Emerging Nucleic Acid–Based Tests for Point-of-Care Detection of Malaria
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Malaria remains a serious disease in the developing world. There is a growing consensus that new diagnostics are needed in low-resource settings. The ideal malaria diagnostic should be able to speciate; measure parasitemia; low-cost, quick, and simple to use; and capable of detecting low-level infections. A promising development are nucleic acid tests (NATs) for the diagnosis of malaria, which are well suited for point-of-care use because of their ability to detect low-level infections and speciate, and because they have high sensitivity and specificity. The greatest barrier to NAT use in the past has been its relatively high cost, and the amount of infrastructure required in the form of equipment, stable power, and reagent storage. This review describes recent developments to decrease the cost and run time, and increase the ease of use of NAT while maintaining their high sensitivity and specificity and low limit of detection at the point-of-care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Loop-mediated isothermal amplification of DNA
Notomi, T. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e63 · Cited by 8,805 · cited 1×
“67 It also generates a magnesium pyro-phosphate precipitate during amplification, which can be used for detection by measuring the turbidity of the solution.”
CONQUERING THE INTOLERABLE BURDEN OF MALARIA: WHAT’S NEW, WHAT’S NEEDED: A SUMMARY
BREMAN, J. G., ALILIO, M. S., & MILLS, A. (2004) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2004.71.2_suppl.0700001 · Cited by 677 · cited 1×
“3,62,63 EMERGING NUCLEIC ACID TESTS The NATs have the potential to offer many advantages at the POC, such as low limits of detection, the ability to speci-ate, and to quantify the level of infection.”
Okell, L. C., Ghani, A. C., Lyons, E., & Drakeley, C. J. (2009) · The Journal of Infectious Diseases · doi:10.1086/644781 · Cited by 532 · cited 4×
“other research has found that microscopy may miss as many as 50% of the cases detected by PCR.(23,24) Antigen detection and rapid diagnostic tests.”
InfluentialPoon, L. L., Wong, B. W., Ma, E. H., Chan, K. H., Chow, L. M., Abeyewickreme, W., Tangpukdee, N., Yuen, K. Y., Guan, Y., Looareesuwan, S., et al. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.057901 · Cited by 476
Perandin, F., Manca, N., Calderaro, A., Piccolo, G., Galati, L., Ricci, L., Medici, M. C., Arcangeletti, M. C., Snounou, G., Dettori, G., et al. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.3.1214-1219.2004 · Cited by 354
Persistence of Plasmodium falciparum HRP-2 in successfully treated acute falciparum malaria
Mayxay, M., Pukrittayakamee, S., Chotivanich, K., Looareesuwan, S., & White, N. J. (2001) · Transactions of the Royal Society of Tropical Medicine and Hygiene · doi:10.1016/s0035-9203(01)90156-7 · Cited by 175
Evaluation of rapid diagnostic tests: malaria
Bell, D., & Peeling, R. W. (2006) · Nature Reviews Microbiology · doi:10.1038/nrmicro1524 · Cited by 170
Polley, S. D., Mori, Y., Watson, J., Perkins, M. D., González, I. J., Notomi, T., Chiodini, P. L., & Sutherland, C. J. (2010) · Journal of Clinical Microbiology · doi:10.1128/jcm.00355-10 · Cited by 167
Rapid diagnostic testing for malaria
Murray, C. K., Bell, D., Gasser, R. A., & Wongsrichanalai, C. (2003) · Tropical Medicine & International Health · doi:10.1046/j.1365-3156.2003.01115.x · Cited by 157
Loop-Mediated Isothermal PCR (LAMP) for the Diagnosis of Falciparum Malaria
Paris, D. H., Imwong, M., Faiz, A. M., Hasan, M., Yunus, E. B., Silamut, K., Lee, S. J., Day, N. P. J., & Dondorp, A. M. (2007) · The American Journal of Tropical Medicine and Hygiene · doi:10.4269/ajtmh.2007.77.972 · Cited by 132 · cited 7×
“The LAMP can also be used with samples that have undergone minimal pre-processing, and results can be monitored with turbidity measurements, making it especially suited for use as a malaria POC diagnostic because it has comparable material costs to the commercial price to users of RDTs. 72 However, extra amplification…”
Influential
Cited by
Rapid, Low-Cost Detection of Zika Virus Using Programmable Biomolecular Components
Pardee, K., Green, A. A., Takahashi, M. K., Braff, D., Lambert, G., Lee, J. W., Ferrante, T., Ma, D., Donghia, N., Fan, M., et al. (2016) · Cell · doi:10.1016/j.cell.2016.04.059 · Cited by 1,439
Two distinct RNase activities of CRISPR-C2c2 enable guide-RNA processing and RNA detection
East-Seletsky, A., O’Connell, M. R., Knight, S. C., Burstein, D., Cate, J. H. D., Tjian, R., & Doudna, J. A. (2016) · Nature · doi:10.1038/nature19802 · Cited by 1,236
Paper-Based Synthetic Gene Networks
Pardee, K., Green, A. A., Ferrante, T., Cameron, D. E., DaleyKeyser, A., Yin, P., & Collins, J. J. (2014) · Cell · doi:10.1016/j.cell.2014.10.004 · Cited by 700
The changing epidemiology of malaria elimination: New strategies for new challenges
Cotter, C., Sturrock, H. J., Hsiang, M. S., Liu, J., Phillips, A. A., Hwang, J., Gueye, C. S., Fullman, N., Gosling, R. D., & Feachem, R. G. (2013) · The Lancet · doi:10.1016/s0140-6736(13)60310-4 · Cited by 671
Nanoparticle-based lateral flow biosensors
Quesada-González, D., & Merkoçi, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.050 · Cited by 597
Targeting Asymptomatic Malaria Infections: Active Surveillance in Control and Elimination
Sturrock, H. J. W., Hsiang, M. S., Cohen, J. M., Smith, D. L., Greenhouse, B., Bousema, T., & Gosling, R. D. (2013) · PLoS Medicine · doi:10.1371/journal.pmed.1001467 · Cited by 341
Qu, H., Fan, C., Chen, M., Zhang, X., Yan, Q., Wang, Y., Zhang, S., Gong, Z., Shi, L., Li, X., et al. (2021) · Journal of Nanobiotechnology · doi:10.1186/s12951-021-01149-z · Cited by 306
“Paper Machine” for Molecular Diagnostics
Connelly, J. T., Rolland, J. P., & Whitesides, G. M. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00411 · Cited by 289
Banerjee, R., & Jaiswal, A. (2018) · The Analyst · doi:10.1039/c8an00307f · Cited by 265
Isothermal Amplification of Nucleic Acids: The Race for the Next “Gold Standard”
Oliveira, B. B., Veigas, B., & Baptista, P. V. (2021) · Frontiers in Sensors · doi:10.3389/fsens.2021.752600 · Cited by 235
“Nevertheless, there are limitations concerning NASBA implementation, such as the challenge to optimize three different enzymes that leads to higher costs, and the susceptibility to false positives that require additional probespecific detection methods, which are generally more expensive than non-specific dyes (Cordra…”
BackgroundAdvances in molecular diagnosis of malaria
(2017) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2016.11.006 · Cited by 41
Metadata
- Authors
- Cordray, M. S., & Richards-Kortum, R. R.
- Venue
- The American Society of Tropical Medicine and Hygiene
- Published
- 2012-08-01
- Volume
- 87
- Issue
- 2
- Pages
- 223-230
- ISSN
- 0002-9637 (ISSN-L)
- 1476-1645
- OpenAlex
- W2138054293
- Cited by
- 138
- References
- 13
- FWCI
- 8.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.