Electrical impedance spectroscopy (EIS) for biological analysis and food characterization: a review
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
Electrical impedance spectroscopy (EIS), in which a sinusoidal test voltage or current is applied to the sample under test to measure its impedance over a suitable frequency range, is a powerful technique to investigate the electrical properties of a large variety of materials. In practice, the measured impedance spectra, usually fitted with an equivalent electrical model, represent an electrical fingerprint of the sample providing an insight into its properties and behavior. EIS is used in a broad range of applications as a quick and easily automated technique to characterize solid, liquid, semiliquid, organic as well as inorganic materials. This paper presents an updated review of EIS main implementations and applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Food-Related Illness and Death in the United States
Mead, P. S., Slutsker, L., Dietz, V., McCaig, L. F., Bresee, J. S., Shapiro, C., Griffin, P. M., & Tauxe, R. V. (1999) · Emerging Infectious Diseases · doi:10.3201/eid0505.990502 · Cited by 7,235
Impedance Spectroscopy: Theory, Experiment, and Applications
(2005) · Wiley eBooks · doi:10.1002/0471716243 · Cited by 5,322
Bioelectrical impedance analysis?part I: review of principles and methods
KYLE, U. (2004) · Clinical Nutrition · doi:10.1016/j.clnu.2004.06.004 · Cited by 3,200 · cited 1×
“4a (Kyle et al., 2004; Mialich et al., 2014).”
Electrochemical Impedance Spectroscopy
Orazem, M. E., & Tribollet, B. (2008) · Wiley eBooks · doi:10.1002/9780470381588 · Cited by 1,676
Electrochemical Impedance Spectroscopy
(2016) · Encyclopedia of Membranes · doi:10.1007/978-3-662-44324-8_100089 · Cited by 1,580
Electrochemical Impedance Spectroscopy
Chang, B.-Y., & Park, S.-M. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.012809.102211 · Cited by 1,248
Fabregat-Santiago, F., Bisquert, J., Garcia-Belmonte, G., Boschloo, G., & Hagfeldt, A. (2005) · Solar Energy Materials and Solar Cells · doi:10.1016/j.solmat.2004.07.017 · Cited by 1,179
A Linear Kronig‐Kramers Transform Test for Immittance Data Validation
Boukamp, B. A. (1995) · Journal of The Electrochemical Society · doi:10.1149/1.2044210 · Cited by 880
Corrosion inhibition by Justicia gendarussa plant extract in hydrochloric acid solution
Satapathy, A. K., Gunasekaran, G., Sahoo, S.-S., Amit, K., & Rodrigues, P. V. (2009) · Corrosion Science · doi:10.1016/j.corsci.2009.08.016 · Cited by 823
Electrochemical impedance spectroscopy: an overview of bioanalytical applications
Randviir, E. P., & Banks, C. E. (2013) · Analytical Methods · doi:10.1039/c3ay26476a · Cited by 795
Amirudin, A., & Thieny, D. (1995) · Progress in Organic Coatings · doi:10.1016/0300-9440(95)00581-1 · Cited by 740
Khalil, S., Mohktar, M., & Ibrahim, F. (2014) · Sensors · doi:10.3390/s140610895 · Cited by 712 · cited 1×
“TBW is the major compound of FFM that helps the flow of electrical current due to the conductivity of electrolytes dissolved in body water (Khalil et al., 2014).”
BackgroundAC impedance technique in PEM fuel cell diagnosis—A review
YUAN, X., WANG, H., COLINSUN, J., & ZHANG, J. (2007) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2007.05.036 · Cited by 711
A Method for Improving the Robustness of linear Kramers-Kronig Validity Tests
Schönleber, M., Klotz, D., & Ivers-Tiffée, E. (2014) · Electrochimica Acta · doi:10.1016/j.electacta.2014.01.034 · Cited by 595
Huet, F. (1998) · Journal of Power Sources · doi:10.1016/s0378-7753(97)02665-7 · Cited by 593 · cited 2×
“can be estimated by looking at the cell electrical parameters (Huet, 1998; Rodrigues et al., 2000).”
BackgroundElectrochemical impedance spectroscopy as a tool for investigating underpaint corrosion
Bonora, P. L., Deflorian, F., & Fedrizzi, L. (1996) · Electrochimica Acta · doi:10.1016/0013-4686(95)00440-8 · Cited by 591
Single prediction equation for bioelectrical impedance analysis in adults aged 20–94 years
Kyle, U. G., Genton, L., Karsegard, L., Slosman, D. O., & Pichard, C. (2001) · Nutrition · doi:10.1016/s0899-9007(00)00553-0 · Cited by 575 · cited 1×
“For example, Kyle et al. (2011) proposed a single equation to predict FFM in subjects from 22 to 94 years old as function of resistance and reactance measured at 50 kHz, height, weight and gender.”
BackgroundAndre, D., Meiler, M., Steiner, K., Walz, H., Soczka-Guth, T., & Sauer, D. U. (2011) · Journal of Power Sources · doi:10.1016/j.jpowsour.2010.07.071 · Cited by 547
Correlation of whole-body impedance with total body water volume.
Hoffer, E. C., Meador, C. K., & Simpson, D. C. (1969) · Journal of Applied Physiology · doi:10.1152/jappl.1969.27.4.531 · Cited by 525
Jaffrin, M. Y., & Morel, H. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.06.009 · Cited by 490
A review of state-of-charge indication of batteries by means of a.c. impedance measurements
Rodrigues, S., Munichandraiah, N., & Shukla, A. K. (2000) · Journal of Power Sources · doi:10.1016/s0378-7753(99)00351-1 · Cited by 436
Christensen, B. J., Coverdale, T., Olson, R. A., Ford, S. J., Garboczi, E. J., Jennings, H. M., & Mason, T. O. (1994) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1994.tb04507.x · Cited by 413
Bioelectrical Impedance Methods for Noninvasive Health Monitoring: A Review
Bera, T. K. (2014) · Journal of Medical Engineering · doi:10.1155/2014/381251 · Cited by 407
A review of AC impedance modeling and validation in SOFC diagnosis
Huang, Q.-A., Hui, R., Wang, B., & Zhang, J. (2007) · Electrochimica Acta · doi:10.1016/j.electacta.2007.05.071 · Cited by 403
Urquidi-Macdonald, M., Real, S., & Macdonald, D. D. (1990) · Electrochimica Acta · doi:10.1016/0013-4686(90)80010-l · Cited by 320
New Trends in Impedimetric Biosensors for the Detection of Foodborne Pathogenic Bacteria
Wang, Y., Ye, Z., & Ying, Y. (2012) · Sensors · doi:10.3390/s120303449 · Cited by 268
Single- and multifrequency models for bioelectrical impedance analysis of body water compartments
Gudivaka, R., Schoeller, D. A., Kushner, R. F., & Bolt, M. J. G. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.3.1087 · Cited by 261
Design and Fabrication of a Microimpedance Biosensor for Bacterial Detection
Radke, S. M., Alocilja, E. C., Radke, S. M., & Alocilja, E. C. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.830300 · Cited by 247
Lizhi, H., Toyoda, K., & Ihara, I. (2008) · Journal of Food Engineering · doi:10.1016/j.jfoodeng.2007.12.035 · Cited by 244
Impedance spectroscopy study of hardened Portland cement paste
Cabeza, M., Merino, P., Miranda, A., Nóvoa, X. R., & Sanchez, I. (2002) · Cement and Concrete Research · doi:10.1016/s0008-8846(02)00720-2 · Cited by 227
Shafer, K. J., Siders, W. A., Johnson, L. K., & Lukaski, H. C. (2009) · Nutrition · doi:10.1016/j.nut.2008.07.004 · Cited by 223
Impedance microbiology—a rapid change for microbiologists
Silley, P., & Forsythe, S. (1996) · Journal of Applied Bacteriology · doi:10.1111/j.1365-2672.1996.tb03215.x · Cited by 203
Analysis of Body Composition: A Critical Review of the Use of Bioelectrical Impedance Analysis
Mialich, M. S., Sicchieri, J. M. F., & Jordão, A. A. (2014) · doi:10.12691/ijcn-2-1-1 · Cited by 202
UTTER, A. C., Nieman, D. C., Ward, A., & Butterworth, D. E. (1999) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/69.4.603 · Cited by 179
Gomez-Sjoberg, R., Morisette, D. T., & Bashir, R. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.845444 · Cited by 174
Dong, J., Zhao, H., Xu, M., Ma, Q., & Ai, S. (2013) · Food Chemistry · doi:10.1016/j.foodchem.2013.04.098 · Cited by 165
Hannan, W. J., Cowen, S. J., Fearon, K. C. H., Plester, C. E., Falconer, J. S., & Richardson, R. A. (1994) · Clinical Science · doi:10.1042/cs0860479 · Cited by 122
Haverkort, E. B., Reijven, P. L. M., Binnekade, J. M., de van der Schueren, M. A. E., Earthman, C. P., Gouma, D. J., & de Haan, R. J. (2014) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2014.203 · Cited by 109
Ran, L., Junfeng, W., Haiying, W., & Gechen, L. (2010) · 2010 5th IEEE Conference on Industrial Electronics and Applications · doi:10.1109/iciea.2010.5516984 · Cited by 105
Review—Nonlinear Electrochemical Impedance Spectroscopy
Fasmin, F., & Srinivasan, R. (2017) · Journal of The Electrochemical Society · doi:10.1149/2.0391707jes · Cited by 96
Yang, Y., Wang, J., Yu, G., Niu, F., & He, P. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/12/004 · Cited by 93
Stewart, G. N. (1899) · Journal of Experimental Medicine · doi:10.1084/jem.4.2.235 · Cited by 83
Lohmann, N., Weßkamp, P., Haußmann, P., Melbert, J. G., & Musch, T. (2014) · Journal of Power Sources · doi:10.1016/j.jpowsour.2014.09.132 · Cited by 82
Deurenberg, P., & Deurenberg‐Yap, M. (2002) · Asia Pacific Journal of Clinical Nutrition · doi:10.1046/j.1440-6047.2002.00258.x · Cited by 79
Xie, X., Kolthoff, N., Bärenholt, O., & Sp, N. (1999) · International Journal of Obesity · doi:10.1038/sj.ijo.0801034 · Cited by 69
Impedimetric method for measuring ultra-low E. coli concentrations in human urine
Settu, K., Chen, C.-J., Liu, J.-T., Chen, C., & Tsai, J. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.11.027 · Cited by 67
Blood Glucose Measurement Using Bioimpedance Technique
Kamat, D. K., Bagul, D., & Patil, P. M. (2014) · Advances in Electronics · doi:10.1155/2014/406257 · Cited by 56
Chuang, C., Du, Y., Wu, T.-F., Chen, C.-H., Lee, D.-H., Chen, S.-M., Huang, T.-C., Wu, H.-P., & Shaikh, M. O. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.103 · Cited by 54
SoC Li-ion battery monitoring with impedance spectroscopy
Cuadras, A., & Kanoun, O. (2009) · 2009 6th International Multi-Conference on Systems, Signals and Devices · doi:10.1109/ssd.2009.4956761 · Cited by 50
Validity of Hand‐to‐Foot Measurement of Bioimpedance: Standing Compared with Lying Position
Rush, E. C., Crowley, J., Freitas, I. F., & Luke, A. (2006) · Obesity · doi:10.1038/oby.2006.32 · Cited by 49
Body composition at the bedside
Ghosh, S., Meister, D., Cowen, S., Hannan, J. W., & Ferguson, A. (1997) · European Journal of Gastroenterology & Hepatology · doi:10.1097/00042737-199708000-00009 · Cited by 43
Ibrahim, F., Taib, M. N., Abas, W. A. B. W., Guan, C. C., & Sulaiman, S. (2005) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2004.840237 · Cited by 36
Sensor and Methodology for Dielectric Analysis of Vegetal Oils Submitted to Thermal Stress
Stevan, S. L., Paiter, L., Galvão, J. R., Roque, D. V., & Chaves, E. S. (2015) · Sensors · doi:10.3390/s151026457 · Cited by 34
16 Methods for Detecting Microbial Pathogens in Food and Water
Kaspar, C. W., & Tartera, C. (1990) · Methods in microbiology · doi:10.1016/s0580-9517(08)70253-8 · Cited by 32
Mortari, A., Adami, A., & Lorenzelli, L. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.09.075 · Cited by 29
New equivalent-electrical circuit model and a practical measurement method for human body impedance
Chinen, K., Kinjo, I., Zamami, A., Irei, K., & Nagayama, K. (2015) · Bio-Medical Materials and Engineering · doi:10.3233/bme-151369 · Cited by 26
Barton, R. T., & Mitchell, P. J. (1989) · Journal of Power Sources · doi:10.1016/0378-7753(89)80043-6 · Cited by 22
A Study of Bioelectrical Impedance Analysis Methods for Practical Visceral Fat Estimation
Yoneda, M., Tasaki, H., Tsuchiya, N., Nakajima, H., Hamaguchi, T., Oku, S., & Shiga, T. (2007) · IEEE International Conference on Granular Computing (GrC) · doi:10.1109/grc.2007.109 · Cited by 21
Rough Set Approximations Based on Random Sets
Wu, W.-Z. (2007) · IEEE International Conference on Granular Computing (GrC) · doi:10.1109/grc.2007.22 · Cited by 20
An impedimetric method for rapid screening of cosmetic preservatives
Zhou, X., & King, V. M. (1995) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/bf01569807 · Cited by 19
Kagawa, M., Wishart, C., & Hills, A. P. (2014) · Nutrients · doi:10.3390/nu6051886 · Cited by 15
Cited by
Structure-function and application of plant lectins in disease biology and immunity
Mishra, A., Behura, A., Mawatwal, S., Kumar, A., Naik, L., Mohanty, S. S., Manna, D., Dokania, P., Mishra, A., Patra, S. K., et al. (2019) · Food and Chemical Toxicology · doi:10.1016/j.fct.2019.110827 · Cited by 227
“EIS technique provides sensitive, specific, robust and portable biosensing system with combination of carbohydrate and can also be used as an effective tool to characterize and detect the surface modification and bio-recognition process (Grossi and Riccò, 2016).”
Metadata
- Authors
- Grossi, M., & Riccò, B.
- Venue
- Journal of Sensors and Sensor Systems
- Publisher
- Copernicus GmbH
- Published
- 2017-08-28
- Volume
- 6
- Issue
- 2
- Pages
- 303-325
- ISSN
- 2194-8771 (ISSN-L)
- 2194-878X
- OpenAlex
- W2745683126
- Cited by
- 394
- References
- 61
- FWCI
- 10.96
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.