Hospital Ventilation and Risk for Tuberculous Infection in Canadian Health Care Workers
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
BACKGROUND: The risk for and determinants of transmission of tuberculosis in hospitals caring for moderate numbers of patients with tuberculosis remain uncertain. OBJECTIVE: To study the association of tuberculin conversion among health care workers with ventilation of patient care areas. DESIGN: Cross-sectional observational survey. SETTING: 17 acute-care community or university hospitals. PARTICIPANTS: All personnel who worked at least 2 days per week in the respiratory and physiotherapy departments or in selected nursing units. MEASUREMENTS: Participating workers underwent tuberculin skin testing and completed self-administered questionnaires. Previous tuberculin tests and bacille Calmette-Guérin vaccinations were verified. Records of patients with tuberculosis who were hospitalized in the 3 years preceding the study were reviewed. Air exchanges per hour in patient care areas were measured by using a tracer gas technique. Multivariate proportional hazards regression was used to estimate the effect of occupational factors on documented tuberculin conversion, after adjustment for nonoccupational factors, among participants with at least one previous negative result on tuberculin skin testing. RESULTS: Tuberculin conversion was associated with ventilation of general or nonisolation patient rooms of less than 2 air exchanges per hour (adjusted hazard ratio, 3.4 [95% CI, 2.1 to 5.8]); with work in moderate- to high-risk hospitals (adjusted hazard ratio, 2.2 [CI, 1.3 to 3.5]); and with work in the nursing (adjusted hazard ratio, 4.3 [CI, 2.7 to 6.9]), respiratory therapy (adjusted hazard ratio, 6.1 [CI, 3.1 to 12.0]), and physiotherapy (adjusted hazard ratio, 3.3 [CI, 1.5 to 7.2]) departments or housekeeping (adjusted hazard ratio, 4.2 [CI, 2.3 to 7.6]). Conversion was not associated with inadequate ventilation of respiratory isolation rooms (adjusted hazard ratio, 1.0 [CI, 0.8 to 1.3]). CONCLUSION: Tuberculin conversion among health care workers was strongly associated with inadequate ventilation in general patient rooms and with type and duration of work, but not with ventilation of respiratory isolation rooms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Regression Models and Life-Tables
Cox, D. R. (1972) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1972.tb00899.x · Cited by 39,793
Regression Models and Life-Tables
Cox, D. R. (1992) · Springer Series in Statistics · doi:10.1007/978-1-4612-4380-9_37 · Cited by 26,297
Basic and Clinical Biostatistics,
(2002) · Survey of Ophthalmology · doi:10.1016/s0039-6257(02)00360-0 · Cited by 1,809 · cited 1×
“Bivariate associations were tested by using unpaired t-tests for continuous variables and chi-square tests for categorical variables (29).”
MethodBass, J. B., Farer, L. S., Hopewell, P. C., O'Brien, R., Jacobs, R. F., Ruben, F., Snider, D. E., & Thornton, G. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173779 · Cited by 1,193 · cited 3×
“When the analysis was repeated with conversion defined by using American Thoracic Society standards (an increase in tuberculin reactions $ 15 mm in workers .”
BackgroundDaley, C. L., Small, P. M., Schecter, G. F., Schoolnik, G. K., McAdam, R. A., Jacobs, W. R., & Hopewell, P. C. (1992) · New England Journal of Medicine · doi:10.1056/nejm199201233260404 · Cited by 986 · cited 4×
“001 Nurse 190 (20) 788 (80) Respiratory therapist 27 (20) 107 (20) Physiotherapist 9 (9) 88 (91) Housekeeping 7 (54) 6 (46) Known tuberculosis exposures, n 4.”
BackgroundInfluentialEdlin, B. R., Tokars, J. I., Grieco, M. H., Crawford, J. T., Williams, J., Sordillo, E. M., Ong, K. R., Kilburn, J. O., Dooley, S. W., Castro, K. G., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199206043262302 · Cited by 861 · cited 1×
“04 Works in high-risk hospital, n (%) Yes 229 (19) 987 (81) No (works in low-risk hospital) 9 (12) 64 (88) Department or position, n (%) Nonclinical 5 (7) 62 (93) ,0.”
De, N., Rs, K., Rl, L., Chrismon, J. H., Merritt, R., Da, A., & Giovino, G. A. (1994) · PubMed · Cited by 797
Cox regression analysis of multivariate failure time data: The marginal approach
Lin, D. Y. (1994) · Statistics in Medicine · doi:10.1002/sim.4780132105 · Cited by 588 · cited 2×
“Proportional hazards regression, adjusted for potentially confounding factors, was performed to estimate the effect of ventilation; adjustment for potential clustering (31) was then done because we used hospital unit–based measures of exposure.”
MethodPearson, M. L., Jereb, J. A., Frieden, T. R., Crawford, J. T., Davis, B. J., Dooley, S. W., & Jarvis, W. R. (1992) · Annals of Internal Medicine · doi:10.7326/0003-4819-117-3-191 · Cited by 546
Measurement of Delayed Skin-Test Responses
Sokal, J. E. (1975) · New England Journal of Medicine · doi:10.1056/nejm197509042931013 · Cited by 500
Cited by
A Review of the Research Literature on Evidence-Based Healthcare Design
Ulrich, R. S., Zimring, C., Zhu, X., DuBose, J., Seo, H.-B., Choi, Y.-S., Quan, X., & Joseph, A. (2008) · HERD: Health Environments Research & Design Journal · doi:10.1177/193758670800100306 · Cited by 1,421
(2005) · PsycEXTRA Dataset · doi:10.1037/e545842006-001 · Cited by 1,274
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
Mendell, M. J., & Heath, G. A. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2004.00320.x · Cited by 1,034
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Inhalable Microorganisms in Beijing’s PM2.5 and PM10 Pollutants during a Severe Smog Event
Cao, C., Jiang, W., Wang, B., Fang, J., Lang, J., Tian, G., Jiang, J., & Zhu, T. F. (2014) · Environmental Science & Technology · doi:10.1021/es4048472 · Cited by 669
Tang, J. W., Li, Y., Eames, I., Chan, P. K. S., & Ridgway, G. L. (2006) · Journal of Hospital Infection · doi:10.1016/j.jhin.2006.05.022 · Cited by 667
Tuberculosis: A Radiologic Review
Burrill, J., Williams, C. J., Bain, G., Conder, G., Hine, A. L., & Misra, R. R. (2007) · RadioGraphics · doi:10.1148/rg.275065176 · Cited by 604
Natural Ventilation for the Prevention of Airborne Contagion
Escombe, A. R., Oeser, C. C., Gilman, R. H., Navincopa, M., Ticona, E., Pan, W., Martínez, C., Chacaltana, J., Rodríguez, R., Moore, D. A. J., et al. (2007) · PLoS Medicine · doi:10.1371/journal.pmed.0040068 · Cited by 420
Aerobiology and Its Role in the Transmission of Infectious Diseases
Fernstrom, A., & Goldblatt, M. (2013) · Journal of Pathogens · doi:10.1155/2013/493960 · Cited by 363
Qian, H., Li, Y., Nielsen, P. V., Hyldgaard, C. E., Wong, T. W., & Chwang, A. T. Y. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00407.x · Cited by 294
Azuma, K., Yanagi, U., Kagi, N., Kim, H., Ogata, M., & Hayashi, M. (2020) · Environmental Health and Preventive Medicine · doi:10.1186/s12199-020-00904-2 · Cited by 263
Rashid, M., & Zimring, C. (2008) · Environment and Behavior · doi:10.1177/0013916507311550 · Cited by 252
Ventilation control for airborne transmission of human exhaled bio-aerosols in buildings
Qian, H., & Zheng, X. (2018) · Journal of Thoracic Disease · doi:10.21037/jtd.2018.01.24 · Cited by 249
“studied the association between tuberculin conversion among HCWs and the ventilation rate in patient care areas (34).”
BackgroundMendell, M. J., Fisk, W. J., Kreiss, K., Levin, H., Alexander, D., Cain, W. S., Girman, J. R., Hines, C. J., Jensen, P. A., Milton, D. K., et al. (2002) · American Journal of Public Health · doi:10.2105/ajph.92.9.1430 · Cited by 229
The Economic Impact of Methicillin-Resistant Staphylococcus aureus in Canadian Hospitals
Kim, T., Oh, P. I., & Simor, A. E. (2001) · Infection Control & Hospital Epidemiology · doi:10.1086/501871 · Cited by 213
Delay in Diagnosis among Hospitalized Patients with Active Tuberculosis—Predictors and Outcomes
Greenaway, C., Menzies, D., Fanning, A., Grewal, R., Yuan, L., Mark FitzGerald, J., & The Canadian Collaborative Group in Nosocomial Transmission of Tuberculosis (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.165.7.2107040 · Cited by 192
Self-citationThe transmission of Mycobacterium tuberculosis in high burden settings
Yates, T. A., Khan, P. Y., Knight, G. M., Taylor, J. G., McHugh, T. D., Lipman, M., White, R. G., Cohen, T., Cobelens, F. G., Wood, R., et al. (2016) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(15)00499-5 · Cited by 192
Dispersion of exhalation pollutants in a two-bed hospital ward with a downward ventilation system
Qian, H., Li, Y., Nielsen, P. V., & Hyldgaard, C. E. (2008) · Building and Environment · doi:10.1016/j.buildenv.2006.03.025 · Cited by 169
GAMAGE, B., MOORE, D., COPES, R., YASSI, A., & BRYCE, E. (2005) · American Journal of Infection Control · doi:10.1016/j.ajic.2004.12.002 · Cited by 160
“Similarly, Canadian researchers have shown that inadequate ventilation systems in general patient rooms can lead to increased risks to tuberculosis infection for health care workers because of patients with unrecognized infections.(28) These observations emphasize that early identification of high-risk patients combin…”
BackgroundDu, C., Wang, S., Yu, M., Chiu, T., Wang, J., Chuang, P., Jou, R., Chan, P., & Fang, C. (2020) · Indoor Air · doi:10.1111/ina.12639 · Cited by 84
Metadata
- Authors
- Menzies, D., Fanning, A., Yuan, L., FitzGerald, J. M., & and the Canadian Collaborative Group in Nosocomial Transmission of TB*
- Venue
- Annals of Internal Medicine
- Publisher
- American College of Physicians
- Published
- 2000-11-21
- Volume
- 133
- Issue
- 10
- Pages
- 779-789
- ISSN
- 0003-4819 (ISSN-L)
- 1539-3704
- OpenAlex
- W2124069146
- Cited by
- 212
- References
- 31
- FWCI
- 2.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.