath, S. C., Histing, T., & Braun, B. J. (2026) · Sensors · doi:10.3390/s26154843
“In this context, wearable sensor-based approaches, particularly those using inertial measurement units, have increasingly been applied to characterize gait events and pathological gait beyond conventional activity measures [34].”
Nagaraja, S., Rubio, J. E., Subramaniyan, M., Tong, J., Baggaley, M., Edwards, W. B., & Jaques Reifman, A. (2026) · Frontiers in Physiology · doi:10.3389/fphys.2026.1905928
“…sensors show promise for real-time gait assessment and tibial loading estimation, we still lack validated tools to monitor and predict at the individual level how changes in gait patterns during training or fi eld exercises affect tibial SF risk (Matijevich et al., 2020; Prasanth et al., 2021).”
A Real-Time IMU-Based Framework for Detecting Distraction- and Fatigue-Induced Gait Alterations
Ye, L., He, C., Huang, C., Chen, R., Liu, X., & Yu, L. (2026) · International Conference on Artificial Intelligence and Computing (AIC) · doi:10.1109/aic65131.2026.11633768
“This gap underscores the need for a mobile, wearable system capable of continuously monitoring and detecting distraction-and fatigue-induced gait changes in everyday settings [3].”
Pană, C. F., Pătrașcu-Pană, D. M., Maican, C. A., & Rădulescu, V. M. (2026) · Actuators · doi:10.3390/act15080431
STAG-Net: A Spatial–Temporal Attention-Guided Network for Pathological Gait Classification
Frad, A., D’Alessandro, T., Fontanella, F., Nardone, E., Pace, C. D., Basly, H., & Sayadi, F. Z. (2026) · Big Data and Cognitive Computing · doi:10.3390/bdcc10100348
Saberi, K., Abbood, R. S., Al-Taie, S. F., Smerat, A., Abdullayev, M. M., Maksudova, M. K., Hedayatinia, M., Zarei, A., Nourizadeh, M., Ghahari, A., et al. (2026) · Veterinary Medicine and Science · doi:10.1002/vms3.71152
“Recent studies suggest that CNNs trained on multi-site IMU data can differentiate healthy gait patterns from those associated with neurological and orthopaedic disease, with multiclass classification accuracies above 90% in selected datasets (X. Zhang et al. 2022 ; Prasanth et al. 2021 ).”
Vivar, G., Singh, S., Bea, T., Saal, C., Munoz-Martel, V., & Schega, L. (2026) · Bioengineering · doi:10.3390/bioengineering13080924
“To overcome these constraints, the increasing availability of mobile devices equipped with inertial measurement units (IMUs) provides a practical, low-cost alternative for collecting temporal gait kinematics [11,12].”
Bian, Y., Huang, X., Wu, B., & Nishimura, S. (2026) · Electronics · doi:10.3390/electronics15173913
Na, J.-M., Song, M., Park, H., Choi, I., Lee, J., Yoon, J., & Han, J. (2026) · Revista de Neurología · doi:10.31083/rn53766
“Wearable sensing technologies enable real-time gait phase detection [11], allowing stimulation to be linked to specific phases of the gait cycle.”
Shank angular deceleration as a weight-acceptance marker in healthy and hip osteoarthritis walking
Salminen, M., Perttunen, J., Avela, J., & Vehkaoja, A. T. (2026) · Gait & Posture · doi:10.1016/j.gaitpost.2026.110630
Three-Axis Distance Estimation Using an Inertial Measurement Unit
Kongpramot, C., Auysakul, J., Stojanović, G., & Chatpun, S. (2026) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-032-29116-5_22
Haider, S. M. J., & Takhakh, A. M. (2026) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-026-06737-4
“Comparable three-region plantar segmentation has been used to characterise loading patterns in recent wearable systems [ 22], and in-shoe pressure arrays have been applied to real-time gait monitoring more broadly [23 , 24 ].”
Zhang, B., Li, Y., Zhang, G., Fu, M., Zhang, Y., Zhao, R., Li, P., & Wei, X. (2026) · Research Square · doi:10.21203/rs.3.rs-10816633/v1
Farmanesh, A., Ordieres-Meré, J. B., Sanchis, R. G., & Aladro-Benito, Y. (2026) · Digital Health · doi:10.1177/20552076261488885
Kongsatan, P., Kla-arsa, S., Niamsang, W., Chaiwan, P., Thaweephong, P., Chaisumritchoke, S., & Samala, M. (2026) · Research Square · doi:10.21203/rs.3.rs-10927660/v1
Ravindrakumar, S., S, P. M., Arul Akash, S., Rathinavel, M., & Hariprasad, R. (2026) · International Conference on Smart Communication and Sustainable Technologies (ICSCST) · doi:10.1109/icscst70031.2026.11709734
Ankle-motion-related artifact in shank-mounted IMU posture measurements during gait
Salminen, M., Perttunen, J., Avela, J., & Vehkaoja, A. T. (2026) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2026.113607
Wearable Sensor Systems for Healthcare and Rehabilitation
Bhansali, P., Purohit, A., & Goswami, L. (2026) · Advances in computational intelligence and robotics book series · doi:10.4018/979-8-2600-2393-8.ch012
Li, L., Mi, Y., Gao, X., Wang, X., Lu, Y., & Wang, Z. (2026) · Actuators · doi:10.3390/act15100531
Li, J., Chen, S., Li, X., Liu, Z., Xu, T., Wang, Y., Hu, X., Wang, J., Yang, P., Zhao, X., et al. (2026) · Fire · doi:10.3390/fire9100447
Ena, A., Olmedo, J. J. S., Mazzà, C., Belachew, S. M., & Reyes, Ó. (2026) · Sensors · doi:10.3390/s26206582
“For these reasons, current literature [3] increasingly positions rule-based methods not as standalone solutions, but as efficient preprocessing stages within hybrid architectures.”
InfluentialLira-Zamacona, M. A., León-Hernández, A. D., López‐López, C. O., & Martínez‐Hernández, A. (2026) · Journal of Functional Morphology and Kinesiology · doi:10.3390/jfmk11040433
“Prasanth et al. [23] focused on real-time detection methods and their application to pathological gait, whereas Lin et al. [24] found that gyroscopes remain the primary tool for detecting gait events, while using the full IMU (gyroscope + accelerometer) improves reliability and enables estimation…”
Metadata
- Authors
- Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J.
- Affiliations
- Delft University of Technology (NL)
- École Polytechnique Fédérale de Lausanne (CH)
- Centre Hospitalier Universitaire Vaudois (CH)
- Erasmus MC (NL)
- ONWARD, EPFL Innovation Park Building C, 1015 Lausanne, Switzerland
- Corresponding author
- Vallery, Heike
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2021-04-13
- Volume
- 21
- Issue
- 8
- Pages
- 2727
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC8069962
- OpenAlex
- W3154710845
- Cited by
- 348
- References
- 140
- Citations by year
- 2026: 79 · 2025: 83 · 2024: 79 · 2023: 50 · 2022: 40 · 2021: 17
- FWCI
- 3.93
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (publishedVersion, cc-by)
- SERVAL (Université de Lausanne) (publishedVersion, cc-by)
- IRIS (submittedVersion, cc-by)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Infoscience (Ecole Polytechnique Fédérale de Lausanne) (submittedVersion, cc-by-nc-nd)
- Research Repository (Delft University of Technology) (submittedVersion, cc-by)
- Data Archiving and Networked Services (DANS) (submittedVersion, other-oa)
- Funders
- Horizon 2020 Framework Programme (779963)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Keywords
- wearable sensors, gait analysis, inertial measurement unit, insole pressure sensors, heel strike detection, toe-off detection, pathological gait, gait rehabilitation, neural prostheses, rule-based detection, sensor placement
- MeSH terms
- Wearable Electronic Devices, Gait Analysis, Activities of Daily Living, Biomechanical Phenomena, Gait, Humans
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.