Assessing Endothelial Vasodilator Function with the Endo-PAT 2000
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
The endothelium is a delicate monolayer of cells that lines all blood vessels, and which comprises the systemic and lymphatic capillaries. By virtue of the panoply of paracrine factors that it secretes, the endothelium regulates the contractile and proliferative state of the underlying vascular smooth muscle, as well as the interaction of the vessel wall with circulating blood elements. Because of its central role in mediating vessel tone and growth, its position as gateway to circulating immune cells, and its local regulation of hemostasis and coagulation, the the properly functioning endothelium is the key to cardiovascular health. Conversely, the earliest disorder in most vascular diseases is endothelial dysfunction. In the arterial circulation, the healthy endothelium generally exerts a vasodilator influence on the vascular smooth muscle. There are a number of methods to assess endothelial vasodilator function. The Endo-PAT 2000 is a new device that is used to assess endothelial vasodilator function in a rapid and non-invasive fashion. Unlike the commonly used technique of duplex ultra-sonography to assess flow-mediated vasodilation, it is totally non-operator-dependent, and the equipment is an order of magnitude less expensive. The device records endothelium-mediated changes in the digital pulse waveform known as the PAT (peripheral Arterial Tone) signal, measured with a pair of novel modified plethysmographic probes situated on the finger index of each hand. Endothelium-mediated changes in the PAT signal are elicited by creating a downstream hyperemic response. Hyperemia is induced by occluding blood flow through the brachial artery for 5 minutes using an inflatable cuff on one hand. The response to reactive hyperemia is calculated automatically by the system. A PAT ratio is created using the post and pre occlusion values. These values are normalized to measurements from the contra-lateral arm, which serves as control for non-endothelial dependent systemic effects. Most notably, this normalization controls for fluctuations in sympathetic nerve outflow that may induce changes in peripheral arterial tone that are superimposed on the hyperemic response. In this video we demonstrate how to use the Endo-PAT 2000 to perform a clinically relevant assessment of endothelial vasodilator function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Non-invasive detection of endothelial dysfunction in children and adults at risk of atherosclerosis
Celermajer, D. S., Sorensen, K. E., Gooch, V. M., Spiegelhalter, D. J., Miller, O. I., Sullivan, I. D., Lloyd, J. K., & Deanfield, J. E. (1992) · The Lancet · doi:10.1016/0140-6736(92)93147-f · Cited by 4,742
Endothelial Function and Dysfunction: Testing and Clinical Relevance
Deanfield, J. E., Halcox, J. P., & Rabelink, T. J. (2007) · Circulation · doi:10.1161/circulationaha.106.652859 · Cited by 2,710
Inflammation in Atherosclerosis
Libby, P., Ridker, P. M., & Hansson, G. K. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.09.009 · Cited by 2,228
Heitzer, T., Schlinzig, T., Krohn, K., Meinertz, T., & Münzel, T. (2001) · Circulation · doi:10.1161/hc4601.099485 · Cited by 1,961
Prognostic Value of Coronary Vascular Endothelial Dysfunction
Halcox, J. P. J., Schenke, W. H., Zalos, G., Mincemoyer, R., Prasad, A., Waclawiw, M. A., Nour, K. R. A., & Quyyumi, A. A. (2002) · Circulation · doi:10.1161/01.cir.0000025404.78001.d8 · Cited by 1,385
Böger, R. H., Bode-Böger, S. M., Szuba, A., Tsao, P. S., Chan, J. R., Tangphao, O., Blaschke, T. F., & Cooke, J. P. (1998) · Circulation · doi:10.1161/01.cir.98.18.1842 · Cited by 1,181
Self-citationBeyond Established and Novel Risk Factors: Lifestyle Risk Factors for Cardiovascular Disease
Mozaffarian, D., Wilson, P. W. F., & Kannel, W. B. (2008) · Circulation · doi:10.1161/circulationaha.107.738732 · Cited by 456
Nitric oxide and pathogenic mechanisms involved in the development of vascular diseases
Napoli, C., & Ignarro, L. J. (2009) · Archives of Pharmacal Research · doi:10.1007/s12272-009-1801-1 · Cited by 281
Cited by
Sayed, N., Liu, C., Ameen, M., Himmati, F., Zhang, J. Z., Khanamiri, S., Moonen, J.-R., Wnorowski, A., Cheng, L., Rhee, J.-W., et al. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aax9276 · Cited by 111
Rajala, S., Lindholm, H., & Taipalus, T. (2018) · Physiological Measurement · doi:10.1088/1361-6579/aac7ac · Cited by 70
“A device for assessing endothelial function is also commercially available (Axtell et al 2010).”
Background
Metadata
- Authors
- Axtell, A. L., Gomari, F. A., & Cooke, J. P.
- Venue
- Journal of Visualized Experiments
- Publisher
- MyJove Corporation
- Published
- 2010-10-15
- Issue
- 44
- ISSN
- 1940-087X (ISSN-L)
- DOI
- 10.3791/2167
- OpenAlex
- W1984468760
- Cited by
- 163
- References
- 8
- FWCI
- 0.61
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessing Endothelial Vasodilator Function with the Endo-PAT 2000. https://app.cochat.ai/papers/10.3791/2167
- The paper
- Axtell, A. L., Gomari, F. A., & Cooke, J. P. (2010). Assessing Endothelial Vasodilator Function with the Endo-PAT 2000. Journal of Visualized Experiments. https://doi.org/10.3791/2167
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.