CoChat

Securing Industrial Control Systems: Components, Cyber Threats, and Machine Learning-Driven Defense Strategies

Open access

The DOI matches its Crossref record; 131 of the 131 references it cites were found in a registry or an index.

Abstract

Industrial Control Systems (ICS), which include Supervisory Control and Data Acquisition (SCADA) systems, Distributed Control Systems (DCS), and Programmable Logic Controllers (PLC), play a crucial role in managing and regulating industrial processes. However, ensuring the security of these systems is of utmost importance due to the potentially severe consequences of cyber attacks. This article presents an overview of ICS security, covering its components, protocols, industrial applications, and performance aspects. It also highlights the typical threats and vulnerabilities faced by these systems. Moreover, the article identifies key factors that influence the design decisions concerning control, communication, reliability, and redundancy properties of ICS, as these are critical in determining the security needs of the system. The article outlines existing security countermeasures, including network segmentation, access control, patch management, and security monitoring. Furthermore, the article explores the integration of machine learning techniques to enhance the cybersecurity of ICS. Machine learning offers several advantages, such as anomaly detection, threat intelligence analysis, and predictive maintenance. However, combining machine learning with other security measures is essential to establish a comprehensive defense strategy for ICS. The article also addresses the challenges associated with existing measures and provides recommendations for improving ICS security. This paper becomes a valuable reference for researchers aiming to make meaningful contributions within the constantly evolving ICS domain by providing an in-depth examination of the present state, challenges, and potential future advancements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/s23218840

Cites

131 of 131 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 The basic components and operation of an Industrial Control System.
Figure 1 The basic components and operation of an Industrial Control System.CC BY · PubMed Central
Figure 2 SCADA components.
Figure 2 SCADA components.CC BY · PubMed Central
Figure 3 Monolithic SCADA system.
Figure 3 Monolithic SCADA system.CC BY · PubMed Central
Figure 4 Distributed SCADA system.
Figure 4 Distributed SCADA system.CC BY · PubMed Central
Figure 5 Internet of Things (IoT) SCADA system.
Figure 5 Internet of Things (IoT) SCADA system.CC BY · PubMed Central
Figure 6 Networked SCADA architecture.
Figure 6 Networked SCADA architecture.CC BY · PubMed Central
Figure 7 A distributed control system.
Figure 7 A distributed control system.CC BY · PubMed Central
Figure 8 Components of a PLC system.
Figure 8 Components of a PLC system.CC BY · PubMed Central
Figure 9 Vulnerabilities of industrial protocols under an application scenario.
Figure 9 Vulnerabilities of industrial protocols under an application scenario.CC BY · PubMed Central
Figure 10 General Modbus framework.
Figure 10 General Modbus framework.CC BY · PubMed Central
Figure 11 MQTT protocol design.
Figure 11 MQTT protocol design.CC BY · PubMed Central
Figure 12 OPC protocol design.
Figure 12 OPC protocol design.CC BY · PubMed Central
Figure 13 Countermeasure for defending ICSs.
Figure 13 Countermeasure for defending ICSs.CC BY · PubMed Central
Figure 14 Network segmentation or zoning.
Figure 14 Network segmentation or zoning.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 11

  1. Björkman, G., Sommestad, T., Ekstedt, M., Hadeli, H., Liu, K., and Chenine, M. (2023, May 29). SCADA System Architectures. Available online: https://api.semanticscholar.org/CorpusID:109456860.
  2. Hemsley, K.E., and Fisher, D.R.E. (2023, May 28). History of Industrial Control System Cyber Incidents (Technical Report)|OSTI.GOV, Available online: https://www.osti.gov/servlets/purl/1505628.
  3. (2023, May 28). 2022 ICS/OT Cybersecurity Year in Review Report. Available online: https://hub.dragos.com/ics-cybersecurity-year-in-review-2022.
  4. (2023, June 12). Threat Models and Risk Assessments: Security IP. Synopsys. Available online: https://www.synopsys.com/designware-ip/technical-bulletin/using-threat-models-2017q4.html.
  5. Seo, M.J., Kim, T.O., and Lee, H.H. (2009, January 18–21). Implementation of web services based on IEC 61400-25 for wind power plants. Proceedings of the 2009 ICCAS-SICE, Fukuoka, Japan.
  6. Flaus, J.-M. (2019). Cybersecurity of Industrial Systems, Wiley. · DOI
  7. (2023, June 06). The Risk of Industrial Control System Programmable Logic Controller. Available online: https://ieeexplore.ieee.org/document/9359077.
  8. Yamanishi, K., and Takeuchi, J. (2023, July 14). Discovering Outlier Filtering Rules from Unlabeled Data: Combining a Supervised Learner with an Unsupervised Learner. Available online: https://api.semanticscholar.org/CorpusID:10897169.
  9. Sanchez-Pi, N., Martí, L., Molina, J.M., and Garcia, A.C.B. (2014). Communications in Computer and Information Science, Springer.
  10. (2023, July 13). Reliability, August 2016 a Density-Based Clustering Method for…. Available online: https://rs.ieee.org/images/files/techact/Reliability/2016-08/2016-08-a03.pdf.
  11. Lin, J., Dang, L., Rahouti, M., and Xiong, K. (2021). ML Attack Models: Adversarial Attacks and Data Poisoning Attacks. arXiv.

Cited by

See all 114

Metadata

Authors
Nankya, M., Chataut, R., & Akl, R.
Affiliations
  • Fitchburg State University (US)
  • Quinnipiac University (US)
  • University of North Texas (US)
Corresponding author
Nankya, Mary
Venue
Sensors
Publisher
MDPI AG
Published
2023-10-30
Volume
23
Issue
21
Pages
8840
ISSN
1424-8220 (ISSN-L)
OpenAlex
W4388018155
Cited by
114
References
129
Citations by year
2026: 45 · 2025: 38 · 2024: 31
FWCI
2.60
Type
journal article
Language
en
Open access
Locations
  • Sensors (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • University of North Texas Digital Library (University of North Texas) (submittedVersion, public-domain)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
  • Physical Sciences › Computer Science › Computer Networks and Communications › Network Security and Intrusion Detection
  • Physical Sciences › Engineering › Control and Systems Engineering › Industrial Automation and Control Systems
Keywords
industrial control systems, ICS security, SCADA, distributed control systems, programmable logic controller, cyber threats, vulnerability (computer security), network partitioning, access control, patch management, security monitoring, machine learning for cybersecurity, anomaly detection, threat intelligence, predictive maintenance

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.